24 RCNY Chapter 40 Certification of Radon and Other Vapors Levels in Certain Basement and Cellar Apartments
§ 40-01. Scope and applicability
This chapter applies to the certification for permissible maximum radon and other vapor levels in basement or cellar apartment units as required by § 28-507.4.5.2 of the Administrative Code and sections U202.9 and U202.10 of Appendix U of the New York City Building Code (Chapter 8 of Title 28 of the Administrative Code).
§ 40-02. Definitions
Terms used in this chapter have the same meanings as the terms defined in § 28-507.1 of the Administrative Code and in Appendix BC U102 of Appendix U of the New York City Building Code. In addition, the following definitions shall apply:
“Certification” means the certification described in sections U202.9 or U202.10 of Appendix U of the New York City Building Code.
“Certified Industrial Hygienist” means an individual certified as such by the Board for Global EHS Credentialing.
“Department” means the Department of Health and Mental Hygiene.
“Qualified Environmental Professional” has the same meaning as such term is defined in 6 NYCRR 375-1.2(ak).
“Qualified radon tester” means an individual or firm certified as such by the American Association of Radon Scientists and Technologists, the National Radon Safety Board, the State of New Jersey, or the Commonwealth of Pennsylvania.
§ 40-03. Methods of indoor air testing
All indoor air samples must be tested and reported by a laboratory certified by the New York State Environmental Laboratory Approval Program to analyze air samples for radon and volatile organic compounds using the appropriate sampling method:
(a) Radon. Testing of indoor air for radon must be conducted by a qualified radon tester using a testing device approved by the National Radon Proficiency Program, the National Radon Safety Board, or an equivalent program that verifies device compliance with the latest publication of ANSI/AARST (Performance Specification for Instrumentation Systems Designed to Measure Radon Gas in Air).
(b) Volatile Organic Compounds. Testing of indoor air for the volatile organic compounds listed in 24 RCNY § 40-06 must be conducted by a Certified Industrial Hygienist or Qualified Environmental Professional using the process described in United States Environmental Protection Agency, Method TO-15A: Determination of Volatile Organic Compounds (VOCs) in Air Collected in Specially Prepared Canisters and Analyzed by Gas Chromatography–Mass Spectrometry (GC-MS), Sept. 2019.
§ 40-04. Radon level certification
The radon level in any eligible basement or cellar apartment or ancillary dwelling unit must be less than two picocuries per liter of air based upon laboratory results as certified by a qualified radon tester.
§ 40-05. Volatile organic compound vapor level certification
The indoor air levels for the following volatile organic compounds must be less than the limit for each such compound set in the table below, as certified by a Qualified Environmental Professional:
Compound Limit (µg/m 3 ) Tetrachloroethene 30 Trichloroethene 2 Methylene chloride 60 Vinyl chloride 0.2 Carbon tetrachloride 1 1,1-dichloroethene 1 1,1,1-trichloroethane 10 Cis-1,2-dichloroethene 1 Benzene 10 Toluene 50 Ethylbenzene 10 o-Xylene 10 m,p-Xylene 20 Naphthalene 10 Cyclohexane 10 2,2,4-Trimethylpentane 10 1,2,4-Trimethylbenzene 10 1,3,5-Trimethylbenzene 10 Heptane 20 Hexane 20
§ 40-06. Submission of certification
The certifications of the qualified radon tester and the qualified environmental professional who conducted or reviewed the indoor air testing pursuant to this chapter must be submitted on the forms provided by the Department to, and as required by, the Department of Buildings.
(Added City Record 10/9/2025, eff. 10/9/2025)