28 RCNY Appendix A to 28 RCNY Chapter 61 Industrial Air Quality Checklist

To determine the potential for exceedance of the New York State Department of Environmental Conservation (DEC) Division of Air Resources Guidelines for Evaluation and Control of Ambient Air Contaminants (DAR-1) guidelines at a developable site resulting from industrial emissions, emissions from industrial sources within 400 feet of the development site shall be determined from emission limits in permits issued by the New York City Department of Environmental Protection (DEP) or for unpermitted sources, from the estimated emission limits provided by the lead agency and for Title V or state facility-permitted sources within 1,000 feet of the development site, from the emissions limits in the DEC Title V or state facility permits. For purposes of this Appendix, industrial sources means air emission sources (direct and fugitive emissions) that have or should have an existing or expired DEP Clean Air Tracking System industrial permit, concrete batching plants, or material handling facilities. The emissions from any existing industrial or state permitted source or emission assumptions for any unpermitted industrial source must first be converted into grams/second. This converted emission rate must then be multiplied by the value in the table below corresponding to the minimum distance between the industrial source and the building containing the new dwelling units to determine if the National Ambient Air Quality Standards (including the background concentrations) and AGC/SGC values in the DAR-1 guidelines are exceeded. Values are provided for 1-hour and annual averages to enable the comparison of pollutant levels to SGCs (1-hour averaging period) or AGCs (annual averaging period).

Distance from Source 1-Hour Averaging Period (ug/m 3 ) 3-Hour Averaging Period (ug/m 3 ) 8-Hour Averaging Period (ug/m 3 ) 24-Hour Averaging Period (ug/m 3 ) Annual Averaging Period (ug/m 3 ) 30 ft 124,848 61,874 46,700 38,284 5,251 60 ft 31,284 15,479 12,721 10,292 1,386 90 ft 13,936 6,884 6,098 4,858 645 120 ft 7,857 4,028 3,658 2,877 378 150 ft 5,038 2,721 2,476 1,926 252 180 ft 3,507 1,982 1,808 1,393 181 210 ft 2,599 1,520 1,390 1,063 138 240 ft 2,038 1,211 1,109 844 110 270 ft 1,684 992 910 692 90 300 ft 1,449 831 764 580 75 330 ft 1,282 714 653 496 64 360 ft 1,153 631 566 431 56 400 ft 1,015 559 477 364 47

(Added City Record 5/3/2024, eff. 6/2/2024)