§ 28-119.1. Connection of gas service utilities

Open this section

It shall be unlawful for any utility company or utility corporation to supply gas to a building, place or premises in which new meters other than replacement are required until a certificate of approval of gas installation from the department is filed with such utility company or utility corporation. When new gas service piping has been installed it shall be locked-off by the utility company or utility corporation either by locking the gas service line valve or by installing a locking device on the outside gas service line valve. The lock shall not be removed until the gas meter piping (other than utility owned) and gas distribution piping have been inspected and certified as required by the department of buildings as being ready for service.

(Am. L.L. 2024/128, 12/21/2024, eff. 12/21/2025)

Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2024/128.

§ 28-119.1.1. Gas shut-off for alterations to gas piping systems

Open this section

When alterations, extensions or repairs to existing gas meter piping or gas distribution piping require the shut-off of gas flow to a building, the utility company shall be notified by the owner or the owner's authorized representative.

(Am. L.L. 2024/128, 12/21/2024, eff. 12/21/2025)

Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2024/128.

§ 28-119.2. Temporary connection

Open this section

The commissioner shall have the authority to authorize the temporary connection of the building or system to the gas service utility.

§ 28-119.3. Authority to disconnect gas utility service

Open this section

The commissioner may authorize disconnection of gas service to the building, structure or system regulated by this code and the codes referenced in case of emergency where necessary to eliminate an immediate hazard to life or property. The department shall notify the local gas utility company, and wherever possible the owner and occupant of the building, structure or service system of the decision to disconnect prior to taking such action.

(Am. L.L. 2024/128, 12/21/2024, eff. 12/21/2025)

Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2024/128.

§ 28-119.4. Notification of gas shut-off or non-restoration after inspection

Open this section

Within 24 hours after gas service to a building is shut off by a utility company or utility corporation because of a class A or class B condition, as described in part 261 of title 16 of the New York codes, rules and regulations, and within 24 hours after gas service is, after an inspection by such a company or corporation, not restored because of such a condition, such company or corporation and the owner of such building shall each provide notice to the department in a form and manner prescribed by the department.

{L.L. 2016/154, 12/6/2016, eff. 3/6/2017)

§ 28-119.5. Connection of electric service utilities

Open this section

It shall be unlawful for any person, partnership, or corporation to supply, or cause to be supplied or used, electrical energy for light, heat, or power, signaling, alarm, or data transmission to any wiring or appliance in any building unless a sign-off or other authorization as set forth in the rules of the department authorizing the use of said wiring or appliance shall have been issued by the commissioner.

(L.L. 2024/128, 12/21/2024, eff. 12/21/2025)

Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2024/128.

§ 28-119.5.1. Authorization to energize

Open this section

An authorization to power or energize electrical wiring or appliances issued by the department shall expire 90 days after the date of issuance unless a sign-off has been issued by the department or an extension of such authorization has been granted by the department. In the event no such sign-off has been issued or extension authorization granted, the department may take action leading to the disconnecting of such meter in accordance with the notice requirements set forth in section 87.2 of the New York city electrical code.

(L.L. 2024/128, 12/21/2024, eff. 12/21/2025)

Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2024/128.

§ 28-119.5.2. Electric meter installation; restriction

Open this section

A public utility shall not supply electricity to a one-, two-, three-, or four-family dwelling, or energize more utility meters in a building than the number of distinct and separate dwelling units in such building as authorized in the certificate of occupancy applicable thereto, or if there is no certificate of occupancy, as determined by the department, without first receiving a written sign-off from the department. An owner of a one-, two-, three-, or four-family dwelling may request approval to install an additional utility meter from the department. A public utility shall not install such additional utility meter without such approval. A building with 2 or more dwelling units in accordance with the certificate of occupancy, or if there is no certificate of occupancy, as determined by the department, shall have 1 meter for each dwelling unit and may have 1 additional meter for the common areas of the building, provided that smoke detecting devices are installed in all common areas in accordance with departmental requirements. Such common areas may include boiler rooms, shared hallway lighting, shared stairway lighting, and outdoor perimeter lighting, but shall not include any habitable space. In the event that a meter has been found to have been installed or to exist in violation of this section, the utility must report such findings to the department, which may take action leading to the disconnecting of such meter in accordance with the notice requirements set forth in section 87.2 of the New York city electrical code.

(L.L. 2024/128, 12/21/2024, eff. 12/21/2025)

Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2024/128.

§ 28-119.6. Authority to disconnect electrical energy supply

Open this section

The commissioner may authorize wires or appliances to be disconnected from the supply of electrical energy and to seal the wiring and appliances after due inspection or where in the commissioner’s judgment the continued use of such electric wiring or appliances in or on any building or structure is unsafe or dangerous to persons or property.

(L.L. 2024/128, 12/21/2024, eff. 12/21/2025)

Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2024/128.

§ 28-120.1. Tenant protection plan

Open this section

A tenant protection plan shall be prepared and submitted for the alteration, construction, or partial demolition of buildings in which any dwelling unit will be occupied during construction, including newly constructed buildings that are partially occupied where work is ongoing. The tenant protection plan shall be prepared by a registered design professional and filed with the department. The registered design professional preparing the tenant protection plan shall be retained by the general contractor performing the alteration, construction, or partial demolition work. No permit shall be issued for work that requires a tenant protection plan unless such plan is approved by the department. Such plan shall contain a statement signed by the owner and signed by the applicant affirming that the building contains dwelling units that will be occupied during construction and shall identify in sufficient detail the specific units that are or may be occupied during construction, the means and methods to be employed to safeguard the safety and health of the occupants throughout the construction, including, where applicable, details such as temporary fire-rated assemblies, opening protectives, or dust containment procedures. Such means and methods shall be described with particularity and in no case shall terms such as "code compliant," "approved," "legal," "protected in accordance with law" or similar terms be used as a substitute for such description. The tenant protection plan must be site specific. The elements of the tenant protection plan may vary depending on the nature and scope of the work but at a minimum, must comply with all applicable laws and regulations, including the New York city construction codes, the New York city housing maintenance code, the New York city noise control code and the New York city health code, and shall make detailed and specific provisions for:

1. Egress. At all times in the course of construction provision shall be made for adequate egress as required by this code and the tenant protection plan shall identify the egress that will be provided. Required egress shall not be obstructed at any time except where approved by the commissioner.

2. Fire safety. All necessary laws and controls, including those with respect to occupied dwellings, as well as additional safety measures necessitated by the construction shall be strictly observed.

3. Health requirements. Specification of means and methods to be used for control of dust, disposal of construction debris, pest control and maintenance of sanitary facilities shall be included.

3.1. Lead and asbestos. Where the work involves disturbance of lead-based paint, as defined in section 27-2056.2, or paint of unknown lead content or asbestos, there shall be included a statement of compliance with applicable provisions of law relating to lead and asbestos, including whether the firm performing proposed work holds the certification or certifications required to perform such work pursuant to section 27-2056.11, and disclosure of any open violations related to lead issued by the department of health and mental hygiene or the department of housing preservation and development.

4. Compliance with housing standards. The requirements of the New York city housing maintenance code, and, where applicable, the New York state multiple dwelling law shall be strictly observed.

5. Structural safety. No structural work shall be done that may endanger the occupants.

6. Noise restrictions. Specification of means and methods to be used for the limitation of noise to acceptable levels in accordance with the New York city noise control code shall be included. Where hours of the day or the days of the week in which construction work may be undertaken are limited pursuant to the New York city noise control code, such limitations shall be stated.

7. Maintaining essential services. Where heat, hot water, cold water, gas, electricity, or other utility services are provided in such building or in any dwelling unit located therein, the tenant protection plan shall specify the means and methods to be used for maintaining such services during such work in accordance with the requirements of the New York city housing maintenance code. If a disruption of any such service is anticipated during the work, then such plan shall specify the anticipated duration of such disruption and the means and methods to be employed to minimize such disruption, including the provision of sufficient alternatives for such service during such disruption. Notification of the disruption must be given to all affected occupants of occupied dwelling units.

Exception: In the following instances, the tenant protection plan may be prepared and filed by the registered design professional of record for the alteration, construction, or partial demolition work as part of the underlying application:

1. Work in occupied one- and two-family homes.

2. Work limited to the interior of a single dwelling unit of an occupied multiple dwelling with no disruption to the essential services of other units, where such dwelling is owner-occupied. For a dwelling unit within a property that is owned by a condominium or held by a shareholder of a cooperative corporation under a proprietary lease, the unit must be occupied by the owners of record for such unit.

(Am. L.L. 2017/154, 8/30/2017, eff. 12/28/2017; Am. L.L. 2019/106, 6/8/2019, eff. 3/8/2020; Am. L.L. 2019/116, 6/8/2019, eff. 3/8/2020; Am. L.L. 2019/118, 6/8/2019, eff. 3/8/2020; Am. L.L. 2021/040, 4/18/2021, eff. 4/18/2022)

Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2017/154.

§ 28-120.1.1. Public availability of tenant protection plan

Open this section

Upon issuance of a permit for work containing a tenant protection plan, the department shall make the tenant protection plan publicly available on its website.

(L.L. 2017/154, 8/30/2017, eff. 12/28/2017; Am. L.L. 2019/106, 6/8/2019, eff. 3/8/2020)

Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2017/154.

§ 28-120.1.2. Provision of copy of tenant protection plan to occupants upon request

Open this section

The owner of a building undergoing work for which a tenant protection plan is required by section 28-120.1 shall, upon request from an occupant of a dwelling unit within such building, provide such occupant with a paper copy of the tenant protection plan approved by the department.

(L.L. 2017/154, 8/30/2017, eff. 12/28/2017; Am. L.L. 2019/106, 6/8/2019, eff. 3/8/2020)

Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2017/154.

§ 28-120.1.3. Notice to occupants

Open this section

Upon issuance of a permit for work containing a tenant protection plan, the owner shall (i) distribute a notice regarding such plan to each occupied dwelling unit and (ii) post a notice regarding such plan in a conspicuous manner in the building lobby, as well as on each floor within ten feet of the elevator, or in a building where there is no elevator, within ten feet of or in the main stairwell on such floor. The notice shall be in a form created or approved by the department and shall include:

1. A statement that occupants of the building may obtain a paper copy of such plan from the owner and may access such plan on the department website;

2. The name and contact information for the site safety manager, site safety coordinator or superintendent of construction required by section 3301.3 of the New York city building code, as applicable, or, if there is no site safety manager, site safety coordinator or superintendent of construction, the name and contact information of the owner of the building or such owner's designee;

3. A statement that occupants of the building may call 311 to make complaints about the work; and

4. Where the work involves the disturbance of lead-based paint, as defined in section 27-2056.2, or paint of unknown lead content, occupants of the building shall be directed to information regarding the hazards associated with lead-contaminated dust in a form established by the department in collaboration with the department of health and mental hygiene.

(L.L. 2017/154, 8/30/2017, eff. 12/28/2017; Am. L.L. 2019/106, 6/8/2019, eff. 3/8/2020; Am. L.L. 2021/040, 4/18/2021, eff. 4/18/2022)

Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2017/154.

§ 28-120.2. Phased tenant protection plans

Open this section

Multiple layouts of the tenant protection features enumerated in section 28-120.1 may be submitted at any time during construction operations to show phased tenant protection plan designs consistent with the phase of anticipated work. Layouts submitted subsequent to a previously approved tenant protection plan shall constitute an amendment to such plan. Such amended plan shall be approved by the department prior to the commencement of the work requiring such amended plan.

(L.L. 2019/106, 6/8/2019, eff. 3/8/2020)

§ 28-120.3. Contractor statement

Open this section

The permit holder for the underlying alteration, construction, or partial demolition shall sign a statement certifying that the tenant protection plan submitted by the registered design professional coordinates with the scope of work intended.

Exception: This statement shall not be required for:

1. Work in occupied one- and two-family homes.

2. Work limited to the interior of a single dwelling unit of an occupied multiple dwelling with no disruption to the essential services of other units, where such dwelling is owner-occupied. For a dwelling unit within a property that is owned by a condominium or held by a shareholder of a cooperative corporation under a proprietary lease, the unit must be occupied by the owners of record for such unit.

(L.L. 2019/106, 6/8/2019, eff. 3/8/2020)