63 RCNY Chapter 2 Approval of Proposed Work on Designated Buildings and Structures, part 1 of 3
§ 2-01 to § 2-14: 9 sections.
§ 2-01. Application Signatures Necessary for Work Permits
All application forms to perform any work on a designated landmark or on a property in a designated historic district must be signed by the owner of the property. An application for work on or in a cooperative building must be signed by the President or other appropriate officer of the Co-op Board. The signature of the managing agent of the cooperative building is not sufficient. An application for work on or in the areas and portions of a condominium building in common ownership must be signed by the President or other appropriate officer of the Condominium Association. An application for work on or in an individual condominium unit must be signed by the owner of that unit.
§ 2-02. Master Plans
An owner of a designated property may apply for approval of a master plan when the proposal involves repetitive alteration of architectural features (such as windows, through-wall air conditioning installations, storefronts, etc.) and when those alterations are not planned to occur all at once, but rather in increments through time. A master plan can be approved by a Certificate of Appropriateness ("CofA"), Certificate of No Effect ("CNE"), Permit for Minor Work ("PMW") or Report depending on the work which it covers. In both cases the master plan sets a standard for future changes involving the architectural features in question and specifically identifies drawings and other documents which contain the approved design in detail. Once a master plan is approved and the owner wishes to move forward with a portion of the work covered by the master plan, a completed application form is filed with the Commission describing the scope of work (for example: 8 front windows on the 12th floor) and stating that the work will conform to the approved master plan drawings and other documents on file with the Landmarks Preservation Commission. The staff of the Preservation Department will review the application to ascertain that all proposed work is covered by a master plan, and will issue a CNE, PMW or Report as required. For master plans approved by a CofA or a Commission Report, the staff shall issue a CNE, PMW or Report, depending on the type of work being proposed.
(Amended City Record 7/20/2023, eff. 8/19/2023)
§ 2-03. Process for Completing Application: Staff Withdrawal of the Application
(a) All applications for work on designated properties received by the Landmarks Preservation Commission are assigned to a professional staff member in the Preservation Department who will handle the project. The staff person will review the proposal to ascertain whether the materials submitted are sufficient for a determination to be made. If the materials are sufficient, staff will certify the application as complete and issue the appropriate permit or take other action. If the completed application requires a Certificate of Appropriateness, staff will arrange for the item to be included in the next scheduled Certificate of Appropriateness public hearing calendar. If the application requires further clarification and/or additional documentary materials, staff will contact the owner and/or applicant by telephone to discuss the proposal and, if necessary, arrange a meeting or site visit. Staff will follow the conversation up by providing a materials checklist calling out those supplementary materials required to certify the application as complete. If contact has been limited to a telephone conversation, the checklist will be mailed to the applicant. If a meeting is set up, the checklist may be supplied during the course of the meeting. As soon as all the materials requested have been received, staff will certify the application as complete and process the application. However, if the required materials have not been received 60 working days from the date on the materials checklist, staff will send a follow-up letter to the applicant reminding him/her that the application is still incomplete and informing him/her that unless the materials required are received within the next 30 working days the application will be deemed withdrawn. A copy of the most recent materials checklist will be included with the letter. If the applicant does not submit sufficient material within 90 days of the date on the materials checklist, staff should withdraw the application by sending a staff withdrawal letter including the docket number of the application and a "Withdrawn at Staff Level" number generated by "Permit Application Training System". The application will then be closed. The staff withdrawal letter will be sent to the owner and applicant with copies forwarded to the file, supervisor, and the Director of Preservation. Along with the withdrawal letter a blank "Application for Work on Designated Properties" will be included for the use of the applicant should he or she wish to re-apply.
(b) Notwithstanding the time periods set forth in subdivision (a), where an application seeks to legalize or cure a violation, an applicant must submit all materials required by the materials checklist within 20 working days of the date of the materials checklist. If the materials are not submitted, the staff shall send a follow-up letter that shall inform the applicant that the application may be withdrawn by the staff unless all required materials are submitted within 15 working days of the date of the follow-up letter. If the applicant fails to submit all required materials within 55 working days of the date of the first materials checklist, the staff may withdraw the application as set forth in subdivision (a). Withdrawal of an application to legalize or cure a violation, in whole or in part, shall be deemed a disapproval for purposes of service of a second or subsequent notice of violation pursuant to Administrative Code § 25-317.1(b)(4)(a)(ii).
§ 2-04. Summonses – New Applications
The Landmarks Preservation Commission will not process an application for work on a designated property when a Landmarks Preservation Commission Summons is in effect against that property. A Summons in effect against that property indicates non-compliance with the Landmarks Law. With respect to Title 63 of the Rules of the City of New York and §§ 25-301 through 25-322 of the Administrative Code, the term "Summons" will be construed to include and apply to any previously issued "Notice of Violation."
(a) Effect of a Summons on Processing of a New Application. Upon receipt of an application, LPC Staff must verify that no Summons is in effect against the property. If a Summons is in effect, LPC Staff will:
(1) Obtain copies of all Summonses, previously issued Notices of Violation and Notices to Stop Work for the file.
(2) Contact the owner/applicant to inform them that because a Summons is in effect LPC Staff cannot process an application for new work until the Summons has been rescinded.
(3) Send a letter to the applicant explaining that LPC Staff cannot process the new application because a Summons is in effect against the property, that processing can only commence upon rescission of the Summons or when the applicant begins to address the conditions described in the Summons. Along with the letter send copies of the Summons, an application form, and instructions for filing. Send copies of the letter to the Supervisor, and the Director of Enforcement.
(b) Exceptions to this Procedure. LPC Staff may issue permits for new work when a Summons is in effect in the following instances:
(1) The proposed work will correct a hazardous condition.
(2) The proposed work will address deterioration affecting the building, and the work will clearly further the continuing preservation of the building.
(3) A permit has been issued to correct work cited in a Summons, and an escrow agreement or other acceptable form of assurance has been established to provide a mechanism, acceptable to the Landmarks Preservation Commission, that ensures that the corrective work approved under the permit to address the Summons will be completed within a specified time period.
(Amended City Record 12/20/2018, eff. 1/19/2019)
§ 2-05. Temporary Installations
LPC Staff is authorized to approve and issue a Certificate of No Effect (CNE) or Permit for Minor Work (PMW) for proposals calling for the temporary installation of signs, banners or other temporary installations such as various forms of artwork or kiosks, if the following criteria are met:
(a) "Temporary Installation" is defined as an installation for one hundred eighty (180) days or less for signs and banners or one (1) calendar year or less for other temporary installations. The duration of any temporary installation authorized under this rule will be specified in the CNE or PMW. Any temporary installation must be for a single period not to exceed one hundred eighty (180) days for signs and banners or one (1) calendar year for other temporary installations. An approval for a temporary installation cannot be renewed pursuant to 63 RCNY Chapter 7, nor shall such installation be the subject of a subsequent application for a temporary approval. However, approvals of temporary installations related to approved construction on the property and temporary installations on publicly owned properties may be renewed for up to two additional installation periods. With respect to temporary installations related to approved construction on the property, LPC Staff will make a determination, prior to renewing the approval, that the project is proceeding with reasonable promptness; and
(b) The installation will cause no damage to protected architectural features of the property; and
(c) An acceptable plan and time schedule for the dismantling of the installation has been submitted to the Commission as a component of the application, along with specifications for any repair work that might be required after dismantling of the installation. In the case of artwork, the applicant is also required to submit a written instrument signed by the artist and the building owner that evidences the owner's authority to remove the artwork when the temporary installation permit expires and that waives any protection under applicable federal or state law afforded to the artist or artwork that would prevent such removal at the expiration of the temporary permit, including but not limited to, the Visual Artists Rights Act of 1990, 17 U.S.C. §§ 101 et seq. and Article 14 of the New York State Law on Arts and Cultural Affairs; and
(d) With respect to temporary installations related to approved construction work, an acceptable plan for dismantling, storing and reinstalling any significant features that had to be removed to perform such work has been submitted to the Commission; and
(e) If the applicant is not a public or quasi-public agency, an escrow agreement or other adequate assurance acceptable to the Commission is provided to establish that a mechanism is available for the removal of the installation upon expiration of the permit should the applicant fail to remove the installation.
(f) The time period for an approval of a temporary installation will commence upon issuance of the temporary permit, unless the approval explicitly provides for a different commencement date.
(Amended City Record 12/20/2018, eff. 1/19/2019)
§ 2-11. Repair, Restoration, Replacement and Re-creation of Building Facades and Related Exterior Elements
(a) Introduction. This section authorizes LPC Staff to approve applications for work to repair, restore and re-create building facades and related exterior elements in order to maintain, restore, replace, re-create and, in certain instances, recall original or historic exterior architectural elements. LPC Staff reviews these applications with the presumption that historic materials should be maintained, repaired and replaced in-kind whenever possible. This approach results in the most authentic and sympathetic interventions and preserves the design, materiality and engineering of the historic building or improvement and its features. Furthermore, the use of historic materials and methods typically ensures compatibility with surrounding materials in terms of expansion and contraction, permeability and absorption, and structural capacity, among other things. Most historic material are proven to be long-lasting and durable when properly maintained, and will age and perform in a predicable way in support of the long-term economic viability of their continued use. Notwithstanding the preference for original and historic materials, LPC Staff may consider alternative repair methods and substitute materials in certain situations as set forth in this subdivision, while in other situations use of substitute materials is prohibited.
For purposes of this section, the term "primary facade" means: (1) a facade fronting a street or public thoroughfare that is not a street, such as a mews or court; (2) A visible facade that possesses a level of design or significant architectural features that are commensurate with the building's street-fronting facade(s), and where such facade (i) faces but does not front a street, such as a setback facade, or (ii) is part of a dominant massing element where at least one facade is street-fronting or street-facing, such as a tower element; or (3) A facade with a primary entrance to the building.
(b) General Conditions and Requirements.
(1) Probes and other investigative work. No permit is required for non-intrusive investigative work or probes, provided the work is fully reversible and does not damage any historic fabric, and further provided that the existing condition is reinstated upon completion. LPC Staff may approve and issue an approval for selective intrusive investigative work or probes in order to assess the current condition of building materials and systems, or for the temporary removal of a feature or portion of a feature in order to make a mold for replication, if the proposed work meets all of the following applicable criteria:
(i) The probes or removal(s) are requested in connection with an anticipated or open application for work, or for an approval that has been granted;
(ii) No more material will be removed than is necessary to discover the underlying condition or make the mold for replication and, where possible, removal will be limited to non-character defining features and materials;
(iii) The probe(s) or removal(s) will be performed in an unobtrusive location;
(iv) Temporary protection of the area being probed will be provided; and
(v) Where original fabric is removed in connection with the probe, it will be re-installed to match the original condition, or if necessary the material will be replaced in-kind. For removals in connection with making a mold for replication, the original fabric will be re-installed or adequate protective measures will be taken to ensure that the facade is kept watertight until such time as the reinstallation or replacement of the feature is complete.
(2) Documentation and assessment of deteriorated conditions. The applicant must provide current photographs of the building as documentation of deteriorated conditions, along with a written scope of work summary. Where replacement of large quantities of materials and/or significant architectural features is proposed, the applicant must provide an assessment of the deteriorated conditions warranting such replacement(s). Repair will be given priority over replacement if feasible.
(3) Physical and aesthetic characteristics of materials and features. In all cases, except where noted, the repair, restoration, replacement or re-creation must match the original or historic materials and features in terms of its physical and aesthetic characteristics, including design, detail, profile, dimension, material, texture, tooling, dressing, color and finish, as applicable.
(4) Specifications. The specifications, methods and materials for the repair, restoration, replacement or re-creation must be identified and described by the architect, engineer or contractor as part of a written scope of work or specifications manual or on the filing drawings.
(5) Samples. LPC Staff may, prior to commencement of the work and as a condition of approval or as a stipulation for continuing work, require that samples of work, including samples of materials, methods and finishes, be prepared for review and approval. The applicant may notify the LPC Staff by letter or email that the samples are ready for review. LPC Staff may request photographs of the samples or delivery of the samples to the LPC Staff member prior to the site visit. Work may not commence or proceed until LPC Staff has approved the sample(s). With respect to a request for samples:
(i) Samples of joint preparation for repointing work at primary facades of a small size and at locations requiring repointing will be provided prior to raking or cutting the entire facade(s);
(ii) The applicant must provide at least two (2) samples of pointing, masonry repairs, and/or replacement unit masonry, of a size to be determined by LPC Staff, and the samples must be located at areas requiring the repairs where reasonable and feasible;
(iii) Samples must be adequately set or dried prior to photographing or contacting LPC Staff to arrange for a site inspection;
(iv) Samples approved by LPC Staff will serve as the standard for the entire job; and
(v) For certain scopes of work, such as large amounts of masonry replacement or facade reconstruction, LPC Staff may require a separate sign-off of the samples, including stopping work and submission of photographs or a site visit, once a portion of the work, as stipulated by LPC Staff, has been completed.
(6) Shop drawings. LPC Staff may, prior to issuance of a permit, or prior to commencement of the work and as a condition of approval or as a stipulation for continuing work, require the submission and approval of shop drawings for the in-kind replacement of significant architectural features.
(7) Environmental conditions. The repair, restoration, replacement, or reconstruction of mortar joints and unit masonry will be performed only when the temperature remains at a constant 45 degrees Fahrenheit or above for a 72-hour period from the commencement of the work. Other means and methods for providing a comparable controlled environment, such as providing heated enclosures or heating the material itself, may be considered on a case-by-case basis subject to review and approval by LPC staff.
(c) Repair or Restoration of Facade Materials and Features. Where the applicant has provided documentation, assessment, and specifications, as applicable, LPC Staff will approve repair or restoration of deteriorated facade materials and features as provided below.
(1) Cleaning and removal of paint and coatings. LPC Staff will approve cleaning and removing paint and coatings from exterior masonry and cast iron facades if the proposed work meets all of the following applicable criteria:
(i) Cleaning and paint removal products and methodologies will provide for the gentlest effective method to avoid causing damage to the masonry; and
(ii) Water pressure will be the lowest necessary to clean and remove paint or coatings and will not exceed 300 psi for cast iron or 500 psi for masonry.
(2) Painting and coating of facades.
(i) Painting facades and features that were originally or historically painted and are currently unpainted. LPC Staff will approve painting facades and building features that historically were painted in order to protect them from damage or return them more closely to their historic appearance if the proposed work meets all of the following applicable criteria:
(A) The paint will match original or historic paint in terms of physical and aesthetic characteristics, and the color will be in keeping with the historic color palette of the building's type, style, and age, except that in the case of historic masonry the proposed color will match the color of the underlying masonry, unless the color is part of a significant later alteration. For Individual Landmarks, if a substantial portion of the paint on a primary facade is being removed, the applicant must perform a paint analysis unless one already exists;
(B) A particular finish that is already required pursuant to an LPC Modification of Use or Bulk, or was an important criterion for an approval of a Certificate of Appropriateness application, will be maintained.
(ii) Painting non-original or altered features or facades. LPC Staff will approve the painting of facades or features that are not original, or were altered or damaged prior to designation, in order to improve their appearance or conceal non-original materials, if the proposed work meets all of the following applicable criteria:
(A) The paint will blend with the surrounding materials, helping the feature recede from view; or
(B) The paint will be harmonious with other elements on the building or adjacent buildings, thereby helping unify the appearance and relationship of the elements.
(C) Repainting a facade or feature to match the existing condition does not require a permit, provided the existing condition is grandfathered or approved by the Commission. Any perceptible change in color will require a permit, subject to the conditions set forth in paragraph (2)(A) and (B) of this subdivision. See subparagraph (iii) below for use of non-paint coatings, as applicable.
(iii) Coating masonry facades and features. LPC Staff will approve coating masonry facades and building features with non-paint material, such as a mineral coating or stain that is absorbed into the substrate and/or bonds with it, in order to protect them from damage, if the proposed work meets all of the following applicable criteria:
(A) Water infiltration has occurred or is occurring through the facade or feature due to its deteriorated surface condition; or
(B) The base of the facade has been subjected to graffiti on a recurring basis; and
(C) The coating will be highly breathable, and in most cases will be clear with a dull finish to maintain the appearance of the underlying masonry unless some coloration is desirable to conceal prior non-matching repairs or surface damage; and
(D) The coating will not be a waterproofing product, unless such product already exists on the building facade or feature and cannot be removed without damaging the underlying material, and the scope of recoating is limited to touching up small areas. A larger scope of recoating, or complete recoating, may not be approved if there is potential for diminishing breathability and damaging the facade or feature due to build-up of multiple layers of the coating.
(3) Pointing of mortar joints. LPC Staff will approve raking, cutting and pointing mortar joints with a cementitious mortar mix, if the proposed work meets all of the following applicable criteria:
(i) The mortar will match original or historic mortar in terms of physical and aesthetic characteristics. For Individual Landmarks a mortar analysis must be performed if a substantial amount of the primary facade is being repointed;
(ii) The mortar type will be of a strength less than, and permeability greater than, that of the masonry unit, and the mortar mix will typically consist of lime, white or gray Portland cement, and sand, plus pigments as required;
(iii) If the facade has been previously pointed in a color, texture or tooling not matching the original or historic mortar, and only limited areas of the facade require repointing, the mortar may match the existing mortar;
(iv) If the majority of mortar joints have been previously widened by improper cutting to the extent that it changes the character of the brickwork, the mortar may be an alternative color, texture or tooling that helps to unify the appearance of the facade; and
(v) The joints will be raked by hand without power tools, except that wide joints may be mechanically cut with power tools if specifications for execution are provided to ensure there will be no over-cutting into masonry or widening of mortar joints which would cause irreversible damage to the brick.
(4) Repair of natural and cast stone. LPC Staff will approve the repair of natural and cast stone (concrete mixtures that employ molded shapes, decorative aggregates, and masonry pigments to simulate natural stone) elements if the proposed work meets all of the following applicable criteria:
(i) For rusticated stone, special decorative elements, and types of stone which are difficult to recreate with a cementitious patch, LPC Staff will approve an application to reset, re-tool or consolidate the significant fabric, or install Dutchmen. As used in this subparagraph, the term "Dutchman" refers to any new or matching salvaged stone fitted into the existing facade stone as follows:
(A) The Dutchman repair will match original or historic stone in terms of its physical and aesthetic characteristics; and
(B) Materials and methods for adhesives and/or anchoring will be compatible with the stone, and will be discreet or concealed from view.
(ii) For other types of stone, LPC Staff will approve an application to remove the original stone surface and patch or resurface it with a cementitious mix, if the proposed work meets all of the following applicable criteria:
(A) The deteriorated portions of the stone will be cut back to sound stone and the new surface keyed into the sound stone with a tinted cementitious patching compound or built up in successive layers using a cementitious mix with the top layer tinted, and will match original or historic stone in terms of its physical and aesthetic characteristics;
(B) Materials and methods for anchoring will be compatible with the stone and the cementitious patching compound or mix, and will be discreet or concealed from view.
(5) Repair of fired clay and ceramic unit masonry (including brick and terra cotta). LPC Staff will approve an application to repair brick, glazed terra cotta or other fired unit masonry surfaces if the proposed work meets all of the following applicable criteria:
(i) Repairs will match the original or historic brick or terra cotta in terms of physical and aesthetic characteristics;
(ii) Repairs are limited to minor spalling or chipping of the brick or terra cotta glazing;
(iii) Deteriorated areas of glazing are painted with a compatible coating to match the original glaze finish.
(6) Repair of stucco. LPC Staff will approve an application to repair stucco elements and surfaces, including any underlying wood or metal lathe, if the proposed work meets all of the following applicable criteria:
(i) The stucco or cementitious patching compound will match original or historic stucco in terms of physical and aesthetic characteristics;
(ii) Materials and methods for anchoring, fasteners, control or expansion joints, and/or sealants will be compatible with the stucco and the underlying material, and will be discreet or concealed from view.
(7) Repair of ornamental sheet metal. LPC Staff will approve an application to repair sheet metal elements by removing, repairing and reinstalling existing elements, if the proposed work meets all of the following applicable criteria:
(i) The sheet metal repair will match original or historic ornamental sheet metal in terms of physical and aesthetic characteristics; and
(ii) Materials and methods for anchoring, fasteners, soldering, patching, filling and/or sealants will be compatible with the ornamental sheet metal, and will be discreet or concealed from view.
(8) Repair of cast and wrought iron and other cast or extruded ornamental metals. LPC Staff will approve an application to repair cast, wrought or extruded metal elements by removing, repairing and reinstalling existing elements, if the proposed work meets all of the following applicable criteria:
(i) The cast, wrought or extruded metal repair will match original or historic cast and wrought iron and other cast or extruded ornamental metals in terms of physical and aesthetic characteristics;
(ii) Materials and methods for anchoring, fasteners, welding, patching, filling and/or sealants will be compatible with the cast and wrought iron and other cast or extruded ornamental metals, and will be discreet or concealed from view.
(9) Repair of wood features. LPC Staff will approve an application to repair wood elements by removing, repairing and reinstalling existing elements, if the proposed work meets all of the following applicable criteria:
(i) The wood repair will match original or historic wood in terms of physical and aesthetic characteristics; and
(ii) Materials and methods for anchoring, fasteners, patching, filling, piecing-in ("Dutchmen" repairs), consolidating, or other reinforcement will be compatible with the wood, and will be discreet or concealed from view.
(10) Repair of other materials. LPC Staff will approve the repair of other materials or building facades that do not fall into any of the previously described categories, including but not limited to laminates, plastic and synthetic rubbers, curtain walls, and poured concrete, if the repair will match original or historic material in terms of physical and aesthetic characteristics. In connection with such repairs, LPC Staff may approve the repair of minor portions of these other materials with substitute materials that otherwise match the physical and aesthetic characteristics, provided the use of substitute materials will not detract from the original materials.
(d) Replacement of Deteriorated Architectural Features. Where the applicant has provided adequate documentation and assessment that an architectural feature cannot be repaired and retained, typically in the form of a descriptive analysis and photographic and/or other evidence, LPC staff will approve replacement of such a feature as provided below. For purposes of this subdivision, "architectural feature" means both the individual components (e.g., cornice, lintel, band course or column) and the material (e.g., brick, stone, wood or terra cotta) that comprise the basic facade material.
(1) Criteria.
(i) Replacement materials and features should match the original or historic material or feature in terms of physical and aesthetic characteristics. For purposes of this subdivision, this means that replacement material should be "in-kind" in terms of using the actual original or historic material and installation techniques. In-kind replacement should be prioritized and fully considered prior to proposing substitute materials.
(ii) Materials other than the original or historic material (hereinafter "substitute materials") may be approved in some cases where the substitute material matches or recalls the appearance of the original or historic material in terms of texture, finish, color and details, with the expectation that it will be long-lasting and maintained, provided the substitute material and installation methods do not directly or indirectly damage the surrounding original or historic material, the substitute material and/or its installation methods are not discernible or otherwise call attention to the work, and as provided for, and limited by, this subdivision and subdivisions (e) and (f). Unless otherwise authorized, a substitute material may not be used to replace all or a substantial portion of an entire facade. LPC Staff may request a written explanation describing the reason(s) for proposing to use a substitute material in lieu of an in-kind replacement.
(iii) Substitute materials may not be used at buildings seeking or subject to a special permit ("Modification of Use and Bulk" or "MOU"), except where the approval requires or anticipates the use of substitute materials, and except if the original or historic material is no longer commercially available and replacement in-kind is infeasible. In addition, substitute materials may not be used on a building or portions of a building where in-kind replacement was an important aspect of an approval of a Certificate of Appropriateness application.
(iv) Requirements for the replacement of historic materials in-kind and the use of substitute materials are as follows:
(A) Cast iron. Replacement of cast iron with a painted finish must be in-kind at or below the sixth story at the primary facade(s), except that cast aluminum or another cast metal with a painted finish may be used. In addition to these provisions, above the sixth story at primary facade(s) and at secondary facades, substitute materials may also be used for limited quantities of discrete elements. At Individual Landmarks, substitute materials may not be used.
(B) Cast metals and sheet metals. Replacement of cast metals and sheet metals with a natural finish, and wrought metals, must be in-kind at or below the sixth story at the primary facade(s). Above the sixth story at primary facade(s), substitute materials may be used. At Individual Landmarks, substitute materials may not be used.
(C) Brick and stucco. Replacement of brick and stucco must be in-kind at any location on the building. At Individual Landmarks, substitute materials may not be used.
(D) Cast and natural stone. Replacement of (historic) cast stone and natural stone (other than brownstone) must be in-kind at or below the sixth story at the primary facade(s), except substitute materials may be used for coping elements. In addition to these provisions, above the sixth story at primary facade(s), substitute materials may also be used at projecting cornices and balconies with weight and/or attachment issues when in-kind replacement has the potential to cause additional loss of surrounding materials, as determined by a licensed engineer; and for limited quantities of other discrete elements that are not part of a cladding field of similar units where physical and visual compatibility is critical. At Individual Landmarks, substitute materials may not be used, except for coping elements.
(E) Brownstone. Replacement of brownstone may be in-kind at the primary facade(s), or cast stone may be used for facade elements and features, and cast stone or stucco over backup masonry may be used at stoops and areaway walls. At Individual Landmarks, stucco over backup masonry may not be used.
(F) Terra cotta. Replacement of terra cotta must be in-kind at or below the sixth story at the primary facade(s), except substitute materials may be used for coping elements, as well as for limited quantities of other discrete elements that are not part of a cladding field of similar units where physical and visual compatibility is critical. In addition to these provisions, above the sixth story at primary facade(s), substitute materials may also be used at projecting cornices and balconies with weight and/or attachment issues when in-kind replacement has the potential to cause additional loss of surrounding materials, as determined by a licensed engineer. At Individual Landmarks, substitute material may not be used, except for coping elements, as well as for limited quantities of other discrete elements that are not part of a cladding field of similar units where physical and visual compatibility is critical.
(G) Wood siding. Replacement of wood siding must be in-kind at the primary facade(s) and at Individual Landmarks, except that fiber-cement board may be used only if applicable building, fire or other code(s) prohibit the use of wood siding, provided the use of the substitute material is the minimum required by such code(s).
(H) Painted wood and sheet metal. Replacement of painted wood and sheet metal elements must be in-kind at the primary facade(s), except that painted wood and sheet metal elements may be used interchangeably at facade elements that were historically used in a similar manner, such as cornices and bay windows; and other substitute materials may be used at elaborate top floor cornices less than 25 feet in length where any joints in the material would be hidden or obscured by the design elements. Above the sixth story at primary facade(s), substitute materials may be used. At Individual Landmarks, substitute materials may not be used.
(I) Roofing material. Replacement of original or historic roofing, flashing, gutters, leaders, and/or decorative elements, or replace roofing where the original or historic roofing material has been removed, must meet all of the following applicable criteria:
(a) The new roofing components will match the original or historic roofing components in terms of their physical and aesthetic characteristics; or
(b) If the original or historic roofing is existing, LPC Staff may approve a substitute material at roofs of buildings six stories tall or less at the primary facade if the material is not visible from a public thoroughfare. For buildings seven stories tall or greater, substitute materials may be used at the primary and secondary facades if the material is not visible or minimally visible from a public thoroughfare, where because of the height or discreet presence the substitute material will not be discernible or will not call attention to itself or detract from the significant historic features of the building, or district if the building is in a historic district. In all cases, new visible flashing, gutters, leaders and/or decorative elements will match the original or historic materials. All substitute materials must satisfy the criteria of clause (c) below. This clause (b) does not apply to Individual Landmarks or buildings seeking or subject to a special permit ("Modification of Use or Bulk" or "MOU").
(c) If the original or historic roofing is missing, LPC Staff may approve a substitute material that recalls, but does not necessarily match, the original or historic roofing in terms of its visual characteristics (including artificial slate or clay shingles, architectural asphalt shingles, and "solar shingles", which are designed to look like and function as conventional roofing material while also producing electricity), if the substitute material will not call attention to itself or detract from the significant historic features of the building, or district if the building is in a historic district, provided that any new visible flashing, gutters, leaders and/or decorative elements will match the original or historic materials. This clause (c) does not apply to buildings seeking or subject to a special permit ("Modification of Use or Bulk" or "MOU"). For purposes of this clause (c):
(1) If the existing roofing material is asphalt shingles, the new roofing material can be asphalt shingles provided it is an architectural shingle that better recalls the historic roofing material; and
(2) Standing seam metal roofing may be replaced in kind.
(d) If the roof is a flat roof, no LPC permit is required to replace the flat roof, including proposals to install or increase insulation as part of the replacement. However, any alterations or replacement of visible flashing, gutter, leaders and/or decorative elements, or raising or installing of visible railings, associated with the flat roof replacement will be subject to LPC Staff and Commissioners' review and must meet applicable criteria as identified in this section.
(J) Where a substitute material has previously been approved as an aspect of a Certificate of Appropriateness application, LPC Staff may continue the use of the same or other comparable substitute material in new applications for the same building or structure consistent with that approval, provided the substitute material has proven to be an acceptable match in terms of appearance and compatibility over time with the surrounding original or historic material.
(v) Except as otherwise prohibited by the criteria of this subdivision, substitute materials may be approved at any location on a secondary facade not fronting on a publicly accessible thoroughfare if the substitute material will not be discernible or will not call attention to itself or detract from the significant historic features of the building, or district, if the building is in a historic district.
(e) Reconstruction of Facades. For buildings in historic districts, if the entire facade cannot be stabilized and repaired in-place, the applicant must provide a structural conditions report from a licensed professional engineer, an assessment of the existing materials and potential for unit masonry and other features to be salvaged and re-used, and fully-dimensioned survey drawings of the facade. The recommendation for reconstruction of a primary facade made by the engineer will be subject to peer review by an structural engineer contracted with by the Commission, who must concur with the recommendation in order for LPC staff to approve the application. Historic facade material must be salvaged and reused to the greatest extent feasible at primary facades. This subdivision (e) does not apply to Individual Landmarks or buildings seeking or subject to a special permit ("Modification of Use and Bulk" or "MOU").
(1) The facade must be reconstructed in kind in terms of wall construction, including full-width brick and stone at the outer wythe, except that back-up masonry can be either brick or concrete masonry units. Existing modified architectural features that are not significant later alterations must be recreated to match their original or historic appearance at primary facades and visible secondary facades. For example, if the lintels or sills have been stripped, and the modification is not a significant later alteration, the proposal must include recreating the original or historic sills or lintels. Substitute materials may be employed in recreating these historic details, as provided for by subdivision (d).
(f) Re-Creation and Restoration of Missing Facade Features. LPC Staff will approve the re-creation and restoration of building facade element(s) (including but not limited to roofs and cornices, stoops, storefronts, window and door openings, window and door enframements, ironwork, porches and siding) to their original or historic appearance if they determine that the proposed work satisfies the following conditions:
(1) The restoration would not cause the removal of original fabric or significant historic fabric (such as Victorian period features on an earlier structure) that may have been added over time, and the authenticity of the restoration is documented by:
(i) Photographic evidence;
(ii) Physical evidence on the building;
(iii) Original or historic drawings or documents; or
(iv) Matching buildings.
(2) If there is no available documentary evidence as described in paragraph (1) of this subdivision, the design of the missing feature, including its physical and aesthetic characteristics, may be based on that found on buildings of a similar age and style that contain stylistic elements that follow a set pattern or type, in consultation with LPC Staff. This provision does not apply to Individual Landmarks or buildings seeking or subject to a special permit ("Modification of Use and Bulk" or "MOU").
(3) Materials for re-creating and restoring missing facade features must match the original or historic materials in kind or be a substitute material that meets the requirements of subdivision (d) of this section.
(4) The work will not result in the substantial reconstruction of the facade, unless also meeting the requirements of subdivision (e).
(Amended City Record 12/20/2018, eff. 1/19/2019)
§ 2-12. Storefronts, Awnings and Canopies
(a) Definitions. As used in this section, the following terms have the following meanings:
Awning. "Awning" means a metal frame clad with fabric attached above or within an opening, or within an integral housing, at a window, door, porch or storefront to provide protection from the weather.
Back-of-house programming. "Back-of-house programming" means that part of a commercial or manufacturing establishment not intended for display, public use or viewing, such as food preparation, security, storage and/or employee areas.
Bulkhead. "Bulkhead" means the part of the storefront that forms a base for one or more display windows.
Canopy. "Canopy" means a metal frame clad with fabric that extends from a building entrance over the sidewalk to the curb, where it is supported on vertical posts.
Display window. "Display window" means the large glazed portion of the storefront infill, and the associated framing, above the bulkhead and below the transom, extending pier to pier. The display window is typically used for the display of goods and to provide daylight and visibility into the commercial space.
Facade. "Facade" means an entire exterior face of a building. See "primary facade" definition below.
Fixed awning. "Fixed awning" means an awning with a non-retractable metal frame clad with fabric.
Historic fabric. "Historic fabric" means a building's original or significant historic facade construction material or ornament, or fragments thereof.
Historic Storefront. "Historic storefront" means the visual appearance of a storefront as originally built or at a point in time after it has undergone alterations or additions that enhance or contribute to the building's or site's special architectural, aesthetic, cultural or historic character.
Landmarks Law. "Landmarks Law" refers to Section 3020 of the Charter and Chapter 3 of Title 25 of the Administrative Code of the City of New York.
Lintel. "Lintel" means the horizontal member or element above a door, window or storefront opening.
LPC staff. "LPC staff" means the staff of the Landmarks Preservation Commission acting in the Commission's agency capacity.
Pier. "Pier" means an exterior vertical member(s) or element(s), usually of brick, stone or metal, placed at intervals along a wall that typically separates storefront openings within a single building or define a single storefront opening.
Primary facade. "Primary facade" means a facade facing a street or a public thoroughfare that is not necessarily a municipally dedicated space, such as a mews or court.
Residential awning. "Residential awning" means any awning on a residential building and any awning on a commercial or mixed-use building except for storefront awnings.
Retractable awning. "Retractable awning" means an awning attached to a frame which allows it to be extended out or folded or rolled back tight against the building facade.
Roll-down gate. "Roll-down gate" means a security gate with a retracting mechanism that allows it to roll up and down.
Security gate. "Security gate" means a movable metal fixture installed in front of a storefront opening or bay, or inside the display window or door, to protect the store from theft or vandalism when the store is closed.
Security gate housing (or housing). "Security gate housing," or "housing," means the container that houses the rolling mechanism of a roll-down security gate.
Security gate tracks. "Security gate tracks" means the interior or exterior tracks along the sides or top and bottom of the storefront opening or bay that hold the edges of the roll-down gate.
Serving window. "Serving window" means an operable storefront display window, or window assembly within a larger window or assembly, that allows direct commercial interaction between the public and the purveyor of goods or services.
Significant feature. "Significant feature" means an exterior architectural component of a building that contributes to its special historic, cultural, and/or aesthetic character, or in the case of an historic district, that reinforces the special characteristics for which the historic district was designated.
Skirt. "Skirt" means a bottom finishing piece of fabric that hangs from the lower edge of an awning.
Storefront. "Storefront" means the first or second story area of the facade that provides access or natural illumination into a space used for retail or other commercial purposes.
Storefront bay. "Storefront bay" means the area of a storefront defined by and spanning two piers.
Storefront infill. "Storefront infill" means the framing, glazing and cladding contained within a storefront opening in the facade, including but not limited to display windows, bulkheads and entranceways.
Storefront opening. "Storefront opening" means the area of the facade between the piers and lintel which contains storefront infill. Steps and platforms in front of, and leading up to, an entry door are not part of the storefront opening.
Storefront surround. "Storefront surround" means decorative elements or treatment on the facade around the storefront opening.
Transom. "Transom" means the glazed area above a display window or door separated from the display window or door by a horizontal framing member ("the transom bar"). The glazing in the transom may be fixed or operable.
Terms not otherwise defined in these rules have the meanings given them in the Landmarks Law.
(b) General.
(1) Type of storefront work. This section sets forth criteria and other standards for proposals for new storefronts that are not re-creations or restorations of original or historic storefronts, which instead are addressed in 63 RCNY § 2-11(f).
(2) Related storefront work. Storefront work often involves other work that is covered by different sections of the Commission's rules. Specifically, applicants for new storefronts and storefront components may also want to consult the following rule sections for the applicable standards:
(i) Signage. The design and installation of signage and lighting must meet the criteria set forth in 63 RCNY § 2-13.
(ii) Heating, venting and air-conditioning. The installation of heating, venting and air conditioning equipment and grilles must meet the criteria set forth in 63 RCNY § 2-21.
(iii) Restoration of storefront facade features. Restoration of storefronts and specific architectural features must meet the criteria set forth in 63 RCNY § 2-11(f).
(iv) Barrier-free access. Work to make storefronts accessible must meet the criteria set forth in 63 RCNY § 2-18.
(3) This section does not apply to:
(i) Individual landmarks, except where specifically indicated.
(ii) Buildings subject to a building or district master plan, or other special rule approved by the Commission, governing the installation and characteristics of a storefront or awning.
(iii) Buildings with three or more uniform storefront openings, where the Commission after a Public Hearing already has approved a new storefront but not a storefront master plan
(iv) Awnings on windows that, due to their shape, size or location, will result in an awning that will detract from the special architectural features of the building.
(4) No permit is required for the following types of ordinary repair and routine maintenance work on awnings:
(i) Seasonal removal and installation of Commission approved window awnings;
(ii) Fabric patching in a matching material;
(iii) Minor repairs or adjustments to the rolling or folding arm mechanism of an awning's frame; and
(iv) Cleaning of awning material.
(c) Storefront Infill. LPC Staff will issue an approval for new storefront infill for existing storefront openings, including openings that have been infilled, for buildings in historic districts that were designed with storefronts, and buildings that were altered historically by the construction of ground floor storefronts, and at service entrances as provided in paragraph (7)(iii) of this subdivision, where no significant historic fabric exists, if the proposed work meets all of the relevant criteria set forth below:
(1) Design. The design of the new infill matches the original or historic appearance determined pursuant to the requirements of 63 RCNY § 2-11(f)(1) or is based on historic storefront prototypes and details within the specific historic district and for buildings of similar age, type and style, except that storefront infill for a building that already has storefront infill approved pursuant to this section must match the previously approved storefront infill in terms of the location, design and materials of piers, the proportions of the elements of storefront infill and finish, but allowing for minor variations in detail and finish. If the building contains three or more uniform storefronts and at least one of the storefronts contains most of its historic elements, a new storefront must match the historic design pursuant to the requirements of 63 RCNY § 2-11(f)(1). Where the historical, architectural or cultural significance of the building or storefront is reflected in changes to the storefront after the initial construction, the new storefront may be required to match the historic appearance as represented by such changes pursuant to the requirements of 63 RCNY § 2-11(f)(1). In all cases the design may be modified to make the storefront meet accessibility requirements.
(2) Configuration. The configuration of the new infill is consistent with the proportions of display windows, transoms (if necessary, given the size of the display windows) and bulkheads of historic storefront infill.
(3) Display windows.
(i) Display windows must be fixed, except that the new infill may consist of operable doors and/or operable windows over a fixed bulkhead provided:
(A) Operable doors feature bottom rails that match the height, and maintain the design intent, of storefront bulkheads required by subdivision (6) of this section;
(B) Operable windows are installed over storefront bulkheads required by this section;
(C) The infill includes either mullions, piers, fixed display windows, or a combination of these elements to avoid creating the appearance of a void at the base of the building when the storefront windows and doors are open; and
(D) The width of individual operable doors or windows are as large as practicable, and when closed the operable doors or windows will read as display windows over a bulkhead and will maintain a sense of transparency at the base of the building. In the case of a serving window, such window is no larger than fifty (50) percent of the width of the storefront bay, and any mullion or other structural element necessary to accommodate the operable window must match the material and finish of, and be consistent with, the storefront framing; and
(ii) Glazing in display windows and transoms must be clear, except that:
(A) a reversible, gray-scale translucent treatment may be applied to the interior face of display window glazing, the lesser of forty-eight (48) inches above the sidewalk or half of the height of the display window, exclusive of transom windows; or to the interior face of a transom window where existing interior conditions preclude the installation of clear transom windows; or where a dropped ceiling or security roll-gate housing is installed in conformance with this subdivision; or
(B) In cases where "back-of-house programming" cannot be located anywhere other than adjacent to a storefront window, and where if left visible to the public it would detract from the commercial establishment, building or streetscape, or could otherwise cause a security issue, staff may approve the application of a reversible grey-scale translucent film to fully or partially block one (1) or (2) display windows, subject to the following requirements: Staff may approve the application of grey scale to one (1) display window if the establishment has only two (2) display windows, and no more than two (2) display windows if the establishment has three (3) or more display windows. No grey scale may be approved if the establishment has only one (1) display window. In approving the installation of grey scale, the staff will consider the overall reduction of transparency of the storefront. The construction of any temporary partitions behind the approved greyscale film must be removed when the film is no longer needed for the commercial establishment that installed it. This subdivision shall also apply to individual landmarks.
(4) Framing. Storefront framing must feature profiled trim that recalls the articulation of historic storefront framing, and may be a traditional or contemporary type.
(5) Orientation. New infill must be installed parallel to the building's sidewalk and/or consistent with the plane of the facade and the location of the historic infill, and must be set back from the face of the existing storefront surround the minimum dimension required to avoid concealing any significant architectural feature, including features previously concealed by existing storefront infill, but in no event less than four (4) inches from the face of the storefront surround, unless conditions indicate otherwise.
(6) Bulkhead. The bulkhead must be between eighteen (18) and thirty (30) inches in height, including a stone or masonry curb, unless the historic storefront prototype indicates a lower or higher bulkhead, in which case the bulkhead may match the height of the historic prototype, and must feature details or materials that recall the articulation of historic storefronts except:
(i) Where the infill is based on a traditional example or model with paneled bulkheads, the bulkhead must feature panels and stiles, rails, and moldings that match historic prototypes; or
(ii) Where a limited amount of existing non-original infill is being modified, the new bulkhead may match the existing.
(7) Entrance and Doors.
(i) Recessed entrances may have either splayed or straight returns.
(ii) The width of the entrance will match the proportions of entryways to display windows found in historic storefronts, and will also meet minimum requirements for accessibility.
(iii) The design of the new door will maintain the design intent of new entrance infill required by this section, or will be a re-creation or restoration of the original or historic door pursuant to the requirements 63 RCNY § 2-11(f). New infill in service entrances, such as those that historically provided egress or access to freight elevators or had other utilitarian uses and were not historically used for storefronts or residential entrances, may vary in design, configuration and material in keeping with similar service entrances found in the particular historic district where the installation occurs. Alternatively, provided there is no significant historic fabric, a service entrance that was not a garage opening or loading bay for vehicles, may be removed and replaced with a storefront entrance, display window or other storefront infill pursuant to this section.
(8) Material. If the building was constructed prior to 1900, the material of the new infill must either match the historic material, if known, or be wood; for buildings constructed in or after 1900, or built before and altered in or after 1900 to include storefronts, the material of the new infill may be wood or metal or match the historic material.
(9) Finish. New storefront infill must have a finish that recalls the finish of historic storefronts.
(10) Interior Partitions and/or Built-In Features. Interior partitions, built-in features and vitrines built parallel to a display window must be a minimum of eighteen (18) inches behind the glass of the display window and:
(i) Have a surface area that blocks no more than fifty (50) percent of the area of the display window (exclusive of the transom), not including dropped soffits;
(ii) Have an interior quality finish and/or materials on the street facing side and feature non-illuminated, or indirectly illuminated display(s) of graphics or merchandise;
(iii) Are limited to a first floor storefront, except a partition or built-in feature may also be allowed at second story storefronts of commercial buildings;
(iv) Where such partition or built-in feature is a free-standing partition or vitrine within the display window below the transom, the horizontal dimension shall not block more than seventy-five (75) percent of the width of the display window; and
(v) Dropped soffits at the ceiling may be no closer than twelve (12) inches to the glass of the display or transom window and may be dropped the minimum distance necessary to address the structural or other issues requiring such dropped soffit.
(vi) This subdivision shall also apply to individual landmarks.
(11) Piers. If original or historic piers have been previously removed, the design must include the restoration of the piers or the introduction of features that recall the location, size, and dimension of such piers.
(12) Removal of modern cladding. If an applicant is proposing to remove modern cladding on the storefront or the area surrounding the storefront, the applicant must first perform probes of the material to see if historic material or elements exist behind the modern cladding.
(i) If significant historic storefront material or elements exists underneath the cladding, the historic material must be restored and the new storefront can only be approved pursuant to 63 RCNY § 2-11(f).
(ii) If a significant portion of the historic storefront surround exists underneath the cladding, but no historic storefront infill remains, the storefront surround must be restored, pursuant to 63 RCNY § 2-11(f), as part of the application for new storefront infill under this paragraph.
(13) Restoration of the original storefront opening. If the original storefront opening has been reduced or increased in size the design must include the restoration of the height and width of the original opening, except that:
(i) The existing storefront opening may be maintained where the size and organization of storefront bays and entrances were altered in a way that is consistent with other buildings within the historic district that include storefronts, or
(ii) Where interior conditions preclude restoration to the original height (e.g., later structural elements or existing interior roll-gate housing or mechanical systems) the existing storefront opening shall be enlarged or reduced to the greatest extent feasible, and:
(A) The design of the surround is consistent with the materials and details of the historic base of the building; and
(B) If necessary, given the size of the display windows, the design features an opaque glazed transom window.
(14) New door and door opening. A new door opening and door may be constructed to provide access to an existing storefront where:
(i) The new door is on the same facade and in close proximity to an existing storefront display window;
(ii) The new door opening will be installed in non-historic storefront infill or through plain brick;
(iii) The width of the new door opening is the minimum necessary to provide for a door that meets accessibility requirements and, if needed, sidelight, and the height of the door opening is aligned with the height or the storefront or other storefront feature and does not call undue attention to itself; and
(iv) The design of the new door is consistent with existing storefront doors or is consistent with the criteria for a replacement door.
(15) Security gates. LPC Staff may approve an application for roll-down security gates and grilles on proposed storefronts where:
(i) The security gate is located behind the storefront infill and the gate is open mesh where it covers glazed areas; or
(ii) If the roll-down security gate is mounted so that the gate rolls down on the exterior side of the display window and door:
(A) The installation does not affect, obscure or damage historic fabric;
(B) The housing for the roll-down security gates is installed so as not to protrude, or protrudes the least amount feasible, beyond the face of the storefront display window or transom, and it is finished to match the storefront framing;
(C) The security gate tracks are recessed or set into reveals along the sides of the storefront; and
(D) The security gate is open mesh where it covers glazed areas of the storefront.
(d) Awnings and Canopies at Commercial Storefronts and at Residential and Other Buildings.
(1) Recladding and retention of existing awnings and sidewalk canopies.
(i) LPC Staff will issue a Certificate of No Effect or a Permit for Minor Work for recladding existing awnings and sidewalk canopies if the proposed recladding meets both of the following criteria:
(A) The awning or canopy was present at the time of designation or was previously approved by an LPC permit; and
(B) The existing frame will be reclad in a material and finish that conforms to the criteria set forth in subdivision (d)(2)(vii)-(ix) or (d)(3)(ix)-(xi) of this section.
(ii) If a new storefront is being installed, an existing storefront awning or canopy in noncompliance with the criteria set forth in paragraph(3) below cannot be retained unless the applicant can demonstrate to LPC Staff that the new storefront installation will not require even the temporary removal of the existing awning or canopy.
(2) Installation of new awnings on windows, doors and porches that are not associated with storefronts. LPC Staff will issue a Certificate of No Effect or a Permit for Minor Work for new awnings on residential windows, doors and porches if the proposed awning meets all of the following criteria applicable for such installation:
(i) Awnings installed on residential windows, doors and porches will be either retractable or fixed.
(ii) Awnings will be installed at or below the lintel, or within the window opening, as close to the top of the window as feasible, and will conform to the size and shape of the window or door opening.
(iii) The attachment of the awning will not cause the loss of, damage to, or hide or obscure any significant feature.
(iv) Awnings will project at an angle and be of a length, size and slope which are proportional to the size and height of the window or door.
(v) Awnings at occupiable terraces and architectural setbacks above the ground floor may extend over more than one opening, so long as the overall length of the awning is proportional to the size and length of the terrace or setback and the depth does not exceed the depth of the terrace or setback.
(vi) Awnings on porches will conform to the bay structure and proportions of the porch.
(vii) All awnings on a building or portions of a mixed use building that are not associated with storefronts must match in terms of fabric color and pattern if installed on primary or visible secondary facades.
(viii) Awnings will be clad only with water repellant canvas with a matte finish or other fabric of a similar appearance.
(ix) Awning fabric will consist of a solid color or vertical stripes that harmonize with the historic color palette of the building. No lettering or signage is permitted on awnings that are not associated with storefronts except for an address number on an awning over an entrance, and the numbers of such address must be no greater than six inches in height.
(3) Installation of new awnings on storefronts, display windows and doorways. LPC Staff will issue a Certificate of No Effect or a Permit for Minor Work for new awnings on ground story storefronts, ground or second story display windows, and doorways if the proposed work meets all of the following criteria applicable for such installation:
(i) The awning must be retractable on buildings which were designed with integral retractable awning housings as part of the storefronts. In all other cases, the awning may be either retractable or fixed. If fixed, the awning must have a straight slope and be open at the sides. If retractable, the awning must have a straight or curved slope and may or may not have side panels. Retractable awnings may follow the curved configuration of the window or door opening over which they are installed. If a display window or doorway opening has an arched or segmental head, the awning must be retractable if it is installed at the head of the window, but may be fixed if it is installed at the rectilinear transom bar. Both retractable and fixed awnings may or may not have a skirt. Awning skirts must be unframed. The skirt height must be proportional to the height and size of the awning, but cannot be greater than twelve (12) inches.
(ii) The attachment of the awning will not cause the loss of, damage to, or hide or obscure any significant feature.
(iii) The awning will be installed within the storefront opening, surround or enframement, or, if that is not possible, at or directly below or above the lintel or transom bar, except that the awning may be attached above the lintel where:
(A) a roll-down security gate that either was present at the time of designation or was previously approved by the Commission makes it impossible to install the awning at the lintel or transom bar; or
(B) installing the awning at the lintel or transom bar will result in the lowest framed portion of the awning being less than eight feet above the sidewalk, and
(C) where the awning is installed above the lintel, the awning encroachment above the lintel will be the minimum required to accommodate the conditions described above in clauses (A) and (B), and will not detract from the significant architectural features of the storefront, building or, where relevant, historic district.
(iv) In cases where the storefront itself projects from the facade, the awning will be attached to the projecting storefront below the storefront cornice or cap.
(v) The length of the awning will not exceed the length of the storefront opening or the associated window opening, and the edges of the awning shall be aligned as closely as possible with the inside face of the principal piers of the storefront, or the window or door opening.
(vi) The underside of the awning will be open.
(vii) The lowest framed portion of the awning will be at least eight (8) feet above the sidewalk. The lowest unframed portion will be at least seven (7) feet above the sidewalk or otherwise meet applicable Department of Buildings and/or Department of Transportation criteria.
(viii) The awning will project at an angle and be of a length, size and slope which are proportional to the size and height of the storefront, window or door, as relevant.
(xi) The awning will be clad only with canvas with a matte finish or other fabric of a similar appearance.
(x) Signs, such as lettering or graphics, are permitted to be painted on the awning skirt only; no lettering or graphics will be permitted on the sloped portion of the awning. The size of lettering will be proportional to the height of the awning skirt.
(xi) Awning fabric will consist of a solid color or vertical stripes that harmonize with the historic color palette of the building, but are not required to match other awnings on buildings with multiple storefronts.
(xii) Awnings installed pursuant to approvals issued in connection with a Modification of Use or Bulk shall continue to comply with such approvals. Unless otherwise provided for in this section, awnings installed on Individual Landmarks and on storefront restorations approved by a restorative approval pursuant to 63 RCNY § 2-11(f) may be retractable or fixed, and if fixed:
(A) Have a "lean-to" frame with no connecting part between the top bar and the side bar installed perpendicular to the facade;
(B) The side bar perpendicular to the facade is round in shape;
(C) The frame is finished with a clear-coat, or grey finish; and
(D) Feature an unframed skirt.
(4) New sidewalk canopies on certain types of buildings. Installation of new sidewalk canopies on residential, hotel and former residential buildings or buildings historically constructed with an accessory residential component, including private clubs. LPC Staff will approve the installation of a sidewalk canopy where:
(i) There is historic precedent for the installation of a canopy between the building entrance and the sidewalk on this building, this type of building or, if the building is located within a historic district, in the historic district; and
(ii) The construction, installation, attachment, and height of the canopy will conform to the requirements of the Zoning Resolution and Department of Buildings and/or Department of Transportation requirements, but in no event can the bottom of the canopy be less than eight (8) feet above the sidewalk; and
(iii) The size and basic design of the canopy will be consistent with canopies historically found at buildings of this type; and
(iv) The canopy will be clad in canvas with a matte finish or other fabric of a similar appearance, in a color and pattern that matches or recalls historic designs and does not distract from the building's historic color palette. The front and side of the canopy may have the building or institutional name and address number in numbers or letters no taller than twelve (12) inches, and a logo of not more than 4 square feet on the street-facing end of the canopy, but shall not have any other signage, numbering or lettering;
(v) The underside of the canopy will be open, and the framing members may be exposed or enclosed in canvas that closely follows the profile of the shape of the canopy or canopy roof;
(vi) Small, simply designed fixtures may be attached to the framing underneath the canopy, including down-light type fixtures to illuminate the sidewalk and building entrance/walkway, heat lamps and cameras, provided such installations are not visible except from underneath the canopy;
(vii) The installation of the canopy will not damage or cause the removal of, any significant architectural feature;
(viii) The canopy frame will be attached to the facade and sidewalk with the minimal number of fasteners practical, installed in mortar joints or flat, unrelieved portions of ornamental materials, and in non-historic paving where feasible;
(ix) The canopy has round metal poles with a painted or natural finish, in keeping with style and age of the building;
(x) The canopy has a bowed profile, or to the extent precedents exist for such a design, relates to the shape of the opening; and
(xi) The canopy is installed within the architectural features enframing the opening, such as piers, cornices, lintels, and surrounds, except that where installing the canopy within the opening enframement will result in the lowest portion of the canopy being less than eight (8) feet above the sidewalk, or the operation of the door impeded, a canopy may be approved if:
(A) Sufficient space exists between the high-point of the canopy and the underside of any projecting cornice or other ornament surround enframing the entrance doors to visually separate the two elements; and
(B) At its widest points, it will overlap, extend past, or obscure ornamental elements enframing the entrance the least feasible amount.
(Amended City Record 12/20/2018, eff. 1/19/2019; amended City Record 7/20/2023, eff. 8/19/2023)
§ 2-13. Signage
(a) Introduction. Signage was a typical feature of historic buildings that contained commercial or manufacturing uses. Such signage included signs painted or affixed above storefronts in signbands, signs within display windows, banners, bracket signs, and signs hanging from underneath canopies. This rule sets forth the requirements for LPC Staff approval of some types of storefront signage and associated lighting for such signage. All proposals for signage not seeking a discretionary approval from another City agency must comply with the Zoning Resolution in terms of size, placement, projection and illumination.
(b) Definitions. As used in this section, the following words have the following meanings:
Armature. "Armature" means a metal structural support for a projecting sign.
Banner. "Banner" means an outdoor sign made of a non-rigid material with no enclosing framework, aside from an armature, installed perpendicular to a building facade and featuring graphics or lettering that are painted, screen-printed, or digitally printed, which announce an establishment in a building. A banner may also include a weight or building tie-back.
Bracket Sign. "Bracket Sign" means an outdoor sign, with two display faces, installed perpendicular to a building facade and attached to an armature, used as an announcement for an establishment in the building, consisting of the rigid display faces and all letters, words, numerals, illustrations, decorations, trademarks, emblems, symbols or their figures or characters associated with the name of the establishment that are applied to the faces. In addition, a bracket sign may consist solely of an outline of a shape and/or letters intended to act as a symbol or sign for the establishment.
Canopy means a metal frame clad with fabric that extends from a building entrance over the sidewalk to the curb, where it is supported on vertical posts.
CNE. "CNE" means Certificate of No Effect as defined by § 25-306 of the New York City Administrative Code.
Establishment. "Establishment" means a manufacturing, commercial or retail business or profession.
Facade. "Facade" means an entire exterior face of a building.
Flag. "Flag" means fabric containing graphics, an emblem, or message designed to be flown from a wood or metal structural support mounted perpendicular to a building facade. A flag is a sign for purposes of this section if it is used to announce an establishment in the building. No flag as defined herein shall be used for third-party advertising or accessory business advertising.
LPC. "LPC" means the Landmarks Preservation Commission.
LPC or Commission Staff. "LPC staff" or "Commission staff" means the staff of the Landmarks Preservation Commission acting in the Commission's agency capacity.
PMW means a Permit for Minor Work pursuant to § 25-310 of the New York City Administrative Code.
Pier means an exterior vertical member(s) or element(s) (usually of brick, stone, or metal), placed at intervals along a wall, which typically separates storefront openings within a single building or defines a single storefront opening.
Sign means a fixture or area containing lettering or graphics used to advertise a store, goods, or services.
Signage means any lettering or other graphics used to advertise a store, goods, or services.
Signband means the flat, horizontal area on the facade, usually located immediately above the storefront and below the second story window sill where signs were historically attached. Signbands can also be found immediately above the storefront display window, but below the masonry opening's lintel. A signband shall not include the frieze of a cornice that is less than 12" in height. A signband may exist above a second story storefront.
Significant architectural feature means an exterior architectural component of a building that contributes to or reinforces its special historic, cultural, and aesthetic character.
Storefront means the first or second story area of the facade that provides access or natural illumination into a space used for retail or other commercial purposes.
Storefront infill means the framing, glazing, and cladding contained within a storefront opening in the facade, including display windows, bulkheads, entranceways, etc.
Storefront opening means the area of the facade between the piers and lintel, which contains storefront infill.
Transom means a glazed area above a display window or door that is separated from the display window or door by a horizontal framing member ("the transom bar"). The glazing in the transom may be fixed or operable.
(c) Permit Not Required. No permit is required for the following types of signage installations:
(1) Once a staff-level permit has been issued for a banner, a new banner of a different design may replace the approved or current banner provided that the original armature is maintained, and all requirements of this section continue to be met.
(2) Where an armature existed at a location at the time of designation and documentation shows it was used for a banner or flag, the current banner or flag may be exchanged for a new banner or flag of a different design provided that the original armature is maintained, and the new banner or flag is equal to or smaller than the current banner and meets the relevant criteria in subparagraphs (5) through (8) of paragraph (e) of this subdivision.
(3) Where an armature and banner or flag was previously approved by the Commission, the current banner or flag may be exchanged for a new banner or flag of a different design provided that the dimensions are equal to or smaller than the Commission-approved installation, and the materials and finish of the new banner or flag are consistent with the Commission approval. No neon or other vividly bright colors will be permitted.
(4) Once a staff-level permit has been issued for painted and vinyl signage applied directly onto the storefront glazing, the applied signage may be exchanged for new applied signage of a different design provided that all Rule criteria continue to be met.
(5) "For lease" or "for sale" signs and concealment of interior construction. Temporary painted and vinyl signage, or posters, advertising that a space is for sale or lease, or for the purpose of concealing on-going interior construction work, may be installed at storefront and transom glazing without a LPC permit, and may exceed the glazing coverage requirements for such signage, but must be removed once the space is sold or leased or the interior construction is completed.
(d) Installation of Storefront Signs. The LPC Staff will issue a CNE or PMW for a storefront sign, other than a bracket sign, if the proposed work meets the relevant criteria listed below:
(1) The signage is as-of-right pursuant to the Zoning Resolution and the Building Code.
(2) The installation of signage will not damage, destroy or obscure significant architectural features or material of the building or storefront.
(3) Signs will be installed in the signband above a storefront opening or within the storefront opening.
(4) Signs will include dimensional letters and logos composed of wood or metal, or painted plastic, that project no more than two inches if installed directly into masonry or wood signbands, or directly on wood, metal, or opaque glass sign panels mounted flat with the signband, or painted directly onto the ground floor signband and lintels. Pin mounted letters requiring numerous attachments points to historic masonry signbands should utilize mounting strips where feasible, and will not be allowed in any instance on cast iron.
(5) Flat sign panels will project no more than 2 inches from the facade, and dimensional letters on sign panels will project no more than 2 inches beyond the panel for a total projection of four (4) inches from the facade. In the case of dimensional letters installed on a metal channel within a transom, the channel may be straight or slightly bowed, and the letters will not project beyond the plane of the facade, and will be no larger than 18 inches and in no event higher than the height of the transom glass, and the channel will be no more than 1 inch tall. LPC Staff will not approve both a sign in the signband and a sign on a metal channel within a transom.
(6) The sign will be proportional to the signband, but in no event will it exceed 90 percent of the area of the signband and the letters will not be higher than eighteen (18) inches in total whether one or two lines of text is used.
(7) Signage mounted on the exterior will not be internally illuminated, except that it may be "halo" lit with a light source behind opaque letters.
(8) One interior neon sign, or other similar non-flashing illuminated sign that utilizes tubing and is imitative of a traditional neon sign, per display window is permissible, provided that the sign is transparent, is installed a minimum of six (6) inches behind the glass, does not substantially reduce the transparency of the display window and does not exceed fifteen (15) percent of the area of the display window or transom. Non-concealed illuminated lighting strips outlining the display window will not be permitted. Any other illuminated signage, including LED screens, must be at least eighteen (18) inches set back from the inside plane of the glass of the display window or transom and must otherwise meet the requirements in paragraph (10) of subdivision (c) of 63 RCNY § 2-12.
(9) Painted and vinyl signage may be applied directly onto the storefront glazing, including glazing at the doors, transom and display window. Non-illuminated dimensional letters and logos composed of wood, metal, or painted plastic that project no more than 1/4 inch may be applied directly to the interior or exterior of transom glazing. Signage cannot exceed more than twenty (20) percent of the glazed area per door, transom or display window, and cannot be applied to windows with distinctive glazing as defined in 63 RCNY § 2-14(b), "Special Windows and Doors". For purposes of this paragraph, the percent of the glazed area covered by signage will be calculated by the total area of the sign as a visual object and the collective groupings of text and images, without subtracting for voids between letters, numbers or graphics.
(10) Signage installed on the exterior may be illuminated externally with a shielded source of light, including "halo" lit with a light source behind opaque letters, or with a small projecting fixture twelve (12) inches or less in length or width placed above the sign, with a maximum number of fixtures as follows: one fixture for the first one to six (1 - 6) feet of storefront opening; two fixtures if the storefront opening is between six to twelve (6 - 12) feet; three fixtures if the storefront opening is between twelve to eighteen (12 - 18) feet; and four fixtures if the storefront opening is between eighteen to twenty-four (18 - 24) feet. In no event will the light fixture arm project more than eighteen (18) inches from the sign. Cove fixtures must have the same finish as the sign, and if the sign projects from the facade, the cove fixture must be an integral part of the sign.
(11) Light fixtures will be installed in areas of plain masonry, metal, or wood, provided that the installation does not damage, destroy, or obscure significant architectural features of the building or storefront.
(12) Lighting conduits will be concealed.
(13) Exterior light fixtures, limited in number as set forth in paragraph (10), may only illuminate signage at signbands or sign panels, or may illuminate storefronts and/or awnings where no signbands or sign panels are being utilized.
(14) In approving an application for signage the LPC Staff will consider the overall amount of approved and grandfathered signage for the storefront and building. If the LPC Staff determines that the overall amount of signage for the storefront or building is excessive and will detract from the architectural features of the building, the adjacent buildings, or the streetscape, the staff will require that existing or proposed staff approved signage be eliminated or reduced. Such signage includes but is not limited to plaques, signs on awning skirts, signage in a signband, signage applied to the storefront glazing, flags and banner or bracket signs. LPC Staff will not approve new signage that will result in a storefront having more than three (3) types of signage.
(e) Installation of Banner and Bracket Signs. The LPC Staff will issue a CNE for a banner or bracket sign if the proposed work meets all of the following criteria:
(1) The armature will be installed below the second story, or above the second story at the lowest point to meet the minimum height criteria of the Zoning Resolution, within the storefront opening or on the flat face of a plain masonry, wood or metal pier, but not including cast iron, and will be mechanically fastened into the storefront infill or into the mortar joints of a plain masonry pier, or attached to the framing members at the underside of a metal canopy on an industrial building, and such installation will neither damage nor conceal any significant architectural features of the building.
(2) Bracket signs may be supported by means of one or two projecting armatures or may be flush mounted with a sleeve and/or concealed attachment. Banner signs must be supported by means of a single projecting armature at the top of the banner but may also utilize a tie-back from the bottom of the banner to the building facade.
(3) The armature will be a metal finished to be harmonious with the storefront finish, will be proportional to the banner or bracket sign and will be simply designed so as not to call undue attention to itself.
(4) The display faces of the bracket sign may be made of wood or metal. If the bracket sign has display faces, the letters, words, numerals, illustrations or graphics may be painted or applied onto the display faces, and may be raised slightly from the surface. Any raised features, including letters, words, numerals, illustrations or graphics, must be made of wood or metal, or painted plastic. The overall width, as measured from face to face, will not exceed two (2) inches, and, if there are raised features the bracket sign shall not exceed a width of three inches as measured from the outside plane of such raised features.
(5) The banner sign may be made of canvas with a matte finish or other fabric of a similar appearance. Letters, words, numerals, illustrations or graphics may be painted or applied onto one or both sides of the fabric.
(6) The display faces, fabric, and the letters, words, numerals, illustration or graphics of a banner or bracket sign will be of a color or colors that do not detract from the significant architectural features of the building or neighboring buildings. No neon or other vividly bright colors will be permitted.
(7) The bracket sign will not be internally illuminated, but the display faces of a bracket sign or banner may be externally illuminated by a lighting fixture that is integral or attached to the sign or armature, is, if not concealed, as small and discrete as possible and does not call attention to itself, and is finished to blend with the sign or armature.
(8) The bracket sign may be fixed or may move freely from its points of attachment to the armature. A banner sign must move freely from its points of attachment to the armature, and may be tied back to the building facade. In no event will the banner or bracket sign be made to move by mechanized or controlled means.
(9) Number of banner or bracket signs for ground floor establishments.
(i) Except for signs subject to subparagraphs (ii), (iii) and (iv) below, one banner or bracket sign per ground floor establishment will be permitted.
(ii) In buildings with more than one ground floor establishment, one banner or bracket sign per establishment may be installed, provided that there are no more than two signs per twenty (20) feet of building facade fronting on a street. The placement of the banner or bracket sign on the building will be in close proximity to the establishment that is identified on the banner or bracket sign.
(iii) In buildings with more than one ground floor establishment which were historically designed with uniform storefronts and/or signage, and where there is not already an approved signage master plan, the design, placement, materials, and details of all of the bracket or banner signs and armatures must be of a consistent design that, where applicable, recalls the historic signs.
(iv) A ground floor establishment with a corner storefront may have one banner or bracket sign on each building facade with at least twenty (20) feet of street frontage, provided that each facade has a primary entrance and each banner or bracket sign is located in close proximity to an entrance, but in no event will more than one banner or bracket sign be located within twenty (20) feet of the corner of the building.
(10) Banner and bracket signs for upper story establishments. A single armature for a banner or bracket sign for an upper story establishment or establishments may be installed adjacent to the building entrance for such upper story establishments. This armature may hold one sign for each upper story establishment, provided such banner or bracket signs hang vertically underneath one another on the same armature, and further provided that in no event will the total dimensions of such banner or bracket signs, taken together, exceed the size requirements specified in paragraph (11) below.
(11) The size of the banner or bracket sign, oriented horizontally or vertically, will conform to the requirements of the Zoning Resolution, but in no event will the size exceed twenty-four (24) inches by thirty-six (36) inches in districts that were historically manufacturing or industrial in character, eighteen (18) inches by twenty-four (24) inches in districts that were historically commercial, or twelve (12) inches by eighteen (18) inches in districts that were historically residential in character. Novelty shapes, such as circles, polygons and irregular shapes are permitted, as are novelty objects, provided such shapes and objects generally fall within the parameters described in this paragraph.
(12) The projection of the banner or bracket sign and armature beyond the property line will conform to the requirements of the Zoning Resolution and Building Code, but in no event shall extend more than 40 inches from the facade in districts that were historically manufacturing or industrial in character, eighteen (18) inches in districts that were historically commercial, and no more than twelve (12) inches in districts that were historically residential in character.
(13) The banner or bracket sign will be installed so that the lowest portion of the sign is at least ten (10) feet above the sidewalk.
(14) In approving an application for a banner or bracket sign, LPC Staff will consider the overall amount of approved and grandfathered signage for the storefront and building. If the Staff determines that the overall amount of signage for the storefront or building is excessive and will detract from the architectural features of the building, adjacent buildings or streetscape the Staff will require that other types of existing or proposed staff approved or approvable signage, including but not limited to plaques, signs on awning skirts and signage applied to the storefront glazing, be eliminated or reduced.
(f) Signage for Commercial Spaces Below the Sidewalk. Where a commercial establishment has an entrance below the sidewalk level, LPC staff will issue an approval for a sign that is installed:
(1) On a plain masonry band above the storefront opening, if one exists, and provided the signage otherwise meets the criteria set forth in subdivision (c); or
(2) On a flat metal or wood panel attached to an existing areaway fence, and provided:
(i) The attachment does not damage original or historic fabric or call attention to itself or detract from significant features of the fence;
(ii) The sign panel is not more than 1 inch thick and the signage is painted or applied to the panel; and
(iii) The panel is not bigger than twelve (12) inches by thirty-six (36) inches.
(g) Painted Wall Signs. Signs painted directly on a building facade are a traditional method of advertising that was historically found in commercial and manufacturing areas, typically on plain secondary facades with exposed common brick. Sometimes they advertised a business located within the building, while other times they advertised unrelated products or services. They typically had borders and were primarily text, although illustrations were also common.
(1) Staff approval for painted wall signs on buildings in a historic district. With the exception of Individual Landmarks, staff may approve an application for a sign painted directly on the facade material of a building in a historic district if it meets all of the following criteria:
(i) There is substantial historic precedent for painted wall signs in the historic district or on the individual building;
(ii) There is no other painted wall sign on the building, but not including a painted sign in a signband above a storefront opening;
(iii) There is no other painted wall sign on another building within 100 feet of the proposed location;
(iv) The sign will be located at or above the second floor on a secondary facade that is (A) plain brick or stucco, (B) will not cover or include any window openings, but may cover or include bricked-in window openings; and (C) will not detract from any significant architectural feature of the building or adjacent building;
(v) The sign, including the border referenced below, will occupy no more than twenty percent (20%) of the visible wall area and shall be rectilinear in shape. For purposes of this subsection, the term "visible wall area" shall mean the area of the secondary facade where it is most visible from the street within two blocks of the secondary facade. The visible wall area shall include coplanar wall surfaces that are visually contiguous at the secondary facade, including parapets, bulkheads and additions on the building;
(vi) The sign will have a black or white solid painted border, at least two (2) inches wide, around the sign, which contrasts with the background color of the sign;
(vii) The sign will be set back from the primary facade a minimum of three (3) feet and will be at least two (2) feet from significant architectural features, including but not limited to cornices, special windows, window openings, lintels and sills; and
(viii) The vendor tag will be located within the sign or immediately below the sign, justified to the side or corner closest to the street, and shall be no larger than twenty-four (24) inches by thirty-six (36) inches.
(2) The approval of an application that meets the requirements of subdivision (1) above shall be in the form of a master plan valid for a period of ten (10) years, unless the applicant requests that it be for a lesser term. The applicant or owner must obtain an approval for each sign painted on the building. After the ten-year term has expired, the property owner must reapply for a new master plan.
(h) Miscellaneous Commercial Signage.
(1) Plaques. LPC Staff will issue a CNE or PMW for plaque signage identifying professional services, such as doctors' offices or building management companies, or for other retail and commercial establishments, in connection with a storefront or other primary entrance, or on a primarily non-commercial building that does not contain a storefront, such as a row house or small apartment building, if the the proposed work meets the following criteria:
(i) Is as-of-right under the Zoning Resolution and Building Code;
(ii) The plaque is installed into areas of plain, unornamented masonry or non-historic storefront infill or otherwise will not conceal or damage significant architectural features;
(iii) The plaque is not more than one and a half inches thick, inclusive of any projecting lettering and/or logos;
(iv) The plaque and letters are made of a traditional material such as metal, glass, wood, or stone and has a finished quality; and
(v) The plaque is not larger than two (2) square feet (288 square inches) at small residential or commercial buildings six (6) stories or less in height and with a street frontage of forty (40) feet or less, and not larger than three (3) square feet (432 square inches) at any other building, in a square or rectangular configuration and the LPC Staff determines that due to quantity, size and proportion the plaque(s) do not call undue attention to itself or themselves or detract from the significant architectural features or historic character of the building or district; and
(vi) If attached to a free-standing pole installed in an areaway of a free-standing house, row house or small residential or commercial building:
(A) The pole has a dark finish and is not taller than six (6) feet;
(B) The pole is installed through non-historic paving, away from the facade and does not obscure or hid decorative features of the building or detract from adjacent buildings;
(C) There are no more than three plaques on the pole;
(D) Each plaque is not larger than six (6) inches by eighteen (18) inches.
(2) Poster Boxes on Certain Types of Buildings. With respect to poster boxes on the facades of buildings used as theaters, religious institutions, community centers, libraries, museums, and clubs, or other buildings that traditionally used poster boxes, LPC staff will issue an approval if the poster box:
(i) Is installed into areas of plain, unornamented masonry or otherwise will not conceal or damage significant architectural features;
(ii) Consists of a metal or wood frame with clear glass;
(iii) Any lighting is restricted to the inside of the box with concealed wiring; and
(iv) The LPC staff determines the size of the box does not call undue attention to itself or detract from significant architectural features.
(3) Menu Boxes. With respect to menu boxes on storefronts used as restaurants, LPC staff will issue an approval if there is no more than one menu box per entrance per street and such menu box:
(i) Is installed at or near the entrance;
(ii) Is installed into areas of plain, unornamented masonry, or into non-historic storefront material, or otherwise will not conceal or damage significant architectural features, or is attached to an areaway fence in such a way that does not damage original or historic fabric or call attention to itself or detract from significant features of the fence;
(iii) Consists of a metal or wood frame with clear glass;
(iv) Is not larger than twenty-eight (28) inches by thirty (30) inches and LPC Staff determines that because of its size it does not call undue attention to itself or detract from significant architectural features; and
(v) Any lighting is restricted to the inside of the box with concealed wiring.
(Amended City Record 12/20/2018, eff. 1/19/2019; amended City Record 7/20/2023, eff. 8/19/2023)
§ 2-14. Windows and Doors
(a) Introduction. These rules apply to proposals for work involving the installation of windows and doors at buildings that are Individual Landmarks or are within a historic district or scenic landmark in existing window and door openings. The rules are categorized according to types of facades (e.g., primary facades; visible secondary facades; and minimally visible and non-visible facades) and building types (e.g., small residential and commercial buildings; large residential and commercial buildings). In addition, these rules govern the creation of modified window openings and new window and door openings, and the installation of windows and doors in such openings. Finally, the rules cover window and door "add-ons", such as storm windows and doors, screens and applied films.
(b) Definitions. As used in this section, the following terms have the following meanings:
Color. "Color" means the sensible perception of hue, value and saturation characteristics of surfaces of window and door components. In the event of disagreement, the Munsell system of color identification will govern.
Commission. "Commission" means the Landmarks Preservation Commission as established by Section 3020 of the Charter.
Commissioners. "Commissioners" means the eleven Commissioners of the Landmarks Preservation Commission, including the Chair, as established by Section 3020 of the Charter.
Configuration. "Configuration" means the number, shape, organization and relationship of panes (lights) of glass, sash, frame, muntins, or tracery.
Details. "Details" means the dimensions and contours of both the stationary and moveable portions of a window or door, and moldings.
Dutchman. "Dutchman" means a repair technique for replacing small sections of a damaged material with new material that matches the original material.
Entrance infill. "Entrance infill" means the assembly of door(s), transom(s), sidelight(s), spandrel(s) and other framing elements, as opposed to a singular door, within an entrance opening.
Existing window or existing door. "Existing window" or "existing door" means the window and/or door existing at the time of designation or a window and/or door which has been changed subsequent to designation pursuant to a permit issued by the Commission.
Fenestration. "Fenestration" means the arrangement, proportioning and design of windows in a building.
Finish. "Finish" means the visual characteristics, including color, texture and reflectivity of exterior material. Finish can be based on the original or historic finish, or finishes used at similar buildings in later eras of significance typical of a particular historic district as an alternative to matching the original or historic finish.
Frame. "Frame" means the stationary portion of a window or door unit that is affixed to the facade and holds the sash or other operable portions of the window or door.
Glazing. "Glazing" means the material, usually glass, that fills spaces between sash members (rails, stiles and muntins), commonly referred to as panes or lights. Note: glazing may consist of multiple layers of glass, including laminated glass and insulated glass with or without low-e coatings, provided the glass is otherwise clear.
Head. "Head" means the upper horizontal part of a window or door frame or opening.
Historic window or historic door. "Historic window" or "historic door" means:
(1) a window or door installed at time of construction of the building; or
(2) a window or door of a type installed at time of construction of similar buildings in similar periods and styles; or
(3) a window or door installed at time of major facade alterations 30 or more years ago.
Jamb. "Jamb" means the side parts of a window or door frame or opening, as distinct from head and sill.
Landmarks law. "Landmarks Law" means Title 25, Chapter 3 of the Administrative Code of the City of New York.
Light. "Light" means a pane of glass, a window, or a sub-pane of a window or door.
Low-e. "Low-e" means a coating or sheet of material applied to glass that reduces the amount of heat transferred through the glass, which is considered clear or untinted for the purposes of these rules.
LPC. "LPC" means the Commission acting in its agency capacity to implement the landmarks law.
LPC Staff. "LPC Staff" means the staff of the Landmarks Preservation Commission acting in the Commission's agency capacity.
Match. "Match" means either an exact or an approximate replication. If not an exact replication, the approximate replication must be designed so as to achieve a suitable, harmonious and balanced result.
Meeting rail. "Meeting rail" means a sash rail in a double-hung window designed to interlock with an adjacent sash rail.
Member. "Member" means a component part of a window or door.
Molding. "Molding" means a piece of trim that introduces varieties of outline or curved contours in edges or surfaces as on window or door jambs and heads. Moldings are generally divided into 3 categories: rectilinear, curved and composite-curved.
Mullion. "Mullion" means a vertical primary framing member that separates paired or multiple windows within a single opening.
Muntin. "Muntin" means the tertiary framing member that subdivides the sash into individual panes, lights or panels; lead "cames" are often used in stained glass windows. Note: Muntins may be traditional true divided, or simulated divided light ("SDL") type; however, grids placed between two sheets of glass only are not considered muntins.
Operation. "Operation" means the manner in which a window or door unit opens, closes, locks, or functions (e.g., casement or double-hung). If non-operable, a window unit (such as a side light) is identified as "fixed."
Panning. "Panning" means an applied material, usually metal, that covers the front (exterior) surface of an existing window frame or mullion.
Permit. "Permit" means any permit, certificate or report issued by the Commission in accordance with the provisions of the Landmarks Law.
(1) "PMW" means Permit for Minor Work as defined by § 25-310 of the Landmarks Law.
(2) "CNE" means Certificate of No Effect as defined by § 25-306 of the Landmarks Law.
(3) "C of A" means Certificate of Appropriateness as defined by § 25-307 of the Landmarks Law.
(4) "Report" means the report referenced in § 25-318 of the Landmarks Law or a report issued in connection with a review of work pursuant to Section 856(h) of the Charter.
Primary facade. "Primary facade" means:
(1) a facade fronting a street or public thoroughfare that is not a street, such as a mews or court;
(2) A visible facade that possesses a level of design or significant architectural features that are commensurate with the building's street-fronting facade(s), and where such facade (i) faces but does not front a street, such as a setback facade, or (ii) is part of a dominant massing element where at least one facade is street-fronting or street-facing, such as a tower element; and
(3) A facade with a primary entrance to the building.
Rail. "Rail" means a horizontal sash member.
Repair. "Repair" means work to correct deterioration or decay of, or damage to, a window or door or any part thereof and to restore same, as closely as may be practicable, to its condition prior to the occurrence of such deterioration, decay or damage. The term "ordinary repair" refers to work that does not require a permit.
Restoration. "Restoration" means the process of returning, as nearly as possible, a building or any of its architectural features to its original form and condition.
Sash. "Sash" means the secondary part of a window which holds the glazing in place. It may be operable or fixed, and is usually constructed of horizontal and vertical members. A sash may be subdivided with muntins.
Secondary facade. "Secondary facade" means a facade that does not front on a street or a public thoroughfare and that does not possess significant architectural features that are commensurate with the street fronting facade.
Significant architectural feature. "Significant architectural feature" means an architectural component of a building that contributes to its special historic, cultural and aesthetic character, or that in the case of an historic district reinforces the special characteristics for which the district was designated.
Sill. "Sill" means the lower horizontal part of a window frame or window opening; also the accessory member which extends as a weather barrier from frame to outside face of wall.
Special window or special door. "Special window" or "special door" means a window or door that possesses rare or distinctive traits reflective of its style and age, including but not limited to:
(1) A rare shape and distinctive pattern, including but not limited to square sash with complex arched paneling; diamond, round and oval sash; sash with intersecting curved muntins; and multi-light sash or door leafs with densely-gridded window panes of thirty (30) square inches or less; and arch-headed doors. Unless otherwise classified as a special window or special door, the following window types are not considered special windows: square sash; square sash with simple arched paneling (e.g., half-round arch, elliptical arch, quarter-round arch, pointed arch); fixed or operable sash in simple arched transoms; sash with simply curved muntins; and multi-light sash or door leafs with large panes of more than thirty (30) square inches.
(2) Distinctive glazing, including but not limited to leaded; stained; etched; textured; and curved glazing. Unless otherwise classified as a special window or special door, clear or frosted glazing is not considered distinctive.
(3) Fine craftsmanship and/or distinctive materials, including bronze; brass; nickel silver; cast metal; and elaborate carved woodwork. Unless otherwise categorized as a special window or special door, the following are not considered fine craftsmanship or distinctive materials: copper or other sheet metal; kalamein; rolled steel; and extruded aluminum.
(4) Unique typology, including curved sash; bi-folding sash; operable true arch-headed double-hung or casement sash; and monumental window or door assemblies. Unless otherwise categorized as a special window or special door, the following are not considered unique: pivot sash, French doors, and casements.
(5) Age, including original windows at buildings constructed prior to 1850.
Stile. "Stile" means a vertical sash member.
Story. "Story" means a habitable floor level, including a basement but not including a cellar.
(c) Work for Which No Approval is Required.
(1) Maintenance, repair and retrofit of windows, doors and add-ons, except for special windows and special doors if removal to an off-site location is required to perform the work. Ordinary maintenance, minor repair and retrofits, including modifications to improve energy efficiency and weatherization, to windows, doors and add-ons (e.g., screens, storm windows, and films) at primary facades and secondary facades of Individual Landmarks and buildings in historic districts and scenic landmarks, including:
(i) In-kind replacement of clear glass, glazing putty and stops, and screens;
(ii) Prepping and repainting of windows, doors and add-ons to match the existing color and finish;
(iii) Replacing or installing perimeter caulking and sealants;
(iv) Repairing or replacing window or door hardware, such as hinges, knobs and handles, but excluding ornate historic exterior hardware on special doors;
(v) Replacing or installing weather-stripping;
(vi) Patching or straightening metal window and door components;
(vii) Patching or consolidating wood fibers or partially rebuilding wood window and door components with Dutchmen.
(2) Interior add-ons. New interior window and door add-ons at primary facades and visible portions of secondary facades, if the work meets all of the following criteria applicable to the work:
(i) The work is not occurring in an Interior Landmark;
(ii) The interior add-ons have no mullions, muntins or wide frames that are conspicuous as seen through the glazing of the primary window or door from the exterior of the building;
(iii) The interior add-ons have clear glass or clear acrylic (including plexiglass) or screens with a dark fabric; and/or
(iv) The add-on is an applied film and is clear.
(3) Interior and exterior add-ons at non-visible facades. New interior and exterior window and door add-ons at non-visible portions of secondary facades if the work is not occurring in an Interior Landmark and no significant exterior architectural feature of the window, door or building will be lost or damaged.
(d) Installation of Exterior Add-Ons for Windows and Doors in Individual Landmarks and Buildings in Historic Districts and Scenic Landmarks.
(1) Storm windows and doors and screens. LPC Staff may approve an application for new exterior window and door add-ons at primary facades and visible portions of secondary facades, provided the work meets all of the following criteria applicable to such work:
(i) The add-on fits tightly within the window or door opening with minimal or no subframe around the perimeter, and is set as far back from the plane of the exterior wall as possible;
(ii) The add-on will be made of wood, metal or fiberglass with a finish that matches the color of the primary window or door frame, with clear glass;
(iii) A window add-on will have horizontal mullions or meeting rails that match the primary window's meeting rail or substantial mullions, is placed in the same relative location, with no additional divisions;
(iv) A door add-on will have horizontal mullions only in conjunction with the rails of the primary door, with no additional divisions; and
(v) The installation of the add-on will not damage or destroy any significant feature of the window, door or building.
(2) Applied films. LPC Staff may approve an application for applied films on windows or doors at primary facades and visible portions of secondary facades, provided the work meets all of the following criteria applicable to such work:
(i) The applied film is clear or translucent and/or tinted in greyscale, except that only clear film may be used for special windows or doors;
(ii) The installation is on the interior face of the glass and is reversible; and
(iii) If translucent and/or tinted, the overall installation is limited in scope so as to not change the character of the overall fenestration of the building (for example, applied only at bathroom windows).
(e) Special Windows and Special Doors; Any Facade.
(1) If existing original or historic special windows or special doors are deteriorated beyond reasonable repair, as described in a condition assessment submitted by the applicant, new windows or doors may be approved if they match the original or historic windows and doors in terms of details, materials, operation, configuration and finish. The assessment should generally be prepared by a qualified architect or engineer; however, for more limited scopes of work a contractor or other professional with preservation experience may be deemed acceptable. For purposes of this subdivision, the criteria established for window replacement at Primary Facades of Individual Landmarks will be used, with the additional variations and exceptions as described in paragraph (f)(1).
(2) A window that is special due only to its glazing can be removed and reinstalled in a new window sash that otherwise complies with the relevant criteria for replacement of non-special windows.
(f) Primary Facades.
(1) General criteria. New windows or doors may be approved if they match the original or historic windows and doors in terms of details, materials, operation, configuration and finish. Historic doors may be replaced only if they are deteriorated beyond reasonable repair, as described in a condition assessment. For purposes of this subdivision, the following variations and exceptions apply, except as noted in each provision.
(i) Details. Variations in details will be permitted if such variations do not significantly affect the visual characteristics of the window or door. LPC Staff may approve a diminution of glazing area from the historic window not to exceed ten (10) percent for metal windows and six (6) percent for wood windows, except that the diminution percentages may be slightly exceeded for specific window types due to their small size or muntin pattern, or due to building, energy, accessibility or other code requirements that must be met, provided that LPC Staff determines that the proposed window will not call attention to itself or detract from the significant architectural features of the building. In addition to the window sashes, door leafs and frames, the new window's or door's muntins, mullions and brickmolds must also match the historic condition. Simulated divided light ("SDL") muntins are acceptable substitutes for true divided light muntins, provided the exterior muntins are built into the frames of the sashes and are of the same material and there are spacers between multiple layers of glass and interior muntins. At large residential and commercial buildings in historic districts, spacers and interior muntins are not required.
(ii) Materials.
(A) A historic wood window or door can be replaced with wood of any species. A historic metal window or door can be replaced with a different metal, including replacing metal-clad windows with a non-metal substrate material. However, Special Windows and Special Doors may require matching the original material exactly.
(B) At small residential and commercial buildings in historic districts, straight- and arch-headed, double-hung wood windows for which the historic condition had no divided lights (without muntins) may be replaced with windows of a different material, including aluminum and fiberglass, but not including vinyl, provided the historic wood brickmolds are retained or replicated in wood, aluminum or fiberglass; the new windows are installed in the same plane as the historic window; and the window and brickmolds have a matching finish that replicates the historic finish;
(C) If the historic transom window originally or historically had stained or leaded glass but did not retain such glass at the time of designation, the replacement window does not have to match the stained glass but can be either clear glass or recall the stained or leaded glass window.
(iii) Operation.
(A) The upper sash of a double-hung window, or of a transom window, may be fixed, and the direction of the swing (e.g., outward or inward) of a casement, awning or hopper window may be changed.
(B) Except at Individual Landmarks, the historic operation of the lower sash of a double-hung window may be changed to a hinged operation to meet high-performance energy-efficiency or accessibility standards or goals provided that:
(a) The operation of the lower sash is limited to an inward tilting hopper for ventilation, except for additional inward turning capabilities for maintenance purposes only, and the plane of the lower sash approximates that of the historic sash;
(b) The details closely match that of the historic double-hung window, with additional dimensional tolerances (typically deeper sashes and frames) to accommodate thicker insulated glazing and the change in operation at the lower sash, and such additional minor changes do not call attention to themselves or detract from the appearance of the building or adjacent buildings, if in a district; and
(c) All windows on the primary facades eligible for this exception, excluding special windows, are being replaced at the same time or as part of an approved master plan to ensure a uniform installation and appearance.
(C) The operation of a door must match the historic operation, except that the historic operation of a swinging door may be changed to fixed or reversed in swing or hinging; in addition, the historic operation of a swinging, sliding, roll-down or overhead garage or loading door may be substituted interchangeably;
(D) Except at Individual Landmarks, the historic operation of a pivot window may be changed to a hinged operation matching the vertical or horizontal orientation of the pivot operation; and
(iv) Configuration of a door. The following exception to matching the configuration of a historic door may apply if the door is not a Special Door or located on an Individual Landmark: the historic configuration of equal leaf paired doors may be changed to unequal leafs or a single leaf, if the applicant can demonstrate an inability to meet accessibility requirements through other modifications, provided that the new door(s) will match or recall the configuration and details of the historic door(s), and the work meets other relevant criteria in 63 RCNY § 2-18.
(2) Specific criteria for primary facades.
(i) Individual Landmarks.
(A) Existing original or historic window and door openings. If original or historic windows or doors are deteriorated beyond reasonable repair due to physical conditions as described in a condition assessment submitted by the applicant, new windows or doors will be approved if they match the original or historic windows and doors in terms of configuration, operation, details, material and finish. The assessment should generally be prepared by a qualified architect or engineer; however, for more limited scopes of work a contractor or other professional with preservation experience may be deemed acceptable.
(B) Existing non-original or non-historic window and door openings. If the window or door opening is not original or historic, or has been substantially modified, such as a window opening installed after the removal of a stoop and entrance door, or a door opening installed after the installation of a fire escape, a new window or door may be approved if it matches or otherwise harmonizes with the configuration, details and materials of the original or historic windows and doors on the building.
(ii) Small residential and commercial buildings in historic districts.
(A) Applicability. For purposes of this subparagraph, a small residential or commercial building is a building which is six stories or less in height and has a street frontage of forty (40) feet or less, and includes rowhouses, townhouses, mansions, detached and semi-detached houses and carriage houses; small apartment buildings, tenements and hotels; and small, utilitarian, commercial and loft buildings, including cast-iron fronted buildings, department stores, banks and office buildings. Notwithstanding the above, a corner rowhouse, town house, mansion, detached and semi-detached house and carriage house shall be deemed a small residential and commercial building regardless of the length of its longest street frontage.
(B) Existing original or historic window and door openings. New windows installed in existing original or historic openings will be approved if they match the historic windows in terms of configuration, operation, details, material and finish. If original or historic doors are deteriorated beyond reasonable repair due to physical conditions as described in a condition assessment submitted by the applicant, new doors replacing historic doors will be approved if they match the historic doors in terms of configuration, operation, details, material and finish, and new doors replacing non-historic doors will be approved if they match the historic doors in terms of operation, material and finish, and recall the configuration and details of the historic doors. The assessment should generally be prepared by a qualified architect or engineer, however for more limited scopes of work a contractor or other professional with preservation experience may be deemed acceptable.
(C) Existing non-original or non-historic window and door openings. If the existing window or door opening is not original or historic, or has been substantially modified, such as a window opening installed after the removal of a stoop and entrance door, or a door opening installed after the installation of a fire escape, the new window or door will be approved if it matches, or otherwise harmonizes with, the configuration, operation, details, material and finish of the historic windows and doors on the building. The design may maintain the existing opening or may include the modification of the height and width of the existing opening, and may introduce new architectural features on the area surrounding the opening, provided that:
(a) The design of the surround is consistent with or harmonious the materials and details of the building.
(b) For modifications to entrances at the base of the building, see 63 RCNY § 2-14(i).
(iii) Large residential and commercial buildings in historic districts.
(A) Applicability. For purposes of this subparagraph, a large residential or commercial building means a building that is seven or more stories in height, or has a street frontage of more than forty (40) feet, and includes large apartment buildings and hotels, and large commercial and loft buildings, including cast-iron fronted buildings, department stores, banks and office buildings.
(B) Existing original or historic window and door openings. New windows installed in existing original or historic openings will be approved if they match the historic windows in terms of configuration, operation, details and finish. New doors installed in existing original or historic openings will be approved if they recall the historic doors in terms of configuration, operation, details and finish.
(C) Existing non-original or non-historic window and door openings. If the existing window or door opening is not original or historic, or has been substantially modified, such as a window opening installed after the removal of a stoop and entrance door, or a door opening installed after the installation of a fire escape, the new window or door will be approved if it matches, or otherwise harmonizes with, the configuration, operation, details, material and finish of the historic windows and doors on the building. The design may maintain the existing opening or may include the modification of the height and width of the existing opening, and may introduce new architectural features on the area surrounding the opening, provided that:
(a) The design of the surround is consistent or harmonious with the materials and details of the building.
(b) For modifications to entrances at the base of the building, see 63 RCNY § 2-14(i).
(iv) Other buildings in historic districts.
(A) Applicability. For purposes of this subparagraph, "other buildings" include buildings such as churches and synagogues, hospitals, schools, libraries and the one- or two-story commercial building known as a "taxpayer."
(B) Existing original or historic window and door openings. New windows and doors installed in existing original or historic openings will be approved if they satisfy the criteria in set forth in paragraph (2) of subdivision (f) as determined by whether the other building type is seven or more stories in height or has more than forty (40) feet of street frontage.
(C) Existing non-original or non-historic window and door openings. If the existing window or door opening is not original or historic, or has been substantially modified, such as a window opening installed after the removal of a stoop and entrance door, or a door opening installed after the installation of a fire escape, the new window or door will be approved if it matches or otherwise harmonizes with the configuration, details, material and finish of the historic windows and doors on the building. The design may maintain the existing opening or may include the modification of the height and width of the existing opening, and may introduce new architectural features on the area surrounding the opening, provided that:
(a) The design of the surround is consistent or harmonious with the materials and details of the building.
(b) For modifications to entrances at the base of the building, see 63 RCNY § 2-14(i).
(v) Buildings in Scenic Landmarks.
(A) Applicability. This subparagraph shall apply to buildings in Scenic Landmarks that are not Individual Landmarks, and shall include such buildings as educational centers, sports-related buildings, utility buildings (including sheds and maintenance buildings), stables, carriage houses, garages, boat houses, historic houses, police stations, zoo buildings, theater and performance buildings, and comfort stations.
(B) Existing original or historic window and door openings. New windows and doors installed in existing original or historic openings will be approved if they satisfy the criteria in set forth in paragraph (2) of subdivision (f) as follows: buildings six or less stories in height and with less than forty (40) feet of primary facade shall follow the criteria in paragraph (2)(ii) of subdivision (f), and shall follow the criteria in paragraph (2)(iii) of subdivision (f) if taller or with more than forty (40) feet of primary facade.
(g) Secondary Facades; Visible Facades. This subdivision applies to new windows and doors, and modified and new window and door openings, at visible portions of secondary facades for all building types.
(1) Existing window and door openings. New windows and doors installed in existing openings, whether original, historic or modified, will be approved if they match the historic windows and doors in terms of configuration and finish.
(i) Existing window and door openings that do not contain a special window or door can be filled in provided:
(A) If the facade is masonry, the window and door opening will be filled in with new masonry to match the surrounding masonry, except if an original or historic window opening is being filled in, the new masonry must be set flush with but not toothed into the surrounding masonry, or set slightly back of the plane of the facade, and the lintel and sill retained, provided that the filled in openings will not detract from the existing windows or doors on the secondary facade or the primary facade if such filled in windows can be seen in conjunction with the primary facade. Notwithstanding the foregoing, original or historic window openings at the top floor of a building built as part of a row of identical or similar buildings, where the building retains its original height, cannot be filled in.
(B) If the facade is sided with wood, the window or door opening can be filled in with wood to match the existing facade, except at the top floor of a building that was built as part of a row.
(2) Modified and new window and door openings. New windows and doors installed in existing openings being modified by enlarging or reducing the opening in height and/or width, or new windows and doors installed in newly created openings, on visible portions of secondary facades will be approved if the modified or new opening, and the window or door, meet all of the following criteria as applicable:
(i) Modified and new window and door openings.
(A) A modified or newly created window or door opening will retain the same general shape and pattern as existing windows and doors on the same facade, or, where there are no existing openings, the newly created opening will be located in a place and be of a size and shape where it can form the basis for a regular and consistent pattern; and that the number, size or placement of the new window or door opening does not change the character of the facade as a secondary and subservient facade with a high solid to void ratio;
(a) With respect to proposals for creating new window or door openings at secondary facades of row houses or townhouses, mansions, detached and semi-detached houses and carriage houses, staff may approve new window openings provided that, together with the existing openings, there is no more than one window opening on a secondary facade of less than twenty (20) feet, two window openings if the facade is between twenty-one (21) and forty (40) feet, and 3 window openings if more than forty (40) feet; the placement, pattern and sizes of windows on the facade do not detract from significant architectural features of the buildings or neighboring buildings if in a district; and the original window openings on the top floor of a rear facade are not modified, with the exception of one window opening which may be lowered to provide access to an approved or grandfathered balcony, terrace or deck. However, previously altered window openings on the top floor of these building types may be enlarged or reduced to restore or more closely match the original window openings, as deemed appropriate by LPC Staff.
(b) No opening with a special window or door may be modified.
(ii) New windows and doors installed in modified and new window and door openings approved pursuant to subparagraph (i) of this paragraph will be approved if they match the historic windows and doors in terms of configuration and finish, and
(A) The new window or door will not replace a Special Window or Special Door;
(B) The new and/or modified window or door opening, and window or door, will not detract from the significant architectural features of the building or adjacent buildings by virtue of their proximity to such features.
(h) Secondary Facades; Nonvisible and Minimally Visible Facades. New and modified window and door openings, and new windows and doors installed in existing openings, new openings, and modified openings will be approved if the proposed work meets all of the following relevant criteria:
(1) New windows and doors in existing openings.
(i) LPC Staff will approve a new window or door in an existing opening, provided the window or door being removed is not a special window or special door, except that if the "Special Window" is limited to distinctive glazing, the glazing can be removed and installed in a new window and in a new location on the facade;
(ii) Existing window and door openings that do not contain a special window or door can be filled in with new masonry to match the surrounding masonry or filled in with new facade cladding to match the surrounding facade cladding for non-masonry facades, except at the top floor of a building built as part of a row or identical or similar buildings where the building retains its historic height, and provided that the filled in opening does not detract from the existing windows or doors on the secondary facade. One (1) original or historic window opening at the top floor of a building built as part of a row may be filled in, if the new masonry is set slightly back of the plane of the facade and the lintel and sill are retained.
(2) Modified window and door openings.
(i) Existing window and door openings on the same floor, except as provided below for the top floor and bottom two floors, may be modified by enlarging or reducing the opening in height and/or width or combining horizontally adjacent openings, provided that at least one bay of windows is not combined and the modified opening maintains the existing masonry wall or cladding at the outer piers, other mullions or muntins break down the scale of the window and the enlarged opening does not extend above or below a floor, and there are at least eighteen (18) inches between the enlarged opening and the windows above and below;
(A) With respect to the top floor, the historic window openings cannot be modified except that one window opening may be lowered to provide access to an approved or grandfathered balcony, terrace or deck, including a new Juliette-style balcony, and the modified window opening may be widened if necessary to meet minimum code requirements;
(B) With respect to the bottom two floor levels of the existing building, a modified window and door opening can combine all windows and doors on a floor, and may span vertically between the bottom two floor levels to create a single large opening, if the modified opening will maintain at least twenty-four (24) inches of masonry or wall cladding at the outer piers and between the floors above the modified opening, and provided there is a spandrel or horizontal element of at least twelve (12) inches that marks the location of the missing floor and other mullions or muntins that break down the scale of the window, except that if the modified window is to be installed in an addition or extension that does not extend the full width of the building, 12 (twelve) inches of masonry or wall cladding must remain at the outer piers; and
(ii) At intersecting facades, such as those occurring at partial rear extensions, modified and enlarged openings may not wrap continuously around the outside or inside corners and must maintain at least 12 (twelve) inches of separation with masonry or wall cladding.
(3) New window and door openings. The new opening must:
(i) Match or be consistent with the size and scale of existing openings and placed so as to be consistent with an existing pattern or to create a consistent pattern; or
(ii) Match or be consistent with the modifications to existing window and door openings provided for in this section; and
(iii) Not detract from significant architectural features of the building or adjacent buildings.
(4) New windows and doors in modified existing openings and in new openings. LPC Staff will approve new windows and doors to be installed in new openings and existing openings modified as permitted under this subsection, provided that:
(i) The new window or door does not detract from any significant exterior architectural feature of the building or neighboring buildings by virtue of its proximity to such feature(s); and
(ii) If the opening has been widened, combined horizontally and/or vertically, the new windows and doors are subdivided to give the window scale and texture and, for purposes of this subparagraph, sliding glass doors may be installed in a modified or new opening if the opening faces onto a deck or the ground.
(5) For purposes of this subdivision (h), a secondary facade is "minimally visible" if the facade is seen at such an angle that the configuration of the windows cannot be seen or is very difficult to discern, or only a small portion of the facade is seen through a gap in the streetwall and is visually disconnected from the primary facade of the building.
(i) Entrance Infill, Excluding Entrances in Storefront Infill. LPC Staff will issue an approval for new entrance infill for existing entrance openings (e.g., at primary and secondary entries for lobbies, vestibules, service areas or egress), but not including entrance openings in Individual Landmarks, where no significant historic fabric exists, if the proposed work will restore the historic infill pursuant to the requirements of 63 RCNY § 2-11(f) or meets all of the relevant criteria set forth below:
(1) Design. The design of the new infill is based on the historic entrance prototypes and details within the specific historic district and for buildings of similar age, type and style, except that entrance infill for a building that already has entrance infill approved pursuant to this section must be harmonious with the previously approved entrance infill in terms of the design, materials and finish. At commercial and mixed-use buildings where entrance infill and storefront infill was installed in similar openings historically, the entrance infill can also be removed and replaced with storefront infill pursuant to 63 RCNY § 2-12(c).
(2) Configuration. The configuration of the new infill is consistent with the proportions of doors, sidelights, transoms and other features of historic entrance infill or previously approved entrance infill.
(3) Door, transom and sidelight glazing. Glazing in doors, transoms and sidelights must be clear, except that a gray-scale translucent treatment may be applied the interior face of glazing where existing interior conditions preclude the installation of clear transom windows; or at a service entrance.
(4) Framing. Entrance framing must feature profiled trim that recalls the articulation of historic entrance framing, and the details will be traditional or contemporary, except that at small residential buildings the framing details must recall traditional framing.
(5) Orientation. New infill must be installed parallel to the building's sidewalk and consistent with the plane of the facade, and must be set back from the face of the existing entrance surround the minimum dimension required to avoid concealing any significant architectural feature, including features previously concealed by existing entrance infill, but in no event less than four (4) inches from the face of the entrance surround.
(6) Entrances and doors.
(i) The new entrance will be accessible if feasible or required by law; and
(ii) The design of the new door will maintain the design intent of new entrance infill required by this section, or will match the original or historic door pursuant to the criteria for door replacement addressed in subdivision (f) of this section.
(7) Material. If the building was constructed prior to 1900, the material of the new infill must match the historic material, if known, or be wood; for buildings constructed in or after 1900, or built before and altered in or after 1900 to include entrances, the material of the new infill may be wood or metal or match the historic material, except that:
(i) At small residential buildings of six (6) stories or less and with a street frontage of forty (40) feet or less, the material of the new infill must match the historic material, except that corner rowhouses, town houses, mansions, detached and semi-detached houses and carriage houses are subject to this clause regardless of the length of the facade with the longest street frontage.
(ii) Service entrances, such as those that historically accessed freight elevators or had other utilitarian uses, may be wood or metal regardless of when the building was constructed, in keeping with similar service entrances found within the specific historic district and for buildings of similar age, type and style.
(8) Finish. New entrance infill must have a finish that recalls the finish of historic or approved entrances or is otherwise harmonious with the building.
(9) Removal of modern cladding. If an applicant is proposing to remove modern cladding on the entrance or the area surrounding the entrance, the applicant must first perform probes of the material to see if historic material or elements exist behind the modern cladding.
(i) If significant historic material or elements exists underneath the cladding, the historic material must be restored and the new entrance can only be approved pursuant to 63 RCNY § 2-11(f).
(ii) If a significant portion of the historic entrance surround exists underneath the cladding, but no historic entrance infill remains, the entrance surround must be restored, pursuant to 63 RCNY § 2-11(f), as part of the application for new entrance infill under this paragraph.
(10) Restoration of the original entrance opening. If the original entrance opening has been reduced or increased in size the design may maintain the existing entrance opening, or may include the restoration of the height and width of the original opening, except that where interior conditions preclude restoration to the original height (e.g., later structural elements or existing interior roll gate housing or mechanical systems):
(i) The existing entrance opening may be enlarged or reduced to the greatest extent feasible; and
(ii) The design of the surround is consistent with or harmonious the materials and details of the historic base of the building.
(11) Modification of the existing entrance opening. If the existing entrance opening is not original to the building, the proposed work may maintain the existing entrance opening or may include the modification of the height and width of the existing opening, and may introduce new architectural features on the area surrounding the entrance, provided that the design of the surround is consistent or harmonious with the materials and details of the historic base of the building.
(Amended City Record 12/20/2018, eff. 1/19/2019)