BetaNYCLaw Reader
Contents
  1. Home
  2. NYC Rules
  3. Title 63
  4. Chapter 2
  5. Part 2 of 3

63 RCNY Chapter 2 Approval of Proposed Work on Designated Buildings and Structures, part 2 of 3

§ 2-15 to § 2-35: 14 sections.

§ 2-15. Additions: Rooftop and Rear Yard Additions or Enlargements

Open this section

(a) Applicability.

(1) This section addresses LPC Staff approvals for additions to existing buildings, including rooftop, rear and side yard additions. It does not apply to additions to buildings in scenic landmarks.

(2) This section does not apply to any building already subject to a District Master Plan that includes criteria for additions. (See 63 RCNY Chapters 4, 6 and 12, and the Sunnyside Gardens Historic District guidelines.)

(3) The design and installation of additions consisting of heating, ventilation and air-conditioning equipment must meet the requirements set forth in 63 RCNY § 2-21. Flues and chimneys that are part of an addition or that must be raised as a result of an addition are included in this section.

(4) For purposes of this section, "minimally visible" means the visibility of a portion of an addition or enlargement which, from its maximum point of visibility, when viewed from any public thoroughfare:

(i) Projects into the maximum line of sight from such public thoroughfare no more than twelve (12) inches in height if the addition or enlargement is less than sixty (60) feet above the ground, projects no more than 18 inches if the addition or enlargement is between sixty-one (61) and eighty (80) feet above the ground, and projects no more than 24 inches if the addition or enlargement is between eighty-one (81) and one hundred (100) feet above the ground, and projects no more than thirty-six (36) inches if the addition is more than one hundred (100) feet above the ground, and the visible portion of the addition does not span more than fifty (50) percent of the length of the facade it is seen above unless it is an open railing or other installation with a similar open quality; or

(ii) Otherwise does not call attention to itself or detract from any significant architectural features of the building or other buildings if in a historic district. In determining whether an addition does not call attention to itself or detract, LPC Staff will consider the following factors:

(A) The addition is visible at a significant distance;

(B) The addition is visible from limited vantage points, including through alleyways, yards, or similar open portions of sites which are not building sites;

(C) The addition is visible from an oblique angle; or

(D) The addition is visible in combination with other existing additions or structures that share a similar level of visibility.

(5) For purposes of this section, the term "primary facade" means:

(i) a facade fronting a street or public thoroughfare that is not a street, such as a mews or court;

(ii) A visible facade that possesses a level of design or significant architectural features that are commensurate with the building's street-fronting facade(s), and where such facade (A) faces but does not front a street, such as a setback facade, or (B) is part of a dominant massing element where at least one facade is street-fronting or street-facing, such as a tower element; and

(iii) A facade with a primary entrance to the building.

(b) Rooftop Additions of Occupiable Space; General Requirements. The following criteria apply to all additions of occupiable space approvable by LPC Staff, subject to specific exemptions described below. For purposes of this section, "occupiable space" means a room or enclosure and accessory installations that are intended for human occupancy or habitation.

(1) The addition is as-of-right for bulk, massing and height under the Building Code and the Zoning Resolution;

(2) The installation of the addition will not damage or remove a significant feature of the roof;

(3) The addition is not on top of an existing rooftop addition but may expand an existing addition horizontally, and is not more than one story, with a maximum height of eleven (11) feet as measured from the mid-point on the existing roof of the structure on which such addition is to be constructed; and

(4) The addition is back at least three feet from the plane of the rear facade.

(c) Rooftop Additions of Occupiable Space; Specific Requirements. In addition to the criteria set forth in subdivisions (b) and (g) of this section, the following criteria apply:

(1) Individual landmark. LPC Staff may approve an addition of occupiable space if the addition and any chimney or flue that needs to be raised because of the addition, or any railing associated with such addition, is not visible from a public thoroughfare.

(2) Building within a historic district. LPC Staff may approve an addition of occupiable space if:

(i) The addition is not visible from a public thoroughfare in connection with the primary facade, except that a required enlargement of an existing chimney and/or exhaust flue associated with the construction of the addition may be minimally visible in combination with either a primary or secondary facade where:

(A) The quantity and dimension of the flue extension will be limited to the greatest extent feasible;

(B) The proposed chimney or exhaust flue extension will be seen in combination with other existing additions, enlargements, or other construction of a comparable size; and

(C) The chimney or flue extension will not draw undue attention to itself or detract from significant features of the building on which it is located or neighboring buildings; and

(ii) The addition is not visible in connection with a secondary facade of the building or neighboring buildings, except that an addition constructed on top of a building seven (7) stories or greater in height can be minimally visible over a secondary facade.

(d) Rooftop Additions of Non-occupiable Space; Specific Requirements. In addition to the criteria set forth in subdivision (b), the following criteria apply to additions of non-occupiable space. For purposes of this subdivision, "non-occupiable space" means structures; stair and elevator bulkheads, skylights, satellite dishes, unenclosed decks, pergolas, trellises, and privacy screens, fences and railings. Criteria for the installation of heating, ventilation and air-conditioning equipment ("HVAC") and other equipment such as alternative or distributive energy equipment (including solar panels and wind turbines), batteries, water tanks and emergency generators and their dunnage, are codified in 63 RCNY § 2-21 ("Installation of Heating, Ventilation, Air Conditioning and Other Mechanical Equipment) of these rules.

(1) Individual landmarks.

(i) The addition or structure will not be visible in connection with the primary facade, except such addition may be minimally visible if installed more than sixty (60) feet above the ground; and

(ii) The addition or structure may be minimally visible in connection with a secondary facade if the addition:

(A) Will not be seen in connection with a distinguishing architectural feature; and

(B) Will be finished to blend with the predominant finish of the predominant material and/or finish of the secondary facade, or adjacent structures or comparable adjacent features so as not to call attention to itself.

(2) Building within a historic district.

(i) The addition or structure is no more than minimally visible in connection with the primary facade, provided the applicant demonstrates that it is not feasible to make the addition not visible, except that LPC Staff will approve work that increases visibility of an existing addition or structure if such increase is required by the Building Code or Fire Code and there is no feasible alternative. For purposes of this paragraph, LPC Staff will approve an elevator bulkhead adjacent to the front facade that is more than minimally visible where the elevator shaft is in its historic location, the elevator is not being extended to service an additional floor or floors, the bulkhead is the minimum necessary to meet relevant codes, the bulkhead is in a material and with a finish that relates to the primary facade or is utilitarian and does not call undue attention to itself, and buildings with elevator bulkheads adjacent to the front facade are commonly found in the historic district, including the Soho-Cast Iron Historic District and the SoHo-Cast Iron Extension, the Tribeca East, West, North and South Historic Districts, the NoHo Historic District, the NoHo East Historic Districts, The NoHo Extension and the Ladies Mile Historic District;

(ii) The addition or structure may be minimally visible in connection with a secondary facade of the building or neighboring buildings.

(e) New and Enlarged Dormers on the Rear Facade of a Building within a Historic District. LPC Staff may approve the installation of one or more non-visible dormers on a peaked or pitched roof, where such roof is considered a significant feature, where:

(1) The design and materials of the new dormer(s) will be in keeping with the style and type of dormers on buildings of a similar age and style, and will harmonize with the building's fenestration pattern; and

(2) The dormer(s) is to be constructed on a peaked or pitched roof facing the rear yard and:

(i) A new dormer or an enlarged dormer does not encompass the entire width of the roof, and the historic roof pitch is maintained for at least twenty-four (24) inches at both sides of the dormer; and

(ii) The highest point of the dormer is at least eighteen (18) inches below the existing ridgeline of the roof and set back at least eighteen (18) inches from the plane of the rear facade, unless the building is of a type or style that historically had a higher or lower dormer, and retains a portion of the roof below the dormer.

(f) Rear Yard Additions on Buildings in Historic Districts but not including Individual Landmarks. LPC Staff may approve a rear yard addition if the addition meets the following relevant criteria:

(1) The addition is not visible from a public thoroughfare;

(2) The addition is as-of-right for bulk, massing and height under the Building Code and Zoning Resolution;

(3) The proposed work satisfies the criteria for excavations (see 63 RCNY § 2-16, "Excavation");

(4) No significant architectural features, including but not limited to decorative lintels and/or sills, and projecting bays, but not including simple corbeled brickwork at the top of a facade or parapet, will be lost or damaged as a result of the construction of the addition;

(5) A majority of the buildings of a similar type that share the open space within the interior of the block, within the historic district, feature rear yard additions or els;

(6) The depth and height of the proposed addition is not deeper than the predominant depth or taller than the predominant height of additions or els on buildings of a similar type, and in no event shall the proposed addition rise to the full height of the rear facade, except that parapets and railings may extend above the predominant height of additions, up to forty-two (42) inches above the roof or deck surface of the addition required by the Building or Fire Codes, but must be at least fifty (50) percent open using railings at the facade of the addition facing the central open space of the block;

(7) The facade(s) of the addition recall(s) the character of rear facades and additions of buildings of its type within the historic district in terms of materials and fenestration, including:

(i) Traditional and modern materials and finishes at the facade facing the central open space, such as brick, stucco or fiber cement siding, but excluding exposed or painted concrete or concrete masonry units, vinyl siding, and exterior insulated finish systems ("EIFS"). The lot-line walls must have a neutral finished surface, but cannot be exposed or painted concrete or concrete masonry units or vinyl siding;

(ii) Window and door openings and configurations that will be consistent with the criteria established in 63 RCNY § 2-14 for new and modified windows and doors at minimally or non-visible secondary facades; and

(iii) If the work involves combining adjacent buildings the addition expresses the original width of each of the historic buildings.

(8) The proposed addition or enlargement will not extend to the rear lot line or substantially eliminate the presence of a rear yard; except an addition may be approved which fills in an enclosed central or side court that is not open to the rear yard, and the addition is no more than one story above the existing grade.

(9) Decks. A rear facade of a building, or an existing addition or proposed addition may include a projecting wood or metal deck that is minimally visible, provided the deck projects from the ground or parlor floor and extends no more than eight (8) feet from the facade it projects from, excluding steps from the deck down to the rear yard, but in no instance shall the deck intrude into a required rear yard. If the deck is proposed to be projecting from a proposed addition, the existence of the deck shall not be a factor in determining the depth of the proposed addition, as determined by paragraph (6) above.

(g) Rooftop and Rear Yard Additions; Cumulative Impact of Additions. LPC Staff will consider the cumulative impact of occupiable rooftop and rear yard additions when considering an application for an addition. LPC Staff will not approve a new occupiable rooftop addition if there is an existing or approved rear yard addition, but not including an original partial width "el", or a new rear yard addition if there is an existing or approved occupiable rooftop addition. For purposes of his subdivision, a deck above the rear yard off the historic rear facade shall not count as a rear addition. Nothing in this subdivision shall prevent LPC Staff from approving the rebuilding of an existing rear yard or rooftop addition.

(Amended City Record 12/20/2018, eff. 1/19/2019)

§ 2-16. Excavation

Open this section

(a) Introduction. Excavation on landmark sites or within historic districts must comply with all requirements of the Department of Buildings. The purpose of this section is to ensure that applicants demonstrate they have an understanding of the physical and structural conditions of the building and, where relevant, adjacent buildings, and to protect these buildings.

(b) Application Materials. Except for work exempt from these requirements as described in paragraph (5) of this subdivision, an application for excavation work must, in addition to any other plans and materials required for the work, include:

(1) A structural conditions report that addresses the building's age and original construction type, and the condition of the foundations and facades;

(2) A pre-construction site survey;

(3) A finished draft of the Department of Buildings Structural and Support of Excavation filing drawings;

(4) A plan for monitoring the facades of any building of six (6) stories or less which

(i) was constructed before 1901;

(ii) is constructed of wood;

(iii) has an unreinforced masonry foundation; or

(iv) has a foundation of stone or brick that is affected by or adjacent to the excavation; and

(5) An application for excavation that does not require underpinning, or requires only limited underpinning and does not occur at or adjacent to any designated building that falls under any of the categories described in paragraph (4), will not be required to include the additional materials listed in paragraphs (1) through (4) of this subdivision.

(c) Excavation Work. LPC Staff will issue a permit for excavation work as described below, provided the work meets all of the following criteria and pertains to:

(1) The lowering and replacing of the lowest existing floor slab (e.g., the basement or cellar) to increase the floor-to-ceiling height to no more than ten feet from floor to ceiling.

(2) The construction of new structural elements, or repairs to existing structural elements related to a building's infrastructure, including but not limited to footings and foundation walls, retaining walls, pits for elevators and escalators.

(3) The construction of new architectural elements, or repairs to existing architectural elements (including but not limited to light wells, stair-wells, sunken terraces, in-ground pools or water features, planting beds and other significant landscape features and significant re-grading); provided the LPC Staff determines the effect of such work will not substantially eliminate the presence of a rear yard, will provide for at least a five (5) foot unexcavated planting area at the rear of the lot, and will have no effect on significant architectural features of the building or adjacent buildings if the work is occurring within a historic district.

(4) The construction of a new crawlspace or cellar or basement story below an existing addition or new, approved addition, to a depth not to exceed the lowest story of the original building, taking into account a modification approved pursuant to paragraph (1) of this subdivision.

(5) The work will be designed and executed in compliance with Department of Buildings regulations under the supervision of a licensed professional engineer or registered architect, with the goal of protecting the building's facades and the facades of adjacent buildings.

(Amended City Record 12/20/2018, eff. 1/19/2019)

§ 2-17. Front, Side and Rear Yards

Open this section

(a) Alterations to Front Areaways of Rowhouses, Townhouses, Flats, Tenements and Other Attached Buildings.

(1) General. Areaways historically have been modified to address access and safety concerns, and to add greenery. This includes the addition of, and modification to, walls and fences around areaways, modification of the areaway itself, modifications to main entrances and entrances underneath stoops, and the addition of planting areas and planters.

(2) Alterations to areaway paving, steps, or planted areas. LPC Staff will issue an approval for alterations to or involving paving, steps or planted areas if the work meets all of the following relevant criteria:

(i) The work will be contained within the areaway, which is defined as the area in front of a rowhouse, townhouse, flat, tenement or other attached building typically constructed without a side yard, which often is enclosed by a fence, balustrade or wall;

(ii) The work will not result in the removal or destruction of significant architectural features;

(iii) The proposed paving materials are consistent with the paving materials historically found in areaways and yards of buildings of a similar age and type, or will match the adjacent sidewalk in terms of material and color;

(iv) The size and placement of the planted area, including at-grade planting beds and built-in or attached planters, will not call undue attention to itself or detract from significant architectural features of the building or adjacent buildings if in a historic district;

(v) Adjustments to steps or planted areas will not substantially alter the apparent grade of the areaway or yard. For purposes of this subparagraph:

(A) Lowering the entire areaway, including the removal of one step, to allow at-grade access from the sidewalk to the areaway;

(B) Excavation to accommodate new steps or reconfiguration of existing steps to improve access to a basement level entrance, including enlarging or widening steps, will be approved, provided:

(a) The excavation and steps will occupy fifty (50) percent or less of the square footage of the areaway;

(b) The excavation, steps and landing are in keeping with expanded basement entrances found on buildings of similar age and style within the historic district; and

(c) The excavation, steps and landing do not detract from significant architectural features of the building or, if the building is part of a row, do not detract from adjacent buildings or the streetscape;

(C) Excavation to construct a small ramp with no switchbacks to provide access to a basement entrance, which does not require railings or only minimal railings (such as well-mounted handrails or simple posts with top rails), provided the work does not affect more than fifty (50) percent of the areaway; and

(vi) The proposed areaway changes will be compatible with the special architectural and historic character of the building and the historic district.

(3) Garbage enclosures. LPC Staff will issue an approval for new or replacement garbage enclosures that are not easily moveable if the work satisfies all of the following relevant criteria:

(i) The work will be contained within the areaway defined by an existing fence, balustrade or wall, and will not result in damage to or the removal of architectural fabric from the building's facade, or areaway enclosure;

(ii) The garbage enclosure will not be physically attached to the building, areaway fence or wall, but instead will be attached to the areaway paving, but not through historic paving material;

(iii) The garbage enclosure will be of a simple design and painted to match the immediately adjacent facade or areaway enclosure material, or otherwise will have a neutral or dark finish that does not call undue attention to itself;

(iv) The enclosure will be limited in footprint and height to the general dimensions of the garbage receptacles it contains, and its size does not detract from the overall areaway proportions and configuration, or the building.

(4) Lampposts. LPC Staff will issue an approval for the installation of lampposts in the areaway, defined by an existing fence, balustrade or wall, if the work meets all of the following relevant criteria:

(i) The lamppost will not be installed through historic paving material;

(ii) The proposed lamppost will be situated at least several feet from the primary facade so as not to directly obscure significant architectural features;

(iii) The proposed placement of the lamppost relates to the spacing of elements within the areaway, such as the steps, planted areas and under-stoop entrance, and does not conflict with the facade's composition;

(iv) The proposed installation will not result in exposed conduit;

(v) The lamppost and lantern will be of a simple and proportional design, and will not exceed the sills of the parlor (or second) floor windows in height;

(vi) The lamppost and lantern will be metal and have a black painted finish; and

(vii) The proposed lamppost is in keeping with similar lamppost and areaway configurations within the streetscape and historic district.

(5) Basement/cellar level access hatches. LPC Staff will issue an approval for basement/cellar access hatches if the work satisfies all of the following relevant criteria:

(i) The proposed hatch will not be installed through historic paving material where feasible;

(ii) The placement of the hatch will not damage or directly obscure any significant architectural features of the building; and

(iii) The hatch will be constructed in wood or metal with a dark or neutral finish, in keeping with similar utilitarian installations.

(b) Installation of New Ironwork.

(1) Scope. This subdivision concerns applications for ironwork on top of areaway or stoop walls, or at alleyways, where the building has not previously had such ironwork of a type found on similar building types. For example, many stoops have been altered over time by the addition of handrails on the side or on top of stoop walls. Applications to restore or re-create original or historic ironwork must be made consistent with the criteria set forth in 63 RCNY § 2-11.

(2) New ironwork at areaways, stoops, service alleys or facades where no historic ironwork exists. LPC Staff will approve such work as follows:

(i) The installation of the new ironwork will not conceal, damage, or cause the removal of significant architectural features;

(ii) The new ironwork, with respect to its location on the building or property (e.g., on top of the areaway wall or stoop wall) and its scale and visual characteristics (including details and finish), will match or recall ironwork typically found on buildings of similar age, style and type; and where the building is part of a row, it is harmonious with other ironwork in the row;

(iii) The installation of the new ironwork will be harmonious with the special architectural and historic character of the building and the historic district.

(c) Walls and Fences.

(1) Scope. This subdivision concerns applications for walls and fences at small residential buildings, including rowhouses, townhouses, flats, and tenement buildings. LPC Staff will approve proposals that satisfy the criteria set forth below:

(i) New areaway wall or fence.

(A) The new wall or fence will not conceal, damage, or cause the removal of significant architectural features; and

(B) The scale, visual characteristics and location on the building or property of the new wall or fence will be in keeping with the age and style of the building, and, where the building is part of a row, is harmonious with other walls or fences in the row.

(ii) New fences at small residential buildings, including rowhouses, townhouses, flats and tenement buildings.

(A) LPC Staff will issue an approval for a rear yard fence if the work meets all of the following relevant criteria:

(a) The fence will not exceed six (6) feet in height;

(b) The fence will have a perforated or open design, which can include a portion of the fence being solid, if installed along the sidewalk at a corner building; and

(c) The fence will be constructed in wood or iron, whichever is most compatible with the building's age and style, and finished in a dark or neutral color, or clear finish. If visible, the design and finish of a metal fence should be simple and based on ironwork found in the district on buildings of similar type. If the fence is made of wood, the finished side must face away from the property if installed at the sidewalk of a corner rowhouse.

(d) Variations in material will be considered if the fence is not visible from a public thoroughfare and otherwise complies with applicable codes.

(e) A masonry wall, but not including cement masonry units enclosing a rear yard shall be approved if not visible and is no more than six (6) feet in height.

(B) LPC Staff will issue an approval for a metal picket fence at the side yard of a corner rowhouse if the work meets the following relevant criteria:

(a) The fence will match the height of an areaway fence but shall not exceed 36 inches in height;

(b) The fence will be simply designed and have a black or dark finish.

(2) Garden historic districts. This paragraph applies to proposals to install walls and fences in garden-style houses and apartment buildings in districts designated in part for the relationship between gardens and plantings and the buildings, including but not limited to buildings in the Sunnyside Gardens Historic District and the Jackson Heights Historic District. LPC Staff will approve applications for walls and fences if the following relevant criteria are met:

(i) Sunnyside Gardens Historic District. In the case of the Sunnyside Gardens Historic District, a new rear yard fence will be approved by LPC Staff if the fence:

(A) Will enclose the immediate rear yard behind the building that was not part of what was historically the shared common space. An application to enclose some or all of the rear yard that was historically part of the shared common space must be accompanied by proof that the restrictive easement providing for common space has lapsed and is no longer in place;

(B) Will not exceed thirty-six (36) inches in height; and

(C) Will be constructed of metal picket fencing with a dark finish.

(ii) Jackson Heights Historic District. In the case of an apartment building in the Jackson Heights Historic District, a new fence will be approved by LPC Staff if the fence:

(A) Will be limited to the planting area around the building;

(B) Has a black painted metal picket design that has an open quality; and

(C) The curb and fence combined will not exceed thirty (30) inches in height.

(iii) Jackson Heights Historic District. In the case of an original single- or two-family house in the Jackson Heights Historic District, LPC Staff will approve a low brick retaining wall at the border of the sidewalk and front yard if:

(A) The retaining wall will be as short as possible to contain erosion and in no event is higher than five brick courses, inclusive of a coping of brick or cast stone;

(B) The brick will closely match the brick facade of the building;

(C) The retaining wall will not feature decorative brickwork or ironwork;

(D) The retaining wall will not incorporate a perpendicular run from the sidewalk to the house, except a return to meet the lower stairs, which would divide the continuous front lawns of the row; and

(E) The retaining wall will match the height and design of an adjacent low garden wall that meets the requirements of this section or, if there is no adjacent retaining wall, is compatible with other low retaining walls on the block that meet the requirements of this section in terms of height and design.

(3) Free-standing houses. LPC Staff will issue an approval for the installation of a fence at free-standing houses if the work satisfies all of the following relevant criteria:

(i) The fence will be placed in the side or rear yard, behind the street-facing facade(s);

(ii) The fence will not exceed six (6) feet in height and is constructed of wood with the finished side facing away from the property;

(iii) Variations in the height and material will be considered if the fence is not visible from a public thoroughfare or the fence is permanently obscured from view by vegetation and the building otherwise complies with applicable codes.

(d) Driveways.

(1) General criteria.

(i) New driveway. LPC Staff will approve a new driveway only in districts where driveways are a common feature. As a general matter, these districts are comprised of what were historically detached single-family dwellings. If there is currently no existing curb cut, the applicant must provide documentation that the new curb cut will comply with the Zoning Resolution and the City Administrative Code, and that the applicant has filed for the curb cut with the Department of Buildings and the Department of Transportation.

(ii) Proposals to install a driveway or parking pad within the areaway or front yard of an attached or semi-attached house, or a row house, will require review by the full Commission at a Public Hearing.

(2) Specific criteria. LPC Staff will issue an approval to repair, alter or replace an existing driveway, and for a new driveway and a curb cut at the front, side or rear yard, if the work satisfies all of the following relevant criteria:

(i) Repair, alteration and replacement of an existing driveway.

(A) Repairs will match the existing driveway in terms of materials, details and finish;

(B) The existing footprint of a driveway may be altered by widening or creating a bump-out for turning or parking, provided the materials match the existing materials; the alterations do not significantly reduce the amount of green space of the yard; and the driveway is well scaled to the yard and building;

(C) Replacing an existing driveway. The materials and design of an existing driveway may be replaced as follows:

(a) If the existing driveway is an original or historic driveway and retains its original material and design, the replacement must match the material and design but the footprint may be altered as provided in clause (B) of this paragraph;

(b) If the existing driveway is not an original or historic driveway, it may be replaced with a driveway with different materials and design provided the new driveway satisfies the criteria of clause (E) of subparagraph (ii) of this paragraph.

(ii) New driveway where none currently exists.

(A) The installation of the driveway and curb cut will not eliminate any significant architectural feature, paving, or fabric from the building or site;

(B) The proposed location and design of the driveway and curb cut will be consistent with other buildings found in the historic district;

(C) The driveway will not significantly reduce the open and planted space within the yard and will not result in the loss or damage of a significant landscape improvement or feature identified in the relevant designation report;

(D) The driveway and curb cut are well scaled to the yard and building; and

(E) The proposed driveway paving materials match the predominant paving material and pattern within the streetscape, except staff may approve a substitute paving material that recalls the predominant paving material if the substitute meets applicable standards for improving the permeability of the paved surface and otherwise does not detract or call undue attention to itself.

(e) Accessory Ramps. LPC Staff will issue an approval for an accessory ramp for loading or other service functions that are not intended or required for barrier-free access, if the work satisfies all of the following relevant criteria:

(1) It is located within a service alley, or side or rear yard of a large apartment, hotel, or commercial building;

(2) The installation will be significantly obscured by existing masonry walls or ironwork;

(3) The proposed installation or any required excavation will not result in damage to or the removal of significant architectural features or historic fabric, including historic paving;

(4) The ramp will not block a window or obscure any significant architectural features of the building;

(5) The ramp will have no switchbacks and will be constructed in a material that matches the predominant paving or facade material, or is otherwise neutral in appearance and does not detract from the building or streetscape; and

(6) The railings will be simply designed or based on existing ironwork found on the building, and will have a black or neutral finish.

(Amended City Record 12/20/2018, eff. 1/19/2019)

§ 2-18. Barrier-Free Access

Open this section

(a) Introduction.

(1) Historic structures can and should be made accessible.

(2) Accessible routes should coincide with or be located in the same general area of regular circulation paths, and the primary entrance should be accessible wherever possible.

(3) Proposed alterations to make a building or space accessible must comply with applicable statutes and codes, including the American National Standard (ANSI), the New York City Building Code, and the Americans with Disabilities Act Standards for Accessible Design.

(4) Applications for barrier-free access should take into consideration changes to interior spaces that may reduce grade changes at the entrance which will lessen the level of impact of, or eliminate the need for, exterior changes.

(5) Where there is more than one acceptable approach for making a building or space accessible, LPC Staff will approve the proposal that will allow barrier-free access with the least impact on significant architectural features of the building and neighboring buildings if the work is occurring in a historic district.

(6) Where proposed alterations to make a building accessible will have a major impact on significant architectural features, LPC Staff may ask an applicant to seek a waiver. Accessibility waivers may be granted by the Department of Buildings after consulting with the Mayor's Office of People with Disabilities. If no waiver is granted the application shall be reviewed by the full Commission at a Certificate of Appropriateness public hearing.

(7) Proposed work that does not conform to these rules, such as a wheelchair platform lift on an Individual Landmark, will be reviewed by the full Commission at a Certificate of Appropriateness public hearing.

(b) At-Grade Entrances. LPC Staff may issue a permit for a proposal to lower an existing entrance at a building in a historic district or a building in a scenic landmark that is not an individual landmark to provide an accessible at-grade entrance if the work meets all of the following relevant criteria:

(1) The work required to bring the entrance to grade, including the removal of the existing steps, landings, ramps, or other elevated elements at the entrance point, will not result in damage to or the removal of significant architectural features of the building, except as noted below;

(2) Except as note below in clause (4), the proposal involves dropping or raising the entrance no more than eighteen (18) inches at a prominent primary entrance and no more than thirty (30) inches at other entrances to the building;

(3) Historic materials and features removed in connection with the work will be re-used where possible;

(4) If the treads contain cast iron vault lights, only one tread can be removed to create the at-grade entrance and the tread is installed flush at the entry to recall the presence of the vault lights;

(5) A sidewalk may be modified, including sloping a sidewalk to make an entrance accessible, provided the work meets the requirements of 63 RCNY § 2-19;

(6) A new door for the modified entrance shall have proportions that recall the historic door, which may require the addition of a transom to the door opening; and

(7) The proposed work will allow for barrier-free access for the building in the least obtrusive manner possible.

(c) Door and Door Surround Changes. LPC Staff may issue an approval for proposals to alter doors and door surrounds for buildings in historic districts and scenic landmarks that are not individual landmarks to meet accessibility requirements, such as clearance, if the work meets all of the following relevant criteria:

(1) If the existing door is original or historic:

(i) The proposed work will retain the historic fabric at the entrance, such as sidelights, door(s), transoms, framing or door surround detailing; and

(ii) Historic doors and vestibule entrances may be altered with respect to door swing, changing hardware and hinges, and the installation of automatic opener hardware provided the door configuration and details are maintained.

(2) If the existing door is not original or historic:

(i) The proposed work will retain a maximum amount of historic fabric at the entrance, such as sidelights, transoms, framing or door surround detailing;

(ii) The door opening may be widened up to eight (8) inches if necessary to meet applicable codes, provided that the door surround is recreated in-kind with the necessary adjustments for the new door opening;

(iii) The operation of replacement doors may be altered to meet required clearances, such as paired doors that may be changed to a single door with a fixed leaf or sidelight condition, or a single door with the appearance of paired doors;

(iv) The width of operable leafs and sidelights may vary from the historic condition provided that the replacement door(s) recalls the historic detailing and general configuration;

(v) A replacement door in an alternate material may be installed to meet force limitations in operating the leaf;

(vi) The replacement doors and accompanying elements must recall the historic condition in terms of configuration, detailing, material (if it meets code), and finish; and

(vii) The proposed changes to the door and door opening will not detract from the special architectural and historic character of the building.

(d) Actuators for Automatic Doors. LPC Staff may issue an approval for proposals to install an actuator device if the work meets all of the following relevant criteria:

(1) Door actuators installed on building facades.

(i) The push plate or actuator will be as small as feasible and located in the least obtrusive place possible;

(ii) The actuator will not be installed through decorative features or cast iron;

(iii) The actuator will be installed on flat unornamented masonry, brick, or metal, or at non-historic storefront infill, at a door return or side of a plain masonry pier, and will be attached through mortar joints or seams to minimize damage to historic fabric. Such proposed installation will to the greatest extent feasible not result in exposed conduit; and

(iv) The installation will not call undue attention to itself or otherwise detract from significant architectural features of the building or adjacent buildings.

(2) Door actuators installed on free-standing bollards, stanchions or posts (collectively "posts"). If the actuator cannot be installed pursuant to paragraph (1) of this subdivision due to facade conditions or other constraints, LPC Staff will approve an actuator installed on a post where the post is:

(i) Installed into non-historic paving;

(ii) Simply designed and finished to match the adjacent facade material or other neutral finish; and

(iii) The post will be an unobtrusive presence in conjunction with the facade and will not detract from or obscure any significant architectural features of the building.

(e) Handrails and Areaway Alterations.

(1) LPC Staff will issue an approval for a proposed handrail on an existing stoop or areaway steps on a building in a historic district or scenic landmark if the work meets all of the following relevant criteria:

(i) The installation of the handrail will not damage any decorative features of the masonry stoop walls, ironwork, or areaway enclosure;

(ii) The handrail will be simply designed and will not detract from the significant architectural features of the building; and

(iii) The handrail will be attached to the coping of the stoop wall, inside the stoop wall, or at the treads, whichever location the LPC Staff determines is the least obtrusive, taking into account other such installations on the block and the purpose of the handrail.

(2) LPC Staff will issue an approval for a proposal to alter an areaway enclosure to accommodate an accessible entrance:

(i) If the areaway enclosure consists of historic ironwork or masonry, the alterations are as minimal as possible to meet accessibility requirements and the ironwork and/or masonry is finished to match the historic condition; and

(ii) If no historic fabric exists in the areaway, the ironwork and/or masonry is finished to match the existing conditions.

(f) Ramps. LPC Staff may issue an approval for certain ramps as specified below. For purposes of this subdivision, a "ramp" includes the associated landing(s) and any steps integrated into the ramp.

(1) Ramps without handrails. Ramps that do not require a handrail may be approved on individual landmarks and buildings in historic districts and scenic landmarks if:

(i) The installation will not result in damage to significant historic fabric, including sidewalk paving materials or vault lights, steps and landings, or will involve the removal or modification of discrete portions of historic fabric, and the fabric that is removed is re-used in connection with the ramp work where possible;

(ii) The ramp will be constructed in materials to match the immediately adjacent facade material or sidewalk and threshold paving, or with utilitarian materials with a neutral finish so as to have an unobtrusive presence on the building;

(iii) The ramp will be as short as possible, with no switch-backs, except that LPC Staff may approve a longer ramp, with no switch-backs, if the longer ramp will have less visual impact on the facade; and

(iv) The proposed changes will not detract from the special architectural and historic character of the building.

(2) Ramps with handrails. Ramps that require a handrail may be approved for buildings in historic districts and scenic landmarks that are not individual landmarks if:

(i) The installation of the ramp and handrails will not eliminate or conceal any significant architectural features of the building or sidewalk, or landscape feature if in a scenic landmark, except as provided for below;

(ii) The installation is obscured or partially obscured by existing architectural features where possible, such as ironwork or masonry walls;

(iii) The ramp will be as short as possible, with no switch-backs and intermediate landings, except that LPC Staff may approve a longer ramp, with no switch-backs, if they determine that the longer ramp will have less visual impact on the facade;

(iv) For storefronts, the ramp will be confined to the storefront or building associated with the entrance being made accessible;

(v) For buildings with deeply recessed entrance courts or areaways, a ramp must be located within the recess, unless LPC Staff determines that a different location provides equal accessibility with less impact on the building;

(vi) The presence and location of the ramp will not disrupt, or will be consistent with, the facade's composition. For purposes of this rule, steps and landing leading to the entryway that are extending outward to receive the ramp should retain the historic orientation where feasible, and the favored position for a ramp in a recessed court or areaway is presumed to be off to one side so that it is as inconspicuous as possible, but, depending on the facade's composition, LPC Staff may determine that another location is more consistent and harmonious with the design of the facade;

(vii) Minimal excavation will be permitted to facilitate barrier-free access;

(viii) The handrail will be simply designed with the minimum number of vertical elements permitted;

(ix) The ramp will be simply designed and constructed in materials to match the immediately adjacent facade material or ironwork, or with utilitarian materials with a neutral finish, whichever will result in the least obtrusive presence on the building; and

(x) The proposed work will not detract from the special architectural and historic character of the building, district or scenic landmark.

(g) Lifts. LPC Staff may issue an approval for a wheelchair platform lift or a chair lift on a rail on a building in a historic district or scenic landmark, other than an individual landmark, if the proposed work meets all of the following relevant criteria:

(1) Wheelchair platform lifts.

(i) The lift will not require significant alterations to existing fabric at the proposed location, and any such alterations are reversible;

(ii) Only minimal historic fabric will be removed to access the lift at the elevated position;

(iii) The lift will be located in a recessed location on the facade, or otherwise located to not disrupt the facade's composition, and will be obscured or partially obscured by existing features such as ironwork or masonry walls;

(iv) The lift will be stored in the down position to minimize its visual presence; and

(v) The lift will be finished to match the immediately adjacent facade materials, or will have a neutral finish; and

(vi) The proposed work will not detract from the special architectural and historic character of the building, streetscape or scenic landmark.

(2) Wheelchair and chair lifts on rails.

(i) The installation does not require any significant alterations to the existing areaway, stoop, handrail, or building facade, and is reversible;

(ii) The installation will require minimal attachment points through non-decorative elements; and

(iii) The lift will be painted to match the finish of the adjacent ironwork or masonry, or will have a neutral finish.

(iv) The proposed work will not detract from the special architectural and historic character of the building, streetscape or scenic landmark.

(h) Replacement or Modification of Existing Commission-Approved or Grandfathered Ramps and Lifts. If an applicant can demonstrate that it is not feasible to replace or modify an existing ramp to meet the requirements of this section, LPC Staff may issue an approval to modify or replace an existing Commission-approved or grandfathered ramp or lift to meet current accessibility codes if the work meets all of the following relevant criteria:

(1) The replacement ramp will match or be smaller and/or shorter than the existing ramp in terms of footprint and overall rise, or is altered to the minimum degree necessary for compliance;

(2) The replacement ramp will be constructed using materials that either match the materials and handrail design of the existing ramp or match the adjacent facade material and/or railing, or utilitarian materials with a neutral finish. A change in handrail design to the minimum number of vertical elements required by code is permitted;

(3) The platform lift and guiderails will be installed in the same locations using existing penetrations in the building facade or other elements. Some additional penetrations may be approved if required to meet code.

(4) The lift mechanicals will be located in the same location and will match the footprint and height of the existing mechanicals, or will be reduced in size;

(5) The lift may be fully enclosed if necessary to meet code; and

(6) The previously approved finishes will be maintained or modified to better blend with the adjacent facade material.

(Amended City Record 12/20/2018, eff. 1/19/2019)

§ 2-19. Sidewalks

Open this section

(a) General Requirements.

(1) Scope. Except as otherwise provided in subdivision (h), this section applies to sidewalk replacement in historic districts where the paving material is a significant feature (e.g., bluestone, granite and brick) or the location of the sidewalk is a significant feature (e.g., "ribbon sidewalks where there is a planted area between the curb and the sidewalk not limited to tree pits) and where the existing sidewalks adequately recall the historic paving, either by the amount of historic paving that remains or due to the combination of historic paving and tinted sidewalks that exists in the district, or the location of the sidewalk. For purposes of this section, the term "sidewalk" means the portion of the sidewalk and curb fronting upon specific property.

(i) Appendix A of this section sets forth the list of historic districts that are subject to the provisions of this section, except as otherwise provided in subdivision (h). These historic districts are districts where historic paving was a significant feature and where there currently exists sufficient historic or tinted paving to adequately recall this historic condition. For these districts the long-term regulatory goal is to replace non-historic paving with paving that matches the historic paving material in terms of standard characteristics or which adequately recalls the historic paving material through a tinted concrete.

(ii) For historic districts designated after the effective date of these rules, the designation report must explicitly state whether the sidewalk paving is a significant feature and will be subject to these rules. The Commission will maintain a list on its website and at its offices of all historic districts subject to this rule.

(iii) In all other historic districts no approval is required from the Commission for replacing sidewalks.

(2) Other approvals. In addition to the requirements set forth in this section, all methods and materials for sidewalk work must conform to all applicable rules, requirements and guidelines of the Department of Transportation ("DOT") and the Department of Design and Construction.

(b) Repairing, Resetting and New Bluestone Sidewalks. LPC Staff will issue an approval to repair and/or reset existing bluestone pavers, or to install new bluestone pavers, if the work satisfies all of the following relevant criteria:

(1) Resetting and repairing existing bluestone pavers. If intact pavers exist, they must be preserved if they meet applicable DOT standards for thickness and size, and must be reset pursuant to DOT standards. Small amounts of cementitious patching, tinted to match the color of the pavers, can be applied to preserve existing pavers that have spalled, and the joint between pavers may be ground down to produce a level surface.

(2) New bluestone pavers. If the existing sidewalk is missing one or more bluestone pavers, or the existing bluestone pavers are beyond reasonable repair due to cracking or other conditions, or the owner is proposing to install a new bluestone sidewalk where no bluestone exists, new bluestone pavers may be installed, consistent with the DOT specifications and installation requirements, if:

(i) The pavers will closely match the existing bluestone pavers, if any, with respect to dimension, color and paver pattern; and

(ii) The edges of the pavers can be sawn, rubbed or thermal.

(3) Consolidation of existing bluestone pavers. If the existing sidewalk is missing bluestone pavers, or some of the existing bluestone pavers are beyond the point of reasonable repair due to cracking or other conditions, the existing bluestone pavers that meet DOT standards for thickness and size may be consolidated and tinted concrete pavers installed in the remaining area, provided:

(i) The maximum number of intact bluestone pavers will be consolidated within the sidewalk;

(ii) Resetting of bluestone pavers will meet the requirements of paragraphs (1) and (2) of this subdivision;

(iii) New concrete pavers are tinted and scored to match the historic bluestone pavers;

(iv) An existing bluestone or granite curb will be retained if possible, and any replacement curb will be granite or tinted / untinted concrete to match adjacent curbing; and

(v) For purposes of this paragraph and subdivision (h) of this section, if the enlargement of an existing sidewalk tree pit or sidewalk planting area, or the installation of a new tree pit, sidewalk planting area or bioswale requires the removal of some or all of a bluestone paver:

(A) The removal of bluestone will be the minimum necessary to meet the applicable requirements, and

(B) The bluestone paver, or the part that is removed, will be consolidated within the property lines if there are areas of the sidewalk that do not have bluestone pavers, provided the paver, or part thereof, otherwise meets applicable DOT standards.

(c) Replacement of an Existing Non-Bluestone Sidewalk. Where the property on which the sidewalk exists is not part of a bluestone sidewalk, and the owner does not intend to install a new bluestone sidewalk consistent with the requirements of subdivision (b), the new sidewalk must:

(1) Consist of concrete pavers scored to match the size of pavers on adjacent sidewalks, with saw-cut joints. If the sidewalk is adjacent to a bluestone or bluestone-tinted concrete sidewalk the new sidewalk must be tinted to match the bluestone. If the sidewalk is not adjacent to a bluestone or bluestone-tinted concrete sidewalk the sidewalk may be either untinted concrete to match the adjacent sidewalk or bluestone-tinted concrete; and

(2) An existing bluestone or granite curb will be retained if possible, and any replacement curb will be bluestone, granite or tinted / untinted concrete to match adjacent curbing.

(3) Unique or decorative scoring patterns may be used at front entryways of large apartment buildings, hotel or commercial buildings in historic districts if there is evidence that the building once had such decorative paving or if decorative scoring is a characteristic of the building type (e.g., hotel, large apartment building or club building) and the design does not call undue attention to itself or detract from the significant architectural features of the building or streetscape.

(4) Metal post plates, and/or bolt holes associated with detachable flood protection barriers, may be installed in concrete sidewalks, provided the post plates are set flush with the sidewalk and the installation does not call undue attention to itself or detract from the building or streetscape.

(d) Vault Lights. LPC Staff will issue an approval to repair or replace existing vault lights, re-create missing vault lights, or recall the presence of missing historic vault lights with diamond plate if the proposed work satisfies all of the following relevant criteria:

(1) New vault lights.

(i) New vault lights may be approved to restore missing vault lights, or to replace existing vault lights, whether uncovered or covered by diamond plate steel or concrete, that are beyond reasonable repair;

(ii) New vault lights will match the existing or historic vault lights in terms of approximate panel size and overall footprint, material, finish and details;

(iii) Where no vault lights exist, the basis for the design and materials of the new vault lights will be based on photographic or physical evidence relating to the building or adjacent buildings, or, if no documentation exists, the design and materials will be based on vault lights found at buildings of similar age, style and type;

(iv) New vault lights may be set flush with the existing sidewalk over the original or new metal framing or over a solid concrete substrate where the historic condition occurred at grade, or set on the original or new metal platform where the historic condition was raised above grade.

(2) Protection of existing uncovered and deteriorated vault lights. Existing uncovered vault lights that are in a deteriorated state and are no longer water-tight may be protected by covering the vault lights with dark-finished diamond plate steel. Vault lights at vertical surfaces and lower-traffic areas such as steps and landings should remain uncovered where feasible.

(3) Protection of existing covered vault lights.

(i) Existing vault lights that are covered by diamond plate steel or concrete may be re-covered with new dark-finished diamond plate steel;

(ii) If the existing vault lights underneath the diamond plate or concrete are highly deteriorated or broken, they may be removed and replaced with new vault lights in accordance with paragraph (1).

(4) Replacing diamond plate. If no vault lights are present under existing diamond plate steel, the diamond plate steel will be replaced with new dark finished diamond plate steel, except that if the historic district in which the building exists is not characterized by vault lights and/or diamond plate, the staff may approve replacing the diamond plate with concrete to match the adjacent concrete.

(e) Granite Sidewalks. LPC Staff will issue an approval to repair or reset existing granite sidewalks, or to install new granite sidewalks, and new concrete pavers tinted to match the existing granite pavers, if the work satisfies all of the following relevant criteria:

(1) The maximum number of intact granite pavers will be maintained or consolidated within the property lines;

(2) Areas no longer covered by granite pavers will be replaced with new granite pavers or concrete pavers tinted and scored to recall the size of the historic granite pavers and saw cut;

(3) Existing granite pavers will be sliced horizontally to create new or lighter pavers, provided that (i) the footprint of each paver is maintained and the paver is reinstalled in approximately the same location, and (ii) the resulting paver(s) will maintain a minimum of three to four (3 - 4) inch thickness and otherwise meet DOT requirements and comply with Department of Buildings structural requirements; and

(4) New granite pavers will match the color, texture, dimensions and edge treatment of the existing granite pavers and will have a slip-resistant finish in accordance with DOT requirements.

(f) Other Sidewalk Materials. LPC Staff may issue an approval to repair, reset or replace in-kind sidewalks of different historic materials, such as Belgian Block, brick or special concrete aggregates, provided such material is typically found in the district. For ribbon sidewalks, defined as sidewalks located with a grass or planting strip between the sidewalk and the curb, the material should match the historic material or the predominant material in the district, and the width of the sidewalk is not increased. For unique or atypical sidewalk treatments, such as a brick sidewalk in front of a carriage house in a district characterized by bluestone sidewalks, or a special sidewalk approved by the Public Design Commission or its predecessor, LPC Staff may require repair or in-kind replacement if the sidewalk treatment represents a significant historic alteration or if removal is deemed to result in the loss of a significant historic feature.

(g) Accessible Sidewalks.

(1) Pedestrian ramps at sidewalk intersections. LPC Staff will issue an approval to install accessible pedestrian ramps at sidewalk intersections if the proposed work satisfies all of the following relevant criteria:

(i) For new or existing concrete sidewalks, accessible pedestrian ramps will consist of tinted concrete to match the color, texture and scoring of the adjacent or predominant sidewalk paving;

(ii) For existing bluestone and granite sidewalks, bluestone or granite pavers may be cut, honed or otherwise modified to form the slope and flared sides of the ramp, or replaced in kind to accommodate the ramp. In addition:

(A) If the existing sidewalk is predominately bluestone or granite, but the portion of the sidewalk at the intersection that needs to be modified is concrete, the ramp may consist of concrete tinted to match the adjacent historic paving material;

(B) Existing bluestone or granite at the corner may be cut and moved within the property lines to replace missing or deteriorated bluestone pavers, and a concrete ramp, tinted to match the adjacent historic paving material, installed at the corner; or

(C) Existing bluestone or granite sidewalks will remain and a concrete "neckdown" (an expansion of the sidewalk at the intersection into the road to shorten the pedestrian crosswalk) tinted to match the adjacent paving installed to accommodate the ramp and preserve the historic paving material in place;

(iii) Detectable warning units, designed to alert people who are vision impaired that they are at an intersection, may be surface applied or imbedded into the concrete or stone; and

(iv) The dimensions and slope of the ramp, and color differentiation for detectable warning units comply with applicable federal, state and city codes and requirements.

(2) Sloping sidewalks. LPC Staff will issue an approval to slope a sidewalk in order to make a store or space accessible if the work will not damage or detract from historic paving or, if the sidewalk is concrete, the color and scoring pattern of the concrete matches the existing sidewalk, and the work complies with all applicable federal, state and City codes and requirements, including the requirements of 63 RCNY § 2-18, and provided that the work will not result in damage to or concealment of significant architectural features of the building.

(h) Street trees, sidewalk planting beds and bioswales. Street trees and their associated planting pits, sidewalk planting beds and bioswales provide important environmental and social benefits, including providing shade and cooling, cleaning the air and absorbing rainwater and runoff, which have important functions in addressing climate change impacts in urban and suburban settings. LPC does not regulate the trees or plantings, unless specifically referenced in the designation report or through historical documentation, but only the physical change to the sidewalk to accommodate them. Every application to expand or install a new tree pit or planting area in the sidewalk area must also be approved by the New York City Parks Department. In historically residential areas, and in some cases commercial areas, the presence of these features is commonplace and has existed since the blocks were developed or shortly thereafter. LPC Staff will issue an approval to enlarge existing tree pits and sidewalk planting beds, or to install new tree pits, sidewalk planting beds and bioswales, if the work satisfies all of the following relevant criteria:

(1) Existing tree pits or planting beds in portions of sidewalks abutting the curb of the streetbed may be enlarged to accommodate tree roots or otherwise provide additional area for planting beds and bioswales.

(2) Tree pits, planting beds and bioswales may abut and/or connect continuously across property lines, however in no case should three or more properties be connected continuously, to maintain at least minimal separation of these in elements in keeping with the typical historic condition of the sidewalks, unless a continuous planning area is documented as a historic condition at the site or district.

(3) Tree pits, planting beds and bioswales should generally be limited to the course of paving parallel to and abutting the sidewalk curb, and any enlargements perpendicular to the curb should be the minimum amount necessary as determined by an arborist due to the potential disruption to the pattern and clearances of the remainder of the sidewalk abutting the buildings, areaways and/or yards of the properties.

(4) Modification of curbs for bioswales. Work affecting existing curbs must comply with the requirements of this section with respect to replacement material, except that a portion of an existing curb can be removed or lowered if such work is necessary for the installation or operation of a bioswale.

(5) This subdivision applies to all sidewalks under the jurisdiction of the LPC, and not just the sidewalks in the historic districts listed in Appendix A.

Appendix A: Historic Districts Having Continued Sidewalk Regulation

Addisleigh Park Historic District African Burial Ground and The Commons Historic District Audubon Terrace Historic District Bedford Historic District Bedford Stuyvesant / Expanded Stuyvesant Heights Historic District Boerum Hill Historic District Brooklyn Academy of Music Historic District Brooklyn Heights Historic District Carroll Gardens Historic District Charlton-King-Vandam Historic District Chelsea Historic District Chelsea Historic District Extension Clinton Hill Historic District Cobble Hill Historic District Cobble Hill Historic District Extension (3 buildings) Ditmas Park Historic District Douglaston Historic District DUMBO Historic District Eberhard Faber Pencil Historic District Fieldston Historic District Fiske Terrace-Midwood Park Historic District Gansevoort Market Historic District Governors Island Historic District Gramercy Park Historic District Gramercy Park Historic District Extension Greenpoint Historic District Greenwich Village Historic District Hunters Point Historic District Jumel Terrace Historic District Ladies' Mile Historic District Manhattan Avenue Historic District Metropolitan Museum Historic District Noho East Historic District NoHo Historic District NoHo Historic District Extension Park Slope Historic District Park Slope Historic District Extension Park Slope Historic District Extension II Prospect Park South Historic District Riverdale Historic District Sniffen Court Historic District SoHo-Cast Iron Historic District SoHo-Cast Iron Historic District Extension South Village Historic District South Street Seaport Historic District South Street Seaport Historic District Extension St. George/New Brighton Historic District St. Mark's Historic District Extension St. Mark's Historic District St. Nicholas Historic District St. Paul's Avenue-Stapleton Heights Historic District Stone Street Historic District Stuyvesant Heights Historic District Stuyvesant Square Historic District Tribeca East Historic District Tribeca North Historic District Tribeca South Historic District Tribeca South Historic District Extension Tribeca West Historic District Vinegar Hill Historic District Wallabout Historic District

(Amended City Record 12/20/2018, eff. 1/19/2019; amended City Record 7/20/2023, eff. 8/19/2023)

§ 2-20. Health, Safety and Utility Equipment

Open this section

(a) Introduction. Buildings may be required to have a variety of equipment related to particular health, safety and utility maintenance. These types of installations can be mandated by the Fire and Building Codes (e.g., fire alarm bells and Siamese connections) or by utilities (e.g., gas and electricity meters). Other equipment is not required by law but is commonly used for safety reasons (e.g., window security bars, security cameras, lighting and intercom panels). Given the relatively small and/or discrete nature of these types of installations, their physical requirements and constraints, and their ubiquitous presence throughout the city, these types of equipment can be installed without having a significant effect on architectural features or detracting from such features or the building or, in the case of buildings in historic districts, from adjacent buildings or the streetscape.

(b) General Installation Criteria. LPC Staff may issue an approval for work on individual landmarks, buildings in historic districts and scenic landmarks to install health, safety and utility equipment, such as the examples listed below in subdivision (c), if the proposed work meets all of the following relevant criteria:

(1) The installation will not occur on or in front of a primary facade unless there is no feasible alternative for the installation or the location is mandated by another law or rule. In making a determination that there is no feasible alternative, LPC Staff will consider whether the need for such equipment on the primary facade is necessitated by recent or related discretionary interior renovations;

(2) The equipment will be attached in a manner that minimizes damage to, or loss of, any significant architectural features and will be installed at mortar joints or through plain brick, stone or wood to the greatest extent possible;

(3) If the installation is proposed to be made through areaway or sidewalk paving, the installation will not be installed through historic paving unless there is no feasible alternative;

(4) If the installation is required by applicable law or rule it will be as small as feasible;

(5) The finish of the equipment if not otherwise required by law or rule, will match the surrounding building material or will not call undue attention to its presence;

(6) If the installation requires a conduit: there will be no visible conduit or, if this is not feasible, a maximum of approximately ten (10) inches of visible conduit will be permitted; the conduit will not be placed on decorative surfaces; the visible conduit will be painted to match the background surface and will be secured into mortar joints where possible; and, if there are multiple proposed or existing installations, the proposed installation of conduit will, to the maximum extent feasible, combine and minimize the amount of conduit;

(7) The installation will be either not visible from a public thoroughfare or as minimally visible as possible (e.g., beneath a band course, underneath a stoop, behind an areaway wall or fence, or behind plantings). Unless the installation meets the requirements of paragraph (1) of this subdivision, the installation will be on a secondary facade; and

(8) The proposed installation will not call undue attention to itself or detract from any significant architectural feature(s) of the building or of adjacent buildings if the work is occurring in a historic district, by virtue of its size or proximity to any such features or buildings.

(c) Certain Types of Equipment and Additional Criteria. The following are the types of installations addressed by this section, including, where appropriate, installation criteria that are in addition to the general criteria set forth in subdivision (b) of this section:

(1) Utility meters, including electrical, gas and water meters.

(2) Fire alarm bells.

(3) Light fixtures and intercom panels. These installations must be installed within the door opening or adjacent to the door opening, and will be limited to a maximum of two light fixtures and one intercom panel per door opening, except that an intercom panel may also be installed on a fence or wall in front of the entranceway.

(4) Security cameras. These installations must be as small and as limited in number as feasible, with no more than two (2) security cameras for every twenty-five (25) feet of street frontage for small residential or commercial buildings of six (6) stories or less and with a street frontage of forty (40) feet or less, and no more than three (3) security cameras for every twenty-five (25) feet of street frontage for larger commercial, residential and institutional buildings. In every case the security camera(s) will be located to avoid a cluttered or haphazard appearance, and must be attached in a manner and location that minimizes their visible impact.

(5) Hookups for temporary generators and boilers, electrical boxes, inverter boxes.

(6) Mailboxes and mail key lockboxes. These installations must be installed within or adjacent to the door opening. If a building has a stoop, the mailbox may be attached to a gate or door underneath the stoop or, provided the installation meets the requirements of paragraphs (1), (2), (3), (4), (5) and (8) of this subdivision, to the facade of the building or stoop adjacent to the doorway underneath the stoop. A mailbox may also be attached to an areaway fence, or may be free-standing in the areaway if the attachment does not damage original or historic fabric or call undue attention to itself or detract from significant features of the building or adjacent building.

(7) Exterior Siamese connections/standpipes, oil fill pipes, boiler and dryer vents, water spigots.

(8) Rooftop security fences installed between properties. These installations may be installed only on small commercial buildings or large commercial or residential buildings, provided that they:

(i) Will not cause damage to any significant architectural feature of any facade or the roof;

(ii) Will be as low as is practicable and allowed by the Fire Code or the Building Code;

(iii) Will not be installed in front of or below a cornice where there is a continuous cornice line; and

(iv) Will either not be visible or will be minimally visible, or the visibility will be in the context of other rooftop features and will not call undue attention to itself or detract from the significant architectural features of the building or adjacent buildings.

(9) Certain heating, venting or air-conditioning equipment ("HVAC"). HVAC (including air intakes or exhausts at basement, cellar or areaway windows, walls or floors) that, due to existing structural or other physical constraints, must be installed below the second story at or in front of the primary facade or visible secondary facade. Staff may decide not to approve such installation if staff determines that the structural or other condition necessitating such installation was the result of recent or related discretionary interior changes.

(10) Window security bars installed at cellar, basement or parlor floor windows. These installations may be installed on any building, provided they:

(i) Will not cause damage to any significant architectural feature of any facade;

(ii) Will match historic ironwork or be of a simple design and will not call undue attention to themselves or detract from the significant architectural features of the building;

(iii) Will fasten to the window frame or surround at limited attachment points, and will not include continuous perimeter framing.

(11) Security gates at door openings below or under stoops. These installations can be installed on any building, provided that they:

(i) Will not cause damage to, or detract from, any significant architectural feature of any facade;

(ii) Will match historic ironwork or be of a simple design and will not call undue attention to itself or detract from the significant architectural features of the building;

(iii) Will fasten to the door surround at limited attachment points, and will not include continuous perimeter framing.

(iv) If replacing a grandfathered door where no door existed originally or historically, a new door may be approved if it maximizes the amount of transparency, with or without new ironwork, in keeping with the appearance of open gates below stoops.

(12) Detachable flood protection barriers. Penetrations through plain areas of the facade (excluding decorative masonry or metalwork, and cast iron) at discrete locations for mechanical fastening of flood barriers, with plugs finished to match the surrounding material, and permanent posts at service and garage door openings and loading bays, with associated hardware finished to match the surrounding material or otherwise neutral in finish, may be installed, provided the installation does not call undue attention to itself or detract from the building or streetscape.

(Amended City Record 12/20/2018, eff. 1/19/2019)

§ 2-21. Installation of Heating, Ventilation, Air Conditioning and other Mechanical Equipment

Open this section

(a) Introduction. These rules set forth criteria for LPC Staff approval of heating, ventilation and air conditioning ("HVAC") or other mechanical equipment in buildings which are designated landmarks or are within designated historic districts or scenic landmarks. These rules are based on the following principles:

(1) The distinguishing historical qualities or character of a building or its site should be protected. The removal or alteration of any significant architectural feature should be avoided.

(2) The visual integrity of the building's exterior walls should be maintained.

(3) In general, HVAC and other mechanical equipment are part of a building's infrastructure that must be installed in compliance with various building and energy codes, and health and safety standards. These codes and standards change over time due to technological advances, and as a result of the changing needs of occupants.

(4) HVAC and other mechanical equipment play a critical role in the sustainability and resiliency of historic buildings. Applicants are encouraged to install appropriate HVAC and mechanical equipment that meet or exceed the requirements of the New York City Energy Conservation Code, even if the equipment is exempt from such standards.

(5) Applicants are strongly encouraged to develop building master plans for the installation of HVAC equipment, which will facilitate expeditious review and approval of applications.

(b) Definitions.

Decorative masonry. The term "decorative masonry" means terra cotta, cast-stone or natural stone (such as limestone, marble, brownstone or granite) and brick facade areas and/or any ornamental feature which is a component of the facade such as belt courses, banding, water tables, cornices, corbelled brick work, medallions, enframements, and surrounds, and ornamental bonding patterns, e.g., tapestry or diaper brick patterns. The term does not include entirely plain units of stone, masonry or brick laid up with simple, non-decorative coursing.

HVAC equipment. The term "HVAC equipment" includes through-window, through-wall, rooftop, areaway, and facade and yard mounted heating, ventilation, and air conditioning equipment, including louvers, wall-mounted louvers and stove, restaurant, bathroom and/or dryer vents.

Mechanical equipment. The term "mechanical equipment" means equipment other than HVAC equipment, such as solar and wind power equipment, batteries and emergency generators, and including any associated elements such as safety railings and sound attenuation screens, baffles and other structures.

Minimally visible. The term "minimally visible" means visibility of any portion of the HVAC or other mechanical equipment which, from its maximum point of visibility, when viewed from any public thoroughfare:

(1) Projects into the maximum line of sight from such public thoroughfare no more than twelve (12) inches in height if the equipment is less than sixty (60) feet above the ground, projects no more than eighteen (18) inches if the equipment is between sixty-one (61) and eighty (80) feet above the ground, and projects no more than twenty-four (24) inches if the equipment is between eighty-one (81) and one hundred (100) feet above the ground, and projects no more than thirty-six (36) inches if the equipment is more than one hundred (100) feet above the ground; or

(2) Does not call attention to itself or detract from any significant architectural features of the building or other buildings if in a historic district. In determining whether equipment does not call attention to itself or detract the LPC Staff will consider the following factors:

(i) The visibility meets the requirements of paragraph (1) above;

(ii) The equipment is visible at a significant distance;

(iii) The equipment is visible from very limited vantage points, including through alleyways, yards, or similar open portions of sites which are not building sites;

(iv) The equipment is visible from an oblique angle; or

(v) The equipment is visible in combination with other existing equipment, additions or structures that share a similar level of visibility.

Primary facade. The term "primary facade" means:

(1) A facade fronting a street or public thoroughfare that is not a street, such as a mews or court;

(2) A visible facade that possesses a level of design or significant architectural features that are commensurate with the building's street-fronting facade(s), and where such facade (i) faces but does not front a street, such as a setback facade, or (ii) is part of a dominant massing element where at least one facade is street-fronting or street-facing, such as a tower element; and

(3) A facade with a primary entrance to the building.

Secondary facade. The term "secondary facade" means a facade that does not front on a street or a public thoroughfare and that does not possess significant architectural features that are commensurate with the street fronting facade.

Terms not otherwise defined in these rules have the meanings ascribed to them in the Landmarks Law.

(c) Installations of HVAC Equipment Within Window Openings.

(1) No permit required. No permit is required for installing seasonal and non-permanent HVAC equipment in windows if the following relevant criteria are satisfied:

(i) Seasonal window air-conditioning unit installations.

(A) The installation requires only raising or lowering the sash of a double-hung window, or opening the sash of a casement, hopper or awning window or transom, and temporarily fixing the sash in place without removing it;

(B) The window unit and any filler panel (glazed or solid) will be installed at any location within the window frame, and will not fully rest on an architectural element of the facade outside of the window frame, such as a cornice, parapet or sill; and

(C) The support brackets, if required, will fasten to the window frame or the interior side of the wall opening, and/or may brace against the exterior wall without mechanical attachments.

(D) If the installation is visible from a public thoroughfare, the window unit does not need to be painted; however, any filler panel (if solid) must have a finish that matches or approximates the color of the window frame.

(ii) New non-permanent louver and vent installations.

(A) The installation requires only the raising or lowering of the sash of a double-hung window, or opening the sash of a casement, hopper or awning window or transom, and temporarily fixing the sash in place without removing it;

(B) The louver or vent, and any filler panel (glazed or solid), will be installed at any location within the window frame; and

(C) If the installation is visible from a public thoroughfare, the louver or vent, and any solid filler panel, will have a finish that matches or approximates the color of the window frame.

(2) Permit required. A permit, certificate or report is required for all other types of HVAC equipment installations within windows in individual landmarks and buildings in historic districts and scenic landmarks.

(i) Primary facades. Installations of HVAC equipment within window openings on primary facades of Individual Landmarks and building in historic districts and scenic landmarks, where there is no feasible alternative to installing the HVAC equipment on a secondary facade.

(A) Rowhouses, detached houses, carriage houses, small apartment buildings, tenements, and hotels. Except for installations on the primary facade that meet the requirements of 63 RCNY § 2-20, for buildings originally constructed as private residences (rowhouses, town houses, detached and semi-detached houses) or carriage houses, as well as small apartment houses and other types of multiple dwellings which are six (6) stories or less in height and with a street frontage of forty (40) feet or less, the small scale and potential for affecting the significant architectural and historic character of the buildings require that proposals for installations on primary facades be reviewed by the full Commission for a Certificate of Appropriateness ("C of A") or report.

(B) Large apartment buildings and hotels and commercial and loft buildings. This clause (B) applies to large apartment buildings, hotels and other types of multiple dwellings that have a street frontage of more than forty (40) feet or are seven (7) or more stories in height, and all commercial and loft buildings originally designed to serve commercial, retail or warehouse uses, including cast-iron fronted buildings, department stores, banks and office buildings. LPC Staff will approve permanent installations of HVAC equipment, louvers and vents in window openings if the proposal meets the following relevant criteria:

(a) The window is not a special window as defined in 63 RCNY § 2-14; and

(b) The installation involves removing only glazing or modifying or removing the window sash and retaining the window frame. At large apartment buildings and hotels, only one of the double-hung sashes or a portion of a casement window assembly may be removed. If the exterior louver is flush-mounted, it will be mounted flush with or behind the plane of the window frame and behind the existing or reinstated brickmold or panning. If the window unit is projecting, it will be mounted within the window frame. In either case, if the exterior louver or window unit fills only a part of the window frame, it can be placed anywhere within the modified or removed sash, and the remainder will be filled with a filler panel (glazed or solid) or partial height window sash to otherwise match the configuration, size permitting, of the overall window; or

(c) The installation involves installing the exterior louver or projecting window unit in conjunction with installing a new window at the same time, and the resulting installation complies with both the criteria set forth in this clause (B) and the applicable new window criteria; and

(d) The exterior louver and any solid filler panel will be finished to match the window frame; however, a window HVAC unit does not need to be painted; and

(e) The installation will not damage or remove a significant architectural feature of the building and, for buildings in historic districts, will not detract from the significant architectural features of adjacent buildings.

(ii) Secondary facades. Installations of HVAC equipment within window openings on secondary facades of Individual Landmarks and buildings within historic districts and scenic landmarks. LPC Staff will approve the installation of HVAC equipment if the proposal meets the following relevant criteria:

(A) The window is not a "special window" as defined in 63 RCNY § 2-14;

(B) The installation will occur within an existing window opening, either as an exterior louver, projecting window unit or a small vent with a flush or minimally projecting cap and filler panel, set back from the plane of the facade to approximate the depth of the window; or

(C) The installation will occur in conjunction with installing a new window at the same time, and the resulting installation complies with both the criteria of this subparagraph and the applicable new window criteria; and

(D) If the installation is visible from a public thoroughfare,

(a) The installation is only part of the full height of the sash being removed, the remainder will be filled with a filler panel (glazed or solid) or partial height window sash to otherwise match the configuration, size permitting, of the overall window; or

(b) The installation involves an exterior louver or small vent with a flush or minimally projecting cap, the louver, vent, cap and solid filler panel will be finished to match the window frame; and

(E) The installation will not damage or remove a significant architectural feature of the building and, for buildings in historic districts or scenic landmarks, if visible will not detract from the significant architectural features of adjacent buildings.

(d) Installations of Through-Wall HVAC Equipment.

(1) Primary facades. Through-wall installation of HVAC equipment on primary facades.

(i) Individual Landmarks. Except for installations on the primary facade that meet the requirements of 63 RCNY § 2-20, proposals for through-wall installations on primary facades must be reviewed for a C of A.

(ii) Buildings within historic districts.

(A) Through-wall installations approvable only by C of A. Except for installations that meet the requirements of 63 RCNY § 2-20, proposals for installations of through-wall HVAC equipment on primary facades of the following building types must be reviewed for a C of A due to their small scale, limited areas of plain masonry and/or the potential for affecting significant the significant architectural and historical character of the buildings:

(a) Rowhouses, townhouses, detached and semi-detached houses, carriage houses, flats, small apartment buildings, tenements, hotels and other types of multiple dwellings. For purposes of this item (a), this means buildings originally constructed as private residences, carriage houses or multiple dwellings, which are six (6) stories or less in height and with a street frontage of forty (40) feet or less, except that a corner rowhouse, townhouse, detached or semi-detached house or carriage house may have one street frontage that is larger than forty (40) feet;

(b) Manufacturing and loft buildings, originally designed to serve commercial, retail, or warehouse uses, including cast-iron fronted buildings, department stores, and banks.

(B) Through-wall installations approvable by LPC Staff. LPC Staff will approve through-wall installations if the proposal meets the following relevant criteria:

(a) Large apartment buildings, hotels and other types of multiple dwellings which either have a street frontage greater than forty (40) feet or which are seven (7) or more stories in height, if the proposal meets all of the following relevant criteria:

(1) The installation will be centered beneath the window opening, or, if the window opening is wide enough to accommodate more than one set of sashes, is placed beneath the window opening in accordance with the predominant existing pattern of through-wall installations;

(2) The exterior louver will be a rimless type architectural louver with flat metal blades;

(3) The exterior louver will be mounted as flush as possible with the surrounding masonry and with the minimum projection feasible;

(4) The exterior louver will be finished to match the color of the surrounding masonry;

(5) The location corresponds to a regular pattern of installations, or where demonstrated to be impractical or unfeasible, the location will form the basis for a new pattern of installations or will otherwise not detract from the facade or, if in a historic district, adjacent buildings; and

(6) The installation will not damage or remove decorative masonry or a significant architectural feature of the building and will not detract from the significant architectural features of adjacent buildings. For purposes of this clause (B), removal of small areas of plain masonry to accommodate the through-wall unit shall not be considered damage or removal of a significant architectural feature.

(iii) Other buildings. For other buildings that do not fall into any of the previously described categories, including specialized building types such as churches and synagogues, hospitals, schools, and libraries, with a street frontage of more than forty (40) feet or are seven (7) or more stories in height, LPC Staff will approve through-wall installations of HVAC equipment if they determine that:

(A) There is no feasible alternative to installing the HVAC equipment on the primary facade;

(B) The installation will satisfy the criteria set forth in subdivision (d)(1)(ii)(B)(a)(2)-(4) of this section; and

(C) The installation will not damage or remove a significant architectural feature of the building, or detract from such features of the building or adjacent buildings if in a historic district. For purposes of this item (b), removal of small areas of plain masonry or non-decorative brick to accommodate the through-wall unit shall not be considered damage or removal of a significant architectural feature.

(2) Secondary facades. LPC Staff will approve the installation of through-wall HVAC equipment on a visible secondary facade of any building if the proposal meets the following relevant criteria:

(i) The unit will be:

(A) Centered beneath or above a window opening if the vent or louver exceeds one hundred forty-four (144) square inches in surface area; or

(B) Installed below, above, or to the side of a window opening if the vent or louver is one hundred forty-four (144) square inches or less in surface area; or

(C) Installed in a uniform pattern on portions of secondary facades devoid of windows (variations from the predominant existing pattern on the building may be permitted if the applicant does not have interior space which would permit such installation in conformance with such pattern). For purposes of this paragraph (2), louvers greater than one hundred forty-four (144) square inches shall only be permitted through a masonry facade; and

(ii) The exterior louver will be mounted as flush as possible with the exterior wall or facade cladding and with the minimum projection feasible, except that if the louver is one hundred forty-four (144) square inches or less in surface area, a minimally projecting cap may be permitted if the projection does not call undue attention to itself or otherwise have an adverse effect on the secondary facade; and

(iii) The exterior louver will be finished in a manner which approximates the color of the surrounding facade cladding; and

(iv) No decorative masonry or other facade cladding, or other significant architectural feature of the building, will be affected by the installation, and the installation will not detract from adjacent buildings. For purposes of this subparagraph (iv), removal of small areas of plain masonry or other facade cladding to accommodate the through-wall unit will not be considered damage or removal of a significant architectural feature.

(3) Installation of HVAC equipment on non-visible secondary facades. LPC Staff will approve the installation of through wall HVAC equipment on a non-visible secondary facade of any building if the proposal meets the following relevant criteria:

(i) The installation will not be visible from any public thoroughfare; and

(ii) The exterior louver will be mounted as flush as possible with the surrounding masonry or facade cladding, except that if the opening is one hundred forty-four (144) square inches or less in surface area, a minimally projecting cap may be permitted if the projection does not have an adverse effect on the secondary facade; and

(iii) No decorative masonry or other decorative facade cladding, or any significant architectural feature of the building, will be affected by the installation.

(e) Wall Mounted Installations of HVAC and Other Mechanical Equipment on Secondary Facades. LPC Staff will approve the installation of wall mounted HVAC and other mechanical equipment on secondary facades if the proposal meets the following relevant criteria:

(1) Visibility.

(i) Wall mounted HVAC, such as ductless split system HVAC equipment and other mechanical equipment on platforms and/or brackets, may be minimally visible from a public thoroughfare. Such equipment may be more than minimally visible if they are seen in conjunction with utilitarian features (e.g. fire escapes; fences) that mitigate the presence of the new equipment, will be located in the least visible location so as to not disrupt the composition of the facade, and will not protrude further from the side facade than required by relevant laws. Such installations may include a screen to conceal the equipment. In scenic landmarks, such installations may be made minimally visible by the introduction and maintenance of plantings;

(ii) Wall-mounted flues and ducts required by applicable governmental laws and rules (including, but not limited, to Building, Fire and Health Codes) may be minimally visible from a public thoroughfare, or where more than minimally visible, will be located in the least visible location and so as to not disrupt the composition of the facade, and will not extend higher than required by such laws or rules;

(2) The attachment of associated platforms, brackets and straps to the facade will be designed to maximize reversibility and minimize damage to the building fabric (e.g., installed through the mortar joints where possible in masonry walls);

(3) Any penetrations for associated conduits or ducts through the facade will be as small as possible in conformance with the manufacturer's recommended dimensions;

(4) If the installation is visible from a public thoroughfare, the HVAC and other mechanical equipment, flues and ducts, and associated platforms, brackets and straps, will have a finish that matches the color of the underlying material, or is otherwise neutral so as to not call attention to itself; and

(5) The installation will not damage or remove a significant architectural feature of the building and, for buildings in historic districts, if visible will not detract from the significant architectural features of adjacent buildings.

(f) Installation of HVAC Equipment in Storefronts and Storefront Doors. LPC Staff will approve the installation of HVAC equipment in storefronts and storefront doors if:

(1) The installation involves removing only glazing, or modifying or removing the transom window sash and retaining the storefront or door frame.

(i) The exterior louver will be mounted flush with or behind the plane of the transom window frame and behind the existing or reinstated brickmold or panning, and

(ii) If the exterior louver will replace only part of the transom window sash being removed, the remainder of the space will be filled with a flat panel (glazed or solid) or partial height transom window sash to otherwise match the finish and configuration, size permitting, of the overall transom window; or

(2) At recessed storefront entrances only, the installation involves removing only glazing, or modifying or removing the transom window sash and retaining the storefront or door frame, and the window unit (projecting or flush) will be mounted within the transom window frame, and if the window unit only fills part of the opening, it can be placed anywhere within the modified or removed transom window sash, the remainder will be filled with a filler panel (glazed or solid) or partial height transom window sash finished to otherwise match the finish and configuration, size permitting, of the overall transom window; or

(3) The installation involves installing the exterior louver in conjunction with installing a new storefront or door at the same time, and the resulting installation complies with both the criteria in this subdivision and the applicable new storefront or door criteria set forth in 63 RCNY § 2-12; and

(4) The exterior louver and any solid filler panel will be finished to match the storefront or door frame; or

(5) The installation will be through a non-historic storefront bulkhead, integrated into the design of the bulkhead or will otherwise not detract from the storefront; and

(6) The exterior louver will be rimless with horizontal blades finished to match the color of the surrounding storefront bulkhead, and will be mounted as flush as possible with the surrounding material and the minimum projection feasible; and

(7) The installation will not damage or remove a significant architectural feature of the building and, for buildings in historic districts, will not detract from the significant architectural features of adjacent buildings.

(g) Installation of HVAC and Other Mechanical Equipment on Rooftops or Terraces. With respect to individual landmarks and buildings in historic districts and scenic landmarks, LPC Staff may approve the installation of HVAC and other mechanical equipment on rooftops and terraces if the proposal satisfies the following relevant criteria:

(1) Primary facade.

(i) The installation will not damage or remove significant architectural features.

(ii) The installation will not be visible. If it is not practicable or feasible to make the installation not visible, and the visibility is not caused by the equipment being placed on an LPC-approved addition, LPC Staff may approve a minimally visible installation.

(iii) With respect to existing HVAC installations, LPC Staff may (A) approve work that increases existing visibility slightly if such increase is required by building or fire codes or for compliance with energy or environmental codes, laws or standards and there is no feasible alternative; and (B) approve replacement of a grandfathered or approved installation with a matching or smaller, one even if the new installation is more than minimally visible, provided there is no feasible alternative location that would be not visible or minimally visible, and the visibility of the new installation is less than the existing installation.

(2) Secondary facade. The installation will not be more than minimally visible over a secondary facade. If it is not practicable or feasible to make the installation minimally visible, staff may approve an installation that is more than minimally visible, provided the visibility is not caused by the equipment being placed on an LPC-approved addition and the installation is seen only through a gap view between buildings, regardless of the presence of other rooftop installations of any type in the surrounding context. Such installations may include a required guardrail and/or a screen to conceal the equipment. If the installation is occurring within a scenic landmark, the visibility will be controlled by existing or new trees, plantings or other foliage. For purposes of this paragraph (2), "gap view" shall mean an opening in the streetwall no greater than 25 feet that allows visibility of secondary facades and rooftops from a public thoroughfare. A gap can be an empty lot, yard, alley, driveway, area way, garden or park, and can also be a building that is shorter than the adjacent building and allows views above it, including a garage or rear addition.

(3) Installation of Solar Panels. LPC Staff may approve the installation of solar panels on flat roofs and sloped roofs, and on other rooftop structures, as well as related framing and equipment, if the proposal meets the following relevant criteria:

(i) Installations on flat roofs.

(A) Solar panel installations on a flat roof, including flat or sloped arrays and arrays on elevated canopies, may be minimally visible over a primary or secondary facade if they have been located to minimize visibility to the greatest extent possible; and

(B) Solar panel installations on a flat roof, including flat or sloped arrays and arrays on elevated canopies, may be more than minimally visible over a secondary facade, if the installation is only seen through a gap view between buildings, even if there are no other rooftop installations of any type in the surrounding context. For purposes of this paragraph (3), a "gap view" shall mean an opening in the streetwall no greater than 25 feet that allows visibility of secondary facades and rooftops from a public thoroughfare. A gap can be an empty lot, yard, alley, driveway, area way, garden or park, and can also be a building that is shorter than the adjacent building and allows views above it, including a garage or rear addition; and

(C) Installations of fencing or guardrails on a flat roof, that are required as part of a solar panel installation, but not part of a more expansive application for work (e.g., constructing a new roof top deck), may be more than minimally visible over a primary or secondary facade if the staff determines that such installation does not detract from significant architectural features of the building or district, provided that:

1. Documentation is provided demonstrating that safety tie-back anchors have been deemed unacceptable under DOB and/or FDNY review and fencing or guardrails are required instead; and

2. The height and length of the required fencing or guardrail is the minimum required by law and is set back to the greatest extent permissible, and any adjustment to the solar panel arrays to facilitate a shorter height or length and/or a greater setback has been explored and executed if feasible; and

3. The design of the fencing or guardrail utilizes the fewest and thinnest members possible (e.g., bars or cables instead of pipes), and is finished in a neutral black or gray color; and

4. If the fencing or guardrail is more than minimally visible or will significantly interrupt an otherwise pristine roofline above the building and/or its row, the number of panels will be reduced to make the guardrail less visible.

(ii) Other rooftop installations. Solar panel installations on an existing pergola, bulkhead, or other rooftop structure that does not have a flat roof may be visible and may increase the overall visibility of the pergola, bulkhead or other rooftop structure if the staff determines that it does not detract from the building or the streetscape, provided that;

(A) the installation is parallel to the surface of the pergola, bulkhead or other rooftop structure that does not have a flat roof and is mounted as close to the surface as technically feasible; and

(B) the solar panels will be "black on black" with black edge framing and black PV surfacing that masks the grid of photovoltaic cells, or an alternative color that better relates to the appearance of the roofing it is installed on may be considered, if the installation is more than minimally visible from a public thoroughfare and the color will result in a more harmonious installation overall.

(iii) Sloped roof installations.

(A) Solar panel installations on a front-facing or side-facing slope of a roof, including at free-standing houses, rowhouses and semi-attached houses, and other building types with pitched roofs, but not on designed roofs, may be visible over a primary facade, if other locations are deemed infeasible due to the lack of sufficient sunlight as documented in the application materials. For purposes of this subparagraph (iii), the term "designed roof" shall mean a roof that is part of the composition of the building, such as a mansard roof, has a character-defining architectural feature, such as a spire, turret or cupola, and in some cases a dormer, or a crowning element seen in the round, such as a tower or dome. Staff may approve an installation if it meets all of the following relevant criteria:

1. the installation is discrete and limited in footprint, unless the slope of the roof is sufficiently shallow to render the number of panels indistinguishable as viewed from a public thoroughfare and/or a larger footprint would result in a less conspicuous installation;

2. the installation is parallel to the surface of the sloped roof and is mounted as close to the surface as technically feasible, and all mounting framework is concealed beneath the solar panels to the greatest extent possible;

3. the installation is subservient to more prominent rooftop features (e.g., dormers) as viewed from a public thoroughfare;

4. the solar panels are not installed on significant historic roofing materials (e.g., slate or clay tiles);

5. the installation will not detract from any significant architectural features of the facade(s) or roof(s); and

6. the building is not an individual landmark.

(B) Solar panel installations on a rear-facing slope or side-facing slope of a roof may be visible over a secondary facade, if the installation is parallel to the surface of the sloped roof and is mounted as close to the surface as technically feasible, and all mounting framework is concealed beneath the solar panels to the greatest extent possible. Solar panel installations that are not visible from a public throughfare may be mounted at an angle to increase performance.

(C) The solar panels must be organized in manner that results in a simple, rectilinear footprint, and avoids stepping or separation of panels, to the greatest extent possible, if the installation is visible from a public thoroughfare.

(D) The solar panels must be "black on black" with black edge framing and black PV surfacing that masks the grid of photovoltaic cells, or an alternative color that better relates to the appearance of the roofing it is installed on may be considered, if the installation is visible from a public thoroughfare.

(E) A black-finished "skirt", "critter guard" or other element must be installed at the base and/or sides of the solar panels if the installation is visible from a public thoroughfare and the addition of the skirt will improve the overall appearance of the installation.

(F) If the installation of the solar panels requires the removal of historic roofing material (e.g. slate or clay tiles), where allowed pursuant to these rules, the tiles must be retained and stored on site for future reuse.

(iv) Related equipment.

(A) The electrical conduit must be minimized in length to the greatest extent possible, and located at the least visible side of the roof and wall where possible, or otherwise placed in inconspicuous locations (e.g., adjacent to gutters and leaders, at inset joints of abutting walls, etc.), and must be painted to match the adjacent surfaces finishes if feasible, if the installation is visible from a public thoroughfare; and

(B) The inverter box must be located adjacent to the existing electrical meter where possible, or otherwise placed in an inconspicuous location, if the installation is visible from a public thoroughfare.

(h) Installation of HVAC Equipment and Mechanical Equipment in Yards and Areaways of Landmarks and Buildings in Historic Districts and Scenic Landmarks. LPC Staff will approve the installation of HVAC and mechanical equipment in the front, side or rear yard if the proposal meets the following relevant criteria:

(1) Primary facades. Installations fronting primary facades of individual landmarks and buildings in historic districts and scenic landmarks:

(i) There is no practical or feasible alternative to installing the equipment in front of the primary facade;

(ii) The installation of HVAC and other mechanical equipment, at grade or on platforms, will not be visible from a public thoroughfare, or will be minimally visible due to location and/or screening by architectural or hardscape features of the building (e.g., behind an areaway wall or within a below-grade light-well);

(iii) Any penetrations for associated conduits or ducts through the facade will be as small as possible in conformance with the manufacturer's recommended dimensions;

(iv) If there is any visibility of the installation from a public thoroughfare, the HVAC and other mechanical equipment, and associated platforms, will have a finish that matches the color of the underlying material, or is otherwise neutral so as to not call attention to itself; and

(v) The installation will not damage or remove a significant architectural feature of the building and, for buildings in historic districts and scenic landmarks, will not detract from the significant architectural features of adjacent buildings or significant landscape features.

(2) Secondary facades. Installations fronting secondary facades:

(i) The installation of HVAC and other mechanical equipment at grade or on platforms will be minimally visible to the greatest extent possible. For purposes of this subparagraph (i), visibility can be reduced or eliminated through the use of permanent plantings or the installation of a new fence or screen;

(ii) The installation is set back from the public thoroughfare to the greatest extent feasible;

(iii) Any penetrations for associated conduits or ducts through the facade will be as small as possible in conformance with the manufacturer's recommended dimensions;

(iv) If the installation is visible from a public thoroughfare, the HVAC and other mechanical equipment, and associated platforms, will have a finish that matches the color of the underlying material, or is otherwise neutral so as to not call attention to itself; and

(v) The installation will not damage or remove a significant architectural feature of the building and, for buildings in historic districts and scenic landmarks, detract from the significant architectural features of adjacent buildings or significant landscape features.

(Amended City Record 12/20/2018, eff. 1/19/2019; amended City Record 7/20/2023, eff. 8/19/2023)

§ 2-22. Fire Escapes

Open this section

(a) Removal of an Existing Fire Escape. LPC Staff will approve the removal of an existing fire escape if the proposal satisfies the following relevant criteria:

(1) The fire escape is not a significant protected feature of the building based on a finding that:

(i) The fire escape is not original to the building;

(ii) The fire escape does not have architectural merit in itself; and

(iii) The fire escape is not mentioned or otherwise called out as significant in the LPC designation report; or

(iv) The fire escape is not located on a building within a historic district in which fire escapes are identified as significant architectural features that contribute to the special architectural and historic character of the district.

(2) Damage to the facade caused by the installation, presence or removal of, or exposed by the removal of, the fire escape will be repaired to match the historic fabric; and

(3) Architectural elements removed, damaged or altered by the installation of the fire escape will be reinstalled, repaired or, if beyond repair, replaced or replicated.

(b) Alteration, Restoration and Maintenance of an Existing Fire Escape. LPC Staff will approve work on an existing fire escape if the proposal satisfies the following relevant criteria:

(1) Replacement of a fire escape drop ladder with a swing stair or a swing stair with a drop ladder matches the material, general details and color of the existing fire escape;

(2) Installation of a horizontal and/or vertical extension matches the material, details, color and dimensions of the existing fire escape, provided the installation will not conceal or damage any significant architectural features of the building; and

(3) Restoration and maintenance, including replacing any parts in kind with parts, match the existing fire escape in terms of material, details and color, or repainting of the existing color, a dark color such as black or brown that is typical of the historic district, or a color that matches or is similar in hue to the existing color of the facade.

(c) Installation of New Fire Escapes. LPC Staff will approve the installation of a new fire escape if the proposed work satisfies all of the following relevant criteria:

(1) Primary facade of a building in a historic district.

(i) Similar installations are commonly found on historic buildings in the district;

(ii) The fire escape is simple and utilitarian in design;

(iii) The installation will not cause the removal or, or damage to, any significant architectural features of the building;

(iv) The installation will not detract from the special historic and architectural character of the building or adjacent buildings;

(v) The fire escape cannot be located on a secondary facade; and

(vi) There is no feasible alternative to installing the fire escape. In making a determination that there is no feasible alternative, LPC Staff will consider whether the need for a fire escape on the primary facade is necessitated by recent or approved interior renovations.

(2) Visible secondary facade of a building in a historic district.

(i) The fire escape is simple and utilitarian in design;

(ii) The installation will not cause the removal or, or damage to, any significant architectural feature of the facade;

(iii) The installation will not detract from the special historic and architectural character of the building or adjacent buildings;

(iv) The fire escape cannot be located on a nonvisible secondary facade; and

(v) There is no feasible alternative to installing the fire escape. In making a determination that there is no feasible alternative, LPC Staff will consider whether the need for a fire escape on a visible secondary facade is necessitated by recent or approved interior renovations.

(3) Nonvisible secondary facade of any building.

(i) The fire escape is simple and utilitarian in design; and

(ii) The installation will not cause the removal of, or damage to, any significant architectural feature of the facade.

(Amended City Record 12/20/2018, eff. 1/19/2019)

§ 2-23. Rules Relating to Installation of Certain Types of Street Furniture, Sidewalk and Roadway Cafes and Other Installations in the Public Right-of-Way

Open this section

(a) Introduction. The provisions set forth below are intended to ensure that street furniture, sidewalk and roadway seating areas and other installations in the public right-of-way installed in areas under the jurisdiction of the Landmarks Preservation Commission are installed in a manner that does not damage or destroy historic fabric and that the design and placement of such furniture, seating areas and other installations does not call undue attention to themselves or detract from the significant architectural features of an improvement or a historic district or adversely affect a historic district’s distinct sense of place.

(b) Approval of Installation and Design of PPT Enclosure and of PCS Installation. Public pay telephones have been part of the city’s streetscape for half a century. First introduced in the 1950s pursuant to a franchise agreement with the city, legally permitted public pay telephones contribute to the urban experience as well as provide an important communication link for business, pleasure and public health and safety. Public pay telephones have traditionally had a quiet presence on the streetscape that allowed for their identification without calling undue attention to themselves.

(1) Definitions. As used in this section, the following terms have the following meanings:

Curbfront. The term “curbfront” means the sidewalk curb that divides the sidewalk from the roadway.

PCS Franchise Agreement. The terms “PCS Franchise Agreement” means a valid franchise granted by the City Department of Information Technology and Telecommunications (“DoITT”) to provide public pay telephone and wireless internet service on the inalienable property of the City of New York.

PPT Enclosure. The term “PPT Enclosure” means any associated housing or enclosure that partially or fully surrounds a PPT, and including an associated pedestal, which has been approved by the Art Commission.

PPT Franchise Agreement. The term “PPT Franchise Agreement” means a franchise granted by the City pursuant to the revised solicitation issued by the Department of Information Technology and Telecommunications (“DoITT”) on June 9, 1997 pursuant to Resolution No. 2248 or any subsequent solicitation with a similar purpose whether or not such subsequent solicitation includes all or part of the components of the June 9, 1997 solicitation.

Public communications structure or PCS. The term “public communications structure” or “PCS” means a structure installed on public property pursuant to a valid PCS Franchise Agreement.

Public pay telephone or PPT. The term “public pay telephone” or “PPT” is defined by § 23-401(f) of the Administrative Code of the City of New York.

(2) PPT Enclosure and Installation. No application to the Commission, and no certificate, approval, permit or report shall be required for a proposal to install a PPT Enclosure if such proposal meets the following criteria:

(i) The PPT Enclosure is proposed to be installed no farther than 24 inches from and no closer than 18 inches to the curbfront in an area zoned for commercial or manufacturing uses pursuant to the New York City Zoning Resolution;

(ii) Each PPT Enclosure shall be designed to be inconspicuous and to not call undue attention to itself, and shall have an exterior dimension no greater than 35” wide x 44” long x 90” high. A maximum of two PPTs may be installed in-line together, but in such instance the enclosure shall be no greater than 35” wide x 88” long x 90” high. The height limitation shall include the height of a mast if one is installed. The PPT Enclosure may have clear glazing panels and shall be rectilinear if the PPT Enclosure is designed to have advertising panels;

(iii) The PPT Enclosure shall not be installed in or on, or in the mortar joints between, bluestone, granite, slate or brick paving material, nor shall such paving material be disturbed in any manner in connection with the installation of the PPT;

(iv) The PPT Enclosure shall not be installed in front of an improvement designated as a landmark;

(v) The telephone and power lines to and from such PPT Enclosure, or any conduit containing such lines, shall not be visible;

(vi) The nonglazed portion of the PPT Enclosure shall be a dark brown, dark green, black or dark grey color, or is uncolored stainless steel or clear-finished aluminum. If the PPT Enclosure is less than 15 inches by 36 inches, all portions of the PPT Enclosure shall be stainless steel or clear-finished aluminum;

(vii) If the PPT Enclosure has advertising panels, the advertising panels shall be limited to two side panels, each of which is not larger than 27” wide x 57” high. There shall be no advertising panel on the rear of the PPT Enclosure facing the street. The advertising panels shall not be illuminated in any fashion. Advertising shall be limited solely to the PPT Enclosure. No advertising shall be permitted on a PPT Enclosure that is smaller than 27” wide x 57” high. No PPT Enclosure shall have any light emitting diode (L.E.D.) lettering, design or advertising. In addition to the above, a PPT Enclosure may identify the name or logo of the owner of the PPT and the fact that it is a public telephone. Where such identification is illuminated, it shall be illuminated internally from behind the lens, be limited to the top two inches of the PPT Enclosure, and may occur on all sides of the PPT Enclosure; and

(viii) The proposed PPT installation meets all applicable terms, conditions and requirements of the PPT Franchise Agreement, and all applicable distance, clearance and other siting requirements set forth in Title 67 of the Rules of the City of New York.

(3) PCS Installation. No application to the Commission, and no certificate, approval, permit or report shall be required for installation of a PCS if:

(i) The PCS is to be installed in accordance with the siting criteria described in the applicable PCS Franchise Agreement and in an area zoned for commercial or manufacturing uses pursuant to the New York City Zoning Resolution, or, if the PCS does not include advertising, in an area zoned for residential use, except that:

(A) in addition to the siting criteria in the applicable PCS Franchise Agreement, if the PCS is to be installed in an area zoned for commercial or manufacturing use and the installation would replace an existing PPT Enclosure, the proposed installation shall not be within 100 linear feet on the same blockfront of another PCS structure or PPT Enclosure; and

(B) if the PCS is to be installed in an area zoned exclusively for residential use the installation is to replace an existing PPT Enclosure. No new installation of a PCS in an area zoned exclusively for residential use shall be covered by this rule;

(ii) No more than one PCS shall be installed at the same location;

(iii) If the PCS has advertising panels, the advertising panels are limited to two side panels, each of which is not larger than 27” by 47.5”. There shall be no advertising panel on the rear of the PCS facing the street. Static digital advertising shall be permitted in commercial or manufacturing districts. For purposes of this rule, “static digital” shall mean advertising in which a series of fixed digital images are displayed electronically, and each fixed image must be displayed for a minimum of 15 seconds and fade in and fade out no faster than 1 second;

(iv) The PCS conforms to the design and materials that have been approved by the New York City Art Commission, also known as the Public Design Commission, and has an exterior dimension no greater than 11” wide x 35” deep x 122.9” high;

(v) The PCS shall not be installed in or on, or in the mortar joints between, bluestone, granite, slate or brick paving material, nor shall such paving material be disturbed in any manner in connection with the installation of the PCS;

(vi) The PCS is not installed in front of an improvement designated as an individual landmark, unless the PCS is replacing an existing public pay telephone that was previously operated pursuant to a valid franchise agreement with DoITT; and

(vii) The telephone and power lines to and from such PCS, or any conduit containing such lines, are not visible.

(4) Other Proposals.

(i) All proposals to install a PPT Enclosure or a PCS that do not satisfy the requirements of paragraphs (2) or (3) of this subdivision shall be reviewed and approved by the Landmarks Preservation Commission by a certificate of appropriateness, report, permit for minor work or certificate of no effect, as appropriate, as set forth below.

(ii) Application Procedures for Proposals to Install a PPT Enclosure or PCS Requiring a Certificate, Permit or Report. An application form shall be filed for each proposed PPT Enclosure or PCS. Notwithstanding the requirements of 63 RCNY § 2-01, the application form for the installation of a PPT Enclosure or PCS shall be signed by the person who owns the PPT or PCS or the agent or principal of such person, or any other person authorized to apply for a permit to install a PPT or PCS pursuant to the relevant franchise agreement or Title 67 of the Rules of the City of New York. No advertising shall be permitted on a PPT, PPT Enclosure, or PCS that is not located at the curb.

(5) Nothing in this rule shall be interpreted to obviate the need to obtain all necessary approvals from the Department of Information Technology and Telecommunications, or any other governmental agency, for all installations of a PPT Enclosure or a PCS.

(c) Review of Roadway and Sidewalk Cafes and Components.

(1) Introduction. Sidewalk cafes associated with ground floor restaurants have been part of the city’s streetscape since the mid-19th century, and legally so since 1929. These installations support ground floor restaurants and enliven the commercial streetscape. Due to their low-scale and lightweight components (e.g. dining furniture, umbrellas, and perimeter elements like ropes, stanchions and planters), sidewalk cafes have traditionally had a simple presence on the streetscape and do not detract from the buildings they are associated with and the streetscape in general. Because their components are moveable, the LPC has historically not regulated their presence except where components are not moveable. In response to the COVID pandemic of 2020-2022, the City allowed, on an emergency basis, roadways adjacent to the curb to be used as additional outdoor dining spaces for ground floor restaurants. The provisions for roadway dining were made permanent through local legislation in 2023. Like sidewalk cafes, the regulations for the physical set-up of roadway cafes adopted by the Department of Transportation (“DOT”) mandate easily removable components, including perimeter enclosures, tables and chairs. In addition, they can only operate between April 1 and November 29 and must be removed altogether when not permitted. The provisions set forth below are intended to ensure that roadway and sidewalk cafes installed in locations under the jurisdiction of the Landmarks Preservation Commission have a modest and ephemeral presence and are installed so as not to damage or destroy historic fabric, and that the components and overall composition of these installations do not call undue attention to themselves or detract from the significant architectural features of an improvement or a historic district.

(2) Definitions. As used in this 63 RCNY § 2-23, the following terms have the following meanings:

Components. The term “Components” means the physical objects used to define the area in which the roadway or sidewalk cafe seating area will be located, such as solid barriers, planters, stanchions and rope, and low partitions, as well as tables, chairs and umbrellas inside such area(s).

Enclosed Sidewalk Cafe. The term “Enclosed Sidewalk Cafe” means a structure housing a seating area that is entirely enclosed on the sides and top, creating an interior space that connects to the ground floor restaurant and is located on the sidewalk.

Physically Attached. The term “physically attached” means attached mechanically, for example by bolt, screw or nail, or chemically, for example, by glue or other adhesive.

Roadway Cafe. The term “Roadway Cafe” means an open-air portion of a ground floor restaurant containing readily removable tables, chairs, and other removable decorative items, which is located in the curb lane or parking lane of a roadway fronting the restaurant, and where the components comply with applicable DOT rules for such installations, including siting, design, signage and seasonal duration requirements.

Sidewalk Cafe. The term “Sidewalk Cafe” means an open-air portion of a ground floor restaurant containing only readily removable components, such as tables, chairs, stanchions and rope, planters and other removable and/or decorative items, that is located on a public sidewalk or sidewalk widening in front of the restaurant, and where the components comply with applicable DOT rules for such installations.

(3) Installation and Design of Sidewalk Cafes. Except as indicated in subdivision (5) of this section, no application to the Commission, and no certificate, permit, report or approval is required for installation of a sidewalk cafe where the installation complies with all requirements of 34 RCNY Chapter 5, governing Licenses and Revocable Consents for Sidewalk and Roadway Cafes, including but not limited to siting, design, and advertising requirements for such installations.

(i) Enclosed sidewalk cafes, including alterations to or replacement of existing installations, are not covered by this rule.

(4) Installation and Design of Roadway Cafes. Except as indicated in paragraph (5) of this subdivision, no application to the Commission, and no certificate, permit, report or approval is required for installation of a roadway cafe where the installation complies with all requirements of 34 RCNY Chapter 5, governing Licenses and Revocable Consents for Sidewalk and Roadway Cafes, including but not limited to siting, design, advertising and seasonal duration requirements for such installations.

(5) Notwithstanding the provisions of paragraphs (3) and (4) of this subdivision, if a sidewalk or roadway cafe includes the installation of a component, including but not limited to an awning, overhead covering, heat lamp, light fixture or electrical or plumbing conduit, that is:

(i) physically attached to a building, or

(ii) penetrates through the exterior of a building (for example, through a facade or storefront), or

(iii) through such attachment physically impacts an interior landmark, or

(iv) attaches to or penetrates through a bluestone or granite paver or cast iron vault light panel, the owner must submit an application for such component(s) to the LPC and must not install such component(s) until the LPC has issued a certificate, permit, report or other approval for such installation.

(6) Other Proposals.

(i) All proposals to install a sidewalk or roadway cafe that do not satisfy the requirements of paragraphs (3) or (4) of this subdivision must be reviewed and approved by the Landmarks Preservation Commission by a certificate of appropriateness, certificate of no effect, permit for minor work or report, as appropriate, as set forth below.

(ii) Application Procedures for Proposals to Install a Sidewalk or Roadway Cafe Requiring a Certificate, Permit or Report. An application form must be filed for each proposed sidewalk or roadway cafe. The application form must be signed by the owner of the real property which contains the ground floor restaurant in front of which the sidewalk or roadway cafe is to be installed.

(iii) Nothing in this rule shall be interpreted to obviate the need to obtain all necessary approvals from the Department of Transportation, Department of Buildings or any other governmental agency, for installations of a sidewalk or roadway cafe or any component within such cafe.

(d) Bus Shelters.

(1) Introduction. New York City has had many systems of public transportation, including trolleys, elevated trains, subways, and bus service. Designated stops were an integral part of these public transportation systems. In 2006, the City awarded a city-wide non-exclusive franchise which provides the right and consent to install, operate and maintain bus shelters throughout the five boroughs.

(2) Definitions.

Bus Shelter. The term “Bus Shelter” means structures intended as bus stop shelters (including seating, if installed) which provide meaningful protection from precipitation, wind, and sun.

Bus Stop. The term “Bus Stop” means a stop on a bus route, designated by the MTA and, thereafter, managed by the New York City Department of Transportation.

Coordinated Street Furniture Franchise (CSFF). The terms “Coordinated Street Furniture Franchise” and “CSFF” mean the operative franchise granted by the City of New York which provides the right and consent to install, operate and maintain Bus Shelters throughout the City of New York.

Department of Transportation (DOT). The terms “Department of Transportation” and “DOT” refer to the New York City Department of Transportation, an agency of the City of New York.

Franchisee. The term “Franchisee” means the franchisee of the CSFF.

Historic Paving. The term “Historic Paving” means granite, bluestone, or brick paving, as defined and regulated in 63 RCNY § 2-19.

Landmarks Preservation Commission (LPC). The terms “Landmarks Preservation Commission” and “LPC” refer to the Landmarks Preservation Commission, a commission of the City of New York.

LPC Rules. The term “LPC Rules” means the rules of the Landmarks Preservation Commission as promulgated and codified at Title 63 of the Rules of the City of New York.

New York State Metropolitan Transportation Authority (MTA). The terms “New York State Metropolitan Transportation Authority” and “MTA” refer to the Metropolitan Transportation Authority.

(3) Installation of a Bus Shelter. Except as indicated in this paragraph and in paragraph (4) of this subdivision, no application to the Landmarks Preservation Commission, and no certificate, permit, report, or approval is required for installation of a Bus Shelter where:

(i) the Bus Shelter complies with the design, dimensional and material specifications approved by the Public Design Commission, or its predecessor the Art Commission, including the number, size, and placement of advertising panels;

(ii) the Bus Shelter is to be installed and operated at a Bus Stop in compliance with all requirements of DOT and the CSFF, including all siting and clearance criteria, except that a Bus Shelter proposed to be installed on Historic Paving requires an approval from the LPC pursuant to subdivision (4); and

(iii) Removal of a Bus Shelter. The Franchisee must remove a Bus Shelter if DOT determines that the Bus Shelter is no longer required at a Bus Stop or if DOT orders its removal. Upon removal of a Bus Shelter, the Franchisee must restore the site to the condition prior to the installation of the Bus Shelter, or, with respect to installations on Historic Paving, must restore the site in accordance with an LPC approval issued pursuant to paragraph (4).

(4) Other Proposals.

(i) All proposals to install a Bus Shelter that do not satisfy the requirements of paragraph (3) of this subdivision must be reviewed and approved by the Landmarks Preservation Commission by a certificate of appropriateness, certificate of no effect, or permit for minor work or report, as appropriate, as set forth below.

(ii) Application Procedures for Proposals to Install a Bus Shelter Requiring a Certificate, Permit or Report pursuant to this paragraph. An application form(s) must be filed for proposed Bus Shelters. The application form must be signed by DOT as owner and the Franchisee as applicant. In reviewing an application to install a Bus Shelter on Historic Paving, LPC staff will seek to the greatest extent feasible to preserve and reuse the existing Historic Paving but may allow the applicant to modify or replace the Historic Paving in kind where there is no feasible alternative to allow the installation of a Bus Shelter. If the LPC staff approves the modification or replacement of the Historic Paving in connection with the installation of a Bus Shelter, upon removal of the Bus Shelter the applicant must restore the paving to the condition prior to the modification or replacement of the Historic Paving.

(iii) Nothing in this section shall be interpreted to obviate the need to obtain all necessary governmental approvals applicable to the installation of a Bus Shelter, including but not limited to any required DOT approvals.

(Amended City Record 7/12/2016, eff. 8/11/2016; amended City Record 12/20/2018, eff. 1/19/2019; amended City Record 5/24/2024, eff. 6/23/2024; amended City Record 6/26/2024, eff. 7/26/2024)

§ 2-31. Definitions

Open this section

As used in these Rules, the following terms have the following meanings:

Architect. "Architect" means an individual, partnership, corporation or other legal entity licensed to practice the profession of architecture under the education law of the State of New York.

CNE. "CNE" means a Certificate of No Effect as defined by § 25-306 of the Landmarks Law.

Day. "Day" means any day other than a Saturday or Sunday or legal holiday.

Engineer. "Engineer" means any individual, partnership, corporation or other legal entity licensed to practice the profession of engineering under the education law of the State of New York.

Landmarks Law. "Landmarks Law" refers to Section 3020 of the Charter and Chapter 3 of Title 25 of the Administrative Code of the City of New York.

Landmarks Preservation Commission. "Landmarks Preservation Commission" means the Commission acting in its agency capacity to implement the Landmarks Law.

LPC staff. "LPC Staff" means the staff of the Landmarks Preservation Commission acting in the Commission's agency capacity.

Summons. "Summons" means a notice from the Landmarks Preservation Commission that work on a landmark site or within an historic district was performed without a permit or was not performed in accordance with a permit issued by the Landmarks Preservation Commission. With respect to Title 63 of the Rules of the City of New York and §§ 25-301 through 25-322 of the Administrative Code, the term "Summons" will be construed to include and apply to any previously issued "Notice of Violation."

Story. "Story" is defined as a habitable floor level, including a basement but not including a cellar.

Terms not otherwise defined in these rules have the meaning given them in the Landmarks Law.

(Amended City Record 12/20/2018, eff. 1/19/2019)

§ 2-32. Expedited Review Procedures

Open this section

(a) General. The expedited review procedures set forth in this section are available for certain interior work as detailed below. Expedited review is predicated upon the statements and representations of the architect or engineer and the owner and upon the satisfaction of certain terms and conditions, all as set forth in this section.

(b) Work Eligible for Expedited Review. The following work is eligible for expedited review:

(1) Interior work which is to be performed at or above the third full story and which does not involve any change to, replacement of, or penetration of, an exterior wall, window, skylight or roof, including but not limited to penetrations, replacements or changes for ducts, grilles, exhaust intakes, vents or pipes, may qualify for an expedited review;

(2) Interior work which is to be performed at or below the second full story in a building where there is no commercial use below the second full story, where the proposed work does not involve change to, replacement of, or penetration of an exterior wall, window, skylight or roof, including but not limited to penetrations, replacements or changes for ducts, grilles, exhaust intakes, vents or pipes;

(3) Interior work which is to be performed in the cellar or basement, provided the work does not require excavation, except for minimal excavation related to elevator or mechanical work that does not require underpinning, and the work does not involve any change to, replacement of, or penetration of, a visible exterior wall or window;

(4) Expedited review will not be permitted for work proposed to be performed within a designated Interior Landmark.

(c) Criteria and Conditions for Expedited Review. Each of the following conditions must be satisfied in order to obtain an expedited review:

(1) The work will be eligible work as described in 63 RCNY § 2-32(b) above.

(2) The application for which an expedited review is requested will be accompanied by a completed Landmarks Preservation Commission expedited review form which must include:

(i) a statement signed and sealed by the architect or engineer that:

(A) the architect or engineer has prepared, or supervised the preparation of, the plans and specifications submitted with the application;

(B) all work shown on such plans and specifications is:

(a) interior work only,

(b) to be performed only at or above the third full story or in the cellar or basement, or at or below the second full story in a building where there is no commercial use on the ground floor,

(c) not to be performed on any portion of a space designated as an Interior Landmark,

(d) does not involve excavation, except for minimal excavation related to elevator or mechanical work, or any change to, replacement of, or penetration of, a window, skylight, exterior wall or roof or any portion thereof, and

(e) for floors one through six (1 - 6) does not involve a dropped ceiling greater than one foot (1'0") below the head of a window, a perpendicular partition abutting a window, or a parallel partition blocking more than one foot (1'0") of a window, any of which is less than a minimum of one foot (1'-0") back from interior window sill or frame, whichever is further from the glass.

(C) that where there are associate architects or engineers, that they likewise join in the request for an expedited review of the application;

(D) that the architect or engineer and associate architects or engineers, if any, are aware that the Landmarks Preservation Commission will rely upon the truth and accuracy of the statements contained in the application made by them, and any amendments submitted in connection therewith, as to compliance with the provisions of the Landmarks Law and these rules;

(ii) a statement signed by the owner of the property that:

(A) the proposed work meets the criteria for expedited review as described in subdivision (b);

(B) no change to, or modification of, the proposed work will be undertaken by the owner, his or her architect or engineer or any other agent of the owner without the prior approval of the Landmarks Preservation Commission; and

(C) the necessary remedial measures to obtain compliance will be taken, if the same becomes necessary;

(3) No Summons from the Landmarks Preservation Commission is in effect against the property which is the subject of the proposed work for which an expedited review is requested; and

(4) The application is complete in all other respects.

(5) The architect or engineer and associate architects or engineers, if applicable, have not been excluded by:

(i) the Chair of the Landmarks Preservation Commission from the procedures for expedited review pursuant to 63 RCNY § 2-34; or

(ii) the Commissioner of the Department of Buildings from the Department's procedures for limited supervisory check of applications and plans set forth in 1 RCNY § 21-02.

(d) Issuance of Permit or Report. If all conditions to an expedited review have been satisfied, LPC Staff will:

(1) issue a CNE or a report to the applicant within five business days of receipt of a complete application; and

(2) perforate all drawings accompanying such application to indicate approval thereof.

(Amended City Record 12/20/2018, eff. 1/19/2019; amended City Record 7/20/2023, eff. 8/19/2023)

§ 2-33. Effect of Failure to Meet Conditions for an Expedited Review

Open this section

The Landmarks Preservation Commission shall notify any applicant who has requested an expedited review of his or her application under these rules of the reason for their failure to satisfy the conditions for expedited review.

§ 2-34. Remedies for False Statements and Procedures for Action

Open this section

(a) Grounds for action.

(1) The Chair of the Landmarks Preservation Commission may exclude any architect or engineer from the procedures for expedited review of applications if the Chair of the Landmarks Preservation Commission finds that:

(i) In connection with the Landmarks Preservation Commission expedited review form described in 63 RCNY § 2-32(c)(1) the architect or engineer has:

(A) knowingly or negligently made any false or misleading statement; or

(B) knowingly or negligently omitted a statement or failed to state a material fact; or

(C) knowingly or negligently falsified or allowed to be falsified any fact; or

(D) willfully induced another person to do any of the above; or

(ii) A Summons, a previously issued Notice of Violation, or "Notice to Stop Work" has been issued by the Landmarks Preservation Commission against work performed pursuant to any plans, prepared by or under the supervision of such architect or engineer, and such architect or engineer knew, or had reason to know, that the work performed pursuant to such application, plan, certification, or report was not carried out in accordance with approved plans or exceeded the scope of such approved plans and such architect or engineer failed to act to stop such work and/or correct such work.

(2) The powers, rights and remedies of the Landmarks Preservation Commission set forth in this 63 RCNY § 2-34(a) are non-exclusive and will not be deemed to limit or supersede any other power, right or remedy of the Landmarks Preservation Commission.

(b) Procedures.

(1) Written notice of a preliminary determination, together with the basis for such action to exclude from expedited review must be served on the Architect or Engineer of record pursuant to the provisions of New York State Civil Practice Law and Rules § 308.

(2) The Architect or Engineer notified under 63 RCNY § 2-34(b)(1) will be entitled to, and scheduled for, a hearing on the preliminary determination in accordance with 63 RCNY § 2-34(c) if written objection to the preliminary determination and the grounds for such objection are submitted to the Chair of the Landmarks Preservation Commission within fifteen (15) days after the date that the notice of preliminary determination is served.

(3) If no hearing is requested pursuant to 63 RCNY § 2-34(b)(2) above, the preliminary determination of the Chair of the Landmarks Preservation Commission will be deemed confirmed and will become final and effective on the sixteenth 16th day after the preliminary notice of determination is served.

(4) If after a hearing in accordance with 63 RCNY § 2-34(c), the Chair of the Landmarks Preservation Commission confirms the preliminary determination, the Chair must notify the Architect or Engineer of such decision and such notice must include a written statement indicating the reason for his or her determination.

(5) On or after the effective date of the final determination to exclude an Architect or Engineer from participation in expedited review procedures all of the plans prepared by or under the supervision of such Architect or Engineer must be subject to full review by the Landmarks Preservation Commission.

(c) Hearing.

(1) Any hearing described in 63 RCNY § 2-34(b)(2) will be held at, and conducted by the Office of Administrative Trials and Hearings in accordance with their rules and procedures.

(2) The Architect or Engineer may be represented by counsel and may present evidence in his or her behalf. A transcribed or tape-recorded record must be kept of the hearing.

(3) The Chair of the Landmarks Preservation Commission must notify the respondent of the final determination within ten (10) days after the receipt of the findings of fact from the Office of Administrative Trials and Hearings on such matters. The determination of the Landmarks Preservation Commission must be supported by substantial evidence.

(d) Review of Determination. At the expiration of two (2) years from the date of the initial determination to exclude an Architect or Engineer from participation in the procedures for expedited review of applications, and at intervals of no more than six months thereafter, upon request of the Architect or Engineer, the Chair of the Landmarks Preservation Commission must reexamine such determination. If the Architect or Engineer has not committed any of the acts described in clause (2) of 63 RCNY § 2-34(a) above during such period, the Chair of the Landmarks Preservation Commission may rescind such determination.

(Amended City Record 12/20/2018, eff. 1/19/2019)

§ 2-35. Miscellaneous. [Repealed]

Open this section