NYC Administrative Code Title 28, Chapter 12 The New York City Existing Building Code (effective July 17, 2027), part 1 of 5
§ 28-1201.1 to Section EBC 501: 38 sections.
§ 28-1201.1. Update
No later than the third year after the effective date of this section and every third year thereafter, the commissioner shall submit to the city council proposed amendments that such commissioner determines should be made to this code to bring it up to date with the latest edition of the International Existing Building Code or otherwise modify the provisions thereof. In addition, prior to the submission of such proposal to the city council, such proposal shall be submitted to an advisory committee established by the commissioner pursuant to this title for review and comment.
(L.L. 2026/033, 1/17/2026, eff. 7/17/2027)
Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2026/033.
§ 28-1201.2. Enactment of the New York city existing building code
The New York city existing building code based on the 2015 edition of the International Existing Building Code published by the International Code Council, with changes that reflect the unique character of the city, is hereby adopted to read as follows:
(L.L. 2026/033, 1/17/2026, eff. 7/17/2027)
Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2026/033.
Section EBC 101. General
101.1 Title.
This code shall be known and may be cited as the “New York City Existing Building Code,” “NYCEBC” or “EBC.” All section numbers in this code shall be deemed to be preceded by the designation “EBC.”
101.2 Scope.
The provisions of this code shall apply to the repair, alteration, change of occupancy, addition to and relocation of existing buildings.
101.3 Intent.
The intent of this code is to provide minimum standards to safeguard life or limb, health, property, public welfare and the environment insofar as they are affected by the repair, alteration, change of occupancy, addition and relocation of existing buildings. Refer to Chapter 1 of Title 28 of the Administrative Code .
101.4 Applicability.
In accordance with Section 101.2, this code shall apply to the repair, alteration, change of occupancy, addition to and relocation of existing buildings as described in Sections 101.4.1 and 101.4.2.
101.4.1 Buildings not previously occupied.
A building or portion of a building that has not been previously occupied or used for its intended purpose in accordance with the laws in existence at the time of its completion shall be permitted to comply with the provisions of the laws in existence on the date of issuance of the original permit for the construction of the building or portion of the building unless such permit has expired pursuant to Section 28-105.9 of the Administrative Code .
101.4.2 Buildings previously occupied.
The legal occupancy of any existing building or structure, including the use of any service equipment therein, shall be permitted to continue without change, unless a retroactive change is specifically required by Section 119 of this code, Chapter 3 of Title 28 of the Administrative Code, or other applicable laws and rules or as deemed necessary by the commissioner for the general safety and welfare of the occupants and the public.
101.4.2.1 Compliance of prior code buildings with the applicable retroactive requirements of the 1968 building code.
In addition to the retroactive requirements described in Section 101.4.2, prior code buildings must comply with the applicable retroactive requirements of the 1968 building code and prior codes, including those requiring the installation of fire safety and building safety systems and the filing of reports verifying compliance of such installations by the specified dates. A violation of such provisions shall be a violation of this code.
101.4.2.2 Change in use or occupancy.
Changes in the use or occupancy of any existing building shall comply with Chapter 10. Any changes made in the use or occupancy of a building or structure not in compliance with this code shall be prohibited and shall be a violation of this code. After a change in use or occupancy has been made in a building, the re-establishment of a prior use or occupancy that would not be lawful in a new building of the same construction class shall be prohibited unless and until all the applicable provisions of this code and other applicable laws and rules for such reestablished use or occupancy shall have been complied with. A change from a use prohibited by the provisions of this code or other applicable codes, laws and regulations, but which was permitted under prior codes, to another use prohibited by the provisions of this code shall be deemed a violation of this code.
101.4.2.3 Alteration of existing buildings.
Alteration of existing buildings shall comply with Chapters 5 through 15, as applicable. Alteration of multiple dwellings, including conversion of prior code buildings to multiple dwellings, shall also comply with Appendix D.
101.4.2.4 Continuation of unlawful use or occupancy.
The continuation of the unlawful use or occupancy of a building or structure contrary to the provisions of this code, or contrary to the provisions of prior codes or other applicable law or rule, shall be a violation of this code.
101.5 Administration and enforcement.
Except as otherwise limited by the commissioner, administration and enforcement actions shall be in accordance with this code and the Administrative Code, including but not limited to approval of construction documents, issuance of permits and certificates of occupancy, tests and inspections, penalties and enforcement.
101.6 Safeguards during construction.
Construction work covered in this code, including any related demolition, shall be governed by Chapter 33 of the New York City Building Code and the requirements of Chapter 15 of this code.
101.7 Encroachments into the public right of way.
Encroachments into the public right of way shall be governed by Chapter 32 of the New York City Building Code .
101.8 Appendices.
The appendices referenced in this code shall be considered part of the requirements of this code to the prescribed extent of each such reference.
Section EBC 102. Applicability
102.1 General.
Where, in any specific case, different sections of this code specify different materials, methods of construction or other requirements, the most restrictive shall govern. Where a general requirement conflicts with a specific requirement, the specific requirement shall govern. Where British and metric units of measurement conflict, the British units shall govern.
102.2 Other laws.
The provisions of this code do not presumptively provide for matters that are contained in the Charter, the labor law, the multiple dwelling law, the zoning resolution, or the general city law. Where there is conflict or inconsistency between the requirements of this code and other applicable laws and rules, unless otherwise required, such conflict shall be resolved in favor of the more restrictive requirement.
102.3 Application of references.
References to chapter or section numbers or to provisions not specifically identified by number shall be construed to refer to such chapter, section, or provision of this code.
102.4 Referenced codes, standards and other laws and regulations.
The codes and standards referenced in this code shall be considered part of the requirements of this code to the prescribed extent of each such reference and as further described in Sections 102.4.1 through 102.4.4.
102.4.1 Referenced codes.
The referenced codes include the Administrative Code, New York City Building Code, New York City Electrical Code, New York City Fuel Gas Code, New York City Mechanical Code, New York City Plumbing Code, New York City Fire Code and New York City Energy Conservation Code .
102.4.2 Other laws and regulations.
Other laws and regulations that may be referenced in this code including codes, rules and regulations of New York city, New York state or Federal agencies.
102.4.3 Referenced standards.
The standards referenced in this code and in the rules of the department shall be considered part of the requirements of this code to the prescribed extent of each such reference. Refer to Article 103 of Chapter 1 of Title 28 of the Administrative Code for additional provisions relating to referenced standards.
102.4.3.1 Editions of referenced standards.
References to standards in this code shall be to the editions of those standards provided for in Chapter 16, or as otherwise provided by rule.
102.4.4 Conflicts.
Where conflicts occur between provisions of this code and referenced codes and standards, the provisions of this code shall apply.
Exception: Where an appliance or equipment is listed, as such term is defined in Section 28-101.5 of the Administrative Code, and enforcement of a code provision would violate the conditions of the listing of the equipment or appliance, the conditions of the listing shall govern.
102.5 Partial invalidity.
In the event that any part or provision of this code is held to be illegal or void, this shall not have the effect of making void or illegal any of the other parts or provisions.
102.6 Fire districts maps.
The boundaries of fire districts shall be in accordance with the maps set forth in Appendix D of the New York City Building Code .
Section EBC 103. Department of Buildings
103.1 General.
Refer to the Charter and Chapter 1 of Title 28 of the Administrative Code .
Section EBC 104. Duties and Powers of Commissioner of Buildings
104.1 General.
The commissioner shall have the authority to render interpretations of this code and to adopt rules, policies and procedures in order to clarify and implement its provisions. Such interpretations, policies, procedures, and rules shall be in compliance with the intent and purpose of this code. See the Charter and Chapter 1 of Title 28 of the Administrative Code for additional provisions relating to the authority of the commissioner of buildings.
Section EBC 105. Permits and Work Without a Permit
105.1 General.
Permits shall comply with this section and with Article 105 of Chapter 1 of Title 28 of the Administrative Code .
105.2 Required.
Except as otherwise provided in Section 105.3, any owner or owner’s authorized agent who intends to repair, add to, alter, relocate, demolish, or change the occupancy of a building or to repair, install, add, alter, remove, convert, or replace any electrical, gas, mechanical, or plumbing system, the installation of which is regulated by this code, or to cause any such work to be performed, shall first make application to the department for construction document approval in accordance with Chapter 1 of Title 28 of the Administrative Code and this chapter and obtain the required permit.
105.3 Work exempt from permit.
Exemptions from permit requirements of this code and as authorized in Chapter 1 of Title 28 of the Administrative Code and the rules of the department shall not be deemed to grant authorization for any work to be done in any manner in violation of the provisions of this code or any other laws or rules. Permits shall not be required for the following:
1. Work exempt from permit as listed in Section 28-105.4 of the Administrative Code and rules of the department.
2. Minor alterations and ordinary repairs as described in Section 105.3.1 of this code.
3. Ordinary plumbing work as described in Section 105.3.1 of this code.
105.3.1 Minor alterations, ordinary repairs and ordinary plumbing work.
A permit shall not be required for minor alterations, ordinary repairs and ordinary plumbing work, as such terms are defined in Section 202.
105.3.1.1 Work not constituting minor alterations or ordinary repairs.
Minor alterations or ordinary repairs shall not include:
1. The removal or cutting away of any load bearing or required fire-rated wall, fire door, floor or roof construction, or any portion thereof;
2. The removal, cutting or modification of any beams or structural supports;
3. The removal, change or closing of any required exit;
4. The addition, rearrangement, relocation, removal or replacement of any parts of the building affecting loading or exit requirements, or light, heat, ventilation, or elevator requirements or accessibility requirements, or any fire suppression or fire protection system;
5. Additions to, alterations of, or rearrangement, relocation, replacement, repair or removal of any portion of a standpipe or sprinkler system, water distribution system, house sewer, private sewer, or drainage system, including leaders, or any soil, waste or vent pipe, or any gas distribution system;
6. The alteration or repair of a sign for which a permit is required; or
7. Any other work affecting health or the fire or structural safety of the building or the safe use and operation of the service equipment therein.
105.3.1.2 Ordinary plumbing work.
Ordinary plumbing work is not required to be performed with a permit, provided that the licensed plumber performs such work in accordance with this code and all applicable laws and rules
105.3.1.2.1 Documentation of ordinary plumbing work.
The licensed plumber shall record the block, lot and address of each job, a description of the work performed at each address, and the location in each building where the ordinary plumbing work was performed. The licensed master plumber shall furnish a copy of such record to the building owner upon the completion of work. The licensed master plumber shall submit a report of completed ordinary plumbing work items in accordance with the requirements of the department.
105.3.1.2.2 Category 1 ordinary plumbing work.
Category 1 ordinary plumbing work shall be performed in accordance with this code and shall be limited to the following items:
1. The relocation of up to two plumbing fixtures within the same room to a maximum of 10 feet (3048 mm) distant from the original location, and the replacement or alteration of related supply, waste, and vent piping associated with the fixture relocation, except in health care facilities.
2. The installation, replacement or repair of a food waste grinder (food waste disposal); secondary back flow preventer; and the replacement or repair of a sump pump.
3. The repair or replacement of a plumbing fixture; faucet or fixture fitting from the exposed stop valve to the inlet side of a trap not constituting an ordinary repair.
4. The repair of components of a plumbing appliance or plumbing appurtenance.
5. The replacement of a plumbing appurtenance.
6. The repair or replacement of plumbing piping, except gas piping, not longer than 25 feet (7620 mm), or connected piping previously repaired or replaced under this provision.
7. The repair or replacement of plumbing branch piping except gas piping, serving the dwelling unit and including the replacement of fixtures, limited to two bathrooms and 1 kitchen per dwelling unit.
105.3.1.2.3 Category 2 ordinary plumbing work.
Category 2 ordinary plumbing work shall be performed in accordance with this code and the New York City Fuel Gas Code. Work shall not include nor extend beyond the existing appliance gas cock or appliance valve. Prior to performing any of the described work, the plumber shall be responsible for verifying that the existing gas cock or appliance valve is accessible, in good working condition with no noticeable corrosion or deterioration, and in the closed off position. Where a replacement appliance is connected to a chimney, the plumber shall inspect the chimney and verify that it is in good operational condition. The replacement of any appliance must be in accordance with the manufacturer’s instructions and all applicable listings. After such replacement, the plumber shall re-open the existing gas cock or appliance valve and perform a leak check on all newly made gas piping and tubing connections by means of a combustible gas indicator or a noncorrosive leak detection fluid. Category 2 ordinary plumbing work shall be limited to the replacement of the following items:
1. In residential buildings occupied by 5 families or fewer, the replacement of a gas water heater, gas furnace, or a gas fired boiler with a capacity of 350,000 BTU or less.
2. The replacement of gas-burning domestic appliances limited to ranges, ovens, stoves, barbecues, and clothes dryers.
3. The replacement of an appliance connector serving a domestic range, oven, stove, barbecue, or clothes dryer.
105.3.1.3 Repairs to fire alarm systems.
Work constituting a repair to a fire alarm system that does not require a permit shall be performed in accordance with rules of the department.
105.3.1.4 Repairs to elevators and conveying systems.
Work constituting a repair to elevator or conveying system shall be performed in accordance with rules of the department.
105.3.2 Compliance.
No work shall make a building less compliant with this code and the New York City Construction Codes, Energy Code, Electrical Code and any other applicable laws, rules, and regulations than it was before the work was undertaken, reduce the structural, fire and life safety of the condition impacted, or create a new structural, fire or life safety hazard; otherwise, an application for a work permit shall be submitted to the department.
105.3.2.1 Owner’s responsibility.
It is the owner’s responsibility to ensure that all work performed pursuant to Section 105.3 complies with all applicable provisions of law and that such work is performed in a safe and code compliant manner.
105.3.2.1.1 Protection of adjacent or adjoining properties.
Building owners shall ensure the adjacent or adjoining properties are protected in accordance with Chapter 33 of the New York City Building Code .
105.3.2.1.2 Protection of occupied building.
During construction in an occupied building, as applicable to the scope of work, the owner shall:
1. Maintain the means of egress free of any obstruction.
2. Provide means to dispose of debris, control dust and noise, and pest control.
3. Notify tenants of any interruption to building systems.
4. Maintain life safety systems in accordance with the New York City Construction Codes and the New York City Fire Code.
5. Maintain essential services such as heat, cold and hot water, gas, and electricity in residential buildings, other than one- and two-family residences. Where disruption of service may occur due to the scope of work, the tenants shall be notified of the anticipated duration of such disruption.
6. Maintain the existing level of accessibility to building spaces and facilities.
105.3.2.2 Compliance with other agency and utility company requirements.
The owner and the licensee, where required, shall be responsible for obtaining any required approval, permit or certification by other agencies or utilities having jurisdiction over the work performed. Related approvals and permits from other agencies and jurisdictions may include, but are not limited to, the following:
1. Asbestos certification as required by Article 106 of Title 28 of the Administrative Code .
2. Approval from the Department of Environmental Protection.
3. Approval from the Landmarks Preservation Commission.
4. Approval or permit from the Fire Department.
5. Permit from the Department of Transportation.
105.3.2.3 Work not requiring permits performed as an integral part of work requiring permits.
Work types that may not require a permit but that are performed as an integral part of an alteration to the building that requires a permit shall be filed with the Department as part of such alteration subject to Chapter 5 and Chapters 8 through 14 of this code, as applicable.
105.3.2.4 Change in scope of work.
Where a change in the scope of work during the course of construction results in work that requires a permit, work must stop until such time as a permit is issued.
105.3.2.5 Related approvals and permits.
Where related permits are required in connection with the work scope such approvals and permits shall be obtained in accordance with Article 105 of Title 28 of the Administrative Code.
105.3.2.6 Building materials and systems.
Building materials and systems shall comply with the requirements of this section.
105.3.2.6.1 Existing materials.
Materials already in use in a building in compliance with requirements or approvals in effect at the time of their erection or installation shall be permitted to remain in use unless determined by this code to be unsafe pursuant to Section 115.
105.3.2.6.2 New and replacement materials, assemblies and details.
New and replacement materials, assemblies and details permitted by the applicable code for new construction shall be used in accordance with Section 302.4.
105.3.2.6.3 Glazing in hazardous locations.
Replacement glazing in hazardous locations shall comply with the safety glazing requirements of the New York City Building Code .
105.3.2.6.4 Used plumbing materials and supplies.
Used plumbing materials and supplies shall not be re-used where prohibited by the New York City Plumbing Code .
105.3.2.7 Accessibility.
Minor alterations to existing buildings that are performed without a permit shall comply with the accessibility requirements of Chapter 11 of the New York City Building Code. Such work shall not reduce the level of accessibility as described under Section 306.4.
Exception. Ordinary repairs do not need to comply with the accessibility requirements of Chapter 11 of the New York City Building Code .
105.3.2.7.1 Provisions for accessibility modifications to certain features in dwelling units after occupancy.
Modifications to certain features in dwelling units shall comply with Section 1107.2 of the New York City Building Code. Such features include bathtubs, showers, kitchen counters, appliances in kitchens and kitchenettes, refrigerators/freezers, kitchen and kitchenette storage, operable windows, storage facilities, and laundry equipment.
105.3.2.8 Energy conservation.
Minor alterations and ordinary repairs to existing buildings or structures as defined in Section 202 are permitted without requiring the entire building or structure to comply with the energy requirements of the New York City Energy Conservation Code. The minor alterations and ordinary repairs shall conform with the existing building provisions of the New York City Energy Conservation Code .
105.4 Permits with respect to limited alteration applications.
Permits shall be required for limited alteration applications, subject to Chapter 5 of this code, in accordance with Article 105 of Chapter 1 of Title 28 of the Administrative Code .
105.5 Validity of permit.
The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other laws. Permits presuming to give authority to violate or cancel the provisions of this code or law shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the commissioner from requiring the correction of errors in the construction documents and other data. The commissioner is authorized to prevent occupancy or use of a structure in violation of this code or of any other ordinances of this jurisdiction.
Section EBC 106. Construction Documents
106.1 General.
In accordance with Article 104 of Chapter 1 of Title 28 of the Administrative Code, each application for a permit shall be accompanied by submittal documents which include but are not limited to construction documents; special inspection, structural investigation, and evaluation reports; and other data required by the department. Such submittal shall be prepared by a registered design professional. The department shall not issue a permit pursuant to this code unless and until it approves all required construction documents for such work. In addition to the requirements of Article 104 of Chapter 1 of Title 28 of the Administrative Code, the commissioner is authorized to require additional construction documents to be submitted by a registered design professional to determine compliance with this code and other applicable laws and rules.
Exception: Construction documents shall not be required to be prepared by a registered design professional if they are exempt from such requirement, as provided for in Chapter 5 of this code, Section 28-104.6 of the Administrative Code, or rules of the department.
106.2 Construction documents.
Construction documents submitted in connection with alterations, additions, changes of use or occupancy and relocation of existing buildings shall comply with Article 104 of Chapter 1 of Title 28 of the Administrative Code, Section 107 of the New York City Building Code and with Sections 106.2.1 through 106.2.9 of this code.
106.2.1 Structural plans.
Structural plans shall include the data and information described in Section 107.7 and Chapter 16 of the New York City Building Code as applicable to alterations, additions, changes of use or occupancy and relocation of existing buildings. Additional documents shall be submitted as required by Section 702. Structural calculations shall be made available to the department upon request.
106.2.2 Fire protection system(s) plans.
Construction documents for fire protection systems shall include a plot plan to scale indicating the location of the system in relation to the rest of the building and shall comply with Section 107.9 of the New York City Building Code. Such plans shall not be required in connection with applications for limited standpipe alterations and limited sprinkler alterations subject to Chapter 5 of this code.
106.2.3 Means of egress.
The construction documents for Alterations – Level 1, Alterations – Level 2, additions and changes of occupancy where the means of egress are affected shall show in sufficient detail the location, construction, size and character of all portions of the means of egress in compliance with the provisions of this code and Chapter 10 of the New York City Building Code, as applicable. The construction documents shall designate the number of occupants to be accommodated in every work area of every floor and in all affected rooms and spaces.
106.2.4 Exterior wall envelope.
Construction documents for work affecting the exterior wall envelope shall describe the exterior wall envelope in sufficient detail to determine compliance with this code, the New York City Building Code and the New York City Energy Conservation Code. The construction documents shall provide, as required, details of the exterior wall envelope pertinent to the proposed work, including windows, doors, flashing, intersections with dissimilar materials, corners, end details, control joints, intersections at roof, eaves, or parapets, means of drainage, water-resistive membrane, and details around openings.
106.2.5 Site plan.
The construction documents submitted with the application for permit shall be accompanied by a site plan showing to scale the size and location of proposed work and existing structures on the site and distances from lot lines. Where the work involves horizontal additions or relocation of existing buildings, the site plan shall be drawn in accordance with an accurate boundary line survey. In the case of demolition, the site plan shall show construction to be demolished and the location and size of existing structures and construction that are to remain on the site or lot. The commissioner is authorized to waive or modify the requirement for a site plan where the application for permit is for alteration or change of occupancy that will not affect site conditions. Additional details may be required by the department.
106.2.5.1 Zoning.
Where the proposed work requires compliance with the New York City Zoning Resolution, the site plan shall include the entire zoning lot with details required to demonstrate compliance.
106.2.5.1.1 Multiple tax lots on a zoning lot.
Where an existing building is being enlarged and the zoning lot comprises multiple tax lots, construction documents shall comply with Section 28-104.7.18 of the Administrative Code.
106.2.6 Energy efficiency.
Construction documents shall include compliance documentation as required by the New York City Energy Conservation Code .
106.2.7 Mechanical and fuel gas systems plans.
Construction documents for gas piping, heating, ventilation, refrigeration and other mechanical work to be performed shall be submitted as required by the New York City Mechanical Code and the New York City Fuel Gas Code .
106.2.8 Plumbing plans.
Construction documents for plumbing work to be performed shall be submitted as required by the New York City Plumbing Code .
106.2.9 Special requirements.
Certain types of work shall be included and identified in the construction documents in accordance with Sections 106.2.9.1 through 106.2.9.6, as applicable.
106.2.9.1 Identification of work involving relocation, moving or raising a building.
Where an existing building is being relocated, moved, or the lowest above-grade floor or the lowest subgrade floor of a building is to be raised, lifted or elevated, such work shall be listed on the title sheet of the construction documents as subject to special inspection. Refer to Section 28-104.7.13 of the Administrative Code .
106.2.9.2 Identification of certain I-1 and I-2 occupancies and of certain adult homes, enriched housing, community residences and intermediate care facilities as exempt from temporary external generator connection requirements.
Refer to Section 28-104.7.14 of the Administrative Code .
106.2.9.3 Identification of certain hospitals as exempt from temporary external boiler or chiller connection requirements.
Refer to Section 28-104.7.15 of the Administrative Code .
106.2.9.4 Tenant protection plan.
The title sheet of construction documents shall contain a statement that a tenant protection plan must be submitted in accordance with the requirements of Section 1503 of this code and Section 28-104.7.16 of the Administrative Code prior to the issuance of a permit for alteration, construction or partial demolition work in a building containing 1 or more occupied dwelling units.
106.2.9.5 Coastal zones and water-sensitive inland zones.
Construction documents for work relating to alterations of existing buildings in coastal zones and water-sensitive inland zones shall comply with Section 28-104.9 of the Administrative Code .
106.2.9.6 Discharge of sewage and discharge and/or management of stormwater runoff.
Applications for construction document approval shall comply with Sections 106.2.9.6.1 and 106.2.9.6.2.
106.2.9.6.1 Sewage.
Applications for construction document approval shall include submittal documents relating to the availability and feasibility of a public sanitary or public combined sewer in accordance with Section 107.11.1 of the New York City Building Code and Section 107.6.1 of the New York City Plumbing Code, for the following types of applications:
1. Alterations that require an increase in size to an existing sanitary or combined sewer connection; and/or
2. Alterations requiring a new connection to a sanitary or combined sewer.
106.2.9.6.2 Stormwater.
Applications for construction document approval shall include submittal documents relating to the availability and feasibility of a public combined or storm sewer or other approved method for stormwater discharge in accordance with Section 107.11.2 of the New York City Building Code and Section 107.6.2 of the New York City Plumbing Code, for the following types of applications:
1. Alterations of buildings proposing horizontal building enlargement; and/or
2. Alterations that increase impervious surfaces on the tax lot.
Exceptions:
1. Applications for construction document approval for the alteration of an existing building other than a one- or two-family dwelling need not include such submittal documents, where the increase in area of the footprint resulting from a proposed horizontal building enlargement and any proposed increase in impervious surfaces on a lot combined is less than or equal to 1,000 square feet (93 m 2 ), and on-site disposal of stormwater conforming to the provisions of the applicable laws and rules as determined by the department is proposed for such enlargement and/or increase in impervious surface. In such cases, the stormwater discharge may be accommodated by existing facilities. Construction documents shall include the amount of proposed increase in impervious area. For the purposes of this exception, the 1,000 square feet (93 m 2 ) area shall include all cumulative enlargements and increases in impervious surface area made on the same tax lot after July 1, 2008.
1.1. This exception shall not apply where on-site disposal cannot be designed to conform to the provisions of the applicable laws and rules including but not limited to minimum required distances from lot lines or structures or subsoil conditions as determined by the department.
2. Applications for construction document approval for the alteration of an existing one- or two-family dwelling need not include such submittal documents, where the total area of a proposed horizontal building enlargement plus any proposed increase in impervious surfaces is less than or equal to 200 square feet (19 m 2 ). Construction documents shall include the amount of proposed increase in impervious surface area. For the purposes of this exception, the 200 square feet (19 m 2 ) area shall include all cumulative enlargements and increases in impervious surface area made on the same tax lot after July 1, 2008.
106.2.9.6.3 Post-construction stormwater management facilities.
A post-construction stormwater management facility shall comply with Section 107.11.3 of the New York City Building Code .
106.3 Additional requirements.
Alterations, additions, repairs, changes of occupancy and relocations of existing buildings shall comply with the following additional requirements as applicable:
1. Asbestos investigation pursuant to Article 106 of Chapter 1 of Title 28 of the Administrative Code .
2. Alteration or demolition of single room occupancy multiple dwellings pursuant to Article 107 of Chapter 1 of Title 28 of the Administrative Code .
3. Pavement plan pursuant to Article 108 of Chapter 1 of Title 28 of the Administrative Code .
4. Fire protection plan pursuant to Article 109 of Chapter 1 of Title 28 of the Administrative Code .
5. Site safety plan pursuant to Article 110 of Chapter 1 of Title 28 of the Administrative Code .
106.4 Phased or partial approval.
In the case of construction documents for the alteration of a building, the commissioner may grant partial approval in accordance with Section 28-104.2.5 of the Administrative Code.
Section EBC 107. Temporary Structures and Uses
107.1 General.
Refer to Article 111 of Chapter 1 of Title 28 of the Administrative Code .
Section EBC 108. Fees
108.1 Payment of fees.
A permit, inspection, or other service or privilege as regulated in this code shall not be valid until the fees prescribed by Article 112 of Chapter 1 of Title 28 of the Administrative Code or in rules have been paid, nor shall a renewal of a permit or other service or privilege or an amendment to a permit be released until the fee has been paid.
Section EBC 109. Inspections
109.1 General.
Except as otherwise specified, inspections required by this code or by the department during the progress of work may be performed on behalf of the owner by approved agencies including, where applicable, by special inspectors. However, in the interest of public safety, the commissioner may direct that any of such inspections be performed by the department. All inspections shall be performed at the sole cost and expense of the owner. Refer to Article 116 of Chapter 1 of Title 28 of the Administrative Code and Section 110 of the New York City Building Code, for additional provisions relating to inspections.
109.1.1 Tenant protection plan compliance inspection.
For buildings undergoing work for which a tenant protection plan is required by Section 1503, inspections shall be performed by the department to determine compliance with the tenant protection plan in accordance with Section 1503.11.
109.1.2 Architectural conditions assessment.
Where an existing building is being altered and the work area exceeds 50 percent of the floor area, the design professional of record shall perform an assessment of certain building elements within the work area to evaluate their condition. Such assessment shall be performed in accordance with Section 803.10.
109.1.3 Structural conditions assessment.
Initial and detailed conditions assessment shall be performed before and during the construction phase of the project as provided for in Section 704.
109.2 Special inspections.
Work subject to special inspection shall comply with the applicable provisions of Chapter 17 of the New York City Building Code .
Section EBC 110. Certificate of Occupancy
110.1 General.
Refer to Article 118 of Chapter 1 of Title 28 of the Administrative Code .
Section EBC 111. Service Utilities
111.1 General.
Refer to Article 119 of Chapter 1 of Title 28 of the Administrative Code .
Section EBC 112. Reserved
BetaNYC's copy has no text for this section. Read Section EBC 112 at American Legal Publishing.
Section EBC 113. Violations
113.1 General.
Refer to Chapter 2 of Title 28 of the Administrative Code .
Section EBC 114. Stop Work Order
114.1 General.
Refer to Article 207 of Chapter 2 of Title 28 of the Administrative Code .
Section EBC 115. Reserved
BetaNYC's copy has no text for this section. Read Section EBC 115 at American Legal Publishing.
Section EBC 116. Emergency Measures
116.1 General.
Refer to Chapter 2 of Title 28 of the Administrative Code .
Section EBC 117. Demolition
117.1 General.
Refer to Chapter 33 of the New York City Building Code .
Section EBC 118. Maintenance of Buildings
118.1 General.
The provisions of this section shall apply to maintenance and periodic inspections of existing buildings. The requirements of Chapter 3 of Title 28 of the Administrative Code relating to maintenance and periodic inspections of existing buildings shall also apply.
118.1.1 Requirements.
All buildings and all parts thereof shall be maintained and periodically inspected in accordance with Section 118.2 of this code pursuant to Chapter 3 of Title 28 of the Administrative Code .
118.1.2 Owner’s responsibilities.
The owner shall be responsible at all times to maintain the building and its facilities and all other structures regulated by this code and other applicable codes in a safe and code-compliant manner and shall comply with the inspection and maintenance requirements of Chapter 3 of Title 28 of the Administrative Code .
118.1.3 Filing of reports.
Reports required to be filed in accordance with Chapter 3 of Title 28 of the Administrative Code, shall be filed in writing or electronically as the commissioner may require.
118.2 Maintenance and periodic inspections.
Maintenance and periodic inspections shall be required to be performed in accordance with Chapter 3 of Title 28 of the Administrative Code and Sections 118.2.1 through 118.2.21 of this code.
118.2.1 Parapets.
A building’s parapet shall be maintained in a safe condition as required by Article 301 of Chapter 3 of Title 28 of the Administrative Code .
118.2.2 Maintenance of exterior walls.
A building’s exterior walls and appurtenances thereof shall be maintained in a safe condition. All buildings greater than 6 stories shall comply with the maintenance requirement of Article 302 of Chapter 3 of Title 28 of the Administrative Code .
118.2.3 Periodic boiler inspections.
Periodic boiler inspections shall be performed in accordance with Article 303 of Chapter 3 of Title 28 of the Administrative Code .
118.2.4 Elevators and conveying systems.
Elevators and conveying systems shall be maintained in a safe condition and in accordance with ASME A17.3, as modified by Appendix K of the New York City Building Code. Every new and existing elevator or conveying system shall be inspected and tested in accordance with Article 304 of Chapter 3 of Title 28 of the Administrative Code .
118.2.5 Retaining walls, partition fences and other site structures.
In addition to the requirements set forth in Chapter 33 of the New York City Building Code, the responsibility for maintaining and repairing retaining walls, partition fences and other site structures shall be in accordance with Article 305 of Chapter 3 of Title 28 of the Administrative Code .
118.2.6 Party walls.
Party walls shall be maintained in accordance with Article 306 of Chapter 3 of Title 28 of the Administrative Code .
118.2.7 Workplace exits.
Workplace exits shall be unobstructed in accordance with Article 307 of Chapter 3 of Title 28 of the Administrative Code and it shall be unlawful for an employer or the agent of an employer to lock the doors of a workplace or otherwise obstruct or prohibit exit from a workplace when such act may endanger the health or safety of any employee, independent contractor or other individual in such workplace.
118.2.8 Energy audits and retro-commissioning of base building systems.
Energy audits and retro-commissioning of base building systems shall be subject to Article 308 of Chapter 3 of Title 28 of the Administrative Code .
118.2.9 Benchmarking energy and water use.
The energy and water use of city buildings and covered buildings shall be benchmarked in accordance with Article 309 of Chapter 3 of Title 28 of the Administrative Code .
118.2.10 Required upgrade of lighting systems.
Lighting systems in covered buildings shall be upgraded as provided in Article 310 of Chapter 3 of Title 28 of the Administrative Code .
118.2.11 Installation of electrical sub-meters in tenant spaces.
Sub-meters shall be installed in covered buildings as provided in Article 311 of Chapter 3 of Title 28 of the Administrative Code .
118.2.12 Carbon monoxide and smoke alarms.
Required carbon monoxide and smoke alarms shall comply with the provisions of Article 312 of Chapter 3 of Title 28 of the Administrative Code .
118.2.13 Cooling towers.
All owners of cooling towers shall comply with Article 317 of Chapter 3 of Title 28 of the Administrative Code .
118.2.14 Periodic inspection of gas piping systems.
Building gas piping systems, other than gas piping systems of buildings classified in Occupancy Group R-3, shall be periodically inspected in accordance with Article 318 of Chapter 3 of Title 28 of the Administrative Code .
118.2.15 Maintenance and removal of small wind turbines.
Maintenance and removal of small wind turbines or small wind turbine towers shall be in accordance with Article 319 of Chapter 3 of Title 28 of the Administrative Code .
118.2.16. Building energy and emission limits.
Owners of covered buildings shall comply with the requirements for annual building emissions limits in Article 320 of Chapter 3 of Title 28 of the Administrative Code.
118.2.17 Energy conservation measure requirements for certain buildings.
Owners of covered buildings shall comply with the energy conservation measures in Article 321 of Chapter 3 of Title 28 of Administrative Code .
118.2.18 Maintenance and removal of large wind turbines.
Maintenance and removal of large wind turbines or large wind turbines tower shall be in accordance with Article 322 of Chapter 3 of Title 28 of the Administrative Code .
118.2.19 Periodic inspection of parking structures.
Parking structures shall be maintained and periodically inspected in accordance with Article 323 of Chapter 3 of Title 28 of the Administrative Code .
118.2.20 Periodic inspection of dry floodproofing.
Covered buildings and structures that are required to comply with the dry floodproofing of Appendix G of the New York City Building Code where human intervention is required to activate or implement the dry floodproofing system prior to a flood event shall comply with Article 324 of Chapter 3 of Title 28 of the Administrative Code .
118.2.21 Annual inspections to prevent contamination of mechanical systems.
Covered buildings and structures with exhaust ducts under positive pressure, chimneys, and vents that extend into or pass through ducts or plenums shall be subject to annual inspection as required by Article 325 of Chapter 3 of Title 28 of the Administrative Code .
Section EBC 119. Retroactive Requirements
119.1 General.
All existing buildings, structures and open uses shall comply with the retroactive requirements of the provisions of Article 315 of the Administrative Code, including all previously enacted retroactive requirements of the 1968 Building Code, as applicable. The department shall provide a list of such provisions on its website.
Section EBC 201. General
201.1 Scope.
Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code, have the meanings indicated in this chapter.
201.2 Interchangeability.
Words used in the present tense include the future; words in the masculine gender include the feminine and neuter; the singular number includes the plural and the plural, the singular.
201.3 Terms defined in other codes.
Where terms are not defined in this code and are defined in the New York City Building Code, the New York City Electrical Code, the New York City Fire Code, the New York City Fuel Gas Code, the New York City Mechanical Code, the New York City Plumbing Code, or the New York City Energy Conservation Code, such terms shall have meanings ascribed to them as in those codes.
201.3.1 Terms defined in the general administrative provisions.
The following terms are defined in Section 28-101.5 of the Administrative Code:
1968 BUILDING CODE.
ACCEPTANCE OR ACCEPTED.
ADDITION.
ADMINISTRATIVE CODE.
ALTERATION.
APPROVAL OR APPROVED.
APPROVED AGENCY.
APPROVED FABRICATOR.
APPROVED INSPECTION AGENCY.
APPROVED TESTING AGENCY.
ARCHITECT.
BUILDING.
CHARTER.
CERTIFICATE OF COMPLIANCE.
CITY.
COMMISSIONER.
CONSTRUCTION DOCUMENTS.
DAY.
DEFERRED SUBMITTAL.
DEMOLITION.
DEMOLITION, FULL.
DEMOLITION, PARTIAL.
DEPARTMENT.
ENGINEER.
ENLARGEMENT.
ENVIRONMENTAL CONTROL BOARD or ECB.
EXISTING BUILDING OR STRUCTURE.
FABRICATED ITEM.
FIRE PROTECTION PLAN.
HEREAFTER.
HERETOFORE.
INSPECTION CERTIFICATE.
INTERIM CERTIFICATE OF OCCUPANCY.
LABEL.
LABELED.
LAND SURVEYOR.
LANDSCAPE ARCHITECT.
LETTER OF COMPLETION.
LISTED.
MAIN USE OR DOMINANT OCCUPANCY (OF A BUILDING).
MANUFACTURER’S DESIGNATION.
MARK.
MATERIALS.
OCCUPANCY.
OWNER.
PARTY WALL.
PERMIT.
PERSON.
PREMISES.
PRIOR CODE BUILDING OR STRUCTURE.
PROFESSIONAL CERTIFICATION.
PROGRESS INSPECTION.
PROJECT.
REGISTERED DESIGN PROFESSIONAL.
REGISTERED DESIGN PROFESSIONAL OF RECORD.
REQUIRED.
RETAINING WALL.
SERVICE EQUIPMENT.
SIGN-OFF.
SINGLE ROOM OCCUPANCY MULTIPLE DWELLING.
SPECIAL INSPECTION.
SPECIAL INSPECTION AGENCY.
SPECIAL INSPECTOR.
STRUCTURE.
SUBMITTAL DOCUMENTS.
SUPERINTENDENT OF CONSTRUCTION (CONSTRUCTION SUPERINTENDENT).
USE (USED).
UTILITY COMPANY OR PUBLIC UTILITY COMPANY.
UTILITY CORPORATION OR PUBLIC UTILITY CORPORATION.
WORK NOT CONSTITUTING MINOR ALTERATIONS OR ORDINARY REPAIRS.
WRITING (WRITTEN).
WRITTEN NOTICE.
ZONING RESOLUTION.
201.4 Terms not defined.
Where terms are not defined through the methods authorized by this section, such terms shall have ordinarily accepted meanings such as the context implies.
Section EBC 202. Definitions
1938 BUILDING CODE. See Appendix D.
1968 BUILDING CODE. The building laws and regulations in effect prior to July 1, 2008.
ALTERATION. Any construction, addition, change of use or occupancy, relocation, moving or raising of an existing building or structure for the purpose of renovation or accommodation of a new use or function.
ALTERATION, LEVEL 1. An alteration made to an existing building or structure, other than an addition, a change of occupancy or relocation, moving or raising of a building, where the work area does not exceed 50 percent of the building area. Such Level 1 Alteration shall be subject to Chapter 8.
ALTERATION, LEVEL 2. An alteration made to an existing building or structure, other than an addition, a change of occupancy or relocation, moving or raising of a building, where the work exceeds 50 percent of the building area. Such Level 2 Alteration shall be subject to Chapter 9.
ALTERATION, LIMITED. Alterations filed with the Department pursuant to Chapter 5. Such alteration shall not include any associated alteration that would otherwise require the filing of a plan by a registered design professional.
AREA, BUILDING. For the purpose of calculating work area as a percentage of building area, building area shall be calculated to include the floor area of the entire building including above and below grade stories exclusive of vent shafts and courts. All measurements shall include thickness of exterior walls.
BASEMENT (MDL 4(38)). See Appendix D.
BSE-1N. An acronym for an earthquake type described in ASCE 41, the Basic Safety Earthquake-1 for use with the Basic Performance Objective to New Building Standards and taken as two thirds of BSE-2N at a site.
BSE-2N. An acronym for an earthquake type described in ASCE 41, the Basic Safety Earthquake-2.
BUILDING, MOVED. A building that is moved horizontally within the same lot.
BUILDING, RAISED. A building or portion thereof that is raised vertically by disconnecting it from its foundation or structural supports.
BUILDING, RELOCATED. A building or portion thereof that is relocated to a different lot on new foundation.
BUILDING, RELOCATABLE. A partially or completely assembled building constructed and designed to be reused multiple times and transported to different sites.
CELLAR (MDL 4(37)). See Appendix D.
CHANGE OF OCCUPANCY. A change in the use of the building or a portion of a building. A change of occupancy shall include any change of occupancy classification, any change from one group to another group within an occupancy classification or any change in use within a group for a specific occupancy classification, subject to Chapter 10.
CLASS A MULTIPLE DWELLING (MDL 4(8)). See Appendix D.
CLASS B MULTIPLE DWELLING (MDL 4(9)). See Appendix D.
CONVERTED DWELLING (MDL 4(10)). See Appendix D.
COURT (MDL 4(32)). See Appendix D.
COURT, INNER (MDL 4(32)). See Appendix D.
COURT, OUTER (MDL 4(32)). See Appendix D.
CUBICLE (MDL 4(21)). See Appendix D.
CURB LEVEL (MDL 4(33)). See Appendix D.
DANGEROUS. Any building, structure or portion thereof that meets any of the conditions described below shall be deemed dangerous:
1. The building or structure has collapsed, has partially collapsed, has moved off its foundation; is excessively leaning, bowing, or bulging; or lacks the necessary support of the ground.
2. There exists a significant risk of collapse, detachment or dislodgement of any portion, member, wall, appurtenance or ornamentation of the building or structure.
DEMAND. Loads and deflections imposed on structural elements in accordance with the load combinations of the New York City Building Code.
DEMAND CAPACITY RATIO. The numeric ratio of demand divided by the capacity of a structural system, member or connection.
DWELLING (MDL 4(4)). See Appendix D.
DWELLING UNIT. See Appendix D.
EQUIPMENT OR FIXTURE. Any plumbing, heating, electrical, ventilating, air conditioning, refrigerating and fire protection equipment; elevators, dumb waiters and escalators; and boilers, pressure vessels and other mechanical facilities or installations that are related to building services. Equipment or fixture shall not include manufacturing, production or process equipment, but shall include connections from building service to process equipment.
FACILITY (ACCESSIBILITY). For the purpose of applying the accessibility provisions, a facility is all or any portion of buildings, structures, site improvements, elements and pedestrian or vehicular routes located on a site.
FACILITY (OCCUPANCY). For the purpose of applying occupancy requirements, a facility shall mean the building or portion thereof that is occupied by 1 primary use and where spaces within such facility may change in purpose or function without changing the primary use of the facility.
FIRE ESCAPE (MDL 4(42)(c)). See Appendix D.
FIRE-RETARDED (MDL 4(29)). See Appendix D.
FIREPROOF (MDL 4(26)). See Appendix D.
FIREPROOF MULTIPLE DWELLING (MDL 4(25)). See Appendix D.
FLOOD HAZARD AREA. See Chapter 2 of the New York City Building Code.
FLOOR SPACE (MDL 4(18)). See Appendix D.
FRAME DWELLING (MDL 4(28)). See Appendix D.
FRONT/REAR WALL. An exterior masonry wall that faces a street or backyard. Typically, it has more window openings and is shorter in length than the masonry walls in the perpendicular direction. See also SIDE WALL.
GRAVITY LOAD. Gravity loads are forces resulting from the self-weight of a building and its use, including dead, live, snow, rain and ice loads.
HEIGHT (MDL 4(35)). See Appendix D.
HOME IMPROVEMENT CONTRACTOR. A person licensed to engage in the home improvement business by the Department of Consumer and Worker Protection in accordance with Subchapter 22 of Chapter 2 of Title 20 of the Administrative Code.
HOTEL (MDL 4(12)). See Appendix D.
LATERAL FORCE-RESISTING SYSTEM. Denotes structural systems specifically designated to resist loads imposed on a structure by seismic action, wind or retained earth and water.
LIMITED ALTERATION APPLICATION. Application for limited oil-burning appliance alterations, limited plumbing alterations, limited sprinkler alterations, limited standpipe alterations, limited home improvement alterations, limited window replacement alterations, limited reroofing replacement alterations or limited elevator alterations, filed with the department pursuant to Chapter 5 of this code. Such work shall not include any associated work that would otherwise require an alteration permit including, but not limited to, any construction of fire rated partitions and enclosures.
Category 1 work shall be limited to a new installation into an existing building or system. The utilization of this category shall be limited by an annual monetary cap.
Category 2 work shall include any existing system(s) or components that are replaced, repaired or altered. This category shall not be limited by a monetary cap.
Category 3 work shall include any work of an existing system that does not require mandatory department inspection and is subject to fees as determined by the department.
LIMITED ELEVATOR ALTERATIONS. An alteration to an existing elevator that is limited in scope, subject to Chapter 5 of this code.
LIMITED HOME IMPROVEMENT ALTERATIONS. An alteration to an existing one- or two-family dwelling that is limited in scope, subject to Chapter 5 of this code.
LIMITED OIL-BURNING APPLIANCE ALTERATIONS. An alteration to an oil burner/boiler system that is limited in scope and/or value, subject to Chapter 5 of this code.
LIMITED PLUMBING ALTERATIONS. An alteration to a plumbing or fuel gas piping system that is limited in scope and/or value, subject to Chapter 5 of this code.
LIMITED REROOFING ALTERATIONS. A reroofing alteration that is limited in scope, subject to Chapter 5 of this code.
LIMITED SPRINKLER ALTERATIONS. An alteration to a sprinkler system that is limited in scope and or value, subject to Chapter 5 of this code.
LIMITED STANDPIPE ALTERATIONS. An alteration to an existing combined standpipe system that is limited in scope and/or value, subject to Chapter 5 of this code.
LIMITED WINDOW REPLACEMENT ALTERATIONS. A window replacement alteration that is limited in scope, subject to Chapter 5 of this code.
LIVING ROOM (MDL 4(18)). See Appendix D.
LODGING HOUSE (LH) (MDL 4(14)). See Appendix D.
LOT LINE AIR SHAFT. An interior court enclosed by building walls except for 1 lot line, adjoined by another interior court of similar size and shape on the adjacent lot, both forming an air shaft between the two existing buildings with window openings upon this shaft that may or may not be used for light and ventilation.
MDL. See Appendix D.
MINOR ALTERATIONS. Minor changes or modifications in a building or any part thereof, excluding additions thereto, that do not in any way affect health or the fire or structural safety of the building or the safe use and operation of the service equipment therein. Minor alterations shall not include any of the work described as “work not constituting minor alterations or ordinary repairs.” Minor Alterations are subject to Section 105.3.
MULTIPLE DWELLING (MDL 4(7)). See Appendix D.
NONCOMBUSTIBLE MATERIAL. A material that, under the conditions anticipated, will not ignite or burn when subjected to fire or heat. Materials that pass ASTM E 136 are considered noncombustible materials.
NON-FIREPROOF MULTIPLE DWELLING (MDL 4(27)). See Appendix D.
ORDINARY REPAIRS. Replacements or renewals of existing work in a building, or of parts of the service equipment therein, with the same or equivalent materials or equipment parts that are made in the ordinary course of maintenance and that do not in any way affect health or the fire or structural safety of the building or the safe use and operation of the service equipment therein. Ordinary repairs shall include the repair or replacement of any plumbing fixture, piping or faucets from any exposed stop valve to the inlet side of a trap. Ordinary repairs shall not include any of the work described as “work not constituting minor alterations or ordinary repairs.” Ordinary repairs are subject to Section 105.3.
ORDINARY PLUMBING WORK. The installation, relocation, repair and removal of certain plumbing work that may be performed without a permit provided the licensed plumber provides the department with monthly reports of work performed in accordance with Section 105.3.1.2.
PRIMARY FUNCTION. A primary function is a major activity for which the facility is intended. Areas that contain a primary function include, but are not limited to, the customer services lobby of a bank, the dining area of a cafeteria, the meeting rooms in a conference center, as well as offices and other work areas in which the activities of the public accommodation or other private entity using the facility are carried out. Mechanical rooms, boiler rooms, supply storage rooms, employee lounges or locker rooms, janitorial closets, entrances, corridors and restrooms are not areas containing a primary function.
PRIOR CODE BUILDING OR STRUCTURE. A building or structure that is subject to Exception 1 or 2 of Section 28-101.4 of the Administrative Code.
PUBLIC HALL (MDL 4(17)). See Appendix D.
PUBLIC ROOM OR PART (MDL 4(17)). See Appendix D.
PUBLIC VESTIBULE (MDL 4(17)). See Appendix D.
REAR WALL. See FRONT/REAR WALL.
REAR YARD (MDL 4(32)). See Appendix D.
REPAIR. The reconstruction or renewal of any part of an existing building for the purpose of its maintenance or to correct damage.
REROOFING. The process of recovering or replacing an existing roof covering. See “Roof recover” and “Roof replacement.”
ROOF RECOVER. The process of installing an additional roof covering over a prepared existing roof covering without removing the existing roof covering.
ROOF REPAIR. Reconstruction or renewal of any part of an existing roof for the purposes of its maintenance.
ROOF REPLACEMENT. The process of removing the existing roof covering, repairing any damaged substrate and installing a new roof covering.
ROOMING HOUSE, FURNISHED ROOM HOUSE (MDL 4(13)). See Appendix D.
SIDE WALL. An exterior masonry wall that is not the front or rear wall.
SINGLE ROOM OCCUPANCY (MDL 4(16)). See Appendix D.
SMOKE-STOP DOOR. A door or set of doors placed in a corridor to restrict the spread of smoke and to retard the spread of fire by reducing draft.
STORY (MDL 4(36)). See Appendix D.
STREET WALL (MDL 4(34)). See Appendix D.
STRUCTURAL ALTERATION. Work performed on a structural element or that increases the loading on a structural element in an existing building.
STRUCTURAL ELEMENT. Any member or portion of a building structure or non-building structure, or its connections or foundations, that resist structural loads defined in Chapter 16 of the New York City Building Code.
SUBSTANTIAL DAMAGE. See Chapter 2 of the New York City Building Code.
SUBSTANTIAL IMPROVEMENT. See Chapter 2 of the New York City Building Code.
TECHNICALLY INFEASIBLE. An alteration of a facility that has little likelihood of being accomplished because the existing structural conditions require the removal or alteration of a load-bearing member that is an essential part of the structural frame, or because other existing physical or site constraints prohibit modification or addition of elements, spaces or features that are in full and strict compliance with the minimum requirements for new construction and that are necessary to provide accessibility.
TENEMENT (MDL 4(11)). See Appendix D.
TENEMENT, NEW LAW (NL) (MDL 4(11)). See Appendix D.
TENEMENT, OLD LAW (OL) (MDL 4(11)). See Appendix D.
UNSAFE. Buildings, structures or equipment that are unsanitary; that are deficient due to inadequate means of egress facilities, inadequate light and ventilation; that constitute a fire hazard; in which the structure or individual structural members meet the definition of “Dangerous”; that are otherwise dangerous to human life or the public welfare; or that involve illegal or improper occupancy or inadequate maintenance shall be deemed unsafe. A vacant structure that is not secured against entry shall be deemed unsafe.
WORK AREA. That portion or portions of a building consisting of all reconfigured spaces as indicated on the construction documents and described in Chapter 6.
Section EBC 301. Administration
301.1 General.
The repair, alteration, partial demolition, removal, change of occupancy or relocation, moving, or raising of or addition to existing buildings and structures shall comply with this chapter and the applicable chapters of this code based on the scope of work. Sections 301.1.1 through 301.1.5 shall not be applied in combination with each other unless specifically required by this code.
301.1.1 Work not requiring permits.
Work not requiring permits, including minor alterations and ordinary repairs, shall comply with this chapter, as applicable, and Section 105.3.
301.1.2 Limited alterations.
Limited alterations shall comply with this chapter, as applicable, and Chapter 5 of this code.
301.1.3 Work area compliance method.
Alterations, additions and changes in occupancy including relocated, moved or raised buildings or structures, as classified in Chapter 6, shall comply with the applicable provisions of this chapter, Chapters 7 through 11 and Chapter 14.
301.1.4 Building safety performance and scoring method.
For alterations made to existing buildings constructed prior to July 1, 2008, the registered design professional of record shall be permitted to comply with Chapter 13 as an alternative to compliance with the fire safety and means of egress provisions of this chapter and Chapters 8 through 11, as shown in Table 301.1.4. In order for the building to be considered in compliance with this method, the evaluation performed in accordance with Chapter 13 shall yield a passing score for each category set forth in Section 1304, in accordance with rules promulgated by the Department.
Table 301.1.4 Applicability of Chapter 13
CHAPTER / SCOPE OF WORK SECTIONS THAT MAY BE SATISFIED BY COMPLIANCE WITH CHAPTER 13 Chapter 3, Provisions for all compliance methods 304 Fire protection 305 Means of egress Chapter 8, Level 1 alteration 803 Building elements and materials 804 Fire protection 805 Means of egress Chapter 9, Level 2 alteration 903 Building elements and materials 904 Fire protection 905 Means of egress Chapter 10, Change of occupancy 1003 Building elements and materials 1004 Fire protection 1005 Means of egress Chapter 11, Additions 1102 Heights and areas 1104 Fire protection 1105 Means of egress
301.1.5 Relocated, moved or raised buildings.
Relocated, moved or raised buildings, including relocatable buildings, shall comply with this chapter, as applicable, and Chapter 14.
Section EBC 302. General Provisions
302.1 Applicability.
The provisions of Sections 302 through 314 shall apply to all repairs, alterations, additions, and relocations of buildings and structures and changes of occupancy.
302.2 Additional codes.
Repairs, alterations, additions and changes of occupancy to, or relocation of existing buildings and structures shall comply with the provisions for repairs, alterations, additions and changes of occupancy or relocation of buildings, respectively, in this code and the New York City Building Code, New York City Energy Conservation Code, New York City Fuel Gas Code, New York City Mechanical Code, New York City Plumbing Code and New York City Electrical Code. Where provisions of such other codes conflict with provisions of this code, the provisions of this code shall take precedence.
302.3 Existing materials.
Materials already in use in a building in compliance with requirements or approvals in effect at the time of their erection or installation shall be permitted to remain in use unless determined by the commissioner to be unsafe.
302.4 New and replacement materials, assemblies and details.
Except as otherwise required or permitted by this code, materials, assemblies, and details permitted by the New York City Construction Codes shall be used. Hazardous materials, assemblies and details shall not be used where the requirements of the New York City Construction Codes applicable to new construction would not permit their use in buildings of similar occupancy, purpose and location. New or replacement materials for buildings and spaces located below the design flood elevation in flood hazard areas shall be governed by Appendix G of the New York City Building Code.
Exception: For partial and restorative repairs, where such repairs are necessitated by deteriorating façade or roof conditions and are required by the New York City Construction Codes, like materials, assemblies and details are permitted if no unsafe condition is created and the registered design professional determines that compliance with the New York City Energy Conservation Code would overload or burden building systems or lead to unsafe conditions such as freeze-thaw cracking, blockage of a cavity, condensation, or mold. Insulation where present shall be restored in kind, and additional insulation need not be added to the repaired assembly as may be required by the New York City Energy Conservation Code, if the aforementioned negative conditions would be created. This exception applies to partial and restorative repairs, and not to whole building or full elevation replacement, which would require compliance with Chapter 4 of the New York City Energy Conservation Code.
302.5 Occupancy and use.
When determining the appropriate application of the referenced sections of this code, the occupancy and use of a building shall be determined in accordance with Chapter 3 of the New York City Building Code.
302.5.1 Occupancy classification in prior code buildings.
For prior code buildings, the prior codes’ occupancy classifications shall be translated into occupancy classifications established by Chapter 3 of the New York City Building Code.
302.6 Existing buildings in fire districts.
Alterations, additions, changes of use or occupancy and relocations of existing buildings inside the fire district, as described in Appendix D of the New York City Building Code, shall be subject to Chapter 6 of the New York City Building Code, and Sections 302.6.1 and 302.6.2 and other applicable provisions of this code.
302.6.1 Group H-1 prohibited.
New Group H-1 occupancies shall be prohibited within the fire district. Change of occupancy classification to, or enlargement of, Group H-1 occupancies shall be prohibited within the fire district.
302.6.2 Changes to buildings.
An existing building shall not be hereafter altered, increased in height or area, changed to a new use or occupancy, relocated or moved into the fire district unless such building is of a type of construction permitted for new buildings within the fire district in accordance with the New York City Building Code and Chapters 8, 9, 10, 11 and 14 of this code.
302.7 Work that increases floor surface area of an existing building by more than 110 percent.
Where proposed work at the completion of construction will increase the amount of floor surface area of an existing building by more than 110 percent over the amount of existing floor surface area, such entire building shall be made to comply with the provisions of the New York City Building Code as if it were a new building hereafter erected.
302.7.1 Floor surface area to remain.
For the purpose of determining the amount of existing floor surface area to remain, the following shall be excluded from the measured square footage:
1. The square footage of floors or portions thereof removed during the course of the work when such floors are removed together with the supporting beams, joists, decking and slabs on grade.
2. The square footage of floors or portions thereof installed together with the supporting beams, joists, decking and slabs on grade less than 12 months prior to submission of the application for construction document approval for the proposed work including floors installed pursuant to a work permit signed off less than 12 months before such submission.
302.7.2 Calculation of increase in floor surface area.
To determine the percentage by which the floor surface area is increased, the following formula shall be used:
I = (FSA P – FSA R ) / FSA R x 100 (Equation 3-1)
where:
I = percent increase in floor surface area.
FSA P = floor surface area proposed upon completion.
FSA R = floor surface area to remain after removals.
302.7.2.1 Chapters 8, 9 and 11.
Where a Level 1 alteration, Level 2 alteration or addition made to an existing building results in an increase in floor surface area of more than 110 percent, such building shall comply with Section 302.7.
302.7.3 Changes in scope of work.
In cases where changes in the scope of work during the course of construction would result in increasing the floor surface area at the completion of construction by more than 110 percent over the amount of existing floor surface area as determined pursuant to Section 302.7, such entire building shall be made to comply with the provisions of the New York City Building Code as if hereafter erected and such work shall be refiled in accordance with Section 28-105.2 of the Administrative Code.
302.7.4 Definitions.
The following term shall have the following meaning unless the context or subject matter requires otherwise:
FLOOR SURFACE AREA. For the purpose of calculating floor surface area in accordance with Section 302.7, floor surface area is the gross square foot area of all floor and roof surfaces, including roofs of bulkheads and superstructures, of a building or structure at any level, including cellar, attic and roof. Where such surfaces are sloped, the measurement shall be the horizontal projected area thereof.
302.7.5 Effect on zoning resolution.
The provisions of Section 302.7 shall not be construed to affect the status of any nonconforming use or non-complying bulk otherwise permitted to be retained pursuant to the New York City Zoning Resolution.
302.8 Applicability of previous codes.
Codes in effect prior to November 7, 2022, shall not apply to work on an existing building filed after the effective date of this code.
Exceptions:
1. Existing conditions. The provisions of codes in effect prior to November 7, 2022, remain applicable to the extent they establish the lawful existing conditions of a building, and such provisions remain enforceable by the department. Any alteration to change such existing conditions shall be in accordance with a lawful permit issued by the department to alter the building in accordance with this code.
2. Retroactive provisions of the 1968 building code. Retroactive provisions of the 1968 building code remain applicable to existing prior code buildings and enforceable by the department.
302.9 Mechanical, fuel gas, plumbing and fire protection systems.
Except as permitted by this code, alterations, additions or repairs to installations of mechanical, fuel gas, plumbing or fire protection systems shall conform to the requirements for new construction without requiring the existing installation to comply with all of the requirements of the New York City Construction Codes applicable to new systems. Alterations, additions, or repairs shall not cause an existing installation to become unsafe, hazardous, or overloaded.
302.9.1 Minor additions, alterations, renovations and repairs.
Except as permitted by this code, minor additions, alterations, renovations and repairs to existing installations of mechanical, fuel gas, plumbing and fire protection systems shall meet the provisions for new construction, unless such work is done in the same manner and arrangement as was in the existing system, is not hazardous and is approved.
302.9.2 Maintenance.
Installations of mechanical, fuel gas, plumbing and fire protection systems or parts thereof shall be maintained in proper operating condition in accordance with the original design and in a safe and sanitary condition. Devices or safeguards that are required by the New York City Construction Codes shall be maintained in compliance with the applicable provisions under which they were installed.
302.9.3 Compliance with structural requirements.
Installations of mechanical, fuel gas, plumbing, and fire protection systems and parts thereof shall comply with Section 307.2.
302.9.4 Required insulation of certain concealed piping exposed during alteration or repair.
Where concealed existing piping is exposed in the course of the alteration or repair of a building, the owner of the building shall provide for the insulation of the exposed piping. The exposed piping shall be insulated to the extent required by the New York City Energy Conservation Code for newly installed pipe of the same specifications and serving the same function as the exposed pipe. The entire exposed length of the piping shall be insulated as well as any further length of concealed pipe that can be directly accessed through openings made in the course of such alteration or repair.
Exceptions:
1. Exposed pipe with one-inch (25-mm) thick continuous coverage of existing insulation in good condition.
2. Where the length of concealed pipe which may be directly accessed through openings made in the course of such alteration or repair is less than 3 feet (914 mm).
3. Where there is not sufficient space to insulate pipes to the extent required by the New York City Energy Conservation Code due to conflicts with existing construction, pipes shall be insulated to the extent that space allows.
302.9.5 Work that increases sanitary or stormwater load.
Work that increases either the sanitary load or stormwater discharge of a plumbing system shall comply with Sections 310.8 and 310.9 of this code.
302.10 Flood hazard areas.
Alterations, additions, changes of occupancy and relocation, moving or raising of existing buildings in flood hazard areas shall comply with the requirements of Appendix G of the New York City Building Code to the extent required therein.
302.10.1 Flood hardening.
Work performed for the purposes of flood hardening shall comply with Appendix G of the New York City Building Code.
302.11 Special inspections.
Work subject to special inspection shall comply with the applicable provisions of Chapter 17 of the New York City Building Code.
Section EBC 303. Building Elements and Special Construction
303.1 General.
The addition to, installation and replacement of building elements shall comply with the applicable provisions of the New York City Building Code for new construction and Sections 303.2 through 303.10 of this code.
303.2 Fire resistive elements.
The fire-resistance ratings of existing building elements and materials shall not be reduced.
Exception: Where the building is fully sprinklered, the fire-resistance ratings of building elements may be modified to meet the fire-resistance rating requirements of the New York City Building Code provided that equivalent fire protection is maintained. The registered design professional of record shall demonstrate that:
1. The building elements subject to the fire resistance rating modification comply with the applicable provisions of Chapters 7 and 10 of the New York City Building Code including protection of openings thereto.
2. The installation of sprinkler system was not and will not be used to compensate for any non-compliant condition.
303.3 Roof recovering and replacements.
In existing buildings, roof recovering and replacement shall comply with Chapter 15 of the New York City Building Code and Sections 303.3.1 through 303.3.5 of this code.
303.3.1 Installation and materials.
Work involving the recovering or replacing of an existing roof covering shall be governed by Section 1511 of the New York City Building Code.
303.3.2 Cool roofs.
Work involving the recovering or replacing of an existing roof covering shall be permitted to be performed in accordance with the solar reflectance requirements in Chapter 15 of the New York City Building Code.
303.3.3 Vegetative roofs, roof gardens and landscaped roofs.
Work involving vegetative roofs, roof gardens and landscaped roofs shall be permitted to be performed pursuant to Chapter 15 of the New York City Building Code.
303.3.4 Solar photovoltaic panels/modules.
Work involving the installation or alteration of solar photovoltaic panels/modules shall be performed in accordance with the solar reflectance requirements in Chapter 15 of the New York City Building Code.
303.3.5 Sustainable roofing zones.
Work involving the replacing of an entire existing roof deck or roof assembly shall be permitted to be performed in accordance with Chapter 15 of the New York City Building Code.
303.4 Chimneys and vents.
Chimneys and vents shall be constructed in accordance with Chapter 21 of the New York City Building Code, Chapter 8 of the New York City Mechanical Code, or Chapter 5 of the New York City Fuel Gas Code, as applicable.
303.4.1 Responsibility of owner of taller building.
Whenever a building is erected, enlarged, or increased in height so that any portion of such building, except chimneys or vents, extends higher than the top of any previously constructed chimneys or vents within 100 feet (30 m), the owner of such new or altered building shall alter such chimneys or vents in accordance with the requirements of Chapter 21 of the New York City Building Code, Chapter 8 of the New York City Mechanical Code, or Chapter 5 of the New York City Fuel Gas Code, as applicable.
303.5 Mold resistance.
Alterations, repairs, additions and relocations of buildings shall comply with Sections 2506 and 2509 of the New York City Building Code relating to areas subject to moisture or water damage.
303.6 Interior environment.
Alterations, additions, conversions and changes of use or occupancy shall comply with Chapter 12 of the New York City Building Code and this code. Occupancy Groups I-1, R-1 and R-2 shall also comply with Appendix D of this code.
303.7 Window guards.
Where the alteration of a Group R-2 building includes the repair or replacement of windows, the replacement windows shall be subject to applicable requirements of the New York City Department of Health and Mental Hygiene with regard to window guards.
303.8 Emergency escape and rescue openings.
Replacement windows in sleeping rooms located below the 4th story and in below-grade stories shall comply with the requirements of Section 1030 of the New York City Building Code.
Exception: Replacement windows that are the manufacturer’s largest standard size window that will fit within the existing frame or existing rough opening shall be permitted to be of the same operating style as the existing window or a style that provides for an equal or greater window opening area than the existing window.
303.9 Special construction.
Special building construction, including but not limited to membrane structures, temporary structures, pedestrian walkways and tunnels, automatic vehicular gates, awnings, canopies, sun control devices, marquees, signs, telecommunications towers and antennas, swimming pools and enclosures, sidewalk cafés, and fences, that is part of an alteration of or addition to an existing building shall comply with the provisions of Chapter 31 of the New York City Building Code.
303.10 Exterior glazing.
Where the alteration of a building includes the replacement of all exterior glazing, such alteration shall comply with Section 1403.8 of the New York City Building Code.
Section EBC 304. Fire Protection
304.1 Fire protection systems.
Except as otherwise provided by this section, alterations, repairs, changes of occupancy, and additions made to existing buildings and systems shall be governed by Chapter 9 of the New York City Building Code and this code.
304.1.1 Additions, alterations or repairs of existing systems.
Additions, alterations or repairs of existing fire protection systems shall conform with Section 804 or Sections 505 and 506, as applicable for limited sprinkler and standpipe alterations.
304.1.2 Requirements based on change of occupancy or use.
Fire protection systems shall be provided for the space or building subject to change of occupancy or use in accordance with Section 1004.
304.1.3 Requirements for building additions.
Fire protection systems shall be provided for the addition or the entire building in accordance with Section 1104.
304.1.4 Requirements based on level of alterations.
Fire protection systems shall be provided to buildings and spaces based on the level of alteration in accordance with the provisions of Sections 804 and 904 of this code.
304.2 Painting requirements for sprinkler systems.
Sprinkler systems shall be painted in accordance with Sections 304.2.1 through 304.2.3.
Exception: Where otherwise not required by Section 903.6 of the New York City Building Code.
304.2.1 Alterations.
Cross connections and risers for independent (stand-alone) existing sprinkler systems that are exposed during alterations shall be painted red and the handles of valves serving such existing sprinkler systems shall be painted green. Where the alteration requires a hydrostatic pressure test, such painting shall be completed prior to such test.
304.2.2 Combination standpipe and sprinkler systems.
Where a standpipe system is used as a combination standpipe and sprinkler system, the sprinkler risers and cross connections that are also used for the standpipe system shall be painted red and the handles of valves serving such combination system shall be painted yellow.
304.2.3 Certification of completion of system painting.
For all buildings where sprinkler and combination sprinkler and standpipe systems are not subject to a special inspection pursuant to Chapter 17 of the New York City Building Code, a licensed master plumber, licensed master fire suppression piping contractor, registered design professional or an individual holding an appropriate certificate of fitness from the Fire Department for the operation and/or maintenance of such system shall certify on forms provided by the Department that all required painting has been completed in accordance with Section 304.2. Such certification shall be maintained on the premises and made available for inspection by the Department and the Fire Department.
304.3 Painting requirements for standpipe systems.
The painting requirements for standpipe systems shall be in accordance with Sections 304.3.1 through 304.3.3.
Exception: Where otherwise not required by Section 905.11 of the New York City Building Code.
304.3.1 Alterations.
Existing handles of valves serving existing standpipe systems and existing unpainted standpipe risers that are exposed during alterations shall be painted red. Where the alteration requires a hydrostatic pressure test, such painting shall be completed prior to such test.
304.3.2 Combination standpipe and sprinkler systems.
Where a standpipe system that is used as a combination standpipe and sprinkler system is required to be painted, the sprinkler risers and cross connections that are also used for the standpipe system shall be painted red, and the handles of valves serving such combination standpipe and sprinkler system shall be painted yellow.
304.3.3 Certification of completion of system painting.
For all buildings where standpipe and combination sprinkler and standpipe systems are not subject to a special inspection pursuant to Chapter 17 of the New York City Building Code, a licensed master plumber, licensed master fire suppression piping contractor, registered design professional or an individual holding an appropriate certificate of fitness from the Fire Department for the operation and/or maintenance of such system shall certify on forms provided by the Department that all required painting has been completed in accordance with Section 304.3. Such certification shall be maintained on the premises and made available for inspection by the Department and the Fire Department.
304.4 Fire Department connections.
Wherever the Fire Department connection is not visible to approaching fire apparatus, the Fire Department connection shall be indicated by an approved sign mounted on the street front or on the side of the building. Such sign shall have the letters “FDC” not less than 6 inches (152 mm) high and words in letters not less than 2 inches (51 mm) high or an arrow to indicate the location. Such signs shall be subject to the approval of the Fire Department.
Section EBC 305. Means of Egress
305.1 General.
Alterations, repairs, additions, changes of occupancy or relocations of existing buildings that require changes to means of egress shall be subject to the applicable provisions of Chapters 8 through 11, Chapter 14 and this section.
305.2 Minimum requirements.
It shall be unlawful to alter a building in a manner that will reduce the number of exits or the capacity of the means of egress to less than required by Chapter 10 of the New York City Building Code and this code.
305.3 Maintenance.
Means of egress shall be maintained in accordance with the New York City Fire Code.
305.3.1 Workplace exits.
Except as specifically provided for in Chapter 10 of the New York City Building Code, no employer or agent of an employer shall lock the doors of or otherwise prohibit exit from any workplace, when by so doing the health or safety of any employee, independent contractor or other individual working in such workplace may become endangered by fire or other hazardous condition. Refer to Section 118.2.7.
305.4 Inadequate exits for existing structures.
An existing structure that is not provided with means of egress as required by Chapter 10 of the New York City Building Code and this code, and in which the means of egress are, in the opinion of the commissioner, inadequate for the safety of the occupants, shall be provided with means of egress or fire protection as directed by the commissioner.
305.5 Special provisions for prior code buildings.
Alterations, additions, changes of occupancy or relocations of prior code buildings that require changes to means of egress shall be permitted to comply with Sections 305.5.1 through 305.5.19 of this code. Other means of egress components that are not addressed in Sections 305.5.1 through 305.5.19 or in Sections 805, 905, 1005 or 1105 shall comply with Chapter 10 of the New York City Building Code.
Exception. Prior code buildings or spaces that are required by this code to provide means of egress in accordance with Chapter 10 of the New York City Building Code as new construction.
305.5.1 Occupant load and exit capacity.
The occupant load and exit capacity of prior code buildings or spaces shall be determined in accordance with Chapter 10 of the New York City Building Code.
Exception: The following alterations shall not be required to determine a new occupant load in accordance with Chapter 10 of the New York City Building Code and shall be permitted to maintain the existing means of egress that complies with the code under which the building was constructed:
1. Level 1 alterations that maintain existing occupant loads as documented by an existing certificate of occupancy or existing approved plans.
2. Level 2 alterations in buildings 2 stories or less in height, with not more than 1 cellar, and an area of 10,000 square feet or less per story, that maintain existing occupant loads as documented by an existing certificate of occupancy or existing approved plans.
305.5.2 Accessible means of egress.
Accessible means of egress are not required in prior code buildings where the level of alterations does not trigger full building compliance with the accessibility provisions of the New York City Building Code.
305.5.3 Remoteness.
Alterations that result in the same or a lesser hazard occupancy category as described in Section 1005 may maintain the existing remoteness of exits. However, the remoteness of relocated or added exits shall comply with Chapter 10, and Chapter 4 where applicable to high-rise buildings, of the New York City Building Code.
305.5.4 Travel distance.
The maximum travel distance measured from the most remote point within a story along the natural and unobstructed path of egress travel to an exterior exit door at the level of exit discharge, an entrance to an interior exit stairway, interior exit ramp, exit passageway, horizontal exit, exterior exit stairway, or exterior exit ramp shall not exceed the limits specified in Chapter 10 of the New York City Building Code.
Exceptions:
1. Travel distances from Occupancy Groups F and S shall comply with Table 305.5.4(1).
2. Travel distances within Occupancy Group A shall comply with Table 305.5.4(2).
Table 305.5.4(1) Travel Distances for F and S Occupancies
Occupancy group of building or space Maximum Travel Distance (feet) Unsprinklered Sprinklered Factory F-1 125 175 F-2 150 200 Storage S-1 100 150 S-2 125 175
For SI: 1 foot = 304.8 mm
Table 305.5.4(2) Maximum Travel Distance Within Assembly Space (ft) a
Occupancy group of building or space Primary Secondary A-1 b 100 125 A-2 85 d 125 d A-3 c 100 d 125 d A-4 c 100 125 A-5 175 250
For SI: 1 foot = 304.8 mm
a. Where an assembly space is provided with an exit access doorway that opens directly to a safe area in accordance with Chapter 10 of the New York City Building Code , the primary and secondary travel distances shall be permitted to be measured to such exit access doorway. The travel distance from such safe area shall be in accordance with this section based on the occupancy classification of the main occupancy of the building or portion thereof to which the assembly space is ancillary to. When an exit opening from an assembly space discharges into another space, including a corridor, that does not meet the requirements of Chapter 10 of the New York City Building Code for a safe area, the travel distance shall include the distance within the space or corridor to an exit.
b. Required exits from stage shall be within a travel distance limitation of 125 feet.
c. Required exits from stage shall be within a travel distance limitation of 150 feet.
d. Where a Place of Assembly is completely equipped with automatic sprinkler system, this distance may be increased 50 percent.
305.5.5 Means of egress doors.
Repairs, alterations to and replacement of existing means of egress doors shall not reduce the fire resistance rating or dimensions of existing doors.
305.5.6 Alteration of corridors.
Alterations to corridors shall comply with Section 805 of this code and Section 28-307.2 of the Administrative Code.
305.5.7 Dead end corridors.
Dead end corridors in work areas shall comply with Section 805.
305.5.8 Existing smoke-stop doors in corridors.
Existing smoke-stop doors in corridors shall be maintained in corridors exceeding 300 feet (91 m) in length for Occupancy Group E, and 150 feet (46 m) in length for Occupancy Groups I-1, I-2, R-1 and R-2.
Exception. Smoke-stop doors may be eliminated in existing buildings provided with fire protection systems in accordance with Chapter 9 of the New York City Building Code. This exception does not apply to smoke-stop doors at elevator lobbies.
305.5.9 Exit passageways.
Alterations to exit passageways shall comply with Chapter 10 of the New York City Building Code. Not more than 50 percent of the total number of vertical exits provided for a building may be served by a single exit passageway, except as provided for in Section 305.5.10. No openings other than exit doors shall be permitted in exit passageways, except as permitted by Section 305.5.10.
305.5.10 Street floor lobbies.
The alteration of existing street floor lobbies serving as exit passageways in prior code buildings shall comply with the following provisions:
1. 100 percent of the total number of vertical exits provided in a prior code building may be served by an existing street floor lobby, if egress continues to be provided in 2 different directions from the discharge points of all vertical exits to open exterior spaces that are remote from each other.
2. Street floor lobbies shall be sized to accommodate the existing and new occupant load and egress capacity of all stairs and communicating spaces on the lobby floor that exit through them. Street floor lobbies shall not be decreased in width.
3. Openings between street floor lobbies, and elevators or communicating spaces, shall comply with the requirements of Chapter 10 of the New York City Building Code for protected areas.
Exceptions to Item 3:
1. Existing openings that open into an existing street floor lobby may be modified provided that the required fire-resistance ratings of such openings are not reduced and the total percentage of the linear length of such openings along the street floor lobby perimeter do not increase.
2. Existing show windows may be modified provided that the existing required fire-resistance ratings of display area enclosures are not reduced and the square footage of such enclosures within the street floor lobby do not increase.
3. The occupancy group of communicating spaces with openings into an existing street floor lobby may be changed to any other occupancy group within relative hazard category 3 as listed in Table 1005.2.
305.5.11 Stairs.
New or relocated stairs shall comply with Chapter 10 of the New York City Building Code unless otherwise provided for in this code. Alteration or vertical extension of existing stairs shall comply with Section 305.5.11.1 of this code.
Exception: The requirements for smoke proof enclosures and pressurization of stairways in Chapter 10 of the New York City Building Code shall not apply unless the building is required to comply with the provisions of this code as if it were a new building hereafter erected.
305.5.11.1 Stair width.
The width of existing stairs shall be measured as the clear width between walls, grilles, guards, or newel posts. Stair stringers may project into the required width not more than 2 inches (51 mm) on each side of the stair. Alterations to existing stairs shall maintain a minimum width of 44 inches (1118 mm).
Exceptions:
1. Existing interior stairs may be not less than 36 inches (914 mm) wide when serving not more than 30 occupants per stair on any floor in buildings classified in Occupancy Groups R-1 and R-2, or where serving buildings classified in Occupancy Group R-3 and exceeding 4 stories in height, or when serving not more than 60 occupants per stair on any floor in buildings classified in Occupancy Groups B, F and S.
2. Existing interior stairs may be not less than 30 inches (762 mm) wide when serving mezzanines having an occupant load not exceeding 25 persons or when located in buildings classified in Occupancy Group R-3 not more than 3 stories in height. Existing interior stairs in 4 story buildings classified in Occupancy Group R-3 shall be a minimum of 33 inches (838 mm) in width.
3. Existing interior stairs in buildings or building sections having a building area of 4,000 square feet (371 m 2 ) or less, and occupancy above the first floor of 50 persons or less, shall be a minimum width of 36 inches (914 mm).
4. Means of egress serving technical production areas in connection with an assembly space shall comply with Chapter 4 of the New York City Building Code.
305.5.11.2 Riser height and tread depth.
Riser height and tread depth for new stairs and vertical extension of existing stairs shall comply with Chapter 10 of the New York City Building Code. Alteration or replacement within the same shaft made to existing stairs where the existing space and construction does not allow a reduction in pitch or slope shall be permitted to maintain the existing riser height and tread depth and shall comply with Table 305.5.11.2. Riser height and tread depth shall be constant from story to story.
Table 305.5.11.2 Maximum Riser Height and Minimum Tread Depth in Prior Code Buildings a
OCCUPANCY CLASSIFICATION OF BUILDING MAXIMUM RISER HEIGHT MINIMUM TREAD DEPTH b Group R-3 with closed risers 8-1/4” 9” plus 1-1/4” nosing Group R-3 with open risers 8-1/4” 9” plus 1/2” nosing Group R-2 limited to 3 dwelling units 8-1/4” 9” plus 1-1/4” nosing Group A c 7-1/2” 9-1/2” plus nosing Group I-2 7” 10” plus nosing All other occupancies d 7-3/4” 9-1/2” plus nosing
For SI: 1 inch = 25.4 mm
a. The sum of 2 risers plus 1 tread exclusive of nosing shall be not less than 24 inches (610 mm) nor more than 25-1/2 inches (648 mm).
b. Treads may be undercut a dimension equal to the nosing. A nosing shall not be required when the tread depth is 11” (279 mm) or deeper.
c. For Occupancy Group A, stepped aisles, stairs, and stairways within the Place of Assembly and special occupancy structures, refer to Section 305.5.18.
d. The proportions and dimension of risers and treads may be adjusted in Occupancy Group E to suit the age of occupants, subject to the approval of the commissioner.
305.5.12 Fire towers.
Balconies and vestibules of existing fire towers shall comply with the requirements of Sections 305.5.12.1 and 305.5.12.2 of this code and Section 28-307.3 of the Administrative Code.
305.5.12.1 Alterations to fire towers.
Installation of mechanical equipment, piping, and electrical conduit other than for the purpose of serving the fire tower is prohibited. Where smokeproof enclosures would be required pursuant to Sections 403 or 405 of the New York City Building Code for new construction, existing fire towers shall not be altered to violate such requirements.
305.5.13 Handrails.
Where handrails are altered or added, they shall comply with Chapter 10 of the New York City Building Code.
Exception: Handrails shall not be required to comply with Section 1014.6 of the New York City Building Code regarding full extensions of the handrails where such extensions would be hazardous because of plan configuration.
305.5.14 Security grilles.
The installation and replacement of security grilles shall comply with Chapter 10 of the New York City Building Code.
305.5.15 Guards.
Where the alteration or repair of a building involves the addition or replacement of guards, such guards shall comply with Chapters10 and 16 of the New York City Building Code .
305.5.16 Fire escapes.
New fire escapes shall not be installed except as permitted by this section.
Exceptions:
1. Fire escapes for Occupancy Group R-2 buildings as permitted by Appendix D of this code.
2. Fire escapes for Occupancy Groups B, F or M buildings constructed prior to December 6, 1968 as permitted by the commissioner.
3. Prior code group homes constructed after December 6, 1968.
Existing fire escapes shall be permitted to remain provided they are properly maintained in a safe and code compliant condition.
305.5.16.1 Fire escape details.
Repairs, alterations to, replacement of existing and construction of new fire escapes shall comply with this section, except as provided for in Appendix D for residential fire escapes in multiple dwellings. Fire escapes constructed, repaired, altered, or replaced shall comply with rules of the Department and the following requirements:
1. Height limitations. No fire escape shall be permitted on buildings exceeding 6 stories or 75 feet (23 m) in height.
2. Capacity. The fire escape shall not serve more than 50 percent of the occupant load of the area or floor served.
Exception. Fire escapes shall not serve new or existing Group A occupancies exceeding 74 persons.
3. Stairs. The minimum width of fire escape stairs shall be 22 inches (559 mm). Treads shall have a minimum depth of 8 inches (203 mm), exclusive of a required 1 inch (25 mm) nosing. The maximum height of risers shall be 8 inches (203 mm). No flight of stairs shall exceed 12 feet (4 m) in height between landings and every new stair shall be placed at an angle of 45 degrees or less.
4. Landings. Landings shall be provided at each story served by fire escapes. The minimum width of landings shall be 3 feet (914 mm), and the minimum length shall be 4 feet 6 inches (1372 mm). Floor openings in landings shall be at least 22 inches (559 mm) by 28 inches (711 mm).
5. Handrails and guards. Handrails having a minimum height of 32 inches (813 mm) above the tread nosing shall be provided on both sides of stairs, and guards having a minimum height of 36 inches (914 mm) shall be provided on all open sides of stairs and landings. Openings in guards shall be of such dimensions as to prevent the passage of a 4 inch diameter ball (102 mm).
6. Construction. Fire escapes shall be constructed of noncombustible materials adequately protected against deterioration by corrosion or other effects of exposure to the weather and shall be designed to comply with the requirements of Chapter 16 of the New York City Building Code.
7. Access. Access to fire escapes shall be by doors or windows having a minimum clear opening of 24 inches (610 mm) in width and 30 inches (762 mm) in height. Such doors or windows shall have a fire protection rating of three-quarters of an hour.
8. Discharge. The top landing of fire escapes shall be provided with a stair or gooseneck ladder leading to the roof, except that this requirement shall not apply to buildings having a roof pitch of more than 20 degrees. The lowest landing of fire escapes shall be not more than 16 feet (5 m) above grade and shall be provided with a stair to grade, which may be counterbalanced. Where the fire escape is erected on a building wall other than the street wall, discharge to the street shall be provided through a fireproof passageway leading directly to the street.
9. Removal of fire escapes. Existing fire escapes serving as second means of egress shall not be removed unless an approved second means of egress is provided in compliance with the New York City Building Code, or where permitted by Appendix D of this code.
305.5.17 Escalators.
In prior code buildings, an existing escalator previously approved for use as a means of egress component shall be permitted to continue to be used as a means of egress component in lieu of interior stairs. Alterations or relocations of such escalators shall be subject to the requirements of Sections 305.5.17.1 through 305.5.17.4. Where an altered or relocated escalator does not meet the requirements of those sections, an additional stairway or stairways complying with Chapter 10 of the New York City Building Code shall be provided. New, relocated, or existing escalators not previously approved for such use, shall not be used as a means of egress component.
305.5.17.1 Capacity and width.
Such escalator shall not serve more than 50 percent of the required egress capacity for each story served. The egress capacity of such escalator shall be calculated at 0.3 inches (7.62 mm) of tread width per occupant. The minimum tread width of such escalator shall be 40 inches (1016 mm).
305.5.17.2 Sprinkler system.
Such buildings shall be equipped throughout with an automatic sprinkler system in accordance with Chapter 9 of the New York City Building Code.
305.5.17.3 Enclosure.
Such escalator shall be enclosed in accordance with Chapter 10 of the New York City Building Code as required for interior exit stairways.
305.5.17.4 Operation.
Such escalator shall be connected to a fire alarm system at all stories served, so that activation of the fire alarm system shall cause the escalator to gradually stop operating.
305.5.18 Places of Assembly.
Places of Assembly in existing buildings shall comply with Sections 305.5.18.1 through 305.5.18.3.
305.5.18.1 Existing Places of Assembly.
Alterations, changes of occupancy or additions made to existing Places of Assembly shall comply with Chapters 3, 8, 9, 10 and 11, as applicable.
305.5.18.1.1 Work limited to change in seating arrangements, stages and platforms.
Where the work within an existing approved Place of Assembly space is limited to modifications of stages, platforms, and seating arrangements, including moveable and fixed seating, seating support structures, bleachers, grandstands, folding and telescopic seating, such work shall be deemed a Level 1 alteration regardless of the size of the work area. Such work shall comply with the following conditions:
1. The work shall be performed in compliance with Sections 410 and 1029 of the New York City Building Code, as applicable;
2. There is no change to use, occupancy, exits, or increase in the existing occupant load;
3. The work is not associated with any other alteration to the space or systems serving the space; and
4. Where the work results in a change to the approved Place of Assembly application or permit, such application shall be amended as required by Article 117 of Title 28 of the Administrative Code.
305.5.18.1.1.1 Compliance with Chapter 8.
Work described by Section 305.5.18.1.1 shall comply with the following provisions of Chapter 8 within the work area:
1. Section 803.4 (Interior finish).
2. Section 803.5 (Guards), limited to the assembly space.
3. Section 803.10 (Architectural investigation) limited to investigation of exits from the Place of Assembly.
4. Sections 805.7 (Means of Egress lighting), 805.8 (Exit signs) and 805.9 (Handrails).
5. Section 806 (Accessibility).
305.5.18.2 Existing special occupancy structures.
Existing motion picture theaters, theaters, concert halls, operas, and similar places of assembly accommodating more than 300 persons that were established under Article 13 of the 1938 Building Code, including those constructed prior to 1938, shall not be subject to the filing requirements for a place of assembly application and Place of Assembly Certificate of Operation set forth in Article 117 of Title 28 of the Administrative Code and Section 1029 of the New York City Building Code.
Current seating plans approved by the Department shall be posted in such Places of Assembly. Modifications to the existing seating arrangements or exit access shall require new seating plans to be approved by the Department.
Exception: Alterations to such existing special occupancy structures exceeding the limitations of Section 305.5.18.1.1 shall be subject to Chapter 10 of the New York City Building Code, and Chapters 8 and 9 of this code to the extent of the alteration, but shall be permitted to maintain the existing means of egress provided the egress capacity is sufficient for the occupant load in accordance with Chapter 10 of the New York City Building Code. In addition, such places of assembly shall be subject to the filing requirements for a place of assembly application and Place of Assembly Certificate of Operation set forth in Article 117 of Title 28 of the Administrative Code.
305.5.18.3 New Places of Assembly in existing buildings.
New Places of Assembly in existing buildings shall comply with Chapter 10 of this code and Sections 410 and 1029 of the New York City Building Code, as applicable, but shall be permitted to use the existing means of egress provided the egress capacity is sufficient for the occupant load in accordance with Chapter 10 of the New York City Building Code. The required capacity of a means of egress system shall not be diminished along the path of egress travel.
Such new Places of Assembly shall be subject to Article 117 of Title 28 of the Administrative Code, including the filing requirements of a Place of Assembly application and Place of Assembly Certificate of Operation.
305.5.19 Balconies.
In prior code residential buildings classified as Group R-2, existing balconies serving as a second means of egress from dwelling units shall be maintained in accordance with this section. New balconies in such buildings shall be permitted to serve as a second means of egress from dwelling units where permitted by this code. Such balconies shall comply with the following conditions:
1. Each balcony shall serve at least 2 dwelling units.
2. Each balcony shall be protected along its outer side by parapets or guards not less than 3 feet 6 inches (1066 mm) high. Openings in new guards or parapets shall not allow passage of a sphere 4 inches (102 mm) in diameter.
3. The balcony floor shall be solid and provided with drains to prevent the accumulation of water.
4. The dwelling units served by balconies shall be separated from each other by construction having at least a 2-hour fire-resistance rating. Such separation shall extend at least 3 feet (914 mm) beyond the outside face of the exterior wall of the building, although such projection may be reduced to 2 feet 6 inches (762 mm) provided that any window opening on each such balcony served by the fire separation shall be at least 2 inches (51 mm) from such fire separation for every 1 inch (25.4 mm) that such separation is less than 36 inches (914 mm). An opening at least 20 inches (508 mm) wide shall be provided between the end of this separation and the balcony parapet or guard, and the opening shall be maintained free and unobstructed for the full height of the balcony, except that privacy screens openable from either side shall be permitted in the opening.
5. Access from dwelling units to the balconies shall be through doors having glass panels at least 2 feet (610 mm) wide and 4 feet (1220 mm) high, without muntins, screens, or other obstructions to hinder entry by breaking the glass panels. The doors shall be lockable only from the inside by devices that can be easily released from the outside after breaking the glass. A combination lock or a lock required to be opened by a key, removable device, or tool shall not be permitted.
305.6 Means of egress illumination.
Where the alteration of a building or portion thereof includes modifications to the means of egress illumination, such illumination levels shall comply with Chapter 10 of the New York City Building Code.
305.6.1 Emergency lighting in Places of Assembly.
Existing emergency lighting installed in accordance with prior codes in Places of Assembly shall be maintained. Any modifications to such emergency lighting shall comply with Chapter 10 of the New York City Building Code.
305.7 Luminous egress path markings.
In a high-rise prior code building, where the level of alterations, additions, or change of occupancy trigger compliance with Section 905, 1005, or 1105 of this code, luminous egress path markings shall be provided in accordance with Chapter 10 of the New York City Building Code.
Exceptions:
1. Egress paths serving Group R-2 occupancies need not provide luminous egress path markings.
2. Where means of egress lighting upgrade is required in accordance with Section 905, and such means of egress contains existing photoluminescent exit path markings tested in laboratory conditions with 2 foot-candles (22 lux) of activating illumination, the illumination level shall not be less than 2 foot-candles (22 lux), unless replaced with luminous path markings that comply with Chapter 10 of the New York City Building Code.
3. Where an addition is subject to Section 1105 of this code, and the existing portion of the stairs contains existing photoluminescent exit path markings tested in laboratory conditions with 2 foot-candles (22 lux) of activating illumination, the illumination level shall not be less than 2 foot-candles (22 lux), unless replaced with luminous path markings that comply with Chapter 10 of the New York City Building Code.
305.8 Flood hazard areas.
In flood hazard areas, temporary flood shields shall be permitted in accordance with Appendix G of the New York City Building Code, and temporary stairs and ramps shall be permitted to provide ingress and egress in accordance with Appendix G of the New York City Building Code.
Section EBC 306. Accessibility
306.1 Compliance.
Alterations, including minor alterations, repairs excluding ordinary repairs, and alterations affecting an area containing a primary function, changes of use or occupancy, additions and relocation of existing buildings, shall comply with Chapter 11 of the New York City Building Code and this code.
Exceptions: The provisions of Chapter 11 of the New York City Building Code are not applicable to:
1. Group R-3 occupancies in buildings with first occupancy on or before March 13, 1991.
2. Group R-3 occupancies in buildings with first occupancy after March 13, 1991, that were originally constructed as a single structure with fewer than 4 dwelling or sleeping units.
306.1.1 Requirements based on the extent of alterations.
Accessible features and construction governed by Chapter 11 of the New York City Building Code shall be provided:
1. To the entire building undergoing alterations, as if the building were hereafter erected in accordance with Sections 302.7 or 906 as applicable; or
2. To the portion of the building being altered or repaired, excluding ordinary repairs, to the extent of the alteration, including minor alterations in accordance with Section 105, Chapter 5, Section 806 or Section 906, as applicable.
306.1.2 Alterations affecting an area containing a primary function.
Alterations affecting an area containing a primary function shall comply with Section 806.3.
306.1.3 Change in occupancy or how a space is used.
Accessibility in buildings or portions of buildings undergoing a change of occupancy or use, as described in Section 1001.3, shall comply with Section 1006.
306.1.4 Additions to existing buildings.
Additions to existing buildings shall comply with Section 1106.
306.2 Special accessibility provisions.
Existing buildings or spaces shall comply with the applicable requirements of Sections 119 and 306.2.1 through 306.2.6.
306.2.1 Directional signage.
Directional signage shall be provided in accordance with Section 1111.2 of the New York City Building Code.
306.2.2 Identifying signage.
Identifying accessibility signage shall be provided in accordance with Section 1111.1 of the New York City Building Code.
306.2.3 Other signs.
Signage indicating special accessibility provisions shall comply with Section 1111.3 of the New York City Building Code.
306.2.3.1 Prior code buildings with inaccessible entrances.
At prior code buildings with 1 or more inaccessible entrances, signage stating that a portable ramp is available, if provided by the building, shall be provided at each inaccessible building entrance and shall contain the phone number to request such ramp. The use of a portable ramp by any building must comply with all applicable laws and any such ramp shall comply with Section 405 (Ramps) of ICC A117.1, except to the extent the commissioner has waived a requirement pursuant to Section 28-313.3.1 of the Administrative Code. All signage posted pursuant to this section shall comply with Section 1111 of the New York City Building Code and be maintained in good condition. Nothing in this section shall be construed to authorize the provision of a portable ramp where such provision would not otherwise be lawful.
306.2.4 Limited Use Limited Application (LULA) elevators in existing buildings.
In existing buildings, LULA elevators shall comply with Section 408 (Limited-use / Limited-Application Elevators) of ICC A117.1 and with Part 5.2 of ASME A17.1, as modified by Appendix K of the New York City Building Code. LULA elevators shall be limited to a maximum rise of not more than 25 feet (7620 mm) and shall be permitted to be a part of the required accessible route as follows:
1. In spaces complying with Section 1109.7.1 of the New York City Building Code where a LULA is permitted in new construction;
2. Where the total floor area of the entire building is less than 10,000 square feet (929 m 2 ); or
3. Where it serves an individual occupancy of less than 10,000 square feet (929 m 2 ) in buildings of 10,000 square feet (929 m 2 ) or more.
306.2.5 Lifts in existing buildings.
In existing buildings, platform (wheelchair) lifts installed in accordance with Section 410 (Platform Lifts) of ICC A117.1, ASME A18.1, and Chapter 30 of the New York City Building Code, shall be permitted to be a part of the required accessible route.
306.3 Waiver of requirements.
The commissioner may waive the requirements of Chapter 11 of the New York City Building Code or the accessibility provisions of this code, for the alteration of existing buildings, provided that such waiver would not significantly adversely affect provisions for health, safety and security and that equally safe and proper alternatives are prescribed and, further, that such waiver is based upon a specific finding that strict compliance with the requirement:
1. Would create an undue economic burden;
2. Would not achieve its intended objective;
3. Would be technically infeasible or legally impossible;
4. Would be unnecessary in light of alternatives that ensure the achievement of the intended objective or which, without a loss in the level of safety, achieve the intended objective more efficiently, effectively or economically; or
5. Would entail a change so slight as to produce a negligible additional benefit consonant with the purposes of this chapter.
306.3.1 Application process.
Each application for a waiver shall be made to the commissioner in writing, setting forth each requirement sought to be waived and the specific reason or reasons for such waiver request. The commissioner shall determine, under all of the circumstances presented by such application, which of such requirements may appropriately be waived. The commissioner shall render such determination in writing, which shall set forth in detail, the commissioner’s findings and conclusions with respect to each requirement sought to be waived. A copy of such written determination shall be forwarded to the applicant. Such written determination shall be filed with the Department and shall be available for public inspection.
306.3.2 Waiver recommendation.
The Mayor’s Office for People with Disabilities or its successor agency shall be consulted by and shall advise the commissioner concerning each application for a waiver under Section 306.3.
306.4 Existing facilities.
The provisions of this code shall not impose a requirement for greater accessibility than that which would be required for new construction. No work made to existing facilities, including ordinary repairs, shall:
1. Cause existing accessible facilities to be reduced or diminished to less than those that would be required for new construction; and
2. Reduce or have the effect of reducing or diminishing the level of accessibility of a facility or portion of a facility.
Section EBC 307. Structural
307.1 General.
Repair, alteration, partial demolition, removal, change of occupancy, relocation, moving, raising of or additions to existing buildings shall be subject to the provisions of Chapter 7. The applicability of Chapter 7 shall not be limited only to planned structural work and shall include structural elements in need of repair discovered during the course of construction.
307.1.1 Condition assessment and remediation.
Where the scope of work triggers condition assessment or remediation work in accordance with Section 704 or 708, such assessment or remediation work shall be performed as required.
307.2 Non-structural building elements, equipment and systems.
The installation of non-structural building elements, systems and equipment shall be subject to Sections 307.2.1 and 307.2.2.
307.2.1 Seismic support.
In existing buildings of seismic design categories C and D as defined in the New York City Building Code, new building elements, equipment and systems shall be provided with seismic supports as required by Section 1613 of the New York City Building Code.
Exceptions :
1. One- and two-family dwellings 3 stories or less in height.
2. The seismic force-resisting systems of wood-frame buildings that conform to the provisions of Section 2308 are not required to be analyzed as specified in this section.
3. Agricultural storage structures intended only for incidental human occupancy.
4. Structures that require special consideration of their response characteristics and environment that are not addressed by this code or ASCE 7, as modified by the New York City Building Code, and for which other regulations provide seismic criteria, such as vehicular bridges, electrical transmission towers, hydraulic structures, buried utility lines and their appurtenances and nuclear reactors.
307.2.2 Wind resistance.
New building elements, equipment, appliances and supports that are exposed to wind shall be designed and installed to resist the wind pressures determined in accordance with Chapter 16 of the New York City Building Code.
307.2.3 Loading.
Modifications resulting in an increase in loads on a structural member shall not be permitted without prior verification that such member is capable of supporting such additional loads in accordance with Chapter 7.
Section EBC 308. Electrical
308.1 General.
Electrical work, installation of and work on emergency and standby power systems, and the increase in size of electrical service in alterations of parking garages and open parking lots shall be governed by the applicable provisions of the New York City Electrical Code, Chapter 27 of the New York City Building Code, this section, and the applicable provisions of Chapters 8, 9, 10 and 11 of this code.
308.2 Group A occupancies in prior code buildings.
Where a stationary generator is not otherwise required, the power source for emergency power to the voice/alarm communication system may be served by a gas generator or an uninterruptable power source (UPS) in accordance with the New York City Electrical Code.
308.3 Optional standby power systems in existing buildings.
The installation of optional standby power systems shall comply with Sections 308.3.1 and 308.3.2.
308.3.1 Required loads for optional standby systems.
Where an optional standby power system is installed in an existing building, it shall supply power to the loads listed under Section 2702.4 of the New York City Building Code. Such loads shall be connected to the optional standby power system unless such loads are already supplied by a functioning emergency power system or legally required standby system. All installations and connections shall be in accordance with the New York City Electrical Code. If an optional standby power system is used to supply required standby power loads, it shall comply with Section 2702.4.2 and 2702.4.3 of New York City Building Code. Natural gas from the public utility shall be permitted as the fuel supply for optional standby power systems if such optional standby power system is supplying only optional standby loads. If an optional standby power system is supplying emergency or standby loads, the natural gas supply shall be taken ahead of the main, provided that an outside gas cut-off valve is separate from other gas services installed in accordance with Section E.6 of Appendix E of the New York City Fuel Gas Code.
308.3.2 Additional optional standby power system.
Where a functioning emergency power system or required standby system is in place and provides power to all required emergency or required standby power loads, any additional optional standby power system installed need not supply power to such emergency or required standby power loads.
308.4 Emergency power requirements for fire pumps.
New or replacement fire pumps in existing buildings shall be connected to an emergency power system in accordance with Sections 308.4.1 and 308.4.2.
308.4.1 Existing buildings equipped with an emergency power system.
In an existing building equipped with an emergency power system, new or replacement fire pumps shall be connected to the emergency power system where Chapter 27 of the New York City Building Code requires fire pumps to be connected to the emergency power system.
308.4.2 Existing buildings not equipped with an emergency generator.
In an existing building that is not equipped with an emergency power system, but where fire pumps are required to be connected to an emergency power systems in accordance with Chapter 27 of the New York City Building Code, a new emergency power system shall be installed to supply power to the new fire pump.
Exception: A new emergency power system need not be installed where the scope of alteration does not involve a change in the main use or dominant occupancy of the building, provided that electrical power to the motor is taken ahead of the main from the street side of the house service switch, and
1. The scope of alteration does not include modifications to an existing fire pump; or
2. The scope of alteration includes the replacement of an existing fire pump with a new fire pump of the same or smaller capacity.
308.5 Parking garages and open parking lots.
Where an alteration of a parking garage or an open parking lot includes an increase in the size of the main electric service that serves such parking garage or open parking lot, such alteration shall include provisions for the installation of electric vehicle charging stations in accordance with Section 406 of the New York City Building Code, as applicable.
Section EBC 309. Mechanical
309.1 General.
In addition to the general requirements of Section 302.9, the installation of and work on existing mechanical systems including appliances, equipment, and components shall comply with the New York City Mechanical Code, this section, and the applicable provisions of Chapters 8, 9, 10 and 11 of this code.
309.2 Special provisions for prior code buildings.
In addition to the requirements of Section 302.9, the provisions of Sections 309.2.1 through 309.2.4 shall apply to prior code buildings.
309.2.1 Air duct and transfer openings.
In cases where the building’s passive fire-resistance protection design, including rated construction, corridors and fire separations, complies with prior codes, the air duct and transfer openings shall be protected based on the fire resistive rating of the assembly being penetrated, as required by prior code. Where a prior code building has been fully sprinkler protected, air duct and transfer opening protectives shall be provided in accordance with required fire-resistance ratings for assemblies as reduced in accordance with Section 303.2 of this code. Damper hour ratings and installation requirements shall comply with Section 607 of the New York City Mechanical Code.
309.2.2 Guards and access to roofs and elevated structures.
The provisions of Sections 304.11 and 306.5 of the New York City Mechanical Code relating to guards and to permanent means of access, respectively, shall not apply where new equipment or appliances replace existing equipment or appliances in the same location.
309.2.3 Vibration isolators for cooling towers.
Where an existing cooling tower is replaced and physical limitations prohibit compliance with the vibration isolator requirements of Section 313.3.7 of the New York City Mechanical Code, such isolators may be omitted. Such physical limitations must be verified by the registered design professional and included in construction documents, supported with field conditions, calculations and manufacturer specifications. The installations shall comply with all other requirements of the New York City Noise Control Code.
309.2.4 Noncombustible fill for cooling towers.
Where an existing exterior cooling tower with combustible fill, located within 15 feet (4572 mm) of the lot line is replaced, such replacement shall be permitted to have combustible fill, notwithstanding the provisions of Section 908.3.2 of the New York City Mechanical Code.
309.3 Boiler identification.
Where an existing boiler or burner is replaced, the appliance shall be identified with a nameplate permanently affixed to the appliance. Such nameplate(s) shall be securely attached to the front of the boiler or placed in a conspicuous location on the boiler. In no case shall these numbers or identification be removed until the boiler is permanently discontinued. No person, except a boiler inspector authorized by the department, or department inspector, shall be authorized to deface or remove any boiler identification number on a boiler.
Section EBC 310. Plumbing
310.1 General.
In addition to the general requirements of Section 302.9, alterations, additions or repairs of installations of plumbing systems shall conform to the requirements for new installations without requiring the existing installation to comply with all of the requirements of the New York City Plumbing Code, this section, and the applicable provisions of Chapters 8, 9, 10, and 11 of this code. Alterations, additions, or repairs shall not cause an existing installation to become unsafe, hazardous, or overloaded.
310.2 Plumbing fixtures.
The number of existing plumbing fixtures shall be increased where the alteration work results in an occupant load increase greater than 10 percent, when calculated in accordance with Chapter 10 of the New York City Building Code, and Section 403 of the New York City Plumbing Code requires the additional installation of more than 1 plumbing fixture.
310.3 Existing piping used for grounding.
Existing metallic water service piping used for electrical grounding shall not be replaced with nonmetallic pipe or tubing until other approved means of grounding is provided.
310.4 Rehabilitation of piping systems.
Cured in Place pipe (CIPP) and epoxy spray pipe lining systems shall not be used.
310.5 Reuse of piping.
Piping that has been utilized for any purpose other than conveying potable water shall not be utilized for conveying potable water.
310.6 Abandonment of existing building sewer connections.
All abandoned building sewers shall require plug permits from the Department of Environmental Protection and shall be securely sealed at a point inside the curb line and as close thereto as practicable.
310.7 Sanitary drainage.
Where an alteration or addition made to an existing building affects the sanitary drainage system, such work shall comply with the requirements of the Department of Environmental Protection, Chapter 7 of the New York City Plumbing Code and rules of the Department.
310.7.1 Individual private on-site sewage disposal system.
Installation, alteration, and maintenance of individual private on-site sewage disposal systems serving one- and two- family dwellings and nonresidential properties receiving less than 1,000 gallons of sewage per day shall be subject to New York City Plumbing Code and rules of the Department.
310.7.1.1 Expansion of existing septic systems.
Where an alteration is proposed that will result in an increase in the number of bedrooms in one- and two-family dwellings or the daily flow rate in all other properties, thereby increasing the load on the existing septic system, such alteration shall comply with rules of the Department.
310.7.1.2 Where public sewers are made available to premises with private sewage disposal system.
When public sewers are made available to premises with individual on- site private disposal systems, such private sewage disposal system shall be abandoned in a manner prescribed by the commissioner, and the owner shall connect the building house sewer to the available public sewer within 6 months of the date of notification that the sewer has been accepted to receive flow by the agency or agencies having jurisdiction.
310.8 Storm drainage.
Alterations of buildings proposing horizontal building enlargement or alterations that increase impervious surfaces on the tax lot shall comply with the applicable provisions of Chapter 11 the New York City Plumbing Code and the requirements of the Department of Environmental Protection.
310.8.1 Increases in existing impervious surfaces.
Whenever impervious surfaces on the lot are increased, such impervious surfaces shall drain into a storm sewer system, or a combined sewer system, or to an approved place of disposal in accordance with the New York City Plumbing Code and Section 106 of this code.
310.8.2 Private on-site stormwater disposal.
Installation of private on-site stormwater disposal shall comply with Section 1114 of the New York City Plumbing Code.
310.9 Secondary (emergency) roof drains.
Existing secondary (emergency) means of overflow shall not be removed or reduced in capacity. Where alterations are being made to existing roofs with existing storm drainage, the addition of secondary (emergency) drainage shall not be required where:
1. The alterations do not result in the addition of new perimeter construction where no such parapet or similar construction previously existed which extends above the roof in such a manner that water will be entrapped if the existing drains allow buildup for any reason;
2. The alterations do not increase the impervious area of the roof; or
3. The additional impervious area does not result in exceeding the existing flow of the storm drainage system, or portion thereof, when sized in accordance with Section 1106 of the New York City Plumbing Code.
Section EBC 311. Fuel Gas
311.1 General.
In addition to the general requirements of Section 302.9, the installation of and work on all fuel gas piping, appliances, equipment, and systems shall be governed by the applicable provisions of this code. All work not specifically addressed in this section shall be in accordance with the New York City Fuel Gas Code. The scope covered by this section includes piping systems from the point of delivery to the connections with the appliances and includes the design, materials, components, fabrication, assembly, installation, testing, inspection, operation and maintenance of such piping systems in existing buildings.
311.1.1 Meters and service piping.
Service piping includes the fuel-gas piping up to the point of delivery. Meters and service piping shall comply with the requirements of 16 NYCRR Part 255 and Appendix E of the New York City Fuel Gas Code. In addition, meters, regulators and service piping located within buildings shall be located in accordance with the structural integrity, firestopping, and fire protection provisions of this code.
311.1.2 Existing installations.
Except as otherwise provided for in this section or elsewhere in this code, a provision in this code shall not require the removal, alteration or abandonment of, nor prevent the continued utilization and maintenance of existing installations of fuel gas systems lawfully in existence on the effective date of this code.
311.2 Special provisions for prior code buildings.
Fuel gas piping work in prior code buildings shall comply with the requirements of this section. Where compliance with Sections 311.2.1 and 311.2.2 is not feasible, compliance with the New York City Fuel Gas Code is required.
311.2.1 Repair or replacement of existing fuel gas piping.
For prior code buildings, the repair or replacement of existing fuel gas piping located in existing public corridors, exit enclosures, interior stairways, fire-resistance-rated construction, or spaces containing fire pumps in the same location shall be permitted where the following conditions are met:
1. The piping system must have been shut down and locked by the utility in response to an emergency condition;
2. Minor deviation from the existing location is permissible within 5 feet from the original piping location;
3. When an existing gas piping system located within a space containing a fire pump is replaced, all piping must be separated from the space by an enclosure equivalent to the fire resistance and, where applicable, impact resistance requirements of the space in which the piping is located; and
4. The existing installation must have been constructed in accordance with the code requirements in effect at the time of the installation.
311.2.2 Alterations, additions and new fuel gas piping.
For prior code buildings, the alteration, addition or installation of new fuel gas piping in existing public corridors, exit enclosures, interior stairways, fire-resistance-rated construction, or spaces containing fire pumps shall be permitted where the following conditions are met:
1. New fuel gas piping located in exit enclosures, interior stairways, fire-resistance-rated construction, a space containing a fire pump, townhouses or within a public corridor above the lowest level or above the lowest residential level of a building must be separated from the space by an enclosure meeting the fire resistance rating and, where applicable, impact resistance requirements of the space in which the piping is located;
2. New fuel gas piping located in a public corridor at the lowest level or lowest residential level of a building shall not be required to be separated by an enclosure;
3. All new valves shall be accessible for maintenance and inspection; and
4. All new piping joints must be welded.
311.2.3 Guards and access to roofs and elevated structures.
The provisions of Sections 306.5 and 306.6 of the New York City Fuel Gas Code, relating to guards and permanent means of access, respectively, shall not apply where the equipment or appliances replace existing equipment or appliances in the same location.
311.2.4 Seismic supports.
For prior code buildings, the determination as to whether seismic design requirements shall apply to a repair or replacement shall be made in accordance with Section 307.
311.2.5 Wind resistance.
For prior code buildings, the determination as to whether wind pressure design requirements shall apply to a repair or replacement shall be made in accordance with Section 307.
311.2.6 Drips.
Existing drips on piping systems shall be permitted to remain.
Exception: An existing drip shall be removed when an alteration or repair connection is made at the drip.
311.2.7 Gas piping supplying domestic cooking appliances.
Existing 1/2 inch diameter piping supplying gas to a domestic cooking appliance shall be permitted to be utilized and remain, provided it has adequate capacity for all appliances served.
311.3 Gas piping in townhouses.
When originally constructed in accordance with the New York City Construction Codes in effect prior to October 1, 2014, gas piping downstream of the point of delivery and extending through a townhouse unit to serve another townhouse unit shall be permitted to remain. Alterations, repairs, replacements and new piping installations of such piping shall comply with this section.
311.3.1 Minor deviations.
Minor deviations from the existing installation location are permissible only to the extent of replacing existing piping within 5 feet from the original location.
311.3.2 Valves.
All valves shall be accessible for maintenance and inspection.
311.3.3 Joints.
All new joints located within the townhouse containing, but not served by such gas piping must be welded.
Exception: For the purpose of repairs and replacements, joints shall not be required to be welded.
311.4 Gas piping installations.
The installation of gas piping shall comply with Sections 311.4.1 through 311.4.3 of this code.
311.4.1 Identification.
All new gas piping installed in existing buildings and existing gas piping exposed during the course of work, when subject to testing, whether or not the piping is intended to be enclosed when construction is completed, shall be identified in accordance with Chapter 4 of the New York City Fuel Gas Code.
311.4.2 Prohibited locations.
Gas piping shall not be installed in locations prohibited by Section 404 of the New York City Fuel Gas Code.
Exception: In prior code buildings, existing gas piping and meters lawfully constructed in accordance with the prior codes that are not in compliance with Section 404 of the New York City Fuel Gas Code, shall be permitted to be altered, provided that the following conditions are met:
1. All gas valves shall be accessible for maintenance and inspection; and
2. Gas pressure shall not exceed 1/2 psi (14 inches w.c.).
311.4.3 Inspection and testing of piping.
Prior to acceptance and operation, all gas piping installations shall be inspected and pressure tested in accordance with Section 406 of the New York City Fuel Gas Code and this section to determine that the materials, design, fabrication and installation practices comply with the requirements of this section and the New York City Fuel Gas Code.
Section EBC 312. Elevators and Conveying Systems
312.1 General.
The installation of, alterations to and work on elevators, conveying systems, and amusement rides shall be governed by Chapter 30 and referenced standards as modified by Appendix K of the New York City Building Code, rules of the Department, and this code.
312.2 Existing elevators and conveying systems.
All existing and altered elevators and conveying systems shall comply with ASME A17.3, as modified by Appendix K, Chapter K3 of the New York City Building Code, and be maintained and periodically inspected and tested in accordance with Sections 118 and 119 of this code.
312.3 Change of use of an existing elevator.
Where an existing elevator is subject to a change in use, such change shall comply with Section 3001.4 of the New York City Building Code.
312.4 Existing shafts.
In prior code buildings, elevator cabs installed in existing shafts shall be permitted to be smaller than that required by Chapter 30 of the New York City Building Code, where necessary to fit in the existing shaft.
Exception: An existing elevator shaft shall be enlarged or a new elevator shaft shall be constructed to accommodate an elevator cab in compliance with Chapter 11 of the New York City Building Code where the entire building is required to be accessible pursuant to Sections 302.7, 906, 1006 or 1106 as applicable.
312.5 Signage.
When an existing or new passenger elevator is being serviced, repaired, inspected, tested, or is out of service, “CAUTION” sign tapes shall be provided in accordance with Section 3011.1 of the New York City Building Code.
312.6 Additional provisions for existing buildings.
Existing buildings shall also comply with Sections 312.6.1 through 312.6.6.
312.6.1 Removal of existing hoistway smoke venting.
Existing hoistway smoke venting may be eliminated when all of the following conditions are met:
1. The entire building is protected with a sprinkler system in accordance with the New York City Building Code;
2. Each elevator lobby and elevator machine room is provided with smoke detection that is connected to the building fire alarm system;
3. Any elevator cars within the existing hoistway where the venting is removed shall have emergency recall in accordance with the New York City Building Code; and
4. The elimination of the venting does not impede the elevator operation.
312.6.2 New hoistways serving an occupied floor more than 120 feet (36 576 mm) above the lowest level of Fire Department vehicle access.
Where 1 or more new hoistways serving an occupied floor more than 120 feet (36 576 mm) above the lowest level of Fire Department vehicle access are proposed in an existing building, at least 1 elevator serving the same stories penetrated by the new hoistway shall meet all the requirements of Section 3007 of the New York City Building Code as a fire service access elevator. Wires or cables that are located outside of the elevator hoistway shall be protected in the manner described in Section 3007.8.1 of the New York City Building Code.
Exceptions:
1. Where the existing building has an existing fire service access elevator meeting the requirements of Section 3007 of the New York City Building Code.
2. Where new hoistways are added in floors above the alternate level for Phase I and Phase II as defined in ASME A17.1, as amended by Appendix K of the New York City Building Code, the elevators are not required to meet the requirements of Section 3007 of the New York City Building Code.
312.6.3 Elevator car to accommodate ambulance stretcher.
Where 1 or more new hoistways are proposed in an existing prior code building with 5 or more stories above, or 4 or more stories below grade plane, or underground buildings described in Section 405.1 of the New York City Building Code, at least 1 elevator serving the same stories that are penetrated by the new hoistway shall meet the requirements of Section 3002.4.2 of the New York City Building Code.
312.6.4 Limited Use Limited Application (LULA) elevators in prior code buildings.
In prior code buildings, LULA elevators shall be limited in use as described in Section 306.2.4 with maximum rise of 25 feet (7.6 m), maximum capacity of 1400 pounds (635 Kg) and maximum speed of 30 feet/min (0.15 m/sec.). LULA elevators shall not be used for any other purpose that is not referenced in Chapter 30 of the New York City Building Code.
312.6.5 Connection to standby power.
Where 1 or more new hoistways are proposed in an existing prior code building identified in Section 3002.4.1 of the New York City Building Code, at least 1 elevator serving the same stories that are penetrated by the new hoistway shall be connected to a standby power source in accordance with Chapter 27 and Section 3003.1 of the New York City Building Code.
312.6.6 Connection with existing fire alarm.
In buildings with an existing fire alarm system, when existing elevators are being upgraded and such upgrades include the installation of a new operational controller, such elevators shall be connected to the fire alarm system in accordance with NFPA 72, as amended by Appendix Q of the New York City Building Code, as required by ASME A17.1, as amended by Appendix K of the New York City Building Code.
Section EBC 313. Energy Conservation
313.1 Energy efficiency.
All work related to energy efficiency shall be regulated by the New York City Energy Conservation Code and this code.
Section EBC 314. Multiple Dwellings
314.1 Applicability of the New York State Multiple Dwelling Law (MDL) and Appendix D.
Existing buildings classified in Occupancy Groups I-1, R-1 and R-2, containing 3 dwelling units or more shall be identified as multiple dwellings, subject to the MDL and Appendix D of this code. See Sections D101.1 and D102.
314.2 Definitions.
Terms unique to existing multiple dwellings as such terms are used in Appendix D shall have the meaning ascribed to them in Section D201 of this code.
314.3 Classification.
Existing multiple dwellings shall be classified in accordance with Section D103 of this code based on year constructed, year converted, terms of occupancy and applicability of other laws.
314.4 Compliance.
Alteration, repair, change of use or occupancy and additions to multiple dwellings shall comply with this code including Appendix D.
Section EBC 501. General
501.1 Scope.
The provisions of this chapter shall govern certain alterations made to building systems, elements or material that are limited in scope and or value, as set forth in the definition of limited alteration in Chapter 2, and are limited to work described in Sections 503 through 510. Such limited alterations shall comply with this chapter.
501.2 Applicant.
In accordance with Section 28-104.6 of the Administrative Code, the applicant for approval of construction documents for limited alterations may be other than a registered design professional.
501.3 Additional categories of limited alterations.
The commissioner may promulgate rules to identify additional work of limited scope or value that is subject to this chapter.