BetaNYCLaw Reader
Contents
  1. Home
  2. NYC Administrative Code
  3. Title 28
  4. Chapter 7
  5. Part 23 of 33
  6. Section BC 2506

NYC Administrative Code Section BC 2506 Gypsum Board and Gypsum Panel Product Materials

2506.1 General.

Gypsum board, gypsum panel products and accessories shall be identified by the manufacturer's designation to indicate compliance with the appropriate standards referenced in this section and stored to protect such materials from the weather.

2506.2 Standards.

Gypsum board and gypsum panel products shall conform to the appropriate standards listed in Table 2506.2 and Chapter 35 and, where required for fire protection, shall conform to the provisions of Chapter 7.

Table 2506.2 Gypsum Board and Gypsum Panel Products Materials and Accessories

Material Standard Abuse resistant non-decorated interior gypsum panel products and fiber-reinforced cement panels ASTM C 1629 Accessories for gypsum board ASTM C 1047 Adhesives for fastening gypsum wallboard ASTM C 557 Cold-formed steel studs and track, structural AISI S200 and ASTM C 955, Section 8 Cold-formed steel studs and track, nonstructural AISI S220 and ASTM C 645, Section 10 Elastomeric joint sealants ASTM C 920 Fiber-reinforced gypsum panels ASTM C 1278 Glass mat gypsum backing panel ASTM C 1178 Glass mat gypsum panel 5 ASTM C 1658 Glass mat gypsum substrate ASTM C 1177 Joint reinforcing tape and compound ASTM C 474; C 475 Nails for gypsum boards ASTM C 514, F 547, F 1667 Steel screws ASTM C 954; C 1002 Standard specification for gypsum board ASTM C 1396 Testing gypsum and gypsum products ASTM C 22; C 472; C 473

2506.2.1 Other materials.

Metal suspension systems for acoustical and lay-in panel ceilings shall conform with Section 808.1.

2506.3 Mold resistance.

Gypsum board or cement board, used in an assembly for the following areas, shall have a mold resistance rating of 10 in accordance with ASTM D 3273:

1. Interior faces of exterior walls of basements, cellars, and other below grade rooms.

2. Walls and ceilings of spaces containing condensers, water tanks, water pumps, and pressure reduction valves.

3. Walls and ceilings of laundry rooms.

4. Portions of walls within 2 feet (610 mm) of kitchen sinks to a height of 4 feet (1219 mm) above the floor.

5. Portions of walls within 2 feet (610 mm) of kitchen stoves to a height of 4 feet (1219 mm) above the floor.

6. Walls of bathrooms that are not solely water closet compartments, other than walls specifically required to be cement board.

7. Walls and ceilings in service sink closets.

8. Portions of walls within 2 feet (610 mm) of mop sinks or service sinks to a height of 4 feet (1219 mm) above the floor.

Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2014/013.