NYC Administrative Code Title 28, Chapter 7 New York City Building Code, part 29 of 33
Section BC 3502 to Section BC G106: 26 sections.
Section BC 3502. Standards
AA Aluminum Association 1525 Wilson Boulevard, Suite 600 Arlington, VA 22209 Standard reference number Title Referenced in code section number ADM—15 Aluminum Design Manual: Part 1—A Specification for Aluminum Structures 1604.3.5, 1705.33.1, 2002.1 ASM 35—00 Aluminum Sheet Metal Work in Building Construction (Fourth Edition) 2002.1
AAMA American Architectural Manufacturers Association 1827 Waldon Office Square, Suite 550 Schaumburg, IL 60173 Standard reference number Title Referenced in code section number 1402—09 Standard Specifications for Aluminum Siding, Soffit and Fascia 1404.5.1 AAMA/WDMA/CSA 101/I.S.2/A440—11 North American Fenestration Standard/Specifications for Windows, Doors and Skylights 1709.5.1, 2405.5
AASHTO American Association of State Highway and Transportation Officials 444 N Capitol Street NW, Suite 249 Washington, DC 20001 Standard reference number Title Referenced in code section number T318—15 Standard Method of Test for Water Content of Freshly Mixed Concrete Using Microwave Oven Drying 1905.6.2.1, 1905.6.3.6
ACI American Concrete Institute 38800 Country Club Drive Farmington Hills, MI 48331 Standard reference number Title Referenced in code section number 216.1—14 Code Requirements for Determining Fire Resistance of Concrete and Masonry Construction Assemblies Table 721.1(2), 722.1 301—10 Specification for Structural Concrete 1812.1.1, 1905.2.4, 1905.3.5.2, 1905.6.3.7 306R—10 Guide to Cold Weather Concreting Table 1904.4.2 318—14* * As modified in Section 1908 Building Code Requirements for Structural Concrete 406.7.3, 722.2.4.3, 1604.3.2, Table 1613.5, Table 1705.2, Table 1705.3, 1705.3.1, 1705.37, 1809.5.7.2, 1809.6, Table 1810.2.13, Table 1810.8, 1810.9.1.1, 1810.9.2, 1810.9.2.1, 1811.6.3.2, 1811.6.3.2.2, 1812.1.2.5.1, 1812.1.2.5.2, 1812.7.4.1, 1812.8.3, 1812.8.4, 1901.2, 1901.3, 1901.5, 1902.1, 1903.1, 1903.5, 1903.6, 1903.6.1, 1903.6.2, 1903.7, 1903.8, 1904.1, 1904.2, 1904.3, 1904.4, 1904.4.1, 1904.5, 1905.1, 1905.1.1, 1905.1.4, 1905.2, 1905.3, 1905.4, 1905.5, 1905.6, 1905.6.5.5, 1905.6.6, 1905.8.3, 1905.11.3, 1906.1, 1906.2, 1906.3, 1906.4, 1907.1, 1907.2, 1907.4.1, 1907.5.2.1, 1907.5.2.2, 1907.6, 1907.7.1, 1907.7.2, 1907.7.3, 1907.7.4, 1907.7.5, 1907.7.6, 1907.8, 1907.9, 1907.10, 1907.11, 1907.12, 1907.13, 1908.1, 1908.1.1, 1908.1.2, 1908.1.3, 1908.1.4, 1908.1.5, 1908.1.6, 1908.1.7, 1908.1.8, 1908.1.9, 1908.1.10, 1909.1, 1912.2, 1912.3.1, 2108.3, 2206.1, 2206.3, 3305.3.2 530—13 Building Code Requirements for Masonry Structures 1705.4.1, 1705.4.3 530.1—13 Specifications for Masonry Structures Table 1705.4.1, Table 1705.4.3, 2105.1
AISC American Institute of Steel Construction One East Wacker Drive, Suite 700 Chicago, IL 60601-18021 Standard reference number Title Referenced in code section number ANSI/AISC 303—16 Code of Standard Practice for Steel Buildings and Bridges 2203.1, 2205.3.1 ANSI/AISC 341—16 Seismic Provisions for Structural Steel Buildings 1705.2.4.1, 1705.2.4.2, 1705.2.5, 1705.2.5.2, 2205.2.1.1, 2205.2.1.2, 2205.2.2, 2206.2.1, 2206.3 ANSI/AISC 360—16 Specification for Structural Steel Buildings 722.5.2.2.1, 1604.3.3, Table 1705.2, 1705.2.3, Table 1810.8, 2203.2, 2205.1, 2205.1.1, 2205.2.1.1, 2205.3, 2205.3.2, 2205.3.3, 2206.1, 2206.3, 3305.2
AISI American Iron and Steel Institute 25 Massachusetts Avenue, NW Suite 800 Washington, DC 20001 Standard reference number Title Referenced in code section number AISI S100—16 North American Specification for the Design of Cold-formed Steel Structural Members 1908.1.5, 2203.1, 2203.2, 2210.1, 2210.2 AISI S220—15 North American Standard for Cold-formed Steel Framing-Nonstructural Members 2203.1, 2203.2, 2211.2, Table 2506.2, Table 2507.2 AISI S230—15 Standard for Cold-formed Steel Framing-Prescriptive Method for One- and Two-family Dwellings, 1609.1.1, 1609.1.1.1, 2211.1.2 AISI S240—15 North American Standard for Cold-Formed Steel Structural Framing, 2015 Table 1705.2.6, 2203.1, 2203.2, 2211.1, 2211.1.1.1, 2211.1.3.3, Table 2603.12.1, Table 2603.12.2 AISI S400—15/S1—16 North American Standard for Seismic Design of Cold-formed Steel Structural Systems, 2015, with Supplement 1, dated 2016 1604.3.3, Table 1613.5
AMCA Air Movement and Control Association International 30 West University Drive Arlington Heights, IL 60004 Standard reference number Title Referenced in code section number 540—13 Test Method for Louvers Impacted by Wind Borne Debris 1609.1.2.1
ANSI American National Standards Institute 25 West 43rd Street, Fourth Floor New York, NY 10036 Standard reference number Title Referenced in code section number A10.3—06* * As modified in Section 3311.4 Safety Requirements for Powder-actuated Fastening Systems 3311.3, 3311.4, 3311.4.1, 3311.4.2, 3311.4.3, 3311.4.4, 3311.4.5, 3311.4.6, 3311.4.7, 3311.4.8, 3311.4.9, 3311.4.10, 3311.4.11, 3311.4.12 A10.4—16 Safety Requirements for Personnel Hoists on Construction & Demolition Sites 3001.2, 3010.3 ANSI/ASSP A10.11—10* * As modified in Section 3308.6.2 Safety Requirements for Personnel and Debris Nets 202 (structural net), 3302.1, 3308.6.2, 3308.6.2.3, 3308.6.2.4, 3308.6.2.5, 3308.6.2.6, 3308.6.2.7, 3308.6.2.8, 3308.6.2.9, 3308.6.2.10, 3308.6.2.11, 3308.6.4 A13.1—2007 Scheme for the Identification of Piping Systems 415.11.6.5, 903.6, 905.11 A108.1A—99 Installation of Ceramic Tile in the Wet-set Method, with Portland Cement Mortar 2103.2.3 A108.1B—99 Installation of Ceramic Tile, quarry Tile on a Cured Portland Cement Mortar Setting Bed with Dry-set or Latex-Portland Mortar 2103.2.3 A108.4—99 Installation of Ceramic Tile with Organic Adhesives or Water-cleanable Tile-setting Epoxy Adhesive 2103.2.3.6 A108.5—99 Installation of Ceramic Tile with Dry-set Portland Cement Mortar or Latex-Portland Cement Mortar 2103.2.3.1, 2103.2.3.2 A108.6—99 Installation of Ceramic Tile with Chemical-resistant, Water Cleanable Tile-setting and -grouting Epoxy 2103.2.3.3 A108.8—99 Installation of Ceramic Tile with Chemical-resistant Furan Resin Mortar and Grout 2103.2.3.4 A108.9—99 Installation of Ceramic Tile with Modified Epoxy Emulsion Mortar/Grout 2103.2.3.5 A108.10—99 Installation of Grout in Tilework 2103.2.3.7 A118.1—16 American National Standard Specifications for Dry-set Portland Cement Mortar 2103.2.3.1 A118.3—13 American National Standard Specifications for Chemical-resistant, Water-cleanable Tile-setting and -grouting Epoxy and Water Cleanable Tile-setting Epoxy Adhesive 2103.2.3.3 A118.4—16 American National Standard Specifications for Latex-Portland Cement Mortar 2103.2.3.2, 2103.3.2.4 A118.5—99 American National Standard Specifications for Chemical Resistant Furan Mortar and Grouts for Tile Installation 2103.2.3.4 A118.6—10 American National Standard Specifications for Cement Grouts for Tile Installation 2103.2.3.7 A118.8—99 American National Standard Specifications for Modified Epoxy Emulsion Mortar/Grout 2103.2.3.5 A136.1—08 American National Standard Specifications for Organic Adhesives for Installation of Ceramic Tile 2103.2.3.6 A137.1—12 American National Standard Specifications for Ceramic Tile 202 (porcelain tile) A190.1—17 Standard for Wood Products - Structural Glued Laminated Timber 2303.1.3, 2306.1 A208.1—16 Particleboard 2303.1.8, 2303.1.8.1 E1.42—18 Entertainment Technology - Design, Installation, and Use of Orchestra Pit Lifts 3001.2 E1.46—18 Standard for the Prevention of Falls from Theatrical Stages and raised Performance Platforms 3001.2 Z97.1—14 Safety Glazing Materials Used in Buildings—Safety Performance Specifications and Methods of Test 2406.1.2, 2406.2, Table 2406.2(2), 2406.3.1, 2407.1, 2407.1.4.1, 2408.2.1, 2408.3, 2409.2, 2409.3, 2409.4.1 Z535.1—06 Safety Colors 1024.3.1, 1025.6.2 Z535.2—11 Environmental and Facility Safety Signs K1
APA APA-Engineered Wood Association 7011 South 19th Tacoma, WA 98466 Standard reference number Title Referenced in code section number ANSI/A 190.1—17 Standard for Wood Products - Structural Glued Laminated Timber 2303.1.3, 2306.1 ANSI/APA PRP 210—14 Standard for Performance-Rated Engineered Wood Siding 2303.1.5, 2304.7, 2306.3 ANSI/APA PRR 410—16 Standard for Performance-Rated Engineered Wood Rim Boards 2303.1.13 APA PDS—12 Panel Design Specification 2306.1 APA PDS Supplement 1—14 Design and Fabrication of Plywood Curved Panels 2306.1 APA PDS Supplement 2—14 Design and Fabrication of Plywood-lumber Beams 2306.1 APA PDS Supplement 3—14 Design and Fabrication of Plywood Stressed-skin Panels 2306.1 APA PDS Supplement 4—14 Design and Fabrication of Plywood Sandwich Panels 2306.1 APA PDS Supplement 5 —14 Design and Fabrication of All-plywood Beams 2306.1 ANSI/APA PRG 320—18 Standard for Performance-Rated Cross-Laminated Timber Table 1705.5.6, 2303.1.4 EWS R540—13 Builders Tips: Proper Storage and Handling of Glulam Beams 2306.1 EWS S475—16 Glued Laminated Beam Design Tables 2306.1 EWS S560—14 Technical Note: Field Notching and Drilling of Glued Laminated Timber Beams 2306.1 EWS T300—16 Glulam Connection Details 2306.1 EWS X440—08 Product Guide: Glulam 2306.1
API American Petroleum Institute 200 Massachusetts Avenue NW Suite 1100 Washington, DC 20001-5571 Standard reference number Title Referenced in code section number API Specification 5CT—2018 Casing and Tubing, 10th Ed, June 2018 1811.7.1.2 API Specification 5L—2018 Line Pipe 46th Ed, April 2018 1811.7.1.2 API Recommended Practice 13B-1—2019 Recommended Practice for Field Testing Water-based Drilling Fluids, 5th Ed, May 2019 1812.1.1.2.3
APSP The Association of Pool & Spa Professionals 2111 Eisenhower Avenue Alexandria, VA 22314 Standard reference number Title Referenced in code section number ANSI/APSP 7—06 Standard for Suction Entrapment Avoidance in Swimming Pools, Wading Pools, Spas, Hot Tubs and Catch Basins 3109.3.1.1
AREMA American Railway Engineering and Maintenance-of-Way Association 10003 Derekwood Lane, Suite 210 Lanham, Maryland 20706 Standard reference number Title Referenced in code section number AREMA—2020 Manual for Railway Engineering 1607.10.5
ASABE American Society of Agricultural and Biological Engineers 2950 Niles Road St. Joseph, MI 49085 Standard reference number Title Referenced in code section number EP 484.2 June 1998 (R2008) Diaphragm Design of Metal-clad, Wood-frame Rectangular Buildings 2306.1 EP 486.2 OCT 2012 Shallow-post Foundation Design 2306.1 EP 559.1 2016 Design Requirements and Bending Properties for Mechanically Laminated Wood Assemblies 2306.1
ASCE/SEI American Society of Civil Engineers Structural Engineering Institute 1801 Alexander Bell Drive Reston, VA 20191-4400 Standard reference number Title Referenced in code section number 5—13 Building Code Requirements for Masonry Structures 1405.6, 1405.6.2, 1405.10, 1705.4.1, Table 1705.4.1, 1705.4.3, Table 1705.4.3 6—13 Specification for Masonry Structures 1405.6.1, Table 1705.4.1, Table 1705.4.4, 2105.1 7—16* * As modified in Chapter 16 Minimum Design Loads and Associated Criteria for Buildings and Other Structures with Supplement No. 1 202 (floodproofing, dry; maximum considered earthquake geometric mean (MCEG) peak ground acceleration; risk-targeted maximum considered earthquake (MCER) ground motion response acceleration), 909.10.6, 1602.1, 1604.3, Table 1604.3, 1604.4, 1604.5, Table 1604.5, 1604.5.2, 1604.8.2, 1604.9, 1605.1, 1605.2.1, 1605.3.1, 1605.3.1.2, 1607.8.1, 1607.8.1.1, 1607.8.1.2, 1607.9, 1608.1, 1608.3, 1609.1.1, 1609.1.2, 1609.1.6.1, 1609.1.6.2, 1609.5.3, 1609.7.1, 1611.2, 1612.1, 1613.1, 1613.3.1, 1613.3.2, 1613.3.3, 1613.3.4.1, 1613.3.4.1.1, 1613.3.5, 1613.3.5.1, 1613.3.5.2, 1613.4, 1613.5, Table 1613.5, 1613.6, 1614.1, 1705.12, 1705.13, 1801.2.1, 1810.9.1.1, 1810.9.2.2, 1810.9.2.4, 1811.6.3.2.1, 1811.6.3.2.2, 1816.2.1, 1901.2, 1905.1.1, 1905.1.2, 1905.1.8, 1908.1.1, 1908.1.2, 1908.1.5, 1908.1.6, 2209.1, 2210.2, 2304.6.1, Table 2306.3(3), Table 2308.7.5, 2404.1, 2505.1, 2505.2, 2506.2.1, G104.2.3.2, G304.2, G402 8—17 Standard Specification for the Design of Cold-formed Stainless Steel Structural Members 1604.3.3, 2210.1, 2210.2 19—16 Structural Applications of Steel Cables for Buildings 2208.1 24—14* * As modified in Appendix G Flood Resistant Design and Construction 202 (design flood elevation), 3001.2, G101.3, G102.1, G103.1, G104.2.1, G104.2.3.1, G104.2.3.2, G107.2, G107.3, G301.1, G303.3, G303.4, G303.5, G303.8, G304.1, G304.1.1, G304.1.2, G304.2, G304.3, G304.4.1.1, G305.2, G307.1, G307.2, G307.3, G308.1, G308.3, G308.5, G308.6, G308.7, G309.1, G310.3, G310.6 29—14 Standard Calculation Methods for Structural Fire Protection 722.1 32—17 Design and Construction of Frost Protected Shallow Foundations 1809.3.1 49—12 Wind Tunnel Testing for Buildings and Other Structures 1609.1.6.3 55—10 Tensile Membrane Structures 3102.7.3
ASME American Society of Mechanical Engineers Two Park Avenue New York, NY 10016-5990 Standard reference number Title Referenced in code section number ASME/A17.1—13* CSA B44—2013 * As modified in Appendix K Safety Code for Elevators and Escalators 907.3.3, 911.1.6, 1009.4, 1607.10.1, 2409.2, 2409.3, 2409.4, 2409.4.1 3001.2, 3001.4, 3002.1.2, 3002.4.3.1, 3002.4.3.2, 3002.4.3.3, 3002.5, 3002.8, 3003.2, 3003.3.1, 3007.1, 3008.1.3, 3008.8.1, 3009.3, K1 A17.2—2014 Guide for Inspection of Elevators, Escalators & Moving Walks 3001.2 A17.3—2015* * As modified in Appendix K Safety Code for Existing Elevators And Escalators 3001.2, K3 A17.5—2013 Elevator and Escalator Electrical Equipment 3001.2 A17.6—2010 Standard for Elevator Suspension, Compensation, and Governor Systems 3001.2 A17.7—2007/ CSA B44—07 Performance-Based Safety Code for Elevators and Escalators 3001.2 A18.1—2017 Safety Standard for Platform Lifts and Stairway Chairlifts 1109.7.1, 1109.7.1.1, 3001.2 A90.1—09 Safety Standard for Belt Manlifts 3001.2 B16.18—2012 Cast Copper Alloy Solder Joint Pressure Fittings 909.13.1 B16.22—2001(R2010) Wrought Copper and Copper Alloy Solder Joint Pressure Fittings 909.13.1 B20.1—2015* * As modified in Appendix K Safety Standard for Conveyors and Related Equipment 3001.2, 3004.3 B31.3—2012 Process Piping 415.11.6
ASTM ASTM International 100 Barr Harbor Drive West Conshohocken, PA 19428-2959 Standard reference number Title Referenced in code section number A 6/A 6M—14 Standard Specification for General Requirements for Rolled Structural Steel Bars, Plates, Shapes and Sheet Piling 1811.7.1, 1811.7.3, 1811.7.6 A 36/A 36M—14 Specification for Carbon Structural Steel 1811.7.1 A 153/A 153M—16a Specification for Zinc Coating (Hot-dip) on Iron and Steel Hardware 2304.10.5 A 240/A 240M—13A Standard Specification for Chromium and Chromium-nickel Stainless Steel Plate, Sheet and Strip for Pressure Vessels and for General Applications Table 1507.4.3(1) A 252—10 Specification for Welded and Seamless Steel Pipe Piles 1811.7.1, 1811.7.1.2, 1812.6.1 A 283/A 283M—13 Specification for Low and Intermediate Tensile Strength Carbon Steel Plates 1811.7.1, 1812.6.1 A 416/A 416M—15 Specification for Steel Strand, Uncoated Seven-wire for Prestressed Concrete 1811.6.3.1, 1815.3 A 463/A 463M—10 Standard Specification for Steel Sheet, Aluminum-coated, by the Hot-dip Process Table 1507.4.3(2) A 572/A 572M—15 Specification for High-strength Low-alloy Columbium-Vanadium Structural Steel 1811.7.1 A 588/A 588M—15 Specification for High-strength Low-alloy Structural Steel with 50 ksi (345 MPa) Minimum Yield Point with Atmospheric Corrosion Resistance 1811.7.1 A 615/A 615M—15ae1 Specification for Deformed and Plain Billet-steel Bars for Concrete Reinforcement 1812.7.2.1, 1812.8.1 A 653—15 Specification for Steel Sheet, Zinc-coated or Zinc-iron Alloy-coated Galvannealed by the Hot-dip Process 2304.10.5.1 A 653/A 653M—11 Specification for Steel Sheet, Zinc-coated Galvanized or Zinc-iron Alloy-coated Galvannealed by the Hot-dip Process Table 1507.4.3(1), Table 1507.4.3(2) A 690/A 690M—13a Standard Specification for High-strength Low-alloy Nickel, Copper, Phosphorus Steel H-piles and Sheet Piling with Atmospheric Corrosion Resistance for Use in Marine Environments 1811.7.1 A706/A706M—15 Specification for Low-alloy Steel Deformed and Plain Bars for Concrete Reinforcement 1705.3.1, 1903.5.2, 2107.3 A 722/A 722M—15 Specification for Uncoated High-strength Steel Bar for Prestressing Concrete 1812.7.2.1, 1812.8.1, 1815.3 A 755/A 755M—2011 Specification for Steel Sheet, Metallic-coated by the Hot-dip Process and Prepainted by the Coil-coating Process for Exterior Exposed Building Products Table 1507.4.3(1), Table 1507.4.3(2) A 792/A 792M—10 Specification for Steel Sheet, 55% Aluminum-zinc Alloy-coated by the (Hot-dip) Process Table 1507.4.3(1), Table 1507.4.3(2) A 875/A 875M—13 Standard Specification for Steel Sheet Zinc-5 percent, Aluminum Alloy-coated by the (Hot-dip) Process Table 1507.4.3(2) A 822—04a (2010) Standard Specification for Filled Epoxy-Coated Seven-Wire Prestressing Steel Strand 1815.3 A 924/A 924M—13 Standard Specification for General Requirements for Steel Sheet, Metallic-coated by the Hot-dip Process Table 1507.4.3(1) B 42—10 Specification for Seamless Copper Pipe, Standard Sizes 909.13.1 B 43—09 Specification for Seamless Red Brass Pipe, Standard Sizes 909.13.1 B 68—11 Specification for Seamless Copper Tube, Bright Annealed (Metric) 909.13.1 B 88—09 Specification for Seamless Copper Water Tube 909.13.1 B 101—12 Specification for Lead-coated Copper Sheet and Strip for Building Construction 1404.5.3, Table 1507.2.9.2, Table 1507.4.3(1) B 209—10 Specification for Aluminum and Aluminum Alloy Steel and Plate Table 1507.4.3(1) B 251—10 Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube 909.13.1 B 280—08 Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service 909.13.1 B 370—12 Specification for Copper Sheet and Strip for Building Construction 1404.5.2, Table 1507.2.9.2, Table 1507.4.3(1) B 695—04 (2016) Standard Specification for Coatings of Zinc Mechanically Deposited on Iron and Steel 2304.10.5.1, 2304.10.5.3 C 5—10 Specification for Quicklime for Structural Purposes Table 2507.2 C 22/C 22M-00 (2010) Specification for Gypsum Table 2506.2 C 27—98 (2013) Specification for Classification of Fireclay and High-alumina Refractory Brick 2111.6, 2111.9 C 28/C 28M—10 Specification for Gypsum Plasters Table 2507.2 C 31/C 31M—15 Practice for Making and Curing Concrete Test Specimens in the Field Table 1705.8.1 1905.1.3, 1905.6.3.3, 1905.6.3.3.1, 1905.6.3.8, 1905.6.4.2, 3305.3.5.6 C 33/C 33M—13 Specification for Concrete Aggregates 722.3.1.4, 722.4.1.1.3 C 35/C 35M—1995 (2009) Specification for Inorganic Aggregates for Use in Gypsum Plaster Table 2507.2 C 39/C 39M—14a Test Method for Compressive Strength of Cylindrical Concrete Specimens 1812.1.1.2.2, 1905.6.3.3.3, 1911.5.2, 1911.10.3 C 42/C 42M—13 Standard Test Method for Obtaining and Testing Drilled Cores and Sawed Beams of Concrete 1905.6.5.2, 1911.5.1, 1911.10, 1911.10.1 C 55—2011 Specification for Concrete Building Brick Table 722.3.2 C 59/C 59M—00 (2011) Specification for Gypsum Casting Plaster and Molding Plaster Table 2507.2 C 61/C 61M—00 (2011) Specification for Gypsum Keene's Cement Table 2507.2 C 67—13 Test Methods of Sampling and Testing Brick and Structural Clay Tile 721.4.1.1.1 C 73—10 Specification for Calcium Silicate Brick (Sand-lime Brick) Table 722.3.2 C 90—13 Specification for Loadbearing Concrete Masonry Units Table 722.3.2 C 91—12 Specification for Masonry Cement Table 2507.2 C 94/C 94M—15 Specification for Ready-Mixed Concrete 110.3.1, 1905.1.3, 1905.6.3.8, 1905.8.2 C 138/C 138M—17a Standard Test Method for Density (Unit Weight) Yield and Air Content (Gravimetric) of Concrete 1812.1.1.2.3, 1905.6.3.6 C 140—13 Test Method Sampling and Testing Concrete Masonry Units and Related Units 722.3.1.2 C 143—15a Standard Test Method for Slump of Hydraulic-cement Concrete 1905.6.3.6 C 150—15 Specification for Portland Cement Table 1904.4.2 Table 2507.2 C 172/C 172M—14a Practice for Sampling Freshly Mixed Concrete Table 1705.3 1905.6.3.2 C 173/C 173M—14 Standard Test Method for Air Content of Freshly Mixed Concrete by the Volumetric Method 1905.6.3.6 C 199—84 (2016) Test Method for Pier Test for Refractory Mortars 2111.6, 2111.9, 2113.12 C 206—13 Specification for Finishing Hydrated Lime Table 2507.2 C 208—12 Specification for Cellulosic Fiber Insulating Board Table 1508.2, 2303.1.6 C 216—13 Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale) Table 721.1(2), C 231/C 231M—14 Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method 1905.6.3.6 C 260/C 260M—10a (2016) Standard Specification for Air-entraining Admixtures for Concrete 1905.3.4 C 270—14a Specification for Mortar for Unit Masonry 2103.2.4 C 315—07 (2016) Specification for Clay Flue Liners and Chimney Pots 2111.9, 2113.11.1, Table 2113.16(1), Table 2113.16(2) C 317/C 317M—00 (2010) Specification for Gypsum Concrete 2514.1 C 330/C 330M—2014 Specification for Lightweight Aggregates for Structural Concrete 202 (concrete, lightweight aggregate; concrete, sand- lightweight), 1905.1.4 C 331/C 331M—2010 Specification for Lightweight Aggregates for Concrete Masonry Units 722.3.1.4, 722.4.1.1.3 C 406/C 406M—2010 Specification for Roofing Slate 1507.7.5 C 472—99 (2009) Specification for Standard Test Methods for Physical Testing of Gypsum, Gypsum Plasters and Gypsum Concrete Table 2506.2 C 473—12 Test Method for Physical Testing of Gypsum Panel Products Table 2506.2 C 474—13 Test Methods for Joint Treatment Materials for Gypsum Board Construction Table 2506.2 C 475/C 475M—12 Specification for Joint Compound and Joint Tape for Finishing Gypsum Board Table 2506.2 C 476—18 Specification for Grout for Masonry 202 (grout) C 494—13 Standard Specification for Chemical Admixtures for Concrete 1905.3.4 C 511—13 Standard Specification for Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage Tanks Used in the Testing of Hydraulic Cements and Concretes 1905.6.3.3.2 C 514—04 (2009)e1 Specification for Nails for the Application of Gypsum Board Table 721.1(2), Table 721.1(3), Table 2506.2 C 516—08 Specifications for Vermiculite Loose Fill Thermal Insulation 722.3.1.4, 722.4.1.1.3 C 547—12 Specification for Mineral Fiber Pipe Insulation Table 721.1(2), Table 721.1(3) C 549—06 (2012) Specification for Perlite Loose Fill Insulation 722.3.1.4, 722.4.1.1.3 C 552—12b Standard Specification for Cellular Glass Thermal Insulation Table 1508.2 C 557—03 (2009) Specification for Adhesives for Fastening Gypsum Wallboard to Wood Framing Table 2506.2 C 578—12b Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation Table 1508.2, 2603.10 C 587—04 (2009) Specification for Gypsum Veneer Plaster Table 2507.2 C 595/C 595M—14e1 Specification for Blended Hydraulic Cements Table 1904.4.2, Table 2507.2 C 618—12a Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete Table 1904.4.2 C 631—09 Specification for Bonding Compounds for Interior Gypsum Plastering Table 2507.2 C 635—00* * As modified in Appendix R Specification for the Manufacture, Performance and Testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings 808.1.1.1, R101.1, R102.1, R102.2, R102.3, Q102.1 C 636—96* * As modified in Appendix R Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels 808.1.1.1, R101.1, R103.1, R103.2, R103.3, R103.4, R103.5, R103.6, R103.7, R103.8, R103.9, R103.10, R103.11, R103.12, R103.13, R103.14 C 645—13 Specification for Nonstructural Steel Framing Members Table 2506.2, Table 2507.2 C 685—11 Standard Specification for Concrete Made by Volumetric Batching 1905.8.2 C 726—12 Standard Specification for Mineral Roof Insulation Board Table 1508.2 C 728—05 (2013) Standard Specification for Perlite Thermal Insulation Board Table 1508.2 C 744—11 Specification for Prefaced Concrete and Calcium Silicate Masonry Units Table 722.3.2 C 754—11 Specification for Installation of Steel Framing Members to Receive Screw-attached Gypsum Panel Products Table 2508.1, Table 2511.1.1 C 836/C 836M—12 Specification for High-solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane for Use with Separate Wearing Course 1507.15.2 C 840—11 Specification for Application and Finishing of Gypsum Board Table 2508.1, 2509.2 C 841—03 (2008)E1 Specification for Installation of Interior Lathing and Furring Table 2508.1, Table 2511.1.1 C 842—05 (2010)E1 Specification for Application of Interior Gypsum Plaster Table 2511.1.1, 2511.3, 2511.4 C 843—99 (2012) Specification for Application of Gypsum Veneer Plaster Table 2511.1.1 C 844—04 (2010) Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster Table 2508.1 C 845/C 845M—12 Standard Specification for Expansive Hydraulic Cement Table 1904.4.2 C 847—12 Specification for Metal Lath Table 2507.2 C 887—13 Specification for Packaged, Dry Combined Materials for Surface Bonding Mortar 2103.2.2 C 897—05 (2009) Specification for Aggregate for Job-Mixed Portland Cement-based Plaster Table 2507.2 C 920—11 Standard for Specification for Elastomeric Joint Sealants Table 2506.2 C 926—13 Specification for Application of Portland Cement-based Plaster 2510.3, Table 2511.1.1, 2511.3, 2511.4, 2512.1, 2512.1.2, 2512.2, 2512.6, 2512.8.2, 2512.9, 2513.7 C 932—06 (2013) Specification for Surface-applied Bonding Compounds for Exterior Plastering Table 2507.2 C 933—13 Specification for Welded Wire Lath Table 2507.2 C 946—10 Specification for Construction of Dry-stacked, Surface-bonded Walls 2103.2.2, 2109.2.2 C 954—11 Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs from 0.033 inch (0.84 mm) to 0.112 inch (2.84 mm) in Thickness Table 2506.2, Table 2507.2 C 955—11C Standard Specification for Load-bearing Transverse and Axial Steel Studs, Runners Tracks, and Bracing or Bridging, for Screw Application of Gypsum Panel Products and Metal Plaster Bases Table 2506.2, Table 2507.2 C 956—04 (2010) Specification for Installation of Cast-in-place Reinforced Gypsum Concrete 2514.1 C 957—10 Specification for High-solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane with Integral Wearing Surface 1507.15.2 C 989/C 989M—13 Standard Specification for Slag Cement for Use in Concrete and Mortars Table 1904.4.2 C 1002—07 Specification for Steel Self-piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs Table 2506.2, Table 2507.2 C 1007—11a Specification for Installation of Load Bearing (Transverse and Axial) Steel Studs and Related Accessories Table 2508.1, Table 2511.1.1 C 1029—13 Specification for Spray-applied Rigid Cellular Polyurethane Thermal Insulation 1507.14.2 C 1032—06(2011) Specification for Woven Wire Plaster Base Table 2507.2 C 1047—10A Specification for Accessories for Gypsum Wallboard and Gypsum Veneer Base Table 2506.2, Table 2507.2 C 1063—12D Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-based Plaster 2510.3, Table 2511.1.1, 2512.1.1 C 1064/C 1064M—17 Standard Test Method for Temperature of Freshly Mixed Hydraulic-cement Concrete 1905.6.3.6 C 1074—19 Standard Practice for Estimating Concrete Strength by the Maturity Method 3305.3.5.1.3 C 1088—13 Specification for Thin Veneer Brick Units Made from Clay or Shale Table 721.1(2) C 1157/C 1157M—11 Standard Performance Specification for Hydraulic Cement Table 1904.4.2, Table 2507.2 C 1167—11 Specification for Clay Roof Tiles 1507.3.4 C 1177/C 1177M—08 Specification for Glass Mat Gypsum Substrate for Use as Sheathing Figure 722.5.1(2), Figure 722.5.1(3), Table 1508.2, Table 2506.2 C 1178/C 1178M—11 Specification for Coated Mat Water-resistant Gypsum Backing Panel Figure 722.5.1(2), Figure 722.5.1(3), Table 2506.2, Table 2509.2 C 1186—08 (2012) Specification for Flat Fiber Cement Sheets 1404.10, 1405.16.1, 1405.16.2 C 1240—14 Standard Specification for Silica Fume Used in Cementitious Mixtures Table 1904.4.2 C 1261—10 Specification for Firebox Brick for Residential Fireplaces 2111.6, 2111.9 C 1278M—07a (2011) Specification for Fiber-reinforced Gypsum Panels Figure 722.5.1(2), Figure 722.5.1(3), Table 1508.2, Table 2506.2 C 1280—13 Specification for Application of Exterior Gypsum Panel Products for Use as Sheathing Table 2508.1, 2508.2 C 1283—11 Practice for Installing Clay Flue Lining 2113.9.1, 2113.12 C 1288—99 (2010) Standard Specification for Discrete Nonasbestos Fiber-cement Interior Substrate Sheets Table 2509.2 C 1289—13E1 Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board Table 1508.2, 2603.10 C 1313/C 1313M—12 Standard Specification for Sheet Radiant Barriers for Building Construction Applications 1509.4 C 1325—08b Standard Specification for Nonasbestos Fiber-mat Reinforced Cement Backer Units Table 2509.2 C 1328/C1328M—12 Specification for Plastic (Stucco Cement) Table 2507.2 C 1364—10B Standard Specification for Architectural Cast Stone 2103.1 C 1371—04a (2010)e1 Standard Test Method for Determination of Emittance of Materials Near Room Temperature Using Portable Emissometers 1504.9 C 1386—07 Specification for Precast Autoclaved Aerated Concrete (AAC) Wall Construction Units 202 (autoclaved aerated concrete (aac)), 2102.1, C 1396M/C 1396M—13 Specification for Gypsum Board Table 2506.2, Table 2508.1 Figure 722.5.1(2), Figure 722.5.1(3) C 1492—03 (2009) Standard Specification for Concrete Roof Tile 1507.3.5 C 1549—09 Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature Using a Portable Solar Reflectometer 1504.9 C 1600/C 1600M—11 Standard Specification for Rapid Hardening Hydraulic Cement Table 2507.2 C 1629/C 1629M—06 (2011) Standard Classification for Abuse-resistant Nondecorated Interior Gypsum Panel Products and Fiber-reinforced Cement Panels 403.2.3.1, 403.2.3.2, 403.2.3.4 C 1658/C 1658M—12 Standard Specification for Glass Mat Gypsum Panels Figure 722.5.1(2), Figure 722.5.1(3), Table 2506.2 C 1670—16 Standard Specification for Adhered Manufactured Stone Masonry Veneer Units 2103.1 D 25—12 (2017) Specification for Round Timber Piles 1811.5.1, 1811.5.4, 2303.1.12 D 41—05 Specification for Asphalt Primer Used in Roofing, Dampproofing and Waterproofing Table 1507.10.2 D 43—00 (2006) Specification for Coal Tar Primer Used in Roofing, Dampproofing and Waterproofing Table 1507.10.2 D 56—05 (2010) Test Method for Flash Point By Tag Closed Tester 202 (flashpoint) D 86—2012 Test Method for Distillation of Petroleum Products at Atmospheric Pressure 202 (boiling point) D 93—2012 Test Method for Flash Point By Pensky-Martens Closed Cup Tester 202 (flashpoint) D 225—07 Specification for Asphalt Shingles (Organic Felt) Surfaced with Mineral Granules 1507.2.5 D 226/D 226M—09 Specification for Asphalt-saturated Organic Felt Used in Roofing and Waterproofing 1404.2, 1505.2, 1507.2.3, 1507.3.3, 1507.5.3, 1507.6.3, 1507.7.3, Table 1507.8, 1507.8.3, 1507.9.3, 1507.9.5, Table 1507.10.2, 1507.17.3, 1507.17.4.1 D 227/D 227M—03 (2011)E1 Specification for Coal-tar-saturated Organic Felt Used in Roofing and Waterproofing Table 1507.10.2 D 312—00 (2006) Specification for Asphalt Used in Roofing Table 1507.10.2 D 448—08 Standard Classification for Sizes of Aggregate for Road and Bridge Construction 1507.12.3, 1507.13.3 D 450—07 Specification for Coal-tar Pitch Used in Roofing, Dampproofing and Waterproofing Table 1507.10.2 D 635—10 Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position 2606.4, H107.1.1, H117.4 D 692/D 692M—15 Standard Specification for Coarse Aggregate for Bituminous Paving Mixtures 1913.2 D 1073—16 Standard Specification for Fine Aggregate for Asphalt Paving Mixtures 1913.2 D 1143/D 1143M—07 (2013)e1 Standard Test Methods for Deep Foundations Under Static Axial Compressive Load 1810.4.1.3, 1810.4.1.5.1, 1814.4.1 D 1227—95 (2007) Specification for Emulsified Asphalt Used as a Protective Coating for Roofing Table 1507.10.2, 1507.15.2 D 1557—12e1 Test Method for Laboratory Compaction Characteristics of Soil Using Modified Effort (56,000 ft-lb/ ft3 (2,700 KN m/m3)) 1806.2.2 D 1586—18 Specification for Penetration Test and Split-barrel Sampling of Soils 1613.3.4.1, 1803.5 D 1587—15 Standard Practice for Thin-walled Tube Sampling of Fine-Grained Soils for Geotechnical Purposes 1803.5 D 1761—12 Test Method for Mechanical Fasteners in Wood 1712.1.1, 1712.1.2, 1712.1.3 D 1863/D 1863M—05 (2011)E1 Specification for Mineral Aggregate Used on Built-up Roofs Table 1507.10.2 D 1929—12 Test Method for Determining Ignition Temperature of Plastics 402.6.4.4, 1407.11.2.1, 2606.4 D 1970/D 1970M—2013 Specification for Self-adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roof Underlayment for Ice Dam Protection 1507.2.3 1507.2.4, 1507.2.9.2, 1507.3.9, 1507.5.7, 1507.8.8, 1507.9.9, 1507.17.4.1 D 2113—14 Standard Practice for Rock Core Drilling and Sampling of Rock for Site Investigation 1803.5 D 2166—16 Standard Test Method for Unconfined Compressive Strength of Cohesive Soil 1613.3.4.1 D 2178—04 Specification for Asphalt Glass Felt Used in Roofing and Waterproofing Table 1507.10.2 D 2216—19 Test Method for Laboratory Determination of Water (Moisture) Content of Soil and Rock by Mass 1613.3.4.1 D 2487—2017 Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System) Table 1610.1, 1803.3 D 2626/D 2626M—04 (2012)E1 Specification for Asphalt Saturated and Coated Organic Felt Base Sheet Used in Roofing 1507.3.3, Table 1507.10.2 D 2822/D 2822M—05 (2011)E1 Specification for Asphalt Roof Cement, Asbestos Containing Table 1507.10.2 D 2823/D 2823M—05 (2011)E1 Specification for Asphalt Roof Coatings, Asbestos Containing Table 1507.10.2 D 2824—06 (2012)E1 Standard Specification for Aluminum-Pigmented Asphalt Roof Coating, Nonfibered, Asbestos Fibered and Fibered without Asbestos Table 1507.10.2 D 2843—10 Test for Density of Smoke from the Burning or Decomposition of Plastics 2606.4 D 2850—15 Standard Test Method for Unconsolidated-Undrained Triaxial Compression Test on Cohesive Soils 1613.3.4.1 D 2898—10 (2017) Test Methods for Accelerated Weathering of Fire-retardant-treated Wood for Fire Testing 1505.1, 2303.2.4, 2303.2.6 D 3019—08 Specification for Lap Cement Used with Asphalt Roll Roofing, Nonfibered, Asbestos Fibered and Nonasbestos Fibered Table 1507.10.2 D 3161/D 3161M—13 Test Method for a Wind Resistance of Asphalt Shingles (Fan Induced Method) 1504.1.1, Table 1504.1.1, 1507.17.8 D 3200—74 (2017) Standard Specification and Test Method for Establishing Recommended Design Stresses for Round Timber Construction Poles 2303.1.12 D 3201—2013 Test Method for Hygroscopic Properties of Fire-retardant Wood and Wood-based Products 2303.2.7 D 3273—12 Standard Test Method for Resistance to Growth of Mold on the Surface of Interior Coatings in an Environmental Chamber 2506.3 D 3278—1996 (2011) Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus 202 (flashpoint) D 3441—2016 Standard Test Method for Mechanical Cone Penetration Testing of Soils 1803.5.2 D 3462/D 3462M—10A Specification for Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules 1507.2.5 D 3468—99 (2006)e01 Specification for Liquid-applied Neoprene and Chlorosulfonated Polyethylene Used in Roofing and Waterproofing 1507.15.2 D 3679—11 Specification for Rigid Poly (Vinyl Chloride) (PVC) Siding 1404.9, 1405.14 D 3689—07(2013)E1 Test Methods for Deep Foundations Under Static Axial Tensile Load 1810.4.2.1, 1814.4.2 D 3737—2018 Practice for Establishing Allowable Properties for Structural Glued Laminated Timber (Glulam) 2303.1.3 D 3746—85 (2008) Test Method for Impact Resistance of Bituminous Roofing Systems 1504.7 D 3747—79 (2007) Specification for Emulsified Asphalt Adhesive for Adhering Roof Insulation Table 1507.10.2 D 3909/D 3909M—97b (2012)e1 Specification for Asphalt Roll Roofing (Glass Felt) Surfaced with Mineral Granules 1507.2.9.2, 1507.6.5, Table 1507.10.2 D 3957—09 (2015) Standard Practices for Establishing Stress Grades for Structural Members Used in Log Buildings 2303.1.11 D 3966—07 (2013)E1 Standard Test Methods for Deep Foundations Under Lateral Loads 1810.4.3, 1810.4.3.3 D 4022/D 4022M—2007 (2012)E1 Specification for Coal Tar Roof Cement, Asbestos Containing Table 1507.10.2 D 4272—09 Test Method for Total Energy Impact of Plastic Films by Dart Drop 1504.7 D 4318—2013E1 Test Methods for Liquid Limit, Plastic Limit and Plasticity Index of Soils 1613.3.4.1 D 4434/D 4434M—12 Specification for Poly (Vinyl Chloride) Sheet Roofing 1507.13.2 D 4479/D 4479M—07 (2012)E1 Specification for Asphalt Roof Coatings-Asbestos-free Table 1507.10.2 D 4586/D 4586M—07 (2012)E1 Specification for Asphalt Roof Cement-Asbestos-free Table 1507.10.2 D 4601/D 4601M—04 (2012)E1 Specification for Asphalt-coated Glass Fiber Base Sheet Used in Roofing Table 1507.10.2 D 4637/D 4637M—13 Specification for EPDM Sheet Used in Single-ply Roof Membrane 1507.12.2 D 4869/D 4869M—05 (2011)e01 Specification for Asphalt-saturated (Organic Felt) Underlayment Used in Steep Slope Roofing 1507.2.3, 1507.5.3, 1507.6.3, 1507.7.3, 1507.8.3, 1507.9.3, 1507.17.3, 1507.17.4.1 D 4897/D 4897M—01 (2009) Specification for Asphalt-coated Glass Fiber Venting Base Sheet Used in Roofing Table 1507.10.2 D 4990—97a (2005)e01 Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing Table 1507.10.2 D 4945—17 Test Method for High-strain Dynamic Testing of Piles 1810.4.1.4 D 5019—07a Specification for Reinforced Nonvulcanized Polymeric Sheet Used in Roofing Membrane 1507.12.2 D 5034—09 (2017) Standard Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test) 3308.6.3 D 5035—11 (2019) Standard Test Method for Breaking Force and Elongation of Textile Fabrics (Strip Method) 3308.6.3 D 5055—16 Standard Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I-joists 2303.1.2 D 5096—2002 (2017) Standard Test Method for Determining the Performance of a Cup Anemometer or Propeller Anemometer 3314.4.4.6, 3316.7.8.5, 3319.13.2 D 5456—17E1 Specification for Evaluation of Structural Composite Lumber Products Table 1705.5.6, 2303.1.10 D 5516—17 Test Method of Evaluating the Flexural Properties of Fire-retardant-treated Softwood Plywood Exposed to the Elevated Temperatures 2303.2.5.1 D 5643/D 5643M—06 (2012)E1 Specification for Coal Tar Roof Cement, Asbestos-free Table 1507.10.2 D 5664—17 Standard Test Method for Evaluating the Effects of Fire-retardant Treatment and Elevated Temperatures on Strength Properties of Fire-retardant Treated Lumber 2303.2.5.2 D 5665—99a (2006) Specification for Thermoplastic Fabrics Used in Cold-applied Roofing and Waterproofing Table 1507.10.2 D 5726—98 (2005) Specification for Thermoplastic Fabrics Used in Hot-applied Roofing and Waterproofing Table 1507.10.2 D 5778—12 Standard Test Method for Electronic Friction Cone and Piezocone Penetration Testing of Soils 1803.5.2 D 6066—11 Standard Practice for Determining the Normalized Penetration Resistance of Sands for Evaluation of Liquefaction Potential 1816.2 D 6083—05e01 Specification for Liquid Applied Acrylic Coating Used in Roofing Table 1507.10.2, Table 1507.14.3, 1507.15.2 D 6162—2000A (2008) Specification for Styrene-butadiene-styrene (SBS) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements 1507.11.2 D 6163—00 (2008) Specification for Styrene-butadiene-styrene (SBS) Modified Bituminous Sheet Materials Using Glass Fiber Reinforcements 1507.11.2 D 6164/D 6164M—11 Specification for Styrene-butadiene-styrene (SBS) Modified Bituminous Sheet Metal Materials Using Polyester Reinforcements 1507.11.2 D 6222/D 6222M—11 Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using Polyester Reinforcements 1507.11.2 D 6223/D 6223M—02 (2011)E1 Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements 1507.11.2 D 6298—05e1 Specification for Fiberglass Reinforced Styrene-butadiene-styrene (SBS) Modified Bituminous Sheets with a Factory Applied Metal Surface 1507.11.2 D 6305—08 (2015)E1 Practice for Calculating Bending Strength Design Adjustment Factors for Fire-retardant-treated Plywood Roof Sheathing 2303.2.5.1 D 6380—03 (2009) Standard Specification for Asphalt Roll Roofing (Organic) Felt 1507.2.9.2, 1507.3.3, 1507.6.5 D 6509/D 6509M—09 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous base Sheet Materials Using Glass Fiber Reinforcements 1507.11.2 D 6694—08 Standard Specification for Liquid-applied Silicone Coating Used in Spray Polyurethane Foam Roofing Systems Table 1507.14.3, 1507.15.2 D 6754/D 6745M—10 Standard Specification for Ketone Ethylene Ester Based Sheet Roofing 1507.13.2 D 6757—2013 Standard Specification for Underlayment for Use with Steep Slope Roofing 1507.2.3, 1507.17.3, 1507.17.4.1 D 6841—16 Standard Practice for Calculating Design Value Treatment Adjustment Factors for Fire-retardant-treated Lumber 2303.2.5.2 D 6878/D 6878M—11a Standard Specification for Thermoplastic Polyolefin Based Sheet Roofing 1507.13.2 D 6947—07 Standard Specification for Liquid Applied Moisture Cured Polyurethane Coating Used in Spray Polyurethane Foam Roofing System Table 1507.14.3, 1507.15.2 D 7032—10a Standard Specification for Establishing Performance Ratings for Wood, Plastic Composite Deck Boards and Guardrail Systems (Guards or Rails) 2612.2.1, 2612.2.2, 2612.4, 2612.5.1 D 7147—11 Standard Specification for Testing and Establishing Allowable Loads of Joist Hangers 2303.5, 2304.10.3 D 7158/D 7158M—11 Standard Test Method for Wind Resistance of Sealed Asphalt Shingles (Uplift Force/Uplift Resistance Method) 1504.1.1, Table 1504.1.1 D 7254—07 Standard Specification for polypropylene (PP) siding 1404.12 D 7655—12 Standard Classification for Size of Aggregate Used as Ballast for Roof Membrane Systems 1507.12.3, 1507.13.3 D 7672—2014 Standard Specification for Evaluating Structural Capacities of Rim Board Products and Assemblies 2303.1.3 E 84—2013A Test Methods for Surface Burning Characteristics of Building Materials 202 (flame spread index; smoke- developed index), 402.6.4.4, 402.6.2, 703.5.2, 720.1, 720.1.1, 720.1.2, 720.4, 803.1.1, 803.1.4, 803.1.4.1, 803.10, 803.11, 806.7, 1404.12.1, 1510.10.3, 2303.2, 2603.3, 2603.4.1.13, 2606.3.5.4, 2603.5.5, 2603.7, 2603.7.1, 2603.7.3, 2604.2.4, 2606.4, 2612.3, 2614.3, 3105.3, K1 E 90—09 Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements 1207.2, 1207.2.1 E 108—2011 Test Methods for Fire Tests of Roof Coverings 1505.1, 2603.6, 2610.2, 2610.3 E 119—2012A Standard Test Methods for Fire Tests of Building Construction and Materials 703.2, 703.2.1, 703.2.3, 703.2.5, 703.3, 703.4, 703.6, 704.12, 705.7, 705.8.5, 707.6, 712.1.13.2, 714.3.1, 714.4.1, 715.1, 715.4, 716.2, Table 716.3, Table 716.5, 716.5.6, 716.5.8.1.1, Table 716.6, 716.6.7.1, 717.3.1, 717.5.2, 717.5.3, 717.6.1, 716.6.2.1, Table 721.1(1), 1407.10, 1409.10, 2103.1, 2603.4, 2603.5.1, 2603.5.2 E 136—2012 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C 703.5.1, 720.1.1 E 330—02 Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference 1705.9.2 E 331—00 (2009) Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Uniform Static Air Pressure Difference 1403.2 E 336—05 Standard Test Method for Measurement of Airborne Sound Insulation in Buildings 1207.2 E 408—13 Standard Test Methods for Total Normal Emittance of Surfaces Using Inspection-meter Techniques 1504.9 E 492—09 Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-ceiling Assemblies Using the Tapping Machine 1207.3 E 605—93 (2011) Test Method for Thickness and Density of Sprayed Fire-resistive Material (SFRM) Applied to Structural Members 1705.14.4.1, 1705.14.4.2, 1705.14.4.5, 1705.14.5 E 648—06a Standard Test Method for Critical Radiant Flux of Floor-covering Systems Using a Radiant Heat Energy Source 804.2 E 681—2009 Test Methods for Concentration Limits of Flammability of Chemical Vapors and Gases 202 (flammable gas) E 736—00 (2011) Test Method for Cohesion/Adhesion of Sprayed Fire-resistive Materials Applied to Structural Members 704.13.2, 1705.14.6 E 814—2013 Test Method of Fire Tests of Through-penetration Firestops 202 (f rating; t rating), 714.3.1.2, 714.3.2, 714.4.1.2 E 970—2010 Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source 720.3.1 E 1007—97 Test Method for Field Measurement of Tapping Machine Impact Sound Transmission through Floor-ceiling Assemblies and Associated Support Structures 1207.3 E 1300—12AE1 Practice for Determining Load Resistance of Glass in Buildings 2404.1 E 1354—2013 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter 424.2 E 1592—05 (2012) Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference 1504.3.2 E 1602—02 (2010)E1 Guide for Construction of Solid Fuel-burning Masonry Heaters 2112.2 E 1886—13A Test Method for Performance of Exterior Windows, Curtain Walls, Doors and Storm Shutters Impacted by Missiles and Exposed to Cyclic Pressure Differentials 1609.1.2 E 1918—16 Standard Test Method for Measuring Solar Reflectance of Horizontal and Low-sloped Surfaces in the Field 1504.9 E 1966—07A (2011) Test Method for Fire-resistant Joint Systems 202 (fire-resistant joint system), 715.3 E 1980—11 Standard Practice for Calculating Solar Reflectance Index of Horizontal and Low-sloped Opaque Surfaces 1504.9 E 1996—2014a* * As modified in Chapter 16 Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes 1609.1.2, 1609.1.2.2 E 2072—10 Standard Specification for Photoluminescent (Phosphorescent) Safety Markings 1025.4, Figure S101.1(2), Figure S101.1(3), Figure S101.1(4), Figure S101.1(5), Figure S101.1(6), Figure S101.1(7), Figure S101.1(8) E 2174—10AE1 Standard Practice for On-Site Inspection of Installed Fire Stops 1705.17.1 E 2273—03 (2011) Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies 1408.4.1 E 2307—2010 Standard Test Method for Determining Fire Resistance of a Perimeter Joint System Between an Exterior Wall Assembly and Floor Assembly Using the Intermediate-scale, Multistory Test Apparatus 715.4 E 2353—2014 Standard Test Methods for Performance of Glazing in Permanent Railing Systems, Guards and Balustrades 2407.1.2 E 2393—10A Standard Practice for On-Site Inspection of Installed Fire Resistive Joint Systems and Perimeter Fire Barrier 1705.17.2 E 2404—2013E1 Standard Practice for Specimen Preparation and Mounting of Textile, Paper or Vinyl Wall or Ceiling Coverings to Assess Surface Burning Characteristics 803.1.4 E 2556—10 Standard Specification for Vapor Permeable Flexible Sheet Water-Resistive Barriers Intended for Mechanical Attachment 2510.6 E 2568—09e1 Standard Specification for PB Exterior Insulation and Finish Systems 1408.2 E 2570—07 Standard Test Method for Evaluating Water-resistive Barrier (WRB) Coatings Used Under Exterior Insulation and Finish Systems (EIFS) for EIFS with Drainage 1408.4.1.1, 1705.16 E 2573—12 Standard Practice for Specimen Preparation and Mounting of Site-fabricated Stretch Systems to Assess Surface Burning Characteristics 803.10 E 2599—11 Standard Practice for Specimen Preparation and Mounting of Reflective Insulation Materials and Vinyl Stretch Ceiling Materials for Building Applications to Assess Surface Burning Characteristics 2614.3 E 2634—11 (2015) Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems 1903.4 E 2751—13 Standard Practice for Design and Performance of Supported Glass Walkways 2409.1 F 547—2012 Terminology of Nails for Use with Wood and Wood-based Materials Table 2506.2 F 1346—91 (2003) Performance Specification for Safety Covers and Labeling Requirements for All Covers for Swimming Pools, Spas and Hot Tubs 3109.3.2.1, 3109.4, 3109.5.1.8, 3109.6 F 1667—2015 Specification for Driven Fasteners: Nails, Spikes and Staples Table 721.1(2), Table 721.1(3), 1507.2.6, 1507.17.5, 2303.6, Table 2304.10.1, 2304.10.5, Table 2506.2 F 2090—10 Specification for Window Fall Prevention Devices with Emergency Escape (Egress) Release Mechanisms 1015.8 F 2200—2013 Standard Specification for Automated Vehicular Gate Construction 3110.3 F 2208—08 Standard Safety Specification for Residential Pool Alarms 3109.3.2.1 G 152—06 Practice for Operating Open Flame Carbon Arc Light Apparatus for Exposure of Nonmetallic Materials 1504.6 G 154—06 Practice for Operating Fluorescent Light Apparatus for UV Exposure of Nonmetallic Materials 1504.6 G 155—05a Practice for Operating Xenon Arc Light Apparatus for Exposure of Nonmetallic Materials 1504.6
AWC American Wood Council 222 Catoctin SE, Suite 201 Leesburg, VA 20175 Standard reference number Title Referenced in code section number AWC WCD No. 4—2003 Wood Construction Data—Plank and Beam Framing for Residential Buildings 2306.1.2 AWC WFCM—2018 Wood Frame Construction Manual for One- and Two-Family Dwellings 1609.1.1, 1609.1.1.1, 2301.2, 2308.2.4, 2308.6.7.2, 2309.1 ANSI/AWC NDS—2018 National Design Specification (NDS) for Wood Construction with 2018 NDS Supplement 202 (nominal size (lumber)), 722.1, Table 1604.3, Table 1705.5.6, 1711.1.1, 1711.1.4, 1811.5, 1908.1.5, 2304.13, 2306.1, 2306.1.3, Table 2306.2(1), Table 2306.2(2), Table 2306.3(1), Table 2306.3(2), 2307.1 AWC STJR—2015 Span Tables for Joists and Rafters 2306.1.1, 2308.4.2.1, 2308.7.1, 2308.7.2 ANSI/AWC PWF—2015 Permanent Wood Foundation Design Specification 2304.10.5.2 AWC SDPWS—2015 Special Design Provisions for Wind and Seismic 202 (shear wall, shear wall segment, perforated), 2305.1, 2305.2, 2305.3, 2306.1, 2306.2, 2306.3, Table 2306.3(1), Table 2306.3(3) AWC TR7—2007 Basic Requirements for Permanent Wood Foundation System, Technical Report No. 7 1805.2
AWCI Association of the Wall and Ceiling Industry 513 West Broad Street, Suite 210 Falls Church, VA 22046 Standard reference number Title Referenced in code section number 12-B—04 Technical Manual 12-B Standard Practice for the Testing and Inspection of Field Applied Thin Film Intumescent Fire-resistive Materials; an Annotated Guide, Second Edition 1705.15
AWPA American Wood Protection Association P.O. Box 361784 Birmingham, AL 35236-1784 Standard reference number Title Referenced in code section number C1—03 All Timber Products-Preservative Treatment by Pressure Processes 1505.6 M4—16 Standard for the Care of Preservative-treated Wood Products 1811.5.2, 2303.1.9 U1—16 USE CATEGORY SYSTEM: User Specification for Treated Wood Table 1507.9.6, 1811.5.2, 2303.1.9, 2304.12.1, 2304.12.2, 2304.12.3, 2304.12.4, 2304.12.5
AWS American Welding Society 8669 NW 36 Street, #130 Doral, FL 33166 Standard reference number Title Referenced in code section number D1.1—15 Structural Welding Code—Steel Table 1705.2, 1705.2.1.1, 1811.7.1.1, K1 D1.2—03 Structural Welding Code—Aluminum 1705.33.1, 2003.2.2 D1.3—98 Structural Welding Code—Sheet Steel Table 1705.2 D1.4/D1.4M—2017 Structural Welding Code-Reinforcing Steel Including Metal Inserts and Connections In Reinforced Concrete Construction Table 1705.2, 1705.2.1.3, Table 1705.3, 1903.6.2, 2107.3
AWWA American Water Works Association 6666 West Quincy Avenue Denver, CO 80235 Standard reference number Title Referenced in code section number C 104—08 American National Standard for Cement-Mortar Lining for Ductile-Iron Pipe and Fittings for Water Q105.1
BHMA Builders Hardware Manufacturers' Association 355 Lexington Avenue, 17th Floor New York, NY 10017-6603 Standard reference number Title Referenced in code section number A 156.10—2011 Power Operated Pedestrian Doors 1010.1.4.2 A 156.19—2013 Standard for Power Assist and Low Energy Operated Doors 1010.1.4.2 A 156.27—11 Power and Manual Operated Revolving Pedestrian Doors 1010.1.4.1
CEN European Committee for Standardization (CEN) Central Secretariat Rue de Stassart 36 B-10 50 Brussels Standard reference number Title Referenced in code section number EN 1081—98 Resilient Floor Coverings—Determination of the Electrical Resistance 406.7.1 BS EN 15250—2007 Slow Heat Release Appliances Fired By Solid Fuel Requirements and Test Methods 2112.2, 2112.5
CGSB Canadian General Standards Board Place du Portage 111, 6B1 11 Laurier Street Gatineau, Quebec, Canada KIA 1G6 Standard reference number Title Referenced in code section number 37-GP-52M (1984) Roofing and Waterproofing Membrane, Sheet Applied, Elastomeric 1504.7, 1507.12.2 37-GP-56M (1980) Membrane, Modified, Bituminous, Prefabricated and Reinforced for Roofing—with December 1985 Amendment 1507.11.2 CAN/CGSB 37.54—95 Polyvinyl Chloride Roofing and Waterproofing Membrane 1507.13.2
CPA Composite Panel Association 19465 Deerfield Avenue, Suite 306 Leesburg, VA 20176 Standard reference number Title Referenced in code section number ANSI A135.4—2012 Basic Hardboard 2303.1.7 ANSI A135.5—2012 Prefinished Hardboard Paneling 1404.3.1, 2303.1.7, 2304.7 ANSI A135.6—2012 Engineered Wood Siding 1405.3.2, 2303.1.7 A208.1—09 Particleboard 2303.1 8, 2303.1.8.1
CPSC Consumer Product Safety Commission 4330 East West Highway Bethesda, MD 20814-4408 Standard reference number Title Referenced in code section number 16 CFR Part 1201 (2002) Safety Standard for Architectural Glazing Material 2406.2, Table 2406.2(1), 2406.3.1, 2407.1, 2407.1.4.1, 2408.2.1, 2408.3, 2409.2, 2409.3, 2409.4.1 16 CFR Part 1209 (2002) Interim Safety Standard for Cellulose Insulation 720.6 16 CFR Part 1404 (2002) Cellulose Insulation 720.6 16 CFR Part 1500.44 (2009) Method for Determining Extremely Flammable and Flammable Solids 202 (flammable solid) 16 CFR Part 1630 (2007) Standard for the Surface Flammability of Carpets and Rugs 804.4.1
CSA Canadian Standards Association 8501 East Pleasant Valley Cleveland, OH 44131-5516 Standard reference number Title Referenced in code section number AAMA/WDMA/CSA 101/I.S.2/A440—11 Specifications for Windows, Doors and Unit Skylights 1709.5.1, 2405.5
CSSB Cedar Shake and Shingle Bureau P. O. Box 1178 Sumas, WA 98295-1178 Standard reference number Title Referenced in code section number CSSB—97 Grading and Packing Rules for Western Red Cedar Shakes and Western Red Shingles of the Cedar Shake and Shingle Bureau Table 1507.8.5, Table 1507.9.6
DASMA Door and Access Systems Manufacturers Association International 1300 Summer Avenue Cleveland, OH 44115-2851 Standard reference number Title Referenced in code section number ANSI/DASMA 107—1997 (R2012) Room Fire Test Standard for Garage Doors Using Foam Plastic Insulation 2603.4.1.9 108—12 Standard Method for Testing Sectional Garage Doors and Rolling Doors: Determination of Structural Performance Under Uniform Static Air Pressure Difference 1709.5.2 115—16 Standard Method for Testing Sectional Garage Doors and Rolling Doors: Determination of Structural Performance Under Missile Impact and Cyclic Wind Pressure 1609.1.2.3
DOC U.S. Department of Commerce National Institute of Standards and Technology 1401 Constitution Avenue NW Washington, DC 20230 Standard reference number Title Referenced in code section number PS-1—09 Structural Plywood 2303.1.5, 2304.7, Table 2304.8(4), Table 2304.8(5), Table 2306.2(1), Table 2306.2(2) PS-2—10 Performance Standard for Wood-based Structural-use Panels 2303.1.5, 2304.7, Table 2304.7(5), Table 2304.8(5), Table 2306.2(1), Table 2306.2(2) PS 20—05 American Softwood Lumber Standard 202 (grade (lumber)), 2303.1.1
DOJ U.S. Department of Justice 950 Pennsylvania Avenue, NW Civil Rights Division, Disability Rights Section-NYA Washington, DC 20530 Standard reference number Title Referenced in code section number 36 CFR Part 1192 American with Disabilities Act (ADA) Accessibility Guidelines for Transportation Vehicles (ADAAG) Department of Justice, 1991 E109.2.4, E111.4
DOL U.S. Department of Labor Frances Perkins Building 200 Constitution Avenue NW Washington, DC 20210 Standard reference number Title Referenced in code section number 29 CFR Part 1910.1000 (2009) Air Contaminants 202 (ceiling limit)
DOT NYS Department of Transportation Main Office 50 Wolf Road Albany, NY 12232 Standard reference number Title Referenced in code section number EI 19—001 NYSDOT LRFD Bridge Design Specifications - 2019 1607.7.1 BM—2019 NYSDOT Bridge Manual 1607.7.1
DOTn U.S. Department of Transportation c/o Superintendent of Documents East Building, 2nd floor Washington, DC 20590 Standard reference number Title Referenced in code section number 49 CFR Parts 100—185 (2005) Hazardous Materials Regulations 202 49 CFR Parts 173.137 (2009) Shippers—General Requirements for Shipments and Packaging—Class 8—Assignment of Packing Group 202 (corrosive material) 49 CFR Parts 173—178 (1999) Specification of Transportation of Explosive and Other Dangerous Articles, UN 0335, UN 0336 Shipping Containers 202 (combustible liquid; explosive; fireworks; flammable liquid)
FEMA Federal Emergency Management Agency Federal Center Plaza 500 C Street S.W. Washington, DC 20472 Standard reference number Title Referenced in code section number FIS 360497 Federal Emergency Management Agency Flood Insurance Study report 202 (500-year flood elevation), G102.2, G402 FIRMs 360497 Federal Emergency Management Agency Flood Insurance Rate Map 202 (500-year flood elevation; base flood elevation; coastal a-zone; coastal high hazard area), G102.2, G102.3, G102.3.1, G102.3.2, G103.3.1, G103.3.2, G402 FORM 086-0-34—12 Floodproofing Certificate; Federal Emergency Management Agency G107.3, G402 FORM 086-0-33—12 Elevation Certificate; Federal Emergency Management Agency G107.3, G402
FM Factory Mutual Global Research Standards Laboratories Department 1301 Atwood Avenue, P.O. Box 7500 Johnston, RI 02919 Standard reference number Title Referenced in code section number 4430 (2012) Approval Standard for Heat and Smoke Vents 910.3.1 4470 (2012) Approval Standard for Single-Ply Polymer-Modified Bitumen Sheet, Built-Up Roof (BUR) And Liquid Applied Roof Assemblies for use in Class 1 and Noncombustible Roof Deck Construction 1504.7 4474 (2011) American National Standard for Evaluating the Simulated Wind Uplift Resistance of Roof Assemblies Using Static Positive and/or Negative Differential Pressures 1504.3.1, 1504.3.2 4880 (2010) Approval Standard for Class 1 Fire Rating of Insulated Wall or Wall and Roof/Ceiling Panels, Interior Finish Materials or Coatings and Exterior Wall Systems 2603.4, 2603.9 DS 1-35 (2017) Factory Mutual Data Sheet – Green Roof Systems 1507.16.1
GA Gypsum Association 6525 Belcrest Road, Suite 480 Hyattsville, MD 20782 Standard reference number Title Referenced in code section number GA 216—13 Application and Finishing of Gypsum Panel Products Table 2508.1, 2509.2 GA 600—12 Fire-Resistance Design Manual, 20th Edition Table 721.1(1), Table 721.1(2), Table 721.1(3)
HPVA Hardwood Plywood Veneer Association 1825 Michael Faraday Drive Reston, VA 20190 Standard reference number Title Referenced in code section number HP-1—2016 American National Standard for Hardwood and Decorative Plywood 2303.3, 2304.7
HUD U.S. Department of Housing and Urban Development 451 7th Street, SW Washington, DC 20410 Standard reference number Title Referenced in code section number HUD 24 CFR Part 3280 (2008) Manufactured Home Construction and Safety Standards G201.1.2, G402
ICC International Code Council, Inc. 500 New Jersey Ave, NW 6th Floor Washington, DC 20001 Standard reference number Title Referenced in code section number ICC A117.1—09 Accessible and Usable Buildings and Facilities 202 (accessible unit, type b unit, type b+nyc unit), 907.2.11.1.1, 1009.8.2, 1009.9, 1009.11, 1010.1.9.7, 1012.1, 1012.6.5, 1012.10, 1013.4, 1023.9.3, 1101.2, 1103.2.2, 1105.1.7, 1106.1, 1106.5, 1106.6, 1106.7, 1106.7.3.1, 1106.7.3.2.1, 1106.8.2, 1106.8.5, 1107.2, 1107.2.1, 1107.2.2, 1107.2.2.1, 1107.2.2.2, 1107.2.2.3, 1107.2.2.5, 1107.2.2.7.3, 1107.2.2.7.5, 1107.2.2.7.6, 1107.2.2.8.1, 1107.2.2.8.1.1, 1107.2.2.8.2, 1107.2.2.8.2.1, 1107.2.2.9, 1107.2.3, 1107.2.3.1, 1107.2.3.2, 1107.2.3.3, 1107.2.3.4, 1107.2.3.5, 1107.2.4, 1107.2.5, 1107.2.6, 1107.2.7, 1107.2.8, 1107.3.1, 1107.4, 1107.6.1.3, 1108.2.2, 1108.2.3, 1108.2.5, 1108.2.7, 1108.2.9.2, 1108.3, 1108.4.1, 1108.4.1.1, 1108.4.1.2, 1108.4.1.4, 1108.4.1.5, 1109.1, 1109.2, 1109.2.2, 1109.2.4, 1109.3, 1109.4, 1109.5.1, 1109.5.2, 1109.5.3, 1109.6, 1109.7, 1109.7.1, 1109.7.1.1, 1109.8, 1109.8.1, 1109.9.3, 1109.9.3.3, 1109.9.3.4, 1109.10.3, 1109.16, 1109.17, 1110.4.10, 1110.4.11, 1110.4.12, 1111.2, 1111.3, 1111.4, 1111.4.2, 3001.2, 3001.3, 3307.2.6, E101.2, E104.2, E104.2.4, E104.3, E104.3.1, E105.1, E105.2.1, E105.2.2, E105.4, E105.5, E105.6, E106.2, E106.3, E106.4, E106.4.9, E106.5, E107.2, E107.3, E109.2.1, E109.2.2.1, E109.2.2.2, E109.2.2.3, E109.2.3, E109.2.5, E109.2.6, E109.2.8, E111.4 ICC 300—12 ICC Standard on Bleachers, Folding and Telescopic Seating and Grandstands 1029.1.1 ICC 400—17 Standard on Design and Construction of Log Structures 2301.2 ICC 500—14 ICC/NSSA Standard on the Design and Construction of Storm Shelters 202 (storm shelter), 423.1, 423.3, 423.4, 1604.5.1, 1604.10 ICC 600—14 Standard for Residential Construction in High-wind Regions 1609.1.1, 1609.1.1.1, 2308.2.4 SBCCI SSTD 11—99 Test Standard for Determining Wind Resistance of Concrete or Clay Roof Tiles 1711.2.1, 1712.2.2, 1504.2.1.1, 1504.2.1.2
IEC International Electrotechnical Commission IEC Central Office 3, rue de Varembe, P.O. Box 131 1211 Geneva 20 Switzerland Standard reference number Title Referenced in code section number IEC 60118-4 – 2014-12 Electroacoustics - Hearing aids, Part 4 N102.1 IEC 62489-1 – 2010-01 Electroacoustics - Audio-frequency induction loop systems for assisted hearing, Part 1 N102.1
ISO International Organization for Standardization ISO Central Secretariat 1 ch, de la Voie-Creuse, Case Postale 56 CH-1211 Geneva 20, Switzerland Standard reference number Title Referenced in code section number ISO 8115—86 Cotton Bales—Dimensions and Density Table 307.1(1), Table 415.11.1.1.1 ISO 8336—09 Fiber-Cement Flat Sheets - Product Specification and Test Methods 1404.10, 1405.16.1, 1405.16.2, Table 2509.2
ITU International Telecommunication Union (ITU): Place des Nations 1211 Geneva 20 Switzerland Standard reference number Title Referenced in code section number ITU-T, Recommendation E.161—2001 Arrangement of digits, letters and symbols on telephones and other devices that can be used for gaining access to a telephone network 1109.7.2.2.4.1
NAAMM National Association of Architectural Metal Manufacturers 800 Roosevelt Road, Bldg. C, Suite 312 Glen Ellyn, IL 60137 Standard reference number Title Referenced in code section number FP 1001—17 Guide Specifications for Design of Metal Flag Poles 1609.1.1
NCMA National Concrete Masonry Association 13750 Sunrise Valley Herndon, VA 22071-4662 Standard reference number Title Referenced in code section number TEK 5—84(1996) Details for Concrete Masonry Fire Walls Table 721.1(2)
NFPA National Fire Protection Association 1 Batterymarch Park Quincy, MA 02169-7471 Standard reference number Title Referenced in code section number 2—16 Hydrogen Technologies Code 421.4 13—16* * As modified in Appendix Q Installation of Sprinkler Systems 705.8.2, 712.1.3.1, 901.1.1, 903.3.1.1, 903.3.2, 903.3.5.1, 903.3.8.2, 903.3.8.5, 905.3.3.1, 907.6.3, 1019.3, 1705.29.1, K1, Q101.1, Q102.1, Q105.1 13D—16* * As modified in Appendix Q Standard for the Installation of Sprinkler Systems in One- and Two-family Dwellings and Manufactured Homes 901.1.1, 903.2.11.4, 903.3.1.3 903.3.5.1.1, Q101.1, Q102.1, Q103.1 13R—16* * As modified in Appendix Q Standard for the Installation of Sprinkler Systems in Low Rise Residential Occupancies 901.1.1, 903.2.11.4, 903.3.1.2, 903.3.5.1, 903.3.5.1.1, 903.4 Q101.1, Q104.1, Q105.1 14—16* * As modified in Appendix Q Standard for the Installation of Standpipe and Hose System 403.3.2, 901.1.1, 905.2, 905.3.3.3, 905.4.2, 905.6.2, 905.8, 1705.30, 3202.2.4, 3303.8.1, G304.1.2, G308.9, G308.10, G308.11, G402, Q101.1, Q102.1, Q105.1 20—16* * As modified in Appendix Q Standard for the Installation of Stationary Pumps for Fire Protection 901.1.1, 913.1, 913.2, 913.2.1, 913.5, 1705.30.2, Q101.1, Q105.1, Q106.1 22—13 Standard for Water Tanks for Private Fire Protection Q105.1 25—14 Standard for the Inspection, Testing, and Maintenance of Water-based Fire Protection Systems Q102.1 30—12 Flammable and Combustible Liquids Code 415.6, 507.8.1.1.1, 507.8.1.1.2 31—11 Standard for the Installation of Oil-burning Equipment 2113.15 32—11 Standard for Dry Cleaning Plants 415.9.3 40—11 Standard for the Storage and Handling of Cellulose Nitrate Film 409.1 45—15 Standard on Fire Protection for Laboratories Using Chemicals 427.2, 427.7.1 54—16 National Fuel Gas Code 2113.1 58—14 Liquefied Petroleum Gas Code 415.9.2 61—13 Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Product Facilities 426.1 69—14 Standard on Explosion Prevention Systems 426.1 72—16* * As modified in Appendix Q National Fire Alarm Code 407.4.4.3, 407.4.4.5, 407.4.4.5.1, 411.5, 505.2.3, 901.1.1, 901.6, 903.4.1, 904.3.5, 907.1, 907.2, 907.2.1.1, 907.2.2, 907.2.7, 907.2.8.4, 907.2.11, 907.2.12.1, 907.2.13.3, 907.3, 907.3.3, 907.3.4, 907.5.2.1.2, 907.5.2.2, 907.6, 907.6.1, 907.6.5, 907.7, 907.7.1, 907.7.2, 911.1.5, 911.1.6, 911.2, 915.7, 916.1, 3005.5, 3007.7 Q101.1, Q102.1, Q107.1 80—13 Standard for Fire Doors and Other Opening Protectives 410.3.5, 509.4.2, 713.7, 716.5, 716.5.7, 716.5.8.1, 716.5.9.2, 716.6, 716.6.4, 1010.1.4.3 82—14 Standard on Incinerators and Waste and Linen Handling Systems and Equipment 713.13 85—15 Boiler and Combustion System Hazards Code 426.1 92—18* * As modified in Appendix Q Standard for Smoke Control Systems 901.1.1, 909.7, 909.8, 909.10.1, Q101.1, Q108.1 99—15 Health Care Facilities Code 908.8, 407.10, 425.1 101—15 Life Safety Code 1029.6.2 105—13 Standard for Smoke Door Assemblies and Other Opening Protectives 405.4.2, 710.5.2.2, 716.5.3.1, 909.20.4.1 110—13 Standard for Emergency and Standby Power Systems 1705.36, 2702.1, 2702.4.2 111—13 Standard on Stored Electrical Energy Emergency and Standby Power Systems 1704.31, 1705.36, 2702.1 120—15 Standard for Fire Prevention and Control in Coal Mines 426.1 170—15 Standard for Fire Safety and Emergency Symbols 1025.2.6.2 1025.3.1 1025.6.1 211—13 Standard for Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances 2112.5 221—15 Standard for High Challenge Fire Walls, Fire Walls, and Fire Barrier Walls 706.2 252—12 Standard Methods of Fire Tests of Door Assemblies 715.4.2, 715.4.3, 715.4.7.3.1, Table 716.3, 716.3.1, 716.4, 716.5.1, 716.5.2, 716.5.3, 716.5.5.1, 716.5.8.1.1 253—15 Standard Method of Test for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source 406.8.3, 424.2, 804.2 255—06 Standard Method of Test Surface Burning Characteristics of Building Materials K1 257—12 Standard for Fire Test for Window and Glass Block Assemblies Table 716.3, 716.3.2, 716.4, 716.5.3.2, 716.6, 716.6.1, 716.6.2, 716.6.7.3 259—13 Standard Test Method for Potential Heat of Building Materials 2603.4.1.10, 2603.5.3 265—11 Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Wall Coverings on Full Height Panels and Walls 803.1.3, 803.1.3.1 268—12 Standard Test Method for Determining Ignitability of Exterior Wall Assemblies Using a Radiant Heat Energy Source 1406.2.1.1, 1406.2.1.1.1, 1406.2.1.1.2, 2603.5.7 269—12 Standard Test Method for Developing Toxic Potency Data for Use in Fire Hazard Modeling 803.14 276—11 Standard Method of Fire Tests for Determining the Heat Release Rate of Roofing Assemblies With Combustible Above-Deck Roofing Components 1508.1, 2603.3, 2603.4.1.5 285—12 Standard Fire Test Method for the Evaluation of Fire Propagation Characteristics of Exterior Nonload-bearing Wall Assemblies Containing Combustible Components 1401.2, 1403.5, 1403.5.1, 1407.11, 1409.11, 2601.2.1, 2603.5.5 286—15 Standard Methods of Fire Test for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth 402.6.4.4, 803.1.2, 803.1.2.1, 803.11, 2603.7.2, 2603.9, 2604.2.4, 2614.4 288—12 Standard Methods of Fire Tests of Horizontal Fire Door Assemblies Installed in Fire-resistance-rated Floor Systems 712.1.13.1 289—13 Standard Method of Fire Test for Individual Fuel Packages 402.6.2, 424.2 409—11 Standard for Aircraft Hangars 412.4.6, Table 412.4.6, 412.4.6.1, 412.6.5 418—11 Standard for Heliports 412.8.4 484—15 Standard for Combustible Metals 426.1 654—13 Standard for the Prevention of Fire & Dust Explosions from the Manufacturing, Processing and Handling of Combustible Particulate Solids 426.1 655—12 Standard for the Prevention of Sulfur Fires and Explosions 426.1 664—12 Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities 426.1 701—10 Standard Method of Fire Tests for Flame-Propagation of Textiles and Films 424.2, 3102.3.1, 3102.6.1.1, 3105.3, 3301.9.1.3, 3301.9.2.3, 3307.2.3, 3307.4.7, 3308.3.4, 3314.8.2, 3315.1.6, 3315.2.3, H114.2, H114.2.2, H117.4 704—12 Standard System for the Identification of the Hazards of Materials for Emergency Response 202 (hazardous production material; laboratory chemical), 415.5.2, 427.4 720—15 Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment 915.5.4, 915.6.1, 915.6.2, 915.7 1124—17 Code for the Manufacture, Transportation and Storage of Fireworks and Pyrotechnic Articles 415.6.1.1
PCI Precast Prestressed Concrete Institute 200 West Adams Street, Suite 2100 Chicago, IL 60606-6938 Standard reference number Title Referenced in code section number MNL 124—11 Design for Fire Resistance of Precast Prestressed Concrete 722.2.3.1 MNL 128—01 Recommended Practice for Glass Fiber Reinforced Concrete Panels 1903.3
PTI Post-Tensioning Institute 38800 Country Club Drive Farmington Hills, MI 48331 Standard reference number Title Referenced in code section number PTI DC—35.1-14 Recommendations for Prestressed Rock and Soil Anchors 1815.1, 1815.3, 1815.4.5, 1815.5
RCSC Research Council on Structural Connections One East Wacker Drive, Suite 700 Chicago, IL 60601 Standard reference number Title Referenced in code section number RCSC—14 (2015) Specification for Structural Joints Using High-Strength Bolts Table 1705.2
RMI Rack Manufacturers Institute 8720 Red Oak Boulevard, Suite 201 Charlotte, NC 28217 Standard reference number Title Referenced in code section number ANSI/MH16.1—12 Specification for Design, Testing and Utilization of Industrial Steel Storage Racks 2209.1
SBCA Structural Building Components Association 6300 Enterprise Lane Madison, WI 53719 Standard reference number Title Referenced in code section number ANSI/FS 100-12 Standard Requirements for Wind Pressure Resistance of Foam Plastic Insulating Sheathing Used in Exterior Wall Covering Assemblies 2603.10
SDI Steel Deck Institute P. O. Box 426 Glenshaw, PA 15116 Standard reference number Title Referenced in code section number NC—17 Standard for Noncomposite Steel Floor Deck 2210.1.1.1 RD—17 Standard for Steel Floor Deck 2210.1.1.2 SDI-C—2017 Standard for Composite Steel Floor Deck Slabs 2210.1.1.3 SDI-QA/QC—2017 Standard for Quality Control and Quality Assurance for Installation of Steel Deck 1705.2.1.2
SJI Steel Joist Institute 1173B London Links Drive Forest, VA 24551 Standard reference number Title Referenced in code section number SJI 100—15 Standard Specification Load Tables and Weight Tables for Steel Joists and Joist Girders K-Series, LH-Series, DHL-Series, Joist Girders - 44th Edition 1604.3.3, 2203.2, 2207.1 SJI 200—15 Standard Specification for Composite Steel Joists - CJ-Series 1604.3.3
SPRI Single-Ply Roofing Institute 411 Waverly Oaks Road, Suite 331B Waltham, MA 02452 Standard reference number Title Referenced in code section number ANSI/SPRI/FM 4435-ES-1—11 Wind Design Standard for Edge Systems Used with Low Slope Roofing Systems 1504.5 ANSI/SPRI RP-4—13 Wind Design Guide for Ballasted Single-ply Roofing Systems 1504.4 ANSI/SPRI VF1—10 External Fire Design Standard for Vegetative Roofs 1507.16.1 RP-14—16 Wind Design Standards for Vegetative Roofing Systems 1507.16.1
TIA Telecommunications Industry Association 1320 N. Courthouse Road Arlington, VA 22201-3834 Standard reference number Title Referenced in code section number 222-G—05 Structural Standards for Antenna Supporting Structures and Antennas, including—Addendum 1, 222-G-1, Dated 2007, Addendum 2, 222-G-2 Dated 2009, Addendum 3, 222-3 dated 2013 and Addendum 4, 222-G-4 dated 2014 1609.1.1 TIA-222-H—17 Standard for Antennas and the Supporting Structures for Antennas and Small Wind Turbines 1609.1.1, 3108.1, 3108.2, 3108.4
TMS The Masonry Society 105 South Sunset Street, Suite Q Longmont, CO 80501 Standard reference number Title Referenced in code section number 216—2013 Standard Method for Determining Fire Resistance of Concrete and Masonry Construction Assemblies Table 721.1(2), 722.1 302—2012 Standard Method for Determining the Sound Transmission Class for Masonry Walls 1207.2.1 402—2016* * As modified in Chapter 21 Building Code Requirements and Specifications for Masonry Structures 1405.6, 1405.6.2, 1405.10, 1604.3.4, 1705.4.1, Table 1705.4.1, 1705.4.3, Table 1705.4.3 2101.2, 2104.1, 2106.1, 2107.1, 2107.2, 2107.3, 2107.4, 2108.1, 2108.2, 2108.3, 2109.1, 2109.1.1, 2109.1.1.1, 2109.2, 2109.2.1, 2110.1 403—2017 Direct Design Handbook for Masonry Structures 2101.2 404—2016 Standard for the Design of Architectural Cast Stone 2101.2 504—2016 Standard for the Fabrication of Architectural Cast Stone 2103.1 602—2016 Specification for Masonry Structures 1405.6.1, Table 1705.4.1, Table 1705.4.3, 2103.1, 2103.2.1, 2103.3, 2103.4, 2104.1, 2104.2, 2104.3, 2104.5, 2105.1, 2105.2 604—2016 Standard for the Installation of Architectural Cast Stone 2104.1
TPI Truss Plate Institute 218 N. Lee Street, Suite 312 Alexandria, VA 22314 Standard reference number Title Referenced in code section number TPI 1—2014 National Design Standard for Metal-plate-connected Wood Truss Construction 2303.4.6, 2306.1
UL UL LLC 333 Pfingsten Road Northbrook, IL 60062-2096 Standard reference number Title Referenced in code section number 9—2009 Fire Tests of Window Assemblies Table 716.3, 716.3.2, 716.4, 716.5.3.2, 716.6, 716.6.1, 716.6.2, 716.6.8.1 10A—2009 Tin Clad Fire Doors 716.5 10B—2008 Fire Tests of Door Assemblies—with Revisions through April 2009 Table 716.3, 716.5.2, 716.5.5.1, 716.5.8.1.1. 10C—2009 Positive Pressure Fire Tests of Door Assemblies 716.5.1, 716.5.3, 716.5.5.1, 716.5.8.1.1, 1010.1.10.1 14B—2008 Sliding Hardware for Standard Horizontally mounted Tin Clad Fire Doors—with Revisions Through May 3, 2013 716.5 14C—06 Swinging Hardware for Standard Tin Clad Fire Doors Mounted Singly and in Pairs—with Revisions through May 2013 716.5 55A—04 Materials for Built-Up Roof Coverings 1507.10.2 103—2010 Factory-built Chimneys, for Residential Type and Building Heating Appliances—with Revisions through July 2012 718.2.5.1 127—2011 Factory-built Fireplaces 718.2.5.1, 2111.12 214—01 Standard for Tests for Flame-propagation of Fabrics and Films 3301.9.1.3, 3301.9.2.3, H114.2, H117.4 217—16 Single and Multiple Station Smoke Alarms, 8th Edition 907.2.11, 907.2.11.6, 915.5.3 263—11 Standard for Fire Tests of Building Construction and Materials 703.2, 703.2.1, 703.2.3, 703.2.5, 703.3, 703.4, 703.6, 704.12, 705.7, 705.8.5, 707.6, 712.1.13.2, 714.1, 715.5.1, 716.2, Table 716.3, 716.5.6, 716.5.8.1.1, Table 716.6, 716.6.7.1, 717.3.1, 717.5.2, 717.5.3, 717.6.1, 717.6.2.1, Table 721.1(1), 1407.10, 1409.10, 2103.1, 2603.4, 2603.5.1, 2603.5.2 268—16 Smoke Detectors for Fire Alarm Systems, 7th Edition 407.8, 907.2.11.6, 907.2.11.7, 915.6.3 294—1999 Access Control System Units—with Revisions through September 2010 1010.1.9.6, 1010.1.9.7, 1010.1.9.8, 1010.1.9.9 300—05 (R2010) Fire Testing of Fire Extinguishing Systems for Protection of Commercial Cooking Equipment—with Revisions through July 16, 2010 904.12 300A—06 Outline of Investigation for Extinguishing System Units for Residential Range Top Cooking Surfaces 407.2.6, 904.13 305—2012 Panic Hardware 1010.1.10.3 325—02 Door, Drapery, Gate, Louver and Window Operations and Systems— with Revisions through June 2013 3110.3.1, 3110.4, 406.3.5 555—2006 Fire Dampers—with Revisions through May 2012 717.3.1 555C—2006 Ceiling Dampers—with Revisions through May 2010 717.3.1 555S—99 Smoke Dampers—with Revisions through May 2012 717.3.1 580—2006 Test for Uplift Resistance of Roof Assemblies—with Revisions through July 2009 1504.3.1, 1504.3.2 641—2010 Type L Low-temperature Venting Systems—with Revisions through June 2013 2113.11.1.4 723—2008 Standard for Test for Surface Burning Characteristics of Building Materials—with Revisions through September 2010 202, (flame spread index), 402.6.4.4, 402.6.2, 703.5.2, 720.1, 803.1.1, 803.1.2, 803.1.4, 803.10, 803.11, 806.7, 1404.12.1, 1407.9, 1409.9, 1409.10.1, 1510.10.3, 2303.2, 2603.3, 2603.4.1.13, 2606.3.5.4, 2606.3.5.5, 2603.7, 2603.7.1, 2603.7.2, 2603.7.3, 2604.2.4, 2606.4, 2612.3, 2614.3, 3105.3, K1 790—04 Standard Test Methods for Fire Tests of Roof Coverings—with Revisions through October 2008 1505.1, 2603.6, 2610.2, 2610.3 793—08 Standards for Automatically Operated Roof Vents for Smoke and Heat—with Revisions through September 2011 910.3.1 864—03 Standards for Control Units and Accessories for Fire Alarm Systems—with Revisions through December 2014 406.8.5.1.1, 909.12, 909.12.4.1 924—06 Standard for Safety Emergency Lighting and Power Equipment—with Revisions through February 2011 1013.5 1040—96 Fire Test of Insulated Wall Construction—with Revisions through October 2012 2603.4, 2603.5.2, 2603.9 1256—02 Fire Test of Roof Deck Construction—with Revisions through January 2007 1508.1, 2603.3, 2603.4.1.5 1275—05 Flammable Liquid Storage Cabinets 427.4 1479—03 Fire Tests of Through-penetration Firestops—with Revisions through October 2012 202 (F rating, L rating, T rating, through- penetration firestop system), 714.3.1.2, 714.3.2, 714.4.1.2, 714.4.3 1482—2011 Solid-Fuel-type Room Heaters—with Revisions through August 2015 2112.2 1703—02 Flat-Plate Photovoltaic Modules and Panels 1505.9, 1507.17.6, 1510.11.4 1715—97 Fire Test of Interior Finish Material—with Revisions through January 2013 1407.10, 1409.10, 2603.4, 2603.5.2, 2603.9, 2614.4 1777—2007 Chimney Liners—with Revisions through October 2015 2113.11.1, 2113.19 1784—01 Air Leakage Tests of Door Assemblies—with Revisions through July 2009 710.5.2.2, 710.5.2.2.1, 716.5.3.1, 716.5.7.1, 1016.3.1, 1016.3.2, 3006.1.1, 3007.6, 3007.6.3, 3008.7.3 1897—12 Uplift Tests for Roof Covering Systems 1504.3.1 1975—06 Fire Test of Foamed Plastics Used for Decorative Purposes 402.6.2, 402.6.4.5, 424.2 1994—04 Standard for Luminous Egress Path Marking Systems—with Revisions through November 2010 411.7, 1025.2.1, 1025.2.3, 1025.2.4, 1025.4 2017—2008 Standards for General-purpose Signaling Devices and Systems—with Revisions through May 2011 3109.5.1.8 406.8.5.1.1 2034—08 Standard for Single- and Multiple-Station Carbon Monoxide Alarm—with Revisions through March 2015 915.5.2, 915.5.3 2075—2013 Standard for Gas and Vapor Detectors and Sensors 406.8.5.1.1, 915.6.1, 915.6.3 2079—04 Tests for Fire Resistance of Building Joint Systems—with Revisions through December 2012 202 (fire-resistant joint system, l rating), 715.3, 715.6 2196—2017 Tests for Fire Resistive Cables 909.20.6.1 2200—2012 Stationary Engine Generator Assemblies—with Revisions through June 2013 2702.1.2, 2702.4.1
ULC Underwriters Laboratories of Canada 7 Underwriters Road Toronto, Ontario, Canada M1R3B4 Standard reference number Title Referenced in code section number CAN/ULC S 102.2—2010 Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings and Miscellaneous Materials and Assemblies—with 2000 Revisions 720.2, 720.3, 720.4 CAN/ULC S635—16 Standard for Lining Systems for Existing Masonry or Factory-built Chimneys and Vents 2113.11.1.2, 2113.19
USC United States Code c/o Superintendent of Documents U.S. Government Printing Office 732 North Capitol Street NW Washington, DC 20401 Standard reference number Title Referenced in code section number 18 USC Part 1, Ch.40 Importation, Manufacture, Distribution and Storage of Explosive Materials 202 (explosive)
WCLIB West Coast Lumber Inspection Bureau P. O. Box 23145 Portland, OR 97281 Standard reference number Title Referenced in code section number AITC 104—03 Typical Construction Details 2306.1 AITC 110—01 Standard Appearance Grades for Structural Glued Laminated Timber 2306.1 AITC 113—10 Standard for Dimensions of Structural Glued Laminated Timber 2306.1 AITC 117—15 Standard Specifications for Structural Glued Laminated Timber of Softwood Species 2306.1 AITC 119—96 Standard Specifications for Structural Glued Laminated Timber of Hardwood Species 2306.1 AITC 200—09 Manufacturing Quality Control Systems Manual for Structural Glued Laminated Timber 2306.1
WDMA Window and Door Manufacturers Association 2025 M Street, NW Suite 800 Washington, DC 20036-3309 Standard reference number Title Referenced in code section number AAMA/WDMA/CSA 101/I.S.2/A440—11 Specifications for Windows, Doors and Unit Skylights 1709.5.1, 2405.5
(Am. L.L. 2023/077, 6/11/2023, eff. 6/11/2023)
Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2008/026, L.L. 2011/021, L.L. 2011/071, L.L. 2011/075, L.L. 2013/112, L.L. 2014/051, and L.L. 2023/077.
Section BC D101. General
D101.1 Scope.
The provisions of this appendix shall regulate the division of the city of New York into geographical territories known as fire districts and control the occupancy groups and construction classes permitted in the fire districts. Wherever reference is made to the Fire District, it shall be construed to mean the fire districts designated and referred to in this appendix.
D101.2 Establishment of fire district.
The following city areas are hereby established as being inside the fire districts:
1. All of the borough of Manhattan.
2. All of the borough of Bronx.
3. All of the borough of Brooklyn.
4. Such portions of the boroughs of Staten Island and Queens as are indicated on the "fire district maps" as per Section D106.
Section BC D102. Building Restrictions
D102.1 Types of construction permitted.
Every building hereafter erected within the fire district, or located partially in the fire district pursuant to Section D104.1, shall be either Type I, II, III or IV.
D102.2 Other specific requirements.
D102.2.1 Group H-1 prohibited.
Group H-1 occupancies shall be prohibited from location within the fire district.
D102.2.2 Construction type.
Every building, room, or space hereafter altered or erected shall be constructed as required based on the type of construction indicated in Chapter 6 except as provided in Section D102.2.4.
D102.2.3 Roof covering.
Roof covering in the fire district shall conform to the requirements of Class A or B roof coverings as defined in Section 1505.
D102.2.4 Structural fire rating.
The fire-resistance rating of bearing walls, floors, roofs and their supporting structural members shall comply with Table 601 of Chapter 6, but in no event shall such rating be less than 1-hour.
Exceptions. The following buildings or building elements may be constructed with fire-resistance rating in accordance with Table 601:
1. Buildings of Type IV construction.
2. Buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1.
3. Automobile parking structures.
4. Buildings surrounded on all sides by a permanently open space of not less than 30 feet (9144 mm).
5. Partitions complying with Section 603.1, Item 11.
D102.2.5 R-1 and R-2 Occupancies.
No building or space classified in Occupancy Group R-1 or R-2 may be located on a lot containing a building classified in construction Type IIB, VA or VB.
Section BC D103. Changes to Buildings
D103.1 Existing buildings within the fire district.
An existing building shall not hereafter be increased in height or area unless it is of a type of construction permitted for new buildings within the fire district or is altered to comply with the requirements for such type of construction. Nor shall any existing building be hereafter extended on any side, nor square footage or floors added within the existing building unless such modifications are of a type of construction permitted for new buildings within the fire district.
D103.2 Other alterations.
Nothing in Section D103.1 shall prohibit other alterations within the fire district provided there is no change of occupancy that is otherwise prohibited and provided the fire hazard is not increased by such alteration.
D103.3 Moving buildings.
Buildings shall not hereafter be moved into the fire district or to another lot in the fire district unless the building is of a type of construction permitted in the fire district.
Section BC D104. Buildings Located Partially In the Fire District
D104.1 General.
Any building located partially in the fire district, so that it is both inside and outside the district, shall be of a type of construction required for the fire district if more than 25 percent of the total floor area of the building is located inside the fire district.
Section BC D105. Exceptions to Restrictions in Fire District
D105.1 General.
The preceding provisions of this appendix shall not apply in the following instances:
1. Temporary platforms, reviewing stands, and similar miscellaneous structures used for a limited period of time, subject to the approval of the commissioner.
2. Fences not over 6 feet (1829 mm) high.
3. Water towers, tank structures, and trestles may be constructed of wood planking and timbers of dimensions not less than as required for Type IV construction when not over 35 feet (10 668 mm) high and having an exterior separation of at least 30 feet (9144 mm).
4. Detached greenhouses accessory to a one- or two-family dwelling located on the same lot at least 6 feet (1829 mm) from any lot line or building walls and not exceeding 14 feet (4267 mm) in height.
5. Porches on dwellings not over one story in height, and not over 10 feet (3048 mm) wide from the face of the building, provided such porch does not come within 5 feet (1524 mm) of any property line.
6. Sheds open on a long side not over 15 feet (4572 mm) high and 500 square feet (46 m 2 ) in area.
7. Existing one- and two-family dwellings of a type of construction not permitted in the fire district can be extended 25 percent of the floor area existing at the time of inclusion in the fire district by any type of construction permitted by this code.
8. Wood decks less than 600 square feet (56 m 2 ) where constructed of 2-inch (51 mm) nominal wood, pressure treated for exterior use.
9. 9. One- or two-family detached or semidetached dwellings of two stories or less in height and 2,500 square feet (232 m 2 ) or less in area per story located within Zoning Districts R-2 through R-5 may be constructed or reconstructed of construction Type VA, or if damaged for any cause only the damaged portions shall be required to be reconstructed to conform to Type VA construction. In addition, one-family dwellings located within Zoning District R-1 anywhere in the city, may be constructed of Type VB construction in conformance with the area and height limits established by Tables 504.3, 504.4 and 506.2 of this code.
10. An accessory building or structure used as an office or similar use for an open parking lot located on the same lot, may be constructed of Type VA or VB construction provided its area shall be limited to 150 square feet (14 m 2 ) and height of 10 feet (3048 mm) maximum. Such structure shall be located not less than 6 feet (1829 mm) from any lot line or buildings on the same lot.
11. Temporary fences, sidewalk sheds, signs, and other safeguards installed in accordance with Chapter 33.
12. One- or two-family detached, zero lot line or semi-detached dwellings of three stories in height and 2,500 square feet (232 m 2 ) or less in area per story located within Zoning Districts R-1 through R-5 within Lower Density Growth Management Areas as defined by the New York City Zoning Resolution may be constructed or reconstructed of construction Type VA where such buildings are equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1, or if damaged for any cause only the damaged portions shall be required to be reconstructed to conform to Type VA construction where such buildings are equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. In addition, no portion of a one- or two-family detached, zero lot line or semi-detached dwellings located within Zoning Districts R-1, R-2 or R-5 within Lower Density Growth Management Areas shall exceed a maximum building height of 35 feet (10 668 mm) above the grade plane.
Section BC D106. Fire District Maps for the Boroughs of Staten Island (Richmond County) and Queens
This section has 41 pictures (figures, equations, or tables drawn as images) that BetaNYC's copy does not show. Read Section BC D106 at American Legal Publishing.
D106.1 Fire district maps.
Within the boroughs of Staten Island (Richmond County) and Queens, the fire districts shall comprise such areas indicated on the "fire district maps" as per Figures D106.1(1) and D106.1(2).
Figure D106.1(1) Fire District Maps Borough of Staten Island (Richmond County)
Figure D106.1(2) Fire District Maps Borough of Queens
Section BC E101. General
E101.1 Scope.
The provisions of this appendix shall control the supplementary requirements for the design and construction of facilities for accessibility for individuals with disabilities.
E101.2 Design.
Technical requirements for items herein shall comply with this code and ICC A117.1.
Section BC E102. Definitions
E102.1 General.
The following terms are defined in Chapter 2:
CLOSED-CIRCUIT TELEPHONE.
MAILBOXES.
TRANSIENT LODGING.
Section BC E103. Accessible Route
E103.1 Raised platforms.
In banquet rooms or spaces where a head table or speaker's lectern is located on a raised platform, an accessible route shall be provided to the platform.
Section BC E104. Special Occupancies
E104.1 General.
Transient lodging facilities shall be provided with accessible features in accordance with Sections E104.2 and E104.3. Group I-3 occupancies shall be provided with accessible features in accordance with Sections E104.2 and E104.4.
E104.2 Communication features.
Accessible communication features complying with Chapter 7 of ICC A117.1 shall be provided in accordance with Sections E104.2.1 through E104.2.4 of this code.
E104.2.1 Transient lodging.
In transient lodging facilities, sleeping units with accessible communication features shall be provided in accordance with Table E104.2.1. Units required to comply with Table E104.2.1 shall be dispersed among the various classes of units.
Table E104.2.1 Dwelling or Sleeping Units with Accessible Communication Features
Total Number of Dwelling or Sleeping Units Provided Minimum Required Number of Dwelling or Sleeping Units with Accessible Communication Features 1 1 2 to 25 2 26 to 50 4 51 to 75 7 76 to 100 9 101 to 150 12 151 to 200 14 201 to 300 17 301 to 400 20 401 to 500 22 501 to 1,000 5% of total 1,001 and over 50 plus 3 for each 100 over 1,000
E104.2.2 Group I-3.
In Group I-3 occupancies at least 2 percent, but no fewer than one of the total number of general holding cells and general housing cells equipped with audible emergency alarm systems and permanently installed telephones within the cell, shall comply with Section E104.2.4.
E104.2.3 Dwelling units and sleeping units.
Where dwelling units and sleeping units are altered or added, the requirements of Section E104.2 shall apply only to the units being altered or added until the number of units with accessible communication features complies with the minimum number required for new construction.
E104.2.4 Notification devices.
Visual notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell. Notification devices shall not be connected to visual alarm signal appliances. Permanently installed telephones shall have volume controls and an electrical outlet complying with ICC A117.1, including Section 309 (Operable Parts), located within 48 inches (1219 mm) of the telephone to facilitate the use of a TTY.
E104.3 Accessible beds.
In rooms or spaces having more than 25 beds, five percent of the beds shall have a clear floor space complying with Section 305 (Clear Floor Space) of ICC A117.1.
E104.3.1 Sleeping areas.
A clear floor space complying with Section 305 (Clear Floor Space) of ICC A117.1 shall be provided on both sides of the accessible bed. The clear floor space shall be positioned for parallel approach to the side of the bed.
Exception: This requirement shall not apply where a single clear floor space complying with Section 305 (Clear Floor Space) of ICC A117.1 positioned for parallel approach is provided between two beds.
E104.4 Partitions.
Solid partitions or security glazing that separates visitors from detainees in Group I-3 occupancies shall provide a method to facilitate voice communication. Such methods are permitted to include, but are not limited to, grilles, slats, talk-through baffles, intercoms or telephone handset devices. The method of communication shall be accessible to individuals who use wheelchairs and individuals who have difficulty bending or stooping. Hand-operable communication devices, if provided, shall comply with Section E106.3.
Section BC E105. Other Features and Facilities
E105.1 Portable toilets and bathing rooms.
Where multiple single-user portable toilet or bathing units are clustered at a single location, at least 5 percent, but not less than one toilet unit or bathing unit at each cluster, shall be accessible and comply with ICC A117.1, including Section 603 (Toilet and Bathing Rooms). Signs containing the dynamic accessibility symbol and complying with Section 703 (Signs) of ICC A117.1 shall identify accessible portable toilets and bathing units.
Exception: Portable toilet units provided for use exclusively by construction personnel on a construction site.
E105.2 Laundry equipment.
Where provided in spaces required to be accessible, washing machines and clothes dryers shall comply with this section. Where laundry equipment is provided within a dwelling or sleeping unit, not for public use or common use, such equipment shall comply with Section 1107.2.8.
E105.2.1 Washing machines.
Where three or fewer washing machines are provided, at least one shall comply with ICC A117.1, including Section 611 (Washing Machines and Clothes Dryers), and shall be accessible. Where more than three washing machines are provided, at least two shall comply with ICC A117.1, including Section 611 and shall be accessible.
E105.2.2 Clothes dryers.
Where three or fewer clothes dryers are provided, at least one shall comply with ICC A117.1, including Section 611 (Washing Machines and Clothes Dryers), and shall be accessible. Where more than three clothes dryers are provided, at least two shall comply with ICC A117.1, including Section 611, and shall be accessible.
E105.3 Depositories, vending machines, change machines and similar equipment.
At least one of each type of depository, vending machine, change machine and similar equipment shall be accessible.
Exception: Drive-up-only depositories are not required to comply with this section.
E105.4 Mailboxes.
Where mailboxes are provided in facilities not subject to Section 1107.3.1, but required to be accessible pursuant to the Americans with Disabilities Act, at least five percent, but not less than one, of each type shall comply with ICC A117.1.
E105.5 Automatic teller machines and fare machines.
Where automatic teller machines or self-service fare vending, collection or adjustment machines are provided, at least one machine of each type at each location where such machines are provided shall be accessible and comply with ICC A117.1, including Section 707 (ATMs and Fare Machines). Where bins are provided for envelopes, wastepaper or other purposes, at least one of each type shall be accessible and comply with ICC A117.1, including Section 905 (Storage Facilities).
E105.6 Two-way communication systems.
Where two-way communication systems are provided to gain admittance to a building or facility or to restricted areas within a building or facility, the system shall be accessible and comply with ICC A117.1, including Section 708 (Two-Way Communication Systems).
Section BC E106. Telephones
E106.1 General.
Where coin-operated public pay telephones, coinless public pay telephones, public closed-circuit telephones, courtesy phones or other types of public telephones are provided, accessible public telephones shall be provided in accordance with Sections E106.2 through E106.5 for each type of public telephone provided. For purposes of this section, a bank of telephones shall be considered two or more adjacent telephones.
E106.2 Wheelchair-accessible telephones.
Where public telephones are provided, wheelchair-accessible telephones complying with ICC A117.1, including Section 704 (Telephones), shall be provided in accordance with Table E106.2.
Exception: Drive-up-only public telephones are not required to be accessible.
Table E106.2 Wheelchair-Accessible Telephones
Number of Telephones Provided on a Floor, Level or Exterior Site Minimum Required Number of Wheelchair-Accessible Telephones 1 or more single unit 1 per floor, level and exterior site 1 bank 1 per floor, level and exterior site 2 or more banks 1 per bank
E106.3 Volume controls.
All public telephones provided shall have accessible volume control complying with Section 704.3 (Volume-Control Telephones) of ICC A117.1.
E106.4 TTYs.
TTYs complying with ICC A117.1, including Section 704.4 through 704.7, shall be provided in accordance with Sections E106.4.1 through E106.4.9.
E106.4.1 Bank requirement.
Where four or more public pay telephones are provided at a bank of telephones, at least one public TTY shall be provided at that bank.
Exception: TTYs are not required at banks of telephones located within 200 feet (60 960 mm) of, and on the same floor as, a bank containing a public TTY.
E106.4.2 Floor requirement.
Where four or more public pay telephones are provided on a floor of a privately owned building, at least one public TTY shall be provided on that floor. Where at least one public pay telephone is provided on a floor of a publicly owned building, at least one public TTY shall be provided on that floor.
E106.4.3 Building requirement.
Where four or more public pay telephones are provided in a privately owned building, at least one public TTY shall be provided in the building. Where at least one public pay telephone is provided in a publicly owned building, at least one public TTY shall be provided in the building.
E106.4.4 Site requirement.
Where four or more public pay telephones are provided on a site, at least one public TTY shall be provided on the site.
E106.4.5 Rest stops, emergency road stops and service plazas.
Where a public pay telephone is provided at a public rest stop, emergency road stop or service plaza, at least one public TTY shall be provided.
E106.4.6 Hospitals.
Where a public pay telephone is provided in or adjacent to a hospital emergency room, hospital recovery room or hospital waiting room, at least one public TTY shall be provided at each such location.
E106.4.7 Transportation facilities.
Transportation facilities shall be provided with TTYs in accordance with Section E109.2.5 in addition to the TTYs required by Sections E106.4.1 through E106.4.4.
E106.4.8 Detention and correctional facilities.
In detention and correctional facilities, where a public pay telephone is provided in a secured area used only by detainees or incarcerated individuals and security personnel, then at least one TTY shall be provided in at least one secured area.
(Am. 2022 N.Y. Laws Ch. 486, 8/8/2022, eff. 11/7/2022)
E106.4.9 Signs.
Public TTYs shall be identified by the International Symbol of TTY complying with Section 703.6.3.2 (International Symbol of TTY) of ICC A117.1. Directional signs indicating the location of the nearest public TTY shall be provided at banks of public pay telephones not containing a public TTY. Additionally, where signs provide direction to public pay telephones, they shall also provide direction to public TTYs. Such signs shall comply with visual signage requirements in ICC A117.1, including Section 703.2 (Visual Characters) and shall include the International Symbol of TTY.
E106.5 Shelves for portable TTYs.
Where a bank of telephones in the interior of a building consists of three or more public pay telephones, at least one public pay telephone at the bank shall be provided with a shelf and an electrical outlet in accordance with Section 704.6 (TTY Shelf) of ICC A117.1.
Exceptions:
1. In secured areas of detention and correctional facilities, if shelves and outlets are prohibited for purposes of security or safety shelves and outlets for TTYs are not required to be provided.
2. The shelf and electrical outlet shall not be required at a bank of telephones with a TTY.
Section BC E107. Signage
E107.1 Signs.
Required accessible portable toilets and bathing facilities shall be identified by the dynamic accessibility symbol, in accordance with Figure 1111.1.
E107.2 Designations.
Interior and exterior signs identifying permanent rooms and spaces shall have visual characters, raised characters and braille complying with ICC A117.1. Where pictograms are provided as designations of interior rooms and spaces, the pictograms shall have visual characters, raised characters and braille complying with Sections 703.2 through 703.5 of ICC A117.1.
Exceptions:
1. Exterior signs that are not located at the door to the space they serve are not required to comply.
2. Building directories, menus, seat and row designations in assembly areas, occupant names, building addresses and company names and logos are not required to comply.
3. Signs in parking facilities are not required to comply.
4. Temporary (seven days or less) signs are not required to comply.
5. In detention and correctional facilities, signs not located in public areas are not required to comply.
E107.3 Directional and informational signs.
Signs that provide direction to, or information about, permanent interior spaces of the site and facilities shall contain visual characters complying with Section 703.2 (Visual Characters) of ICC A117.1.
Exception: Building directories, personnel names, company or occupant names and logos, menus and temporary (seven days or less) signs are not required to comply with ICC A117.1.
E107.4 Other signs.
Signage indicating special accessibility provisions shall be provided at fixed facilities and stations, signage must be provided in accordance with Sections E109.2.2 through E109.2.2.3.
Section BC E108. Reserved
BetaNYC's copy has no text for this section. Read Section BC E108 at American Legal Publishing.
Section BC E109. Transportation Facilities and Stations
E109.1 General.
Fixed transportation facilities and stations shall comply with the applicable provisions of Section E109.2.
E109.2 New construction.
New stations in rapid rail, light rail, commuter rail, intercity rail, high speed rail and other fixed guideway systems shall comply with Sections E109.2.1 through E109.2.8.
E109.2.1 Station entrances.
Where different entrances to a station serve different transportation fixed routes or groups of fixed routes, all entrance serving each group or route shall comply with Section 1104 and ICC A117.1, including Section 404 (Doors and Doorways).
E109.2.2 Signs.
Signage in fixed transportation facilities and stations shall comply with Sections E109.2.2.1 through E109.2.2.3.
E109.2.2.1 Raised character and braille signs.
Where signs are provided at entrances to stations identifying the station or the entrance, or both, at least one sign at each entrance shall have raised characters and braille. A minimum of one raised character and braille sign identifying the specific station shall be provided on each platform or boarding area. Such signs shall be placed in uniform locations at entrances and on platforms or boarding areas within the transit system to the maximum extent practicable. Raised character and braille signs shall comply with Sections 703.3 (Raised Characters) and 703.4 (Braille) of ICC A117.1.
Exceptions:
1. Where the station has no defined entrance but signs are provided, the raised character and braille signs shall be placed in a central location.
2. Signs are not required to be raised character and braille where audible signs are remotely transmitted to hand-held receivers, or are user or proximity actuated.
E109.2.2.2 Identification signs.
Stations covered by this section shall have identification signs containing visual characters complying with Section 703.2 (Visual Characters) of ICC A117.1. Signs shall be clearly visible and within the sightlines of a standing or sitting passenger from within the train on both sides when not obstructed by another train.
E109.2.2.3 Informational signs.
Lists of stations, routes and destinations served by the station that are located on boarding areas, platforms or mezzanines shall provide visual characters complying with Section 703.2 (Visual Characters) of ICC A117.1. Signs covered by this provision shall, to the maximum extent practicable, be placed in uniform locations within the transit system.
E109.2.3 Fare machines.
Self-service fare vending, collection and adjustment machines shall comply with Section 707 (ATMs and Fare Machines). Where self-service fare vending, collection or adjustment machines are provided for the use of the general public, at least one accessible machine of each type provided shall be provided at each accessible point of entry and exit.
E109.2.4 Rail-to-platform height.
Station platforms shall be positioned to coordinate with vehicles in accordance with the applicable provisions of 36 CFR, Part 1192. Low-level platforms shall be 8 inches (203 mm) minimum above top of rail.
Exception: Where vehicles are boarded from sidewalks or street level, low-level platforms shall be permitted to be less than 8 inches (203 mm).
E109.2.5 TTYs.
Where a public pay telephone is provided in a transit facility (as defined by the Department of Transportation) at least one public TTY complying with ICC A117.1, Sections 704.4 through 704.7, shall be provided in the station. In addition, where one or more public pay telephones serve a particular entrance to a transportation facility, at least one TTY telephone complying with ICC A117.1, Sections 704.4 through 704.7 shall be provided to serve that entrance.
E109.2.6 Track crossings.
Where a circulation path serving boarding platforms crosses tracks, an accessible route complying with ICC A117.1, including Section 402 (Accessible Routes) shall be provided.
Exception: Openings for wheel flanges shall be permitted to be 2 1/2 inches (64 mm) maximum.
E109.2.7 Public address systems.
Where public address systems convey audible information to the public, the same or equivalent information shall be provided in a visual format.
E109.2.8 Clocks.
Where clocks are provided for use by the general public, the clock face shall be uncluttered so that its elements are clearly visible. Hands, numerals and digits shall contrast with the background either light-on-dark or dark-on-light. Where clocks are mounted overhead, numerals and digits shall comply with ICC A117.1, Section 703.2 (Visual Characters).
Section BC E110. Reserved
BetaNYC's copy has no text for this section. Read Section BC E110 at American Legal Publishing.
Section BC E111. Referenced Standards
E111.1 General.
This section lists the standards that are referenced in various sections of this appendix. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title and the section or sections of this document that reference the standard.
E111.2 Subsequent additions, modifications, or deletions.
Refer to the rules of the department for any subsequent additions, modifications or deletions that may have been made to these standards in accordance with Section 28-103.19 of the Administrative Code.
E111.3 Applicability.
The application of the referenced standards shall be as specified in Section 102.4.
E111.4 Standards.
DOJ 36CFR Part 1192 Americans with Disabilities Act (ADA) Accessibility Guidelines for Transportation Vehicles (ADAAG). Washington, D.C.: Department of Justice, 1991 E109.2.4 ICC A117.1-2009 Accessible and Usable Buildings and Facilities E101.2, et al.
Section BC F101. General
F101.1 Scope.
The provisions of this appendix provide rodent-proofing design and construction requirements for the resistance of rodent ingress and infestation. For rodent extermination provisions related to demolition operations, see Section 3306. The New York City Health Code, The New York City Housing Maintenance Code, and The New York City Sanitation Code may contain additional provisions, as enforced by the New York City Department of Health and Mental Hygiene, the New York City Department of Housing Preservation and Development, and the New York City Sanitation Department.
F101.2 General.
Every structure, room, or space hereafter altered or erected in which persons live, sleep or work, or in which feed, food or foodstuffs are stored, prepared, processed, served or sold, shall be constructed in accordance with the provisions of this section. All metal or wire protection materials specified herein shall be noncorrosive.
F101.3 Reserved.
F101.4 Reserved.
F101.5 Reserved.
F101.6 Reserved.
Section BC F102. Protection
F102.1 Exterior walls and underground walls.
For walls or portions thereof within 2 feet (610 mm) of the outside ground level, and for walls below the outside ground level, all openings, including but not limited to annular spaces around pipes, electric cables, and conduits, shall be protected by closing such openings with cement mortar, concrete masonry, metal plates or screening designed to prevent the passage of rodents. Openings for doors, windows and vents shall be as provided for in Sections F102.3, F102.4 and F102.5, respectively.
F102.2 Floors on grade.
Unless otherwise specified in this code, floors on grade, including but not limited to cellar floors and crawl space floors, shall be constructed of a minimum 2 inch (51 mm) thick continuous concrete slab. Gaps shall not be permitted between the slab and the abutting foundation walls or columns, except where expansion joints, thermal breaks, and control joints are located. All openings including but not limited to annular spaces around pipes, electric cables, and conduits in the slab shall be protected by closing such openings with cement mortar, concrete masonry, metal plates or screening designed to prevent the passage of rodents.
F102.3 Exterior doors.
Where an exterior door is nonmetal or nonmetal-clad, such door shall be covered with a kick plate of a minimum thickness of 0.033 inch (0.84 mm), extending at least 8 inches (203 mm) from the bottom of the door, and covering the entire width of the door. When closed, the maximum clearance between any door, door jambs and sills shall not be greater than 3/8 inch (9.5 mm).
F102.4 Windows and other openings.
Windows and other openings shall comply with Sections F102.4.1 and F102.4.2.
F102.4.1 Openings within two feet of ground level.
Operable windows and other openings providing required or voluntary natural ventilation located with any portion within 2 feet (610 mm) above outside ground level immediately below such opening shall be covered for their entire height and width of the operable portion with hardware cloth of at least 0.035 inch (0.89 mm) wire or heavier. The openings in the hardware cloth shall not exceed 1/4 inch (6.4 mm).
F102.4.2 Rodent-accessible openings.
Operable windows and other openings providing required or voluntary natural ventilation in the exterior located within 2 feet (610 mm) of exposed pipes, wires, conduits and other appurtenances, shall be covered with wire cloth of at least 0.035 inch (0.89 mm) wire. The openings in the hardware cloth shall not exceed 1/4 inch (6.4 mm).
Exception: In lieu of wire cloth covering, said pipes, wires, conduits and other appurtenances shall be blocked from rodent usage in accordance with one of the following:
1. Installation of solid sheet metal collars 0.024 inch (0.61 mm) thick or heavier. Such collars shall be fastened around the pipes, wires, conduits or other appurtenances, projecting a minimum distance of 12 inches (305 mm) beyond and on either side of the pipes, wires, conduits or appurtenances.
2. Installation of solid sheet metal guards fastened securely to the exterior wall, projecting 12 inches (305 mm) perpendicularly from the exterior wall for the length of the opening plus 2 feet (610 mm) beyond each end of the opening.
F102.5 Exterior wall ventilation openings.
Exterior wall ventilator openings located with any portion within 2 feet (610 mm) of outside ground level shall be covered for their height and width with perforated sheet metal plates no less than 0.070 inch (1.8 mm) thick, expanded sheet metal plates not less than 0.047 inch (1.2 mm) thick, cast-iron grills or grating, extruded aluminum load-bearing vents or with hardware cloth of 0.035 inch (0.89 mm) wire or heavier. The openings therein shall not exceed 1/4 inch (6.4 mm).
Section BC G101. Purpose and Objectives
G101.1 Purpose.
The purpose of this appendix is to promote the public health, safety and general welfare and to minimize public and private losses due to flood conditions in specific flood hazard areas through the establishment of comprehensive regulations for management of flood hazard areas designed to:
1. Prevent unnecessary disruption of commerce, access and public service during times of flooding;
2. Manage the alteration of natural floodplains, stream channels and shorelines;
3. Manage filling, grading, dredging and other development that may increase flood damage or erosion potential;
4. Prevent or regulate the construction of flood barriers that will divert floodwaters or that can increase flood hazards;
5. Contribute to improved construction techniques in the floodplains; and
6. Comply with and exceed the minimum standards of the National Flood Insurance Program as administered by the Federal Emergency Management Agency (FEMA).
G101.2 Objectives.
The objectives of this appendix are to:
1. Protect human life;
2. Minimize the expenditure of public money for flood control projects;
3. Minimize the need for rescue and relief efforts associated with flooding;
4. Minimize prolonged business interruption;
5. Minimize damage to structures located in flood hazard areas;
6. Minimize damage to public facilities and utilities such as water, electricity, telephone and sewer lines, and streets and bridges located in flood hazard areas;
7. Help maintain a stable tax base by providing for the sound use and development of flood prone areas; and
8. Ensure that potential owners and occupants are notified that property is within flood hazard areas.
G101.3 Referenced standards.
Where this code makes reference to the nationally recognized standard ASCE 24, such standard shall be as modified for New York City in accordance with Section G501 of this appendix.
G101.4 Reserved.
Section BC G102. Applicability
G102.1 General.
This appendix, in conjunction with the New York City Construction Codes, provides minimum requirements for development located, in whole or in part, in special flood hazard areas and shaded X-Zones within the jurisdiction of New York City, including:
1. Subdivisions. This appendix shall apply to the subdivision of land;
2. Utilities. This appendix shall apply to the installation of utilities;
3. Group U buildings and structures. This appendix shall apply to placement and replacement of Group U buildings as defined in Section 312;
4. Site improvements. This appendix shall apply to site improvements, including but not limited to, temporary or permanent storage of materials, mining, dredging, filling, grading, paving, excavations, operations and other land disturbing activities;
5. Prefabricated buildings and manufactured homes. This appendix shall apply to placement and replacement of prefabricated buildings and manufactured homes;
6. Post-FIRM construction. This appendix shall apply to post-FIRM construction.;
7. Alterations to Post-FIRM construction. This appendix shall apply to repair, alteration, reconstruction, rehabilitation or additions to post-FIRM construction;
8. Substantial improvement of Pre-FIRM construction. This appendix shall apply to substantial improvement of pre-FIRM buildings and structures, including restoration after damage, as if hereafter erected;
9. Horizontal enlargements of pre-FIRM construction. This appendix shall apply to horizontal enlargements of pre-FIRM buildings and structures to the extent of such horizontal enlargement, including but not limited to additions (whether above or below grade), decks, carports, or similar appendages. The existing portions of the structure shall not be required to comply, unless otherwise required because the alteration is deemed a substantial improvement; and
10. Other alterations to pre-FIRM construction. This appendix shall apply to repair, alteration, reconstruction, rehabilitation, or additions to pre-FIRM buildings and structures. No increase in the degree of noncompliance with this appendix shall be permitted. The requirements of this Item 10 shall be deemed satisfied if the work would not increase the degree of noncompliance with this appendix.
10.1. Work that increases the degree of noncompliance. Work to pre-FIRM construction deemed as an increase in the degree of noncompliance includes, but is not limited to:
10.1.1. The conversion of any space below the design flood elevation from nonhabitable space into habitable space;
10.1.2. The creation of a direct communication between a dwelling unit and a space below the design flood elevation;
10.1.3. Where a dwelling unit already has space below the design flood elevation or has space with which the dwelling unit directly communicates that is below the design flood elevation, an increase in such space;
10.1.4. The conversion of any space below the design flood elevation in a non-residential building (for flood zone purposes) to accessory (as such term is defined in NYC ZR) to a group R-1, R-2, or R-3 occupancy, when such space was not previously accessory to such occupancy;
10.1.5. The installation of new components, materials, finishes, plumbing fixtures and equipment below the design flood elevation that are not permitted by this appendix to be located below the design flood elevation, where such similar items did not previously exist, except for new components, materials, finishes, and equipment as permitted by Item 10.2.2;
10.1.6. The lowering of the elevation of a floor of a basement (for floodzone purposes), or a portion thereof located below the design flood elevation, except as permitted by Item 10.2.4;
10.1.7. An alteration consisting of a change in use, occupancy or how such space is used in a building, or portion thereof, that results in a more restrictive flood design class per ASCE 24; and
10.1.8. Any condition not addressed in Items 10.1.1 through 10.1.7 as determined by the commissioner.
10.2. Work that does not increase the degree of noncompliance. The following work to pre-FIRM construction, other than substantial improvements, shall not be deemed as an increase in the degree of noncompliance:
10.2.1. Plumbing fixtures:
10.2.1.1. The in-kind replacement of plumbing fixtures below the design flood elevation; and
10.2.1.2. The installation of new plumbing fixtures in a space within the structure where similar plumbing fixtures already exist, provided that the number of plumbing fixtures is not increased and provided any required backflow prevention and/or sewage ejection is provided in accordance with this appendix.
10.2.2. Components, materials, finishes, equipment, fire protection systems and equipment, and appliances, other than plumbing fixtures:
10.2.2.1. The in-kind replacement of components, materials, finishes, equipment, fire protection systems and equipment, and appliances;
10.2.2.2. The installation of new components, materials, finishes, equipment, fire protection systems and equipment, and appliances, in a space within the structure where similar pre-FIRM items already exist; and
10.2.2.3. Within existing nonresidential portions of a nonresidential (for flood zone purposes) building, the installation of new components, materials, finishes, equipment, fire protection systems and equipment, and appliances which serve only the space(s) being altered below the design flood elevation, provided such items, as well as any associated electrical wiring, are designed and/or isolated so as not to affect the operation of building components, systems and wiring of other parts of the building if submerged. This item shall not include increases to the number of plumbing fixtures or the installation of building systems which support other areas of the building.
10.2.3. Change in use, occupancy or how such space is used. Alteration consisting of a change in use, occupancy or how such space is used in a nonresidential building (for flood zone purposes), or portion thereof, that does not result in a more restrictive flood design class per ASCE 24, is not a conversion from nonhabitable space into habitable space, and is not otherwise required by Item 10.1.4 to comply with this appendix. Such alteration shall also comply with the provisions of Item 10.2.2; and
10.2.4. Pits. The lowering of the elevation of a floor or a portion thereof located below the design flood elevation for pits to accommodate sump pumps, house traps, valve access, cleanouts, ejector pumps and elevators.
11. Retroactive requirements. This appendix shall apply to retroactive requirements as provided for in Section G312.
G102.2 Establishment of areas of special flood hazard.
The following flood hazard map and supporting data are adopted as referenced standards and declared to be a part of this appendix:
1. FEMA FIS 360497.
2. FEMA FIRMs 360497.
G102.2.1 Preliminary flood insurance study and rate maps.
Until such time that the department by rule adopts revised FEMA FIS 360497 and FEMA FIRMs 360497 with a final effective date later than May 1, 2014, the following flood hazard maps and supporting data are also adopted as a referenced standard and declared a part of this appendix.
1. FEMA PFIS 360497.
2. FEMA PFIRMs 360497.
G102.2.2 Effect of preliminary flood insurance study and rate maps.
Notwithstanding any other provision in this appendix to the contrary:
1. All references in this appendix to elevations in FEMA FIS 360497 and FEMA FIRMs 360497 shall be deemed to refer to the greater of (i) the elevations identified in the FEMA FIS 360497/FEMA FIRMs 360497 or (ii) the elevations identified in the FEMA PFIS 360497/FEMA PFIRMs 360497. In comparing elevations, the elevations identified in FEMA FIS 360497 and FEMA FIRMs 360497 that are expressed in relation to the National Geodetic Vertical Datum (NGVD) shall be converted to the North American Vertical Datum (NAVD).
2. All references in this appendix to flood hazard areas as delineated on FEMA FIRMs 360497 shall be deemed to refer to the flood hazard areas as delineated on FEMA PFIRMs 360497 except that, where a structure is located in a flood hazard area as delineated on FEMA PFIRMs 360497 and in a more restrictive flood hazard area as delineated on FEMA FIRMs 360497, such structure shall be deemed to be located in the more restrictive flood hazard area as delineated on FEMA FIRMs 360497.
G102.3 Letters of map change.
Map changes to FEMA FIRMs 360497 shall be administered in compliance with Sections G102.3.1 through G102.3.3.
G102.3.1 Letters of map amendment (LOMA).
Where FEMA FIRMs 360497 indicates that a structure or tax lot is within a delineated special flood hazard area, but the pre-FIRM ground elevations adjacent to the structure or throughout the tax lot are at or above the base flood elevation, the commissioner shall deem such structure or tax lot as being within the special flood hazard area and shall not approve plans except in compliance with this appendix, unless a letter of map amendment (LOMA) is issued by FEMA removing such structure or tax lot from the special flood hazard area.
G102.3.1.1 Letters of map amendment (LOMAs) during pendency of PFIRMs.
Until such time that the department by rule adopts revised FEMA FIS 360497 and FEMA FIRMs 360497 with a final effective date later than April 18, 2018, the commissioner shall not deem issuance of a LOMA by FEMA as removing such structure or tax lot from the special flood hazard area unless the elevations specified in the LOMA equal or exceed the applicable corresponding elevations on the FEMA PFIS 360497/FEMA PFIRMs 360497.
G102.3.2 Letter of map revision based on fill (LOMR-F).
Where FEMA FIRMs 360497 indicates that a structure or tax lot is within a delineated special flood hazard area, but post-FIRM compacted fill is proposed to be added adjacent to the structure or throughout the tax lot to an elevation at or above the base flood elevation, the commissioner shall deem such structure or tax lot as being within the special flood hazard area and shall not approve plans except in compliance with this appendix, unless a conditional or final letter of map revision based on fill (LOMR-F) is issued by FEMA removing such structure or tax lot from the special flood hazard area. Buildings constructed with basements below the Base Flood Elevation on filled land shall maintain a minimum setback distance of 20 feet (6096 mm), at or above the Base Flood Elevation, from the edge of the special flood hazard area to the nearest wall of the basement, regardless of the design approach used. The commissioner shall promulgate rules establishing procedures for processing letters of map revision based on fill (LOMR-F).
G102.3.2.1 Letters of map revision based on fill (LOMR-Fs) during pendency of PFIRMs.
Until such time that the department by rule adopts revised FEMA FIS 360497 and FEMA FIRMs 360497 with a final effective date later than April 18, 2018, the commissioner shall not deem issuance of a LOMR-F as removing such structure or tax lot from the special flood hazard area unless the elevations specified in the LOMR-F equal or exceed the applicable corresponding elevations on the FEMA PFIS 360497/FEMA PFIRMs 360497.
G102.3.3 Certificates of occupancy.
Certificates of occupancy shall indicate that the structure or tax lot is subject to a letter of map amendment (LOMA) or letter of map revision based on fill (LOMR-F) as per Section G106.5.
Section BC G103. Administration
G103.1 Permit applications.
The commissioner is hereby designated as the floodplain administrator for the City of New York and shall review permit applications to determine that:
1. Proposed development sites will be reasonably safe from flooding;
2. All site development activities, including grading, filling, utility installation and drainage modification, and all new construction and substantial improvements (including the placement of prefabricated buildings and manufactured homes) are designed and constructed with methods, practices and materials that minimize flood damage and that are in accordance with this code and ASCE 24; and
3. All other required state and federal permits have been obtained.
G103.2 Reserved.
G103.3 Determination of flood elevations.
Flood elevations shall be determined in accordance with Sections G103.3.1 through G103.3.2.
G103.3.1 Determination of base flood elevations.
Where the proposed development is within a special flood hazard area but the base flood elevations are not specified in the FEMA FIRMs 360497, the commissioner shall require the applicant to request base flood elevation data from the New York State Department of Environmental Conservation (DEC); and
1. Submit to the commissioner either:
1.1. A letter from DEC making such a determination of base flood elevation; or
1.2. A letter from the DEC indicating that the data are not available. When such a letter from DEC indicates that the data are not available, the base flood elevation shall be equal to 3 feet (914 mm) above the highest adjacent pre-FIRM grade.
Exception: Large lots. Where the base flood elevation is not specified, the applicant shall submit a detailed engineering study establishing the base flood elevation, performed by an engineer in accordance with accepted hydrologic and hydraulic engineering techniques, in sufficient detail to allow review by the commissioner for any of the following conditions:
1. For a development which is located on a tax lot greater than 5 acres (2.02 hectares), or is located on property that was part of a tax lot that was greater than 5 acres (2.02 hectares) at the time of the adoption of the FIRM (October 1, 1984), or at any subsequent applicable map change thereto; or
2. For subdivisions resulting in 50 or more tax lots, including all tax lots previously subdivided from the same tax lot since the adoption of the FIRM (October 1, 1984), or since any subsequent applicable map changes thereto.
G103.3.2 Determination of 500-year flood elevations.
Where 500-year flood elevations are not specified in the FEMA FIRMs 360497 or FEMA FIS 360497, such elevations shall be determined by a registered design professional using modeling based on generally accepted engineering methods or a review of available data from city, state and federal agencies.
G103.4 Reserved.
G103.5 Floodway encroachment.
Prior to issuing a permit for any floodway encroachment, including fill, new construction, substantial improvements and other development or land-disturbing activity, the commissioner shall require submission of a certification, prepared by a registered design professional, along with supporting technical data, demonstrating that such development will not cause any increase of the level of the base flood.
G103.5.1 Floodway revisions.
A floodway encroachment that increases the level of the base flood is authorized if the applicant has applied for a conditional Flood Insurance Rate Map (FIRM) revision and has received the approval of the Federal Emergency Management Agency (FEMA).
G103.6 Watercourse alteration.
Prior to issuing a permit for any alteration or relocation of any watercourse within a special flood hazard area, the commissioner shall require the applicant to:
1. Notify any affected adjacent municipalities or government jurisdictions;
2. Notify the DEC;
3. Submit evidence of such notifications to the commissioner and the Regional Director, Region II, the Federal Emergency Management Agency (FEMA);
4. Submit to the commissioner evidence of all such notifications;
5. Submit an engineering analysis demonstrating that the flood-carrying capacity of the altered or relocated portion of the watercourse will not be decreased; and
6. Submit evidence that such watercourses will be maintained in a manner which preserves the channel's flood-carrying capacity.
G103.7 Alterations in coastal areas.
Prior to issuing a permit for any alteration of sand dunes in coastal high-hazard areas and coastal A- zones, the commissioner shall require submission of an engineering analysis, prepared by a registered design professional, demonstrating that the proposed alteration will not increase the potential for flood damage.
G103.8 Records.
The commissioner shall maintain records of the following:
1. Applications and supporting documents for development in flood hazard areas;
2. Permits issued in flood hazard areas;
3. Inspection reports;
4. Certifications required in this appendix; and
5. Certificate of occupancy where applicable.
G103.9 Violations.
See Chapter 2 of Title 28 of the Administrative Code.
Section BC G104. Permits
G104.1 Required.
Any person, owner or owner's authorized agent who intends to conduct any development, as applicable pursuant to Section G102.1, within a flood hazard area, shall first make application to the commissioner and shall obtain the required permit in accordance with Section 28-105.1 of the Administrative Code, notwithstanding any exemption pursuant to Section 28-105.4 of the Administrative Code.
G104.2 Application for permit.
The applicant shall file an application in writing on a form furnished by the commissioner. The commissioner shall not approve such application unless the applicant submits all plans, details, data and documents demonstrating that the development complies with Sections G104.2.1 through G104.2.3 and all other provisions of this appendix.
G104.2.1 Flood zone compliance plans.
The permit application shall include flood zone compliance plans. Such plans shall include plans and drawings, shall be sealed by a registered design professional and shall include a site plan and the following information and any other data as may be required by the department:
1. Flood design class assigned according to ASCE 24;
2. A delineation of the flood hazard areas, including identification of the base flood elevation(s), design flood elevations and stillwater flood depth;
3. If applicable, the location of the regulatory floodway;
4. For all proposed structures, spot ground elevations at building corners and in 20-foot (6096 mm) or smaller intervals along the foundation footprint, or 1-foot (305 mm) contour elevations throughout the building site;
5. Proposed locations of water supply, sanitary sewer, and utilities;
6. Drainage patterns and facilities;
7. Foundation design details, including but not limited to:
7.1. Proposed elevation of the lowest floor including basement (for flood zone purposes) of all structures;
7.2. For crawl spaces and enclosed parking, storage and building access that are wet floodproofed below the design flood elevation, location and total net area of foundation openings in accordance with ASCE 24;
7.3. For dry floodproofed spaces in buildings or structures that are nonresidential (for flood zone purposes), the proposed elevation to which the enclosure will be dry floodproofed in accordance with ASCE 24;
7.4. Any proposed fill and excavation details ; and
7.5. In coastal high-hazard areas and coastal A-zones, the proposed elevation of the bottom of the lowest horizontal structural member of the lowest floor; and
8. For structures in coastal high-hazard areas or coastal A-zones, and for dry-floodproofed structures: flood loading and parameters including average velocity of water (V), debris impact load (F i ), scour depths, and wave loads (F t or F D ).
Exception: Applications for subdivisions shall comply with Section G302.
G104.2.2 Watercourse alteration.
The permit application shall include documentation required by Section G103.6 and, if applicable, a description of the extent to which any watercourse will be altered or relocated as a result of proposed development.
G104.2.3 Certifications.
The permit application shall include the applicable certifications in accordance with Sections G104.2.3.1 through G104.2.3.3.
G104.2.3.1 A-Zones.
For construction in A-Zones, the permit application shall include the following certifications, as applicable:
1. Wet floodproofing certification. For applications involving wet floodproofed enclosures below the design flood elevation, flood zone compliance plans shall include a certification by the applicant, as applicable to the scope of work proposed, that "in accordance with ASCE 24, the use of the enclosure is limited to the parking of vehicles, building access, or storage, and that the design incorporates openings to allow for the automatic entry and exit of floodwaters for equalization of hydrostatic flood forces and flood damage-resistant materials and techniques that minimize damage to a structure by floodwater."
2. Dry floodproofing certification for nonresidential buildings. For applications involving dry floodproofed buildings and structures that are nonresidential (for flood zone purposes), flood zone compliance plans shall include a certification by the applicant that "the structure is designed to be dry floodproofed with walls that are substantially impermeable to the passage of water and that all walls, floors, and flood shields are designed to resist hydrostatic, hydrodynamic, and other flood-related loads, including the effects of buoyancy resulting from flooding to the elevation listed in Table 6-1 in accordance with ASCE 24."
3. Utility certifications. For all applications involving utility or mechanical work, including applications where such work is to be filed in a separate, related application, flood zone compliance plans shall include a certification by the applicant that "all heating, ventilation, air conditioning, plumbing, electrical and other services facilities and equipment within the structure or site will be located or constructed so as to prevent water from entering or accumulating within the components during conditions of flooding in accordance with ASCE 24."
G104.2.3.2 Coastal high-hazard areas and coastal A-Zones.
For construction in coastal high-hazard areas and coastal A-Zones, the permit application shall include the following certifications, as applicable:
1. Structural design certification. Flood zone compliance plans shall include a certification by the applicant that the "entire structure is designed in accordance with ASCE 24, including that the pile or column foundation and building or structure to be attached thereto is designed to be anchored to resist flotation, collapse and lateral movement due to the effects of wind and flood loads acting simultaneously on all building components, and other load requirements of Chapter 16 of the New York City Building Code."
2. Breakaway wall certification. Where breakaway walls are provided, flood zone compliance plans shall include a certification by applicant that "the breakaway walls meet the load requirements of Section 5.3.3 of ASCE 7, are designed in accordance with ASCE 24, and are of an open lattice-type construction only."
3. Utility certifications. For all applications involving utility or mechanical work, including applications where such work is to be filed in a separate, related application, flood zone compliance plans shall include a certification by the applicant that "all heating, ventilation, air conditioning, plumbing, electrical and other services, facilities and equipment within the structure or site will be located or constructed so as to prevent water from entering or accumulating within the components during conditions of flooding, in accordance with ASCE 24."
G104.2.3.3 Floodway encroachment certification.
For any floodway encroachment, including fill, new construction, substantial improvements and other development or land-disturbing activity, the applicant shall submit a certification, along with supporting technical data, demonstrating that such development will not cause any increase of the level of the base flood in accordance with the requirements of Section G103.5.
G104.3 Validity of permit.
The issuance of a permit under this appendix shall not be construed to be a permit for, or approval of, any violation of this appendix or any other provision of this code. The issuance of a permit based on submitted documents and information shall not prevent the commissioner from requiring the correction of errors. The commissioner is authorized to prevent occupancy or use of a structure or site that is in violation of this appendix or other provisions of this code.
G104.4 Expiration.
A permit shall become invalid if the proposed development is not commenced within 180 days after its issuance, or if the work authorized is suspended or abandoned for a period of 180 days after the work commences.
G104.5 Suspension or revocation.
The commissioner is authorized to suspend or revoke a permit issued under this appendix wherever the permit is issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of this code, in accordance with Section 28-105 of the Administrative Code.
G104.6 Reinstatement.
Permit reinstatements for a permit that has expired pursuant to Section G104.4 shall be requested in writing. The commissioner is authorized to grant such reinstatement, provided that the work shall comply with all of the requirements of this appendix, including any revised FEMA FIRMs 360497 in effect at the time the application for reinstatement is made, and provided further that the applicant shall pay all reinstatement fees as required in Article 112 of Title 28 of the Administrative Code.*
* Editor's note: As set forth in L.L. 2021/126; correct cite is Article 112 of Chapter 1 of Title 28 of the Administrative Code.
Section BC G105. Variances
G105.1 General.
The Board of Standards and Appeals shall hear and decide requests for variances from the requirements of this appendix. The Board of Standards and Appeals shall base its determination on technical justifications, and has the right to attach such conditions to variances as it deems necessary to further the purposes and objectives of this appendix.
Exception: In specific cases, provided that noncompliance with the requirements of the 44 CFR section 60.3 is not created, the commissioner shall be authorized to vary the standards prescribed in this appendix under and pursuant to the provisions of Section 28-103.3 of the Administrative Code and Section 645(b)(2) of the New York City Charter, including but not limited to:
1. Increases to the number of plumbing fixtures on an existing non-dry floodproofed story located below DFE including to accommodate compliance with the New York City Plumbing Code or Chapter 11 of this code for accessibility for persons with disabilities, or both; and
2. Modifications to the egress provisions of ASCE 24, Section 6.2.2.
G105.2 Records.
The Board of Standards and Appeals shall:
1. Maintain a record of all variance actions, including justification for their issuance; and
2. Report such variances issued in its biennial report submitted to the Federal Emergency Management Agency (FEMA).
G105.3 Historic structures.
A variance is authorized to be issued by the Board of Standards and Appeals for the repair or rehabilitation of a historic structure upon a determination that the proposed repair or rehabilitation will not preclude the structure's continued designation as a historic structure, and the variance is the minimum necessary to preserve the historic character and design of the structure.
G105.4 Functionally dependent facilities.
The Board of Standards and Appeals is authorized to issue a variance for the construction or substantial improvement of a functionally dependent facility provided the criteria in Sections G105.3, G105.5 and G105.7 are met and the variance is the minimum necessary to allow the construction or substantial improvement, and that all due consideration has been given to methods and materials that minimize flood damages during the base flood and create no additional threats to public safety.
G105.5 Floodway restrictions.
The Board of Standards and Appeals shall not issue a variance for any proposed development in a floodway if any increase in flood levels would result during the base flood discharge.
G105.6 Conditions.
In reviewing applications for variances, the Board of Standards and Appeals shall consider all technical evaluations, all relevant factors, all other portions of this appendix and the following:
1. The danger that materials and debris may be swept onto other lands resulting in further injury or damage.
2. The danger to life and property due to flooding or erosion damage.
3. The susceptibility of the proposed development, including contents, to flood damage and the effect of such damage on current and future owners.
4. The importance of the services provided by the proposed development to the community.
5. The availability of alternate locations for the proposed development that are not subject to flooding or erosion.
6. The compatibility of the proposed development with existing and anticipated development.
7. The relationship of the proposed development to the comprehensive plan and floodplain management program for that area.
8. The safety of access to the property in times of flood for ordinary and emergency vehicles.
9. The expected heights, velocity, duration, rate of rise and debris and sediment transport of the floodwaters and the effects of wave action, if applicable, expected at the site.
10. The costs of providing governmental services during and after flood conditions including maintenance and repair of public utilities and facilities such as sewer, gas, electrical and water systems, streets and bridges.
G105.7 Conditions for issuance.
Except for historic structures as provided for in Section G105.3, the Board of Standards and Appeals is authorized to issue a variance where all of the following criteria are met:
1. A technical showing of good and sufficient cause that the characteristics of the size, configuration or topography of the site renders the standards inappropriate;
2. A determination that failure to grant the variance would result in exceptional hardship to the applicant for the variance;
3. A determination that the granting of a variance will not result in increased flood heights, additional threats to public safety, extraordinary public expense, nor create nuisances, cause fraud on or victimization of the public or conflict with existing local laws or ordinances;
4. A determination that the variance is the minimum necessary, considering the flood hazard, to afford relief;
5. Notification to the applicant in writing over the signature of the Executive Director of the Board of Standards and Appeals that the issuance of a variance to construct a structure below the base flood level will result in increased premium rates for flood insurance up to amounts as high as $25 for $100 of insurance coverage, and that such construction below the base flood level increases risks to life and property; and
6. A determination that the new construction, substantial improvement, or other proposed development is located on a tax lot that, on November 16, 1983, was no more than 1/2 acre (0.2 hectare) in size. However, where the tax lot has been determined to be larger than 1/2 acre (0.2 hectare), the technical justification required for issuing the variance increases with the lot size.
Section BC G106. Certificates of Occupancy
G106.1 Applicability.
This section shall apply to post-FIRM construction and substantial improvements where the work results in the issuance of a new or amended certificate of occupancy.
G106.2 Enclosed areas subject to flooding in A-Zones.
The certificate of occupancy shall describe all enclosed areas below the design flood elevation that are subject to flooding and that meet the requirements of this appendix for wet floodproofing as "wet floodproofed, subject to flooding". The certificate of occupancy shall indicate the use of wet floodproofed spaces as either parking, storage, building access or crawl spaces. The certificate of occupancy shall be issued with the following restriction: "Levels subject to flooding shall not be used for any other use except as stated on this certificate."
G106.3 Enclosed areas subject to flooding in coastal high-hazard areas and coastal A-Zones.
The certificate of occupancy shall describe all enclosed areas below the design flood elevation that are not dry floodproofed as "subject to flooding". The certificate of occupancy shall indicate the use of spaces enclosed by open lattice breakaway walls below the design flood elevation as either unconditioned parking, unconditioned storage, or unconditioned building access. The certificate of occupancy shall be issued with the following restriction: "Levels subject to flooding shall not be used for any other use except as stated on this certificate."
G106.4 Dry floodproofed spaces.
The certificate of occupancy shall describe any dry floodproofed spaces as "dry floodproofed." Where flood shields or other flood control devices are installed, the certificate of occupancy shall also provide notations describing these features. For evacuated buildings or evacuated portions of buildings utilizing the temporary stair or ramp provisions of Section G308.10.1, the certificate of occupancy shall note: "In portions of this building planned to be evacuated during flood conditions, occupancy shall be prohibited except for maintenance or emergency personnel."
(Am. L.L. 2023/077, 6/11/2023, eff. 6/11/2023)
Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2023/077.
G106.4.1 Restrictive declaration.
Where dry floodproofed buildings contain dwelling units, patient care areas (for flood zone purposes) or spaces intended to be used by persons for sleeping purposes, the certificate of occupancy shall also provide notations as required by Section G304.1.2, Item 2.2.
G106.5 Letters of map change.
Where applicable, the certificate of occupancy shall indicate that "the structure is exempted from the special flood hazard area pursuant to FEMA Letter of Map Amendment (LOMA) # (_______)," or that "the structure is exempted from the special flood hazard area pursuant to FEMA Letter of Map Revision Based on Fill (LOMR-F) # (_______)," or that "the structure is exempted from the special flood hazard area pursuant to FEMA Letter of Map Revision (LOMR) # (_______)."