§ 175.11. Communications with Workers

Open this section

(a) Purpose and scope. This section establishes requirements for notices, instructions and reports by registrants to individuals engaged in activities under a registration. This section also sets forth options available to such individuals in connection with Department inspections of registrants conducted to ascertain compliance with the provisions of this Article and all applicable regulations and conditions stated on the registration regarding radiological working conditions. The regulations in this section apply to all persons who receive, possess, produce, use, own or transfer sources of radiation registered with the Department or are otherwise subject to this Article.

(b) Posting of notices to workers.

(1) Each registrant must post current copies of the following documents:

(i) 24 RCNY Health Code Article 175, or a notice providing an electronic link or internet address to a copy of 24 RCNY Health Code Article 175;

(ii) the registration or certified registration and the conditions or documents incorporated by reference into the certified registration and any amendments thereto;

(iii) the operating procedures applicable to the work under the registration or certified registration;

(iv) any notice of violation involving radiological working conditions, any proposed imposition of civil penalty or order issued pursuant to this Article and any response from the registrant.

(2) If posting of a document specified in this section is not practicable, the registrant may post a notice which describes the document and states where it may be examined.

(3) A current copy of the "Notice to Employees" prescribed by the Department must be posted by each registrant wherever individuals work in or frequent any portion of a restricted area.

(4) Documents, notices, or forms posted pursuant to this Article must appear conspicuously in a sufficient number of places to permit individuals engaged in work under the certified registration or registration to observe them on the way to or from any particular work location to which the document applies, and must be replaced if defaced or altered.

(5) Department documents posted pursuant to this section must be posted within 2 working days after receipt of the documents from the Department; the registrant's response, if any, must be posted within 2 working days after dispatch from the registrant. Such documents must remain posted for a minimum of 5 working days or until action correcting the violation has been completed, whichever is later.

(c) Instructions to workers.

(1) All individuals working in or frequenting any portion of a restricted area must be:

(i) kept informed of the storage, transfer, or use of radiation producing equipment or of radiation in such portions of the restricted area;

(ii) instructed in the operating procedures applicable to work under the registration or certified registration, in the health protection problems associated with exposure to such radiation, in precautions or procedures to minimize exposure, and in the purposes and functions of protective devices employed, and must be required to demonstrate familiarity with such precautions, procedures and devices;

(iii) instructed in, and instructed to observe, to the extent within the worker's control, the applicable provisions of this Article, registrations or certified registrations for the protection of personnel from exposures to radiation occurring in such areas;

(iv) instructed of their responsibility to report promptly to the registrant on any condition which may lead to or cause a violation of this Article or the registration, or unnecessary exposure to radiation;

(v) instructed in the appropriate response to warnings made in the event of any unusual occurrence or malfunction that may involve exposure to radiation; and

(vi) advised as to the radiation exposure reports which workers must be given or may request pursuant to this section.

(2) The extent of these instructions shall be commensurate with potential radiological health protection problems in the restricted area.

(3) Instruction must be given before an individual begins work in a restricted area and at least annually thereafter.

(4) Records documenting individual worker instruction must be maintained for inspection by the Department for 5 years.

(d) Each registrant must inform each worker who is monitored pursuant to 24 RCNY Health Code § 175.17 of the worker's exposure to radiation or radioactive material as shown in records maintained by the registrant pursuant to 24 RCNY Health Code § 175.22. The information must be provided at least annually.

(1) Each registrant must make dose information available to workers as shown in records maintained by the registrant under the provisions of 24 RCNY Health Code § 175.24.

(2) The individual engaged or formerly engaged in activities controlled by the registrant may request his or her annual dose report.

(i) The report must include the dose record for each year the worker was required to be monitored pursuant to this Article. Such report must be furnished to the individual within 30 days from the date of the request, or within 30 days after the dose of the individual has been determined by the registrant, whichever is later.

(ii) At the request of a worker who is terminating employment with the registrant in work involving exposure to radiation during the current year, each registrant must provide at termination to each such worker, or to the worker's designee, a written report regarding the radiation dose received by that worker from operations of the registrant during the current year or fraction thereof.

(e) Presence of representatives of registrants and workers during inspections.

(1) Each registrant must afford the Department at all reasonable times an opportunity to perform an inspection of machines, activities, facilities, premises and records required pursuant to this Article.

(2) During an inspection, Department inspectors may consult privately with workers. The registrant, or that person's representative, may accompany the Department inspectors during other phases of an inspection.

(3) If, at the time of inspection, an individual has been authorized by the workers to represent them during Department inspections, the registrant must notify the inspectors of such authorization and must give the workers' representatives an opportunity to accompany the inspectors during the inspection of physical working conditions.

(4) Each worker's representative must be routinely engaged in work under control of the registrant and must have received instructions as specified in this section.

(5) Different representatives of registrants and workers may accompany the inspectors during different phases of an inspection if there is no resulting interference with the conduct of the inspection. However, only one workers' representative at a time may accompany the inspectors.

(6) With the approval of the registrant and the workers' representative, an individual who is not routinely engaged in work under control of the registrant, for example a consultant to the registrant or to the workers' representative, must be afforded the opportunity to accompany inspectors during the inspection of physical working conditions.

(7) Notwithstanding the other provisions of this subdivision, Department inspectors are authorized to refuse to permit accompaniment by any individual who deliberately interferes with a fair and orderly inspection. With regard to any area containing proprietary information, the workers' representative for that area must be an individual previously authorized by the licensee or registrant to enter that area.

(f) Consultation with workers during inspections.

(1) Department inspectors may consult privately with workers concerning matters of occupational radiation protection and other matters related to applicable provisions of this Article, certified registrations and registrations to the extent the inspectors deem necessary for the conduct of an effective and thorough inspection.

(2) During the course of an inspection any worker may bring privately to the attention of the inspectors, either orally or in writing, any past or present condition which the worker has reason to believe may have contributed to or caused any violations of this Article, certified registration condition or registration, or any unnecessary exposure of any individual to radiation from sources of radiation under the registrant's control.

(g) Requests by workers for inspections.

(1) Any worker or representative of workers who believes that a violation of this Article, registration, certified registration or license conditions exists or has occurred in work under a license or certificate of registration with regard to radiological working conditions in which the worker is engaged, may request an inspection by giving notice of the alleged violation to the Department. Any such notice must be in writing, must set forth the specific grounds for the notice, and must be signed by the worker or representative of the workers. A copy must be provided to the licensee or registrant by the Department no later than at the time of inspection. The worker giving such notice may request that his or her name and the name of individuals referred to therein not appear in such copy or any record published, released, or made available by the Department, except for good cause shown.

(2) If, upon receipt of such notice, the Department determines that the complaint meets the requirements set forth in paragraph (1) of this subdivision and that there are reasonable grounds to believe that the alleged violation exists or has occurred, an inspection shall be made as soon as practicable, to determine if such alleged violation exists or has occurred. Inspections performed pursuant to paragraph (1) of this subdivision need not be limited to matters referred to in the complaint.

(3) No licensee, registrant, or contractor or subcontractor of a registrant shall discharge or in any manner discriminate against any worker because such worker has filed any complaint or instituted or caused to be instituted any proceeding under this Article or has testified or is about to testify in any such proceeding or because of the exercise by such worker on behalf of such worker or others of any option afforded by this Article.

(h) Inspections not warranted; informal review.

(1) If the Department determines, with respect to a complaint under paragraph (1) of subdivision (g) of this section that an inspection is not warranted because there are no reasonable grounds to believe that a violation exists or has occurred, the Department shall notify the complainant in writing of such determination. The complainant may obtain review of such determination by submitting a written statement of position with the Deputy Commissioner for Environmental Health Services, who will provide the licensee or registrant with a copy of such statement by certified mail, excluding, at the request of the complainant, the name of the complainant. The registrant may submit an opposing written statement of position with the Deputy Commissioner of Environmental Health Services who will provide the complainant with a copy of such statement by certified mail.

(2) Upon the request of the complainant, the Deputy Commissioner for Environmental Health Services may hold an informal conference in which the complainant and the licensee or registrant may orally present their views. An informal conference may also be held at the request of the licensee or registrant, but disclosure of the identity of the complainant will be made only following receipt of written authorization from the complainant. After considering all written or oral views presented, the Deputy Commissioner for Environmental Health Services shall affirm, modify, or reverse the determination of the Department's Office of Radiological Health and furnish the complainant and the licensee or registrant a written notification of the decision and the reason therefor. (3) If the Department determines that an inspection is not warranted because the requirements of paragraph (1) of subdivision (g) of this section have not been met, the complainant shall be notified in writing of such determination. Such determination shall be without prejudice to the filing of a new complaint meeting the requirements of such paragraph.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.12. Quality Assurance (QA) Program Requirements for Diagnostic Facilities

Open this section

(a) Purpose and scope. This section establishes quality assurance (as defined in 24 RCNY Health Code § 175.08) requirements for the use of machine-produced radiation or the radiation therefrom for diagnostic uses in the healing arts. The requirements in this section are intended to provide for the protection of the public health and safety and are in addition to, and not in substitution for, other applicable requirements in this Article.

(b) Diagnostic facilities.

(1) Except dental, podiatric or veterinary facilities, each radiation installation performing diagnostic x-rays on humans must implement a quality assurance program that includes at a minimum:

(i) the adoption of a facility- and equipment-specific QA manual containing written policies and procedures for radiation protection and describing the facility's quality assurance program. Policies and procedures must be consistent with the types of equipment and services provided including, but not limited to, identification of patients, use of gonadal or scoliosis shielding, personnel monitoring, protection of pregnant workers and patients and holding of patients. The quality assurance manual must describe the various processing, generator and systems QA tests appropriate for the types of equipment and services provided in sufficient detail to ensure that they will be performed properly;

(ii) the performance of QA tests and correction of deficiencies as specified in the QA manual;

(iii) the maintenance of equipment records for each diagnostic imaging system, containing test results, records of equipment repairs and other pertinent information;

(iv) requirements for performing appropriate testing as determined by the QMP after replacement or repair of equipment components that could adversely affect the resolution of the x-ray system and/or could cause an increase in patient dose;

(v) the provisions of a formalized in-service training program for employees including, but not limited to, quality assurance and radiation safety procedures;

(vi) the direct or indirect determination of radiation output at the point of skin entry for examinations routinely performed at the facility;

(vii) the provision of the information described in subparagraph (vi) of this paragraph to any patient upon request; and

(viii) the performance of and analysis of repeated, rejected or diagnostic events which are designed to identify and correct problems and to optimize quality.

(2) Each registrant must maintain written records documenting QA and audit activities for review by the Department. Such records must be maintained by the registrant at least until after the next scheduled inspection is completed by the Department.

(3) Diagnostic facility registrants required to maintain the facility-specific QA manual must comply with the requirements of this Article, as well as any registration conditions or Department directives or orders. Failure to maintain an up-to-date QA manual, or not adhering to this Article or Department directives or orders, shall be deemed as equivalent to the registrant not conducting a mandated QA program in violation of this section.

(4) For hospital registrants only, a QMP, or the Radiation Safety Officer working with a QMP, must conduct oversight of its quality assurance programs, by:

(i) auditing the QA program on an annual basis for compliance with the hospital's QA manual and the requirements of this Article; and

(ii) submitting the annual audit report to the hospital radiation safety committee. The annual audit report must document the review of the following:

(A) the hospital's personnel monitoring program for compliance with this Article and hospital QA manual requirements; and

(B) the hospital's equipment QA testing, including frequency of testing, and resolution of equipment failures as to timely repair and testing, if any; and

(C) the calibration of radiation instruments used for equipment testing, if owned by the hospital; and

(D) the status of hospital employee training, both annual training requirements and Article requirements, for training hospital staff for specific equipment types; and

(E) review of all medical events that occurred in the hospital in relation to x-ray exams and an evaluation of the measures to prevent such re-occurrences and their effectiveness.

(iii) The recommendations cited in the annual hospital audit report of subparagraph (ii) of paragraph (4) of this subdivision must be reviewed by the hospital radiation safety committee for a compliance determination. A written record of the hospital radiation safety committee decisions on the annual audit recommendations must be retained for review by the Department during periodic inspections.

(5) Neonatal imaging. Neonatal intensive care units must develop a QA program which includes the following protocols:

(i) establishing a technique chart for neonatal imaging including, at a minimum, specific techniques for chest and abdomen, along with corresponding direct or indirect determination of entrance skin dose; and

(ii) an annual training program for Licensed Radiographic Technologists (LRTs) for conducting neonatal imaging; and

(iii) a protocol for the proper use of neonatal collimation; and

(iv) a protocol of gonadal shielding; and

(v) each facility must conduct an annual report on the compliance with the facility's neonatal QA program and forward such report to the facility radiation safety committee for review

(6) Each registrant that conducts x-ray imaging of children must establish specific techniques at least for 1-year old, 5-year old and 10-year old children, specific to PA chest and abdomen x-ray studies. Additionally, the entrance skin exposure must be directly or indirectly determined for the latter studies and posted in the facility along with the technique chart wherever it is reasonable to expect that children of such an age group can be x-rayed.

(c) X-ray film processing facilities. Registrants using analog image receptors (e.g., radiographic film) must have available suitable equipment for the handling and processing of radiographic film in accordance with the following provisions:

(1) Manually developed film shall be prohibited, except during dental surgical procedures when required.

(2) Automatic processors and other closed processing systems:

(i) automatic processors must be operated and maintained following manufacturer specifications.

(ii) films must be developed in accordance with the time-temperature relationships recommended by the film manufacturer; in the absence of such recommendations, the film must be developed using the following chart:

Developer Temperature Minimum Immersion Time* C° F° Seconds 35.5 96 19 35 95 20 34.5 94 21 34 93 22 33.5 92 23 33 91 24 32 90 25 31.5 89 26 31 88 27 30.5 87 28 30 86 29 29.5 85 30 * Immersion time only, no crossover time included.

(3) Processing deviations from the above requirements of this section must be documented by the registrant in such manner that the requirements are shown to be met or exceeded (e.g., extended processing and special rapid chemistry).

(d) Additional requirements for facilities using x-ray film.

(1) Pass boxes, if provided, must be constructed to exclude light from the darkroom when cassettes are placed in or removed from the boxes and must incorporate adequate shielding from stray radiation to prevent exposure of undeveloped film.

(2) Darkrooms typically used by more than one individual must prevent accidental entry while undeveloped films are being handled or processed.

(3) Film must be stored in a cool, dry place and must be protected from exposure to stray radiation. Film in open packages must be stored in a light-tight container.

(4) Film cassettes and intensifying screens must be inspected periodically and must be cleaned and replaced as necessary.

(5) Outdated x-ray film past the manufacturer's expiration date must not be used for diagnostic radiographs of patients.

(6) The film and intensifying screen must be spectrally compatible.

(7) Facilities must maintain a light-tight darkroom, use proper safelighting and safeguards, and evaluate darkroom integrity and daylight loading systems for film fog every 6 months and after a change that may impact film fog.

(e) X-ray film processing facilities other than dental, podiatry or veterinary must:

(1) have a continuous and documented sensitometric QA program, including QA tests for speed, contrast and fog. These tests must be performed according to specifications of the manufacturer, a QMP, or a nationally-recognized organization.

(2) maintain a light-tight darkroom and use proper safelighting and safeguards such that any film type in use exposed in a cassette to x-radiation sufficient to produce an optical density from 1 to 2 when processed shall not increase in optical density by more than 0.1 when exposed in the darkroom for 2 minutes with all safelights on. If used, daylight film handling boxes must preclude fogging of the film.

(3) limit the base plus fog of unexposed film to an optical density less than 0.25 when developed by the routine procedure used by the facility.

(f) Facilities using Computed Radiography (CR) or Direct Digital Radiography (DDR).

(1) Commencing July 1, 2021, when exposure indicators are available, the facility must establish and document an acceptable range for the exposure values for examinations routinely performed at the facility. The indicated exposure values for a representative percentage of images taken must be compared to the established range. Consistent deviations from established ranges must be investigated, corrective actions taken as necessary, and results documented. This exposure range developed above must be posted at or near the x- ray console.

(2) Facilities must establish and follow an image QA program in accord with the recommendations of a QMP, the system manufacturer, or a nationally recognized organization

(3) Facilities other than dental, podiatric and veterinary, must quarterly complete phantom image evaluation using a phantom approved by a QMP or manufacturer. The analysis at a minimum must include: artifacts, spatial resolution, contrast/noise and exposure indicator constancy.

(4) In addition to the requirements of paragraphs (1) through (3) of this subdivision, CR facilities must establish a schedule of CR cassette erasure consistent with the manufacturer's recommendations.

(g) Requirements for permitted radiographic facilities' Primary Diagnostic Monitors (PDM).

(1) The requirements of this subdivision do not apply to dental, podiatric, veterinary, bone densitometer, nuclear medicine imaging and mammography facilities.

(2) The following definitions apply to this subdivision:

"Digital Imaging and Communications in Medicine (DICOM)" means a standard for handling, storing, printing and transmitting information in medical imaging.

"Documenting" means written, electronic or photographic records of testing performance.

"Maximum luminance" means the maximum light emission from the PDM front surface as measured by a calibrated photometer in units of candela/m 2 .

"Medical monitor" means any monitor that has both a built-in photometer and a QA software program allowing for routine QA tests to be performed.

"Monitor" means a display device that shows the results of a patient radiological image.

"Off-site PDM" means when the registrant contracts with a tele-radiology service for patient diagnosis of x-ray procedures. In such circumstances, the tele-radiology service must establish a PDM QA program that conforms to Department requirements.

"Primary Diagnostic Monitor (PDM)" means a monitor used to render a final diagnosis of a patient exam, including interpretations of patient mammograms. Monitors attached to digital units used as PDMs must have a QA program that complies with Department requirements, with the exception of monitors attached to bone densitometer units.

"Preliminary reads ("wet reads")" means a type of monitor that is exempt from PDM requirements. For purposes of this section, monitors used for wet reads, such as a monitor in a hospital emergency room used to make decisions about trauma patients and monitors of fluoroscopy units, are not considered PDMs.

"Registrant" means, for the purposes of the PDM QA requirements of this subdivision, the individual responsible for ensuring that a PDM QA program is implemented on site. This requirement still applies if the registrant contracts with an off-site service, for example, tele-radiology service, for patient final diagnostic evaluations.

"Test pattern" means, for the purposes of PDM QA requirements, a pattern that is either a Society of Motion Picture and Television Engineers (SMPTE) test pattern, or the American Association of Medical Physicists (AAPM) Task Group (TG) #18 test pattern (TG 18 test pattern) or a test pattern from an applicable successor national standard.

(3) QA tests mandated for a PDM QA program. Each facility must make or have made QA tests to monitor equipment performance and maintain records of data collected. The facility must document their PDM quality assurance program in the facility's QA manual along with the results of the QA tests required. The QA tests required to be performed must include, at a minimum:

(i) Visual test pattern evaluation (TG-18QC, SMPTE, or equivalent).

(ii) DICOM calibration of the Grayscale Standard Display Function (GSDF) for each medical monitor on site at the registrant's location.

(iii) Maximum luminance output.

(iv) Minimum luminance output.

(v) Luminance ratio of maximum to minimum.

(vi) Evaluation of viewing conditions.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.13. Occupational Dose Limits

Open this section

(a) The registrant must control the occupational dose to individual adults to the following dose limits:

(1) an annual limit, which is the more limiting of:

(i) the total effective dose equivalent being equal to 0.05 sievert (5 rem); or

(ii) the sum of the deep dose equivalent and the committed dose equivalent to any individual organ or tissue other than the lens of the eye being equal to 0.5 sievert (50 rem).

(2) the annual limits to the lens of the eye, to the skin, and to the extremities which are:

(i) a lens dose equivalent of 0.15 sievert (15 rem); and

(ii) a shallow dose equivalent of 0.5 sievert (50 rem) to the skin or to any extremity.

(b) When the external exposure is determined by measurement with an external personal monitoring device, the deep-dose equivalent must be used in place of the effective dose equivalent, unless the effective dose equivalent is determined by a dosimetry method approved by the Department. The assigned deep dose equivalent shall be for the portion of the body receiving the highest exposure. The assigned shallow dose equivalent must be the dose averaged over the contiguous 10 square centimeters of skin receiving the highest exposure:

(1) when a protective apron is worn while working with medical fluoroscopic equipment and monitoring is conducted as specified in 24 RCNY Health Code § 175.17(b)(4), the effective dose equivalent for external radiation shall be determined as follows: when only one individual monitoring device is used and it is located at the neck (collar) outside the protective apron, the reported deep dose equivalent value divided by 5.6 shall be the effective dose equivalent for external radiation; or

(2) when individual monitoring devices are worn, both under the protective apron at the waist and outside the protective apron at the neck, the effective dose equivalent for external radiation shall be assigned the value of the sum of the deep dose equivalent reported for the individual monitoring device located at the waist under the protective apron multiplied by 1.5 and the deep dose equivalent reported for the individual monitoring device located at the neck outside the protective apron multiplied by 0.04.

(c) The registrant must reduce the dose that an individual may be allowed to receive in the current year by the occupational dose amount received while employed elsewhere during the current year.

(d) The annual occupational dose limits for minors are 10 percent of the annual occupational dose limits for adult workers specified in this section.

(e) Dose to an embryo/fetus.

(1) The registrant must ensure that the dose equivalent to the embryo/fetus during the entire pregnancy, due to occupational exposure of a declared pregnant worker, does not exceed 5 mSv (0.5 rem).

(2) The registrant must review exposure history and adjust working conditions so as to avoid a monthly exposure of more than 0.5 mSv (50 mrem) to a declared pregnant worker.

(3) The dose to an embryo/fetus shall be the sum of:

(i) the deep dose equivalent to the declared pregnant worker; and

(ii) the dose equivalent to the embryo/fetus resulting from radionuclides in the embryo/fetus and radionuclides in the declared pregnant worker.

(4) If, by the time the worker declares pregnancy to the registrant, the dose equivalent to the embryo/fetus is found to have exceeded 5 mSv (0.5 rem), or is within 0.5 mSv (50 mrem) of this dose, the registrant shall be deemed to be in compliance with this subdivision if the additional dose to the embryo/fetus does not exceed 0.5 mSv (50 mrem) during the remainder of the pregnancy.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.14. Dose Limits for Individual Members of the Public

Open this section

(a) Each registrant must conduct operations so that:

(1) the total effective dose equivalent to individual members of the public from the registered operation, does not exceed 1 millisievert (0.1 rem) in a year, exclusive of the dose contribution from background radiation, from any medical administration the individual has received, from exposure to individuals administered radioactive material and released in accordance with the requirements of 10 C.F.R. Part 35, or from voluntary participation in medical research programs.

(2) the dose in any unrestricted area from external sources does not exceed 0.02 millisievert (2 mrem) in any one hour.

(b) If the registrant permits members of the public to have access to restricted areas, the limits for members of the public continue to apply to those individuals.

The Department may impose additional restrictions on radiation levels in unrestricted areas by registration condition.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.15. Compliance with Dose Limits for Individual Members of the Public

Open this section

(a) The registrant must conduct surveys of radiation levels in unrestricted areas.

(b) The registrant must show compliance with the annual dose limit in 24 RCNY Health Code § 175.14 by demonstrating by measurement or calculation that the total effective dose equivalent to the individual likely to receive the highest dose from the registered operation does not exceed the annual dose limit.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.16. Surveys and Monitoring

Open this section

Each registrant must conduct surveys to comply with this Article to evaluate the magnitude and extent of radiation levels and potential radiological hazards.

(a) The registrant must ensure that instruments and equipment used for quantitative radiation measurements, for radiation survey purposes, are calibrated at intervals not to exceed 12 months for the radiation measured, except when a more frequent interval is specified in this Article.

(b) All personnel dosimeters, except for direct and indirect reading pocket ionization chambers and those dosimeters used to measure the dose to any extremity, that require processing to determine the radiation dose, must be processed and evaluated by a dosimetry processor:

(1) holding current personnel dosimetry accreditation from the National Voluntary Laboratory Accreditation Program of the National Institute of Standards and Technology; and

(2) approved in this accreditation process for the type of radiation or radiations included in the National Voluntary Laboratory Accreditation Program that most closely approximates the type of radiation or radiations for which the individual wearing the dosimeter is monitored.

(c) The registrant must ensure that adequate precautions are taken to prevent a deceptive exposure of an individual monitoring device.

(d) No registrant shall remove an exposure from an individual's exposure record without prior authorization from the Department. To remove an exposure from an individual's exposure record, the registrant must provide the following documentation to the Department:

(1) a letter to the Department indicating the person whose exposure is to be removed along with an investigation into the possible causes for the exposure and a signed note from the individual concurring with the removal of the exposure; and

(2) a copy of the individual's personnel monitoring report along with the investigation the personnel monitor vendor conducted of the exposure. For occurrences where the personnel monitor vendor indicates that a static exposure occurred on the personnel monitoring report sent to the registrant, the latter investigation is waived.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.17. Conditions Requiring Individual Monitoring of External Occupational Dose

Open this section

(a) Each registrant must monitor exposures from sources of radiation to demonstrate compliance with the occupational dose limits of this Article.

(b) Each registrant must supply and require the use of individual monitoring devices by:

(1) adults likely to receive, in 1 year from sources external to the body, a dose in excess of 10 percent of the limits in 24 RCNY Health Code § 175.13; and

(2) minors and declared pregnant workers likely to receive, in 1 year from sources external to the body, a deep dose equivalent in excess of 10 percent of any of the applicable limits in 24 RCNY Health Code § 175.13; and

(3) declared pregnant workers likely to receive during the entire pregnancy, from radiation sources external to the body, a deep dose equivalent in excess of 1 millisievert (0.1 rem); and

(4) all individuals working with medical fluoroscopic equipment, including equipment operators and other staff physically present at the treatment location who are not behind protective shielding.

(5) All personnel monitoring devices used to monitor fluoroscopic radiation exposures must be returned to the vendor for processing on a monthly basis, except that for individuals only working with mini-C arm fluoroscopy equipment, the monitoring devices must be returned at least quarterly.

(6) The registrant must submit the dosimeter for processing with due diligence and never after the time specified by the manufacturer of the dosimeter. Where dosimeters are processed on the registrant's premises, the registrant must require monitored individuals to read their monitors monthly.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.18. Location of Individual Monitoring Devices

Open this section

Each registrant must ensure that individuals who are required to monitor occupational doses in accordance with 24 RCNY Health Code § 175.13 use individual monitoring devices as follows:

(a) an individual monitoring device used for monitoring the dose to the whole body must be worn at the unshielded location of the whole body likely to receive the highest exposure. For individuals wearing a protective apron, when only 1 individual monitoring device is used, it must be located at the neck (collar) outside the protective apron. When a second individual monitoring device is used for the same purpose, it must be located under the protective apron at the waist. The second individual monitoring device is required for a declared pregnant worker.

(b) an individual monitoring device used for monitoring the dose to an embryo/fetus of a declared pregnant worker, pursuant to 24 RCNY Health Code § 175.17, must be located at the waist under any protective apron being worn by the worker;

(c) an individual monitoring device used for monitoring the lens dose equivalent, to demonstrate compliance with 24 RCNY Health Code § 175.13, must be located at the neck (collar), outside any protective apron being worn by the monitored individual, or at an unshielded location closer to the eye;

(d) an individual monitoring device used for monitoring the dose to the extremities, to demonstrate compliance with 24 RCNY Health Code § 175.13, must be worn on the extremity likely to receive the highest exposure. Each individual monitoring device must be oriented to measure the highest dose to the extremity being monitored.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.19. Labeling Radiation Machines

Open this section

Each registrant must ensure that each radiation machine is labeled in a conspicuous manner which cautions individuals that radiation is produced when it is energized.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.20. Records of Radiation Protection Programs

Open this section

(a) Each registrant must maintain records of the radiation protection program, including audits, records of surveys, calibrations, maintenance and modifications (e.g., major software and hardware upgrades) performed on the x-ray system and a copy of all correspondence with the Department regarding the x-ray system.

(b) Unless otherwise indicated, the registrant must retain the records required by subdivision (a) of this section for a minimum of 5 years after the record is made, except that model and serial numbers of all major components and user's manuals for those components, including software, must be maintained for the life of the system.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.21. Determination and Records of Prior Occupational Dose

Open this section

(a) For each individual who is likely to receive, within 1 year, an occupational dose requiring monitoring pursuant to 24 RCNY Health Code § 175.17, the registrant must:

(1) determine the occupational radiation dose received during the current year; and

(2) request in writing the records of cumulative occupational radiation dose.

(b) In complying with the requirements of this section, a registrant may:

(1) accept, as a record of the occupational dose that the individual received during the current year, a written signed statement from the individual, or from the individual's most recent employer for work involving radiation exposure, that discloses the nature and the amount of any occupational dose that the individual received during the current year; and

(2) accept, as the record of cumulative radiation dose, an up-to-date Department form or equivalent, signed by the individual and countersigned by an appropriate official of the most recent employer for work involving radiation exposure, or the individual's current employer, if the individual is not employed by the registrant; and

(3) obtain reports of the individual's dose equivalent from the most recent employer for work involving radiation exposure, or the individual's current employer, if the individual is not employed by the registrant, by telephone, telegram, facsimile, other electronic media or letter. The registrant must request a written verification of the dose data if the authenticity of the transmitted report cannot be established.

(c) The registrant must record the exposure history, with all the following required information:

(1) the form or record must show each period in which the individual received occupational exposure to radiation or radioactive material and must be signed by the individual who received the exposure. For each period for which the registrant obtains reports, the registrant must use the dose shown in the report. For any period in which the registrant does not obtain a report, the registrant must place a notation in the record or equivalent indicating the periods of time for which data are not available.

(2) for the purposes of complying with this requirement, registrants are not required to partition historical dose between external dose equivalent and internal committed dose equivalent. Occupational exposure histories that do not include effective dose equivalent may be used in the absence of specific information on the intake of radionuclides by the individual.

(d) If the registrant is unable to obtain a complete record of an individual's current and previously accumulated occupational dose, the registrant shall assume:

(1) in establishing administrative controls for the current year, that the allowable dose limit for the individual is reduced by 12.5 millisievert (1.25 rem) for each quarter for which records were unavailable and the individual was engaged in activities that could have resulted in occupational radiation exposure; and

(2) that the individual is not available for planned special exposures.

(e) The registrant must retain the records required by this section until the Department terminates each pertinent registration requiring this record. This includes records required under the standards for protection against radiation in effect prior to January 1, 1994.

(f) Upon termination of the registration, the registrant must permanently store such records, or must make provision with the Department for transfer of such records to the Department.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.22. Records of Individual Monitoring Results

Open this section

(a) Recordkeeping. Each registrant must maintain records of doses received by all individuals for whom monitoring is required by this Article. These records must include, when applicable, the deep dose equivalent to the whole body, lens dose equivalent, shallow dose equivalent to the skin, and shallow dose equivalent to the extremities.

(b) The registrant must make entries of the records of individual monitoring results at intervals not to exceed 1 year.

(c) The registrant must maintain individual monitoring results in clear and legible records containing all required information by the Department.

(d) The registrant must maintain the records of dose to an embryo/fetus with the records of dose to the declared pregnant worker. The declaration of pregnancy, including the estimated date of conception, must also be kept on file, but may be maintained separately from the dose records.

(e) The registrant must retain each required form or record until the Department terminates the certified registration or registration requiring the record.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.23. Records of Dose to Individual Members of the Public

Open this section

(a) Each registrant must maintain records sufficient to demonstrate compliance with the dose limit for individual members of the public.

(b) The registrant must retain the records of dose to individual members of the public until the Department terminates each pertinent registration or certified registration requiring the record.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.24. Form of Records

Open this section

(a) Each record required by this Article must be legible throughout the specified retention period and, where required, must be on the appropriate Department form. The record must be the original or a reproduced copy or a microform, provided that the copy or microform is authenticated by authorized personnel and that the microform is capable of producing a clear copy throughout the required retention period, or the record may also be stored in electronic media with the capability for producing legible, accurate and complete records during the required retention period. Records, such as letters, drawings, and specifications, must include all pertinent information, such as stamps, initials and signatures.

(b) The registrant must maintain adequate safeguards against tampering with and loss of records.

(c) The discontinuance or expiration of authorized activities does not relieve any person who possesses any radiation source of responsibility for retaining all records required by this Article.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.25. Notification and Reporting of Events

Open this section

(a) Immediate notification. Notwithstanding other requirements for notification in this Article, each registrant must immediately report each unintended event involving a source of radiation possessed by the registrant that may have caused or threatens to cause any of the following conditions for an individual to receive:

(1) a total effective dose equivalent of 0.25 sievert (25 rem) or more; or

(2) a lens dose equivalent of 0.75 sievert (75 rem) or more; or

(3) a shallow dose equivalent to the skin or extremities or a total organ dose equivalent of 2.5 sievert (250 rem) or more.

(b) Twenty-four hour notification. Each registrant must, within 24 hours of discovery, report to the Department:

(1) Any unintended event involving a registered source of radiation possessed by the registrant that may have caused, or threatens to cause, any of the following conditions for an individual to receive in a period of 24 hours:

(i) a total effective dose equivalent exceeding 0.05 sievert (5 rem); or

(ii) a lens dose equivalent exceeding 0.15 sievert (15 rem); or

(iii) a shallow dose equivalent to the skin or extremities or a total organ dose equivalent exceeding 0.5 sievert (50 rem).

(2) Any medical event as defined in 24 RCNY Health Code § 175.08.

(3) An event in which equipment is disabled or fails to function as intended when:

(i) the equipment is required by regulation or a condition of a registration to prevent exposures exceeding regulatory limits, or to mitigate the consequences of an accident; or

(ii) the equipment is required to be available and operable when it is disabled or fails to function; and

(iii) no redundant equipment is available and operable to perform the required safety function.

(c) Registrants must make the notification required by subdivisions (a) and (b) of this section by initial contact by telephone to the Department and must confirm the initial contact by letter, e-mail or facsimile to the Department. To the extent that the information is available at the time of notification, the information provided in these notifications must include:

(1) the caller's name and call back telephone number;

(2) a description of the event, including date and time;

(3) the exact location of the event;

(4) any personnel radiation exposure data available.

(d) Written reports. Each registrant must submit a written report to the Department within 30 days after learning of:

(1) events for which notification is required by 24 RCNY Health Code § 175.25(a) through (b);

(2) doses in excess of any of the following:

(i) the occupational dose limits for adults in 24 RCNY Health Code § 175.13;

(ii) the occupational dose limits for a minor in 24 RCNY Health Code § 175.13;

(iii) the limits for an embryo/fetus of a declared pregnant worker in 24 RCNY Health Code § 175.13;

(iv) the limits for an individual member of the public in 24 RCNY Health Code § 175.14; or

(v) any applicable limit in the registration;

(3) levels of radiation in:

(i) a restricted area in excess of applicable limits in the registration; or

(ii) an unrestricted area in excess of 10 times the applicable limit set forth in this Article or in the registration, whether or not involving exposure of any individual in excess of the limits in 24 RCNY Health Code § 175.13.

(e) Contents of written reports. Each report required by this section must include, as appropriate:

(1) a description of the event, including the probable cause of the elevated exposures or dose rates and the manufacturer and model number, if applicable, of any equipment that failed or malfunctioned

(2) estimates of each individual's dose;

(3) the levels of radiation involved; and

(4) corrective steps taken or planned to ensure against a recurrence, including the schedule for achieving conformance with applicable limits, ALARA constraints, generally applicable environmental standards and associated registration conditions.

(5) Each report filed pursuant to this section must include for each occupationally overexposed individual: the name, employee ID number if available, and date of birth. With respect to the limit for the embryo/fetus in 24 RCNY Health Code § 175.13, the identifiers should be those of the declared pregnant worker. The report must be prepared so that individually-identifiable information is stated in a separate and detachable portion of the report and not otherwise revealed.

(f) Any written report of a medical event as defined in 24 RCNY Health Code § 175.08 must include a calculation of the resulting radiation dose that was delivered in error, and be forwarded to the registrant's radiation safety committee or the radiation safety officer for their action. The report must be maintained on-site, or readily available for review by the Department during inspection.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.26. Reports to Individuals of Exceeding Dose Limits

Open this section

(a) When a registrant is required to report to the Department any exposure of an identified occupationally-exposed individual, or an identified member of the public to radiation, the registrant must also provide a copy of the report submitted to the Department to the individual. This report must be transmitted at a time no later than the transmittal to the Department.

(b) When necessary or desirable in order to aid in determining the extent of any individual's exposure to radiation subsequent to any radiation accident, or incident, the registrant must make available to such individual appropriate medical evaluation services or appropriate tests and furnish the Department a copy of each report of such evaluation or test.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.27. § 175.39 [Reserved.]

Open this section

BetaNYC's copy has no text for this section. Read 24 RCNY Health Code § 175.27 at American Legal Publishing.

§ 175.40. Registration of Radiation Machine Facilities

Open this section

(a) Registration required. Prior to establishing, maintaining or operating any radiation installation with any radiation equipment in operable condition, or prior to installing such equipment which is intended to be used, the owner, operator or person in charge of such installation must have obtained a current certificate of registration or, for a therapeutic radiation machine as defined in and subject to the requirements of this Article, a certified registration from the Department. Unless otherwise authorized by the Department, no one shall apply x-rays to diagnose or treat any patient's medical condition at a facility that does not possess a current, non- expired certificate of registration issued from the Department. This subdivision does not prohibit the installation of radiation-producing equipment at a facility solely for testing purposes by a QMP, or for testing necessary to prepare reports required for registration.

(b) Application for a certificate of registration must be made to the Department in a manner prescribed by the Department.

(c) Registered facilities at which the owner, operator or location will be changed must apply for a new registration prior to such change.

(d) The applicant for registration for all facilities mandated to have a quality assurance program pursuant to 24 RCNY Health Code § 175.12(b) must:

(1) submit a completed application form and required supporting documents, if any; and,

(2) submit a report prepared by a QMP detailing the results of initial quality assurance tests conducted on all radiation-producing equipment in the facility. In this context, the initial quality assurance tests shall be the sum of all quality assurance tests mandated to be conducted for the facility type at any frequency (for example all daily, monthly, and annually required tests etc.). Also, a radiation protection survey must be conducted and submitted for each room housing a radiographic unit.

(3) designate a radiation safety officer on each application form.

(4) designate a professional practitioner responsible for directing the operation of radiation machines on each healing arts application. The signature of the administrator, president or chief executive officer will be accepted in lieu of a professional practitioner's signature if the facility has more than one professional practitioner (for example, hospitals, large clinics, or multi-practitioner practices).

(e) An application for registration may be denied for any basis provided in this Article.

(f) The Department will not grant a facility's registration until such time as the report described in 24 RCNY Health Code § 175.40(d)(2) contains all mandated quality assurance tests and all corrective actions that may be required therefrom have been completed as determined by the Department.

(1) Upon completion of the review process for the submitted quality assurance tests by the facility, if reasons exist to refuse authorization to register the facility's radiation- producing equipment for clinical usage, the facility shall be notified of the reasons for such a decision by the Department in writing and shall be provided an opportunity to respond.

(2) If requested, the applicant must file all responsive information that the Department finds deficient within 30 days of the Department's request, or the application will be deemed abandoned and void. In the latter case, the applicant must refile the application.

(g) Dental, podiatric and veterinary facilities.

(1) All new dental, podiatric, and veterinary facilities without a current certificate of registration must apply for a new registration prior to the beginning of facility operation. All new dental, podiatric and veterinary facilities shall be prohibited from commencing diagnostic clinical examinations until such time that the facility has either received a certificate of registration from the Department for all such equipment, or the Department has performed a physical inspection of the facility and any deficiencies identified have been corrected, or the Department has reviewed and approved the QMP or CRESO reports to determine that all radiological equipment to be used are operating as intended.

(2) A dental facility possessing a Cone Beam Computed Tomography (CBCT) unit must maintain a quality assurance program for such CBCT unit and shall register such CBCT unit with the Department in accordance with subdivision (d) of this section prior to conducting clinical exams with such CBCT unit.

(h) Renewal registrations. Facilities with current, valid certificates of registration must apply for renewal at least 30 days prior to the expiration of such certificate of registration. Facilities with a certificate of registration that is suspended or revoked, or where the installation is discontinued on or before the expiration of the certificate of registration, may not apply for renewal.

(i) Fees. Fees for each registration and certified registration shall be paid pursuant to 24 RCNY Health Code §§ 5.07 and 5.09(f).

(j) Duration of registrations. A certificate of registration shall be issued for a limited period of time extending from the date of issuance to the date of expiration as specified on the certificate of registration. Registration validity shall not exceed 2 years except that the Department, at its discretion, may issue a certificate of registration for a longer period of time in order to stagger expiration dates for administrative purposes and may charge a proportionate increase in fees to reflect this.

(k) Expiration of registrations.

(1) The registration issued for a radiation installation shall expire and may be required to be surrendered to the Department upon:

(i) failure to renew by the expiration date specified on the certificate of registration; or

(ii) revocation by the Commissioner; or

(iii) a change of the person to whom the certificate of registration is issued; or

(iv) a change in address of the radiation installation if it is not a mobile unit; or

(v) a change in the name of the installation; or

(vi) the discontinuance of the installation.

(2) Notwithstanding paragraph (1) of this subdivision, if a registrant whose registration has expired indicates in writing to the Department that they are in the process of completing and files a proper registration application renewal form with the Department, or properly files for a new and superseding registration, at least 30 days prior to the stated expiration date, such registration shall not be deemed to have expired until the Department has decided upon such renewal application.

(l) Suspension and revocation of registrations. A registration may be suspended or revoked for any basis provided in this Article, including pursuant to 24 RCNY Health Code § 5.17, or if the Commissioner finds that:

(1) the information submitted in the application is materially incorrect or incomplete;

(2) the installation is, has been or will be established, maintained, or operated in violation of this Article, or any other applicable law, rule, regulation, order or condition;

(3) the certificate of registration has not been issued correctly; or

(4) the fees for registration or inspections and adjudicated fines have not been paid as required.

(m) A certificate of registration issued for a radiation installation must be posted in accordance with the provisions of 24 RCNY Health Code § 5.15. If posting is not practicable, the registrant may post a notice stating where it may be examined.

(n) The operator of a radiation installation must keep its registration information current by reporting to the Department of any change affecting the registration within 10 days of such change.

(o) The registration issued to a facility does not imply endorsement or approval by the Department and must not be used to advertise or promote business.

(p) A certificate of registration or certified registration is not transferable or assignable.

(q) The Department may refuse to issue, or may suspend or revoke, a certificate of registration for any facility that refuses to allow the Department to conduct an inspection of all of the facility's x-ray equipment or records or refuses or is unable to correct any violations of this Article noted during an inspection.

(r) Exemptions. Registration with the Department is not required for:

(1) radiation equipment constructed so that it cannot emit radiation at a level greater than 0.5 milliroentgen per hour, measured 5 cm (2 in.) from any accessible surface thereof, and averaged over an area of 10 cm 2 (1.55 in 2 ) provided, however, that such exemption shall not apply to the testing or servicing of such equipment during its production; or

(2) radiation equipment during its storage, shipment, retail sale or other similar use (but not including installation) during which such equipment is not connected to a voltage source and does not emit radiation, provided however, that such equipment is not exempt from the labeling requirement of 24 RCNY Health Code § 175.20.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.41. Certified Registration for Therapeutic Radiation Machines

Open this section

(a) Certified registration required. All facilities with therapeutic radiation machines as defined in and subject to the requirements of this Article must maintain a certified registration for such therapeutic radiation machines from the Department in accordance with the provisions of this section.

(b) Certified registration application.

(1) An application for a certified registration must be made to the Department in a manner prescribed by the Department

(2) If the application is for use sited in a medical institution, only a person serving as a principal officer or director on the institution's executive management may apply; for use not sited in a medical institution, a professional practitioner may apply.

(3) When a change affecting a radiation source or installation subject to the certified registration requirements of this section is considered by a registrant, including but not limited to changes ordered pursuant to this Article, so that the information on file with the Department will no longer be accurate, then the registrant must so inform the Department in writing:

(i) for administrative changes, such as a change in business name, such notification must be made to the Department within 10 days of such change.

(ii) for all other changes, an amendment must be requested and received pursuant to this section.

(iii) failure to notify the Department of a change of ownership or address of a radiation installation may result in suspension or revocation of the installation's certified registration.

(4) At any time after the filing of an application for a certified registration, the Department may require the applicant to submit a supplementary information statement to enable the Department to determine whether such application should be approved or denied, or whether a previously issued registration should be amended, suspended or revoked.

(5) Each application or supplementary information statement must be signed by either the applicant personally or a person duly authorized by the applicant acting as its agent to sign on the applicant's behalf.

(6) The Department may approve an application for a certified registration if the Department determines that the following requirements have been met:

(i) the applicant's proposed use, equipment, facilities and procedures can be reasonably expected to protect health and safety and minimize danger to life and property from radiation hazards; and

(ii) the applicant's instrumentation is appropriate for detecting and measuring the type of radiation produced (either directly or indirectly) by the radiation source requested in the application; and

(iii) the applicant or the applicant's personnel are qualified by licensure, training and experience to use such radiation source for the purposes covered by the application so as to protect health and safety and minimize danger to life and property from radiation hazards; and

(iv) the applicant submits sufficient information to support a reasonable determination that the requirements of this Article will be met.

(7) Certified registrations issued by the Department pursuant to application shall be in the form of a written authorization permitting possession and use of radiation therapy machines. Such possession and use shall be subject to ongoing compliance with all applicable provisions of this Article and all conditions as stated on the certified registration.

(c) Certified registration; expiration, termination and amendment.

(1) Except as otherwise provided in this Article, or authorized by the Department, each certified registration shall expire on the expiration date stated on the certified registration. If any current certified registrant duly files with the Department an application in proper form for renewal of such certified registration, or for a new and superseding certified registration, not less than 30 days prior to the stated expiration date, such certified registration shall not be deemed to have expired until the Department has decided such renewal application.

(2) The Department may terminate any certified registration upon the written request of the registrant.

(3) The Department may at any time set forth in any certified registration or incorporate by reference therein, additional conditions, restrictions or requirements applicable to the registrant's transfer, receipt, possession or use of any radiation source covered by such certified registration in order to protect the public health and safety and to minimize danger to life and property from radiation hazards.

(4) Any certified registration may be amended or revoked by the Department by reason of amendment of this Article, or any other applicable law or regulation.

(5) Any certified registration may be suspended or revoked by the Department for any basis provided in this Article, including but not limited to, the following:

(i) any material misstatement in the application or in any supplementary statement thereto;

(ii) any condition revealed by such application, supplementary statement, report, record, inspection, investigation or other means, which would warrant the Department's refusal to grant a certified registration on an original application; or

(iii) any violation or failure to observe any condition of such certified registration, this Article, or any other applicable law, rule, regulation or order now or hereafter in effect.

(6) A registrant must apply for, and must have received approval for, a certified registration amendment before:

(i) permitting anyone not listed on the registrant's certified registration to work as an authorized user under the certified registration;

(ii) permanently changing the radiation safety officer;

(iii) making any change in the treatment room shielding;

(iv) making any change in the location of the therapeutic radiation machine within the treatment room;

(v) using the therapeutic radiation machine in a manner that could result in increased radiation levels in areas outside the treatment room;

(vi) relocating the therapeutic radiation machine;

(vii) allowing an individual not listed on the registrant's certified registration to perform the duties of the QMP, except during the temporary absence of the QMP when a person who is otherwise qualified to perform such duties may perform such duties; such temporary absence must not exceed 60 days; or

(viii) changing non-administrative statements, representations or procedures incorporated by reference into the certified registration.

(7) Any application by a registrant for an amendment of a certified registration must be filed in writing with the Department and must set forth in detail the reasons for such requested amendment.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.42. Registration of Mobile Service Operations

Open this section

For purposes of this section, mobile service operations means an x-ray unit of any type that is used in a van or similar vehicle to conduct x-ray examinations outside a fixed location. In addition to the requirements of 24 RCNY Health Code § 175.40, the applicant must provide the following information:

(a) an established main location where the machines, records, etc. will be maintained for inspection. This must be a street address, not a post office box number.

(b) a sketch or description of the normal configuration of each radiation machine's use, including the operator's position and any ancillary personnel's location during exposures. If a mobile van is used with a fixed unit inside, furnish the floor plan indicating protective shielding and the operator's location; and

(c) a current copy of the applicant's operating and safety procedures, including radiological practices for protection of patients, operators, employees and the general public.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.43. Assembler or Transfer Obligation

Open this section

(a) Any person who sells, leases, transfers, lends, disposes, assembles or installs radiation machines in New York City must notify the Department within 15 days of:

(1) the name and address of persons who have received these machines;

(2) the manufacturer, model, and serial number of each radiation machine transferred; and

(3) the date of transfer of each radiation machine.

(b) No person shall make, sell, lease, transfer, lend, assemble, or install radiation machines or the supplies used in connection with such machines unless such supplies and equipment when properly placed in operation meet the requirements of this Article and any other applicable law.

(c) The submission to the Department of FDA Form 2579 (Report of Assembly of a Diagnostic X-ray System) shall be deemed to meet all the requirements of this section.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.44. Requirements for Technical Reports

Open this section

(a) All surveys, audits, reports, or other work ("technical report") performed by a QMP or CRESO as required by this Article must be reviewed and signed by such QMP or CRESO.

(b) If the Department determines that any technical report of any QMP or CRESO providing services required by this Article are inadequate to assess radiation exposures, the Department may require such technical report to be revised or re-done according to specifications provided by the Department, or if this is not satisfactory, the Department may require the registrant or licensee to have such technical report performed by another QMP or CRESO. If the Department makes such a determination, it shall notify such QMP or CRESO of such determination and allow such QMP or CRESO an opportunity to be heard before the Department prior to any notification by the Department of its determinations, if any, to such individual's appropriate certifying agency.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.45. [Reserved.]

Open this section

BetaNYC's copy has no text for this section. Read 24 RCNY Health Code § 175.45 at American Legal Publishing.

§ 175.46. Requirements for an Operator's Booth

Open this section

(a) Stationary radiographic systems. Stationary radiographic systems must have the x- ray control, including the exposure switch, permanently mounted in a protected area so that the operator must remain in that protected area during the entire exposure.

(b) Mobile, portable, podiatric, dental (except CBCT), and mammographic radiographic installations are exempt from the requirements of 24 RCNY Health Code § 175.46(d) through (g), and must meet the requirements in 24 RCNY Health Code § 175.46(h) or (i).

(c) Dual-energy X-ray absorptiometry (DXA) systems are exempt from the requirements of this section, and must meet the requirements of 24 RCNY Health Code § 175.52.

(d) Space requirements.

(1) The operator must be allotted at least 0.70 m 2 (7.5 square feet) of unobstructed floor space in the booth;

(2) The operator's booth may be any geometric configuration with all dimensions at least 0.6 m (2 feet);

(3) Paragraphs (1) and (2) of this subdivision only apply to installations constructed after July 1, 2021.

(4) The space must not have any obstruction near the x-ray control panel, such as overhang, cables, or other similar obstructions;

(5) The booth must be located or constructed such that unattenuated direct scatter radiation originating on the examination table or at the wall-mounted image receptor will not reach the operator's position in the booth.

(e) Structural requirements.

(1) The booth walls must be permanently fixed barriers of at least 2.1 m (7 feet) high;

(2) When a door or movable panel is used as an integral part of the booth structure, it must have an interlock which will prevent an exposure when the door or panel is not closed;

(3) Shielding must be provided to meet the requirements for the occupational radiation exposure requirements of this Article.

(f) Radiation exposure control placement. The radiation exposure control for the system must be fixed within the booth and:

(1) must be at least 1.0 m (40 inches) from any point subject to direct scatter, leakage or primary beam radiation; and,

(2) must allow the operator to use the majority of the available viewing windows.

(g) Viewing system requirements. Each booth must have at least one viewing device which will:

(1) be so placed that the operator can view the patient during any exposure; and

(2) be so placed that the operator can have full view of any occupant of the room and should be so placed that the operator can view any entry into the room. If any door which allows access to the room cannot be seen from the booth, then outside that door there must be an "x-ray on" warning sign that will be lighted whenever an x-ray exposure is initiated. Alternatively, an interlock must be present such that exposures are prevented when the door is open.

(3) When the viewing system is a window, the following requirements also apply:

(i) the window must have a viewing area of at least 0.09 m 2 (1 square foot);

(ii) regardless of size or shape, at least 0.09 m 2 (1 square foot) of the window area must be centered no less than 0.6 m (2 feet) from the open edge of the booth and no less than 1.5 m (5.0 feet) from the floor;

(iii) the window must have at least the same lead equivalence as that required in the booth's wall in which it is mounted.

(4) When the viewing system is by mirrors, the mirrors must be located to allow the operator to view the patient during any exposure and allow full view of any occupant of, or entry into the room.

(5) When the viewing system is by electronic means, the camera shall be located to allow the operator to view the patient during any exposure and allow full view of any occupant of, or entry into the room.

(h) Mobile, portable, podiatric and dental radiographic installations (except CBCT), excluding mammographic systems.

(1) Mobile, portable, podiatric and dental x-ray equipment must allow an operator to stand at least 2 m (6.5 ft.) from the patient or behind a protective barrier of at least 2.1 m (7 feet) high, and not in the path of the primary x-ray beam whenever an x-ray exposure is initiated.

(2) Mobile and portable x-ray systems, excluding dental and podiatric systems, that are used continuously for greater than one week in the same location shall be deemed a fixed radiographic installation and must meet the operator protection standards for fixed radiographic equipment.

(3) Each operator of a mobile or portable radiographic x-ray unit, excluding dental and podiatric units, must be provided with personnel monitoring as provided in 24 RCNY Health Code § 175.17 and must wear a protective garment of at least 0.25 mm lead equivalent.

(i) Mammographic installations. The operator of the mammographic equipment must initiate x-ray exposures from the control console of the mammographic equipment with protective shielding for the operator that meets the following criteria:

(1) the shielding must be a height of 2.1 m (7 ft.) from the floor, with the lower edge not more than 7.5 cm (3 in.) from the floor. The shielding must be constructed as a permanent operator shield such that the operator can stand completely within the shielded area during the exposure; and

(2) the exposure control must be permanently fixed on the mammographic control console; and

(3) the operator must be able to communicate with and view the patient from the operator's protected position during the exposure.

(j) Operator protective garments.

(1) The facility must include a written policy and procedure in the quality assurance manual that conforms to the manufacturer's recommended care and use policy for lead protective garments and is adhered to on a continuing basis. This policy, at a minimum, must describe the training of Licensed Radiologic Technologists (LRTs) on the proper care and usage of protective garments; how storage sites for lead protective garments will be evaluated and maintained; and include procedures for how LRTs report lead protective garment problems to the radiation safety officer.

(2) All protective garments must be checked annually for defects such as holes (not including pinholes that do not affect the performance of the protective garment), cracks, and tears by using one or more of the following methods: visual investigation, tactile investigation, or x-ray imaging. Protective garments that are used by operators conducting fluoroscopic procedures must be checked using all three methods listed. If a defect is found, the lead protective garment must be removed from service and either replaced or repaired as needed to conform to the manufacturers' specifications.

(k) Radiation exposure control.

(1) Exposure initiation. Means must be provided to initiate the radiation exposure by a deliberate action on the part of the operator, such as the depression of a switch. Radiation exposure must not be initiated without such an action. In addition, it must not be possible to initiate an exposure when the timer is set to a "zero" or "off" position if either position is provided.

(2) Exposure indication. Means must be provided for visual indication observable at or from the operator's protected position whenever x-rays are produced. In addition, an audible signal to the operator must indicate that the exposure has terminated.

(l) Operator and ancillary personnel protection for veterinary systems. All stationary, mobile or portable x-ray systems used for veterinary work must be provided with either a 2 meter (6.5 feet) high protective barrier for operator protection during exposures, or must allow the operator to be at least 2 meters (6.5 feet) from the tube housing assembly during exposures. Otherwise, in cases where animals are held, the operator and ancillary personnel must be protected by a minimum of 0.25 mm lead equivalent from scatter radiation and 0.5 mm from the useful beam.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.47. General Requirements for All Radiation Equipment

Open this section

(a) All x-ray equipment must be installed and operated in accordance with the equipment manufacturer's specifications. If the registrant is required to have a QA program pursuant to 24 RCNY Health Code § 175.12(b)(1), and if the manufacturer's specifications are not available, the registrant's QMP or RSO must establish specifications for equipment use and document the specifications in the registrant's QA Manual. If the Department finds that the specifications present unacceptable tolerances, the Department shall require the registrant to utilize new specifications and shall notify the registrant of such in writing.

(b) All functional x-ray units registered by the Department shall be subject to inspection by Department staff, or by individuals directed by the Department to inspect such units, such as CRESOs.

(c) Radiation safety requirements. The registrant shall be responsible for directing the operation of the x-ray system under their administrative control and must assure that the requirements of this Article are met in the operation of the x-ray system.

(d) A current copy of 24 RCNY Health Code Article 175 must be maintained and readily accessible by the registrant either in hard copy or electronic format.

(e) Registrants required to have a QA program pursuant to 24 RCNY Health Code § 175.12(b)(1) must have a written radiation safety program as part of their QA program. The radiation safety program must include, but not be limited to, the following:

(1) that the use of ionizing radiation within its purview is performed in accordance with existing laws and regulations.

(2) that all persons are protected as required by this Article.

(3) that upon discovery of a medical event (as defined in this Article), the registrant must follow the applicable requirements of 24 RCNY Health Code § 175.25 concerning notification to the Department.

(f) If an x-ray system does not meet the provisions of this Article, then the registrant must correct such non-compliance, or initiate necessary corrective action, within 30 days of such discovery.

(g) Individuals operating the x-ray systems must meet all licensure, training and experience qualifications required by the Department.

(h) A sufficient number of protective apparel (e.g., aprons, gloves, collars) and shields must be available to provide the necessary radiation protection for all patients and personnel who are involved with x-ray operations.

(i) The registrant must use auxiliary equipment designed to minimize patient and personnel exposure commensurate with the needed diagnostic information.

(j) Neither the x-ray tube housing nor the collimating device shall be held during an exposure. Exceptions may be allowed for Department-approved devices specifically designed to be hand-held in the area of patient dental exams. The Department shall maintain a list of hand- held dental units that are approved for clinical exams in New York City, or may accept the list of such hand-held dental units as approved by New York State Department of Health, at the Department's discretion.

(k) The useful x-ray beam must be limited to the area of clinical interest. For x-ray units not utilizing PBL systems for clinical imaging and not using cones or diaphragms for beam restriction, the clinical x-ray field must be less than size of the image receptor on four of four sides of the image receptor. For all digital image receptors, the size of the clinical image must not be digitally manipulated as to render its original dimensions different from the clinical image size when the image is archived.

(l) Consideration must be given to selecting the appropriate technique and employing available dose reduction methods and technologies across all patient sizes and clinical indications. For registrants utilizing manual selection of technique settings for clinical x-ray exams, this means a technique chart that employs technique settings for thin, average and heavy patient sizes. In the case where children less than 18 years of age are radiographed, the minimal technique setting should correspond to patients of 1-years old, 5-years old and 10-years old for exams most likely to be administered, e.g., AP chest and abdomen exams. In all such cases, the Entrance Skin Exposure (ESE) must be directly or indirectly determined for all clinical techniques set. At a minimum, these technique charts along with ESEs must include:

(1) patient's (adult and pediatric, if appropriate) body part and anatomical size;

(2) technique factors;

(3) type of image receptor used;

(4) source to image receptor distance used (except for dental intraoral radiography), and

(5) position of the grid for the x-ray exam, i.e., the grid is either removed from the x-ray beam or is in the x-ray beam.

(m) A facility must have a documented procedure in place for verification of patient identity and exam to be performed, including identification of the appropriate body part.

(n) The registrant must create and make available to x-ray operators written safety procedures, including instructions for patient holding and any restrictions of the operating technique required for the safe operation of the particular x-ray system. The operator must be able to demonstrate familiarity with these procedures. Patient holding must be restricted to radiographic examinations with the exception that holding of patients shall be prohibited for all fluoroscopic exams and patient CT exams with the exception of hospital emergency rooms and hospital trauma centers.

(o) The registrant must restrict the presence of individuals in the x-ray room of the patient being examined to those required or in training for the medical procedure, or the parent or guardian of a patient while the x-ray tube is energized. Other than the patient being examined, the following applies to all individuals in the x-ray room:

(1) all persons must be positioned such that no part of the body will be struck by the useful beam unless protected by not less than 0.25 millimeter lead equivalent material;

(2) If the procedure results in secondary or scatter radiation in excess of 0.02 mSv (2 mrem) in any one hour at the position of these persons, they must be protected from the direct scatter radiation by whole body protective barriers of not less than 0.25 millimeter lead equivalent material or must be positioned so that the 0.02 mSv (2 mrem) in any one hour limit is met.

(p) Individuals must not be exposed to the useful beam except for healing arts purposes and unless such exposure has been authorized by a professional practitioner of the healing arts. This provision specifically prohibits deliberate exposure for the following purposes:

(1) exposure of an individual for training, demonstration, or other non-healing arts purposes; and

(2) exposure of an individual for the purpose of healing arts screening except as authorized by the Department.

(q) X-ray patient logbook. Each facility must maintain a written or electronic record containing the patient's name, the type of examinations, and the dates the examinations were performed for all radiographic (except dental, podiatric and veterinary exams) and fluoroscopic patient exams. The administration of contrast agents as part of the patient exam must be noted in the patient logbook to state that IV contrast was administered. All adverse effects to injected contrast agents must be reported to the NY State Health Department, as required by law.

(r) Sealing x-ray equipment. Sealing of x-ray units must be done only by the Department for x-ray units, of any type, that poses a hazard to the patient or the operator. No x- ray units sealed by the Department shall be put in use for clinical exams without the approval of the Department.

(s) Leakage radiation from the diagnostic source assembly. The leakage radiation from the diagnostic source assembly measured at a distance of 1 meter in any direction from the source must not exceed 0.88 milligray (mGy) air kerma (vice 100 milliroentgen (mR) exposure) in 1 hour when the x-ray tube is operated at its leakage technique factors. If the maximum rated peak tube potential of the tube housing assembly is greater than the maximum rated peak tube potential for the diagnostic source assembly, positive means must be provided to limit the maximum x-ray tube potential to that of the diagnostic source assembly.

(t) Technique indicators.

(1) For x-ray equipment capable of displaying technique factors, the technique factors to be used during an exposure must be indicated before the exposure begins. If automatic exposure controls are used, the technique factors which are set prior to the exposure must be indicated.

(2) The requirement of paragraph (1) of this subdivision may be met by permanent markings on equipment having fixed technique factors. Indication of technique factors must be visible from the operator's position except in the case of spot films made by the fluoroscopist.

(3) The accuracy of the technique factors for the x-ray unit (e.g., indicated kilovoltage peak (kVp), timer accuracy) must meet manufacturer specifications. In the absence of a manufacturer specification, the technique factor accuracy must be within ±10 percent.

(u) Beam quality.

(1) The half value layer (HVL) of the useful beam for a given x-ray tube potential shall not be less than the values shown in Table 1 of this subdivision. If it is necessary to determine such half-value layer at an x-ray tube potential which is not listed in Table 1, linear interpolation or extrapolation may be made. Positive means must be provided to ensure that at least the minimum filtration needed to achieve beam quality requirements is in the useful beam during each exposure. In the case of a system which is to be operated with more than one thickness of filtration, this requirement can be met by a filter interlocked with the kilovoltage selector which will prevent x-ray emissions if the minimum required filtration is not in place. In no case shall an x-ray unit failing to meet the minimum filtration standards in Table 1 conduct clinical patient exams until the x-ray unit is in compliance with Table 1.

TABLE 1*

X-Ray Tube Voltage (kilovolt peak) Design Operating Range Measured Operating Potential Minimum HVL (mm in Aluminum) Specified Dental Systems 1 Other X-Ray Systems (older) 2 Other X-Ray Systems (newer) 3 Below 51 30 1.5 0.3 0.3 40 1.5 0.4 0.4 50 1.5 0.5 0.5 51 to 70 51 1.5 1.2 1.3 60 1.5 1.3 1.5 70 1.5 1.5 1.8 Above 70 71 2.1 2.1 2.5 80 2.3 2.3 2.9 90 2.5 2.5 3.2 100 2.7 2.7 3.6 110 3.0 3.0 3.9 120 3.2 3.2 4.3 130 3.5 3.5 4.7 140 3.8 3.8 5.0 150 4.1 4.1 5.4 1 Dental x-ray systems designed for use with intraoral image receptors and manufactured after December 1, 1980. 2 Dental x-ray systems designed for use with intraoral image receptors and manufactured before or on December 1,1980, and all other x-ray systems subject to this section and manufactured before June 10, 2006. 3 All x-ray systems, except dental x-ray systems designed for use with intraoral image receptors, subject to this section and manufactured on or after June 10, 2006. * Source: 21 C.F.R. § 1020.30(m)

(2) Measuring compliance. For capacitor energy storage equipment, compliance shall be determined with the maximum selectable quantity of charge per exposure.

(v) Battery charge indicator. On battery-powered generators, visual means must be provided on the control panel to indicate whether the battery is in a state of charge adequate for proper operation.

(w) Modification of certified diagnostic x-ray components and systems.

(1) Diagnostic x-ray components and systems certified in accordance with 21 C.F.R. Part 1020 must not be modified except with certified components.

(2) The owner who causes such modification must record the date and the details of the modification in the system records and maintain this information, and the modification of the x-ray system must not result in a failure to comply with this Article.

(x) Multiple tubes. Where two or more radiographic tubes are controlled by one exposure switch, the tube which has been selected must be clearly indicated prior to initiation of the exposure. Only the selected tube can be energized. This indication must be both on the x-ray control panel and at or near the tube housing assembly which has been selected.

(y) Mechanical support of tube head. The tube housing assembly supports must be adjusted such that the tube housing assembly will remain stable during an exposure unless tube housing movement is a designed function of the x-ray system.

(z) Locks. All position locking, holding, and centering devices on x-ray system components and systems must function as intended.

(aa) Maintaining compliance. Diagnostic x-ray systems and their associated components used on humans and certified pursuant to the Federal Performance Standard for Diagnostic X-Ray Systems (21 C.F.R. § 1020.30) must be maintained in compliance with applicable requirements of that standard.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.48. Specific Requirements for Radiographic X-ray Equipment

Open this section

The requirements of this section apply to all non-dental registrants using diagnostic x-ray equipment.

(a) Acceptance testing. Each registrant must have acceptance testing conducted on all radiographic x-ray units with the exception of dental, podiatric, and bone densitometer units, prior to clinical patient exams being conducted with the designated x-ray units. The acceptance testing must be conducted by a QMP and the report must be provided to the registrant. All non- compliance issues noted in this report must be corrected prior to clinical use of the unit. The acceptance testing report must verify the stated manufacturer's tolerances for all machine testing. If manufacturer tolerances are absent, the registrant's QMP must develop tolerances that must be used in subsequent QA testing by the registrant and must be so noted in the quality assurance manual.

(b) Control and indication of technique factors.

(1) Timers. Means must be provided to terminate the exposure at a preset time interval, a preset product of current and time, a preset number of pulses, or a preset radiation exposure to the image receptor.

(i) Except during serial radiography, the operator must be able to terminate the exposure at any time during an exposure of greater than one-half second. Except during panoramic dental radiography, termination of exposure must cause automatic resetting of the timer to its initial setting or to zero. It must not be possible to make an exposure when the timer is set to a zero or off position if either position is provided.

(ii) During serial radiography, the operator must be able to terminate the x-ray exposure at any time, but means may be provided to permit completion of any single exposure of the series in process.

(2) Automatic exposure controls. When an automatic exposure control is provided:

(i) indication must be made on the control panel when this mode of operation is selected;

(ii) when the x-ray tube potential is equal to or greater than 51 kilovolts peak (kVp), the minimum exposure time for field emission equipment rated for pulse operation must be equal to or less than a time interval equivalent to two pulses and the minimum exposure time for all other equipment must be equal to or less than 1/60 second or a time interval required to deliver 5 milliampere-seconds (mAs), whichever is greater;

(iii) either the product of peak x-ray tube potential, current, and exposure time must be limited to not more than 60 kilowatt-seconds (kWs) per exposure or the product of x-ray tube current and exposure time must be limited to not more than 600 mAs per exposure, except when the x-ray tube potential is less than 51 kVp, in which case the product of x-ray tube current and exposure time must be limited to not more than 2,000 mAs per exposure; and

(iv) a visible signal must indicate when an exposure has been terminated at the limits described in subparagraph (iii) of this paragraph, and manual resetting must be required before further automatically timed exposures can be made.

(c) Reproducibility.

(1) Coefficient of variation. For any specific combination of selected technique factors, the estimated coefficient of variation of the air kerma must be no greater than 0.05.

(2) Measuring compliance. Determination of compliance must be based on 10 consecutive measurements taken within a time period of 1 hour. Equipment manufactured after September 5, 1978, must also have all variable controls for technique factors adjusted to alternate settings and reset to the test setting after each measurement. For equipment having automatic exposure controls, compliance shall be determined with a sufficient thickness of attenuating material in the useful beam such that the technique factors can be adjusted to provide individual exposures of a minimum of 12 pulses on field emission equipment rated for pulsed operation or no less than one-tenth second per exposure on all other equipment.

(3) Alternatively, the reproducibility of any technique value may be determined by taking 5 consecutive measurements and utilizing the formula given below:

Reproducibility = (maximum measured value - minimum measured value)

Average of the measured five values

The calculated reproducibility shall be equal to ± 10 percent for compliance.

(d) Linearity. The following requirements apply for any fixed x-ray tube potential within the range of 40 percent to 100 percent of the maximum rated. In regard to paragraphs (1) through (3) in this subdivision below, measurements can be made in mR instead of mGy.

(1) Equipment having independent selection of x-ray tube current (mA). The average ratios of air kerma to the indicated milliampere-seconds product (mGy/mAs) obtained at any two consecutive tube current settings must not differ by more than 0.10 times their sum. This is: |X1 - X2 £ | 0.10(X1 + X2); where X1 and X2 are the average mGy/mAs values obtained at each of two consecutive mAs selector settings or at two settings differing by no more than a factor of 2 where the mAs selector provides continuous selection.

(2) Equipment having selection of x-ray tube current-exposure time product (mAs). For equipment manufactured after May 3, 1994, the average ratios of air kerma to the indicated milliampere-seconds product (mGy/mAs) obtained at any two consecutive mAs selector settings must not differ by more than 0.10 times their sum. This is: |X1 - X2 £ | 0.10(X1 + X2); where X1 and X2 are the average mGy/mAs values obtained at each of two consecutive mAs selector settings or at two settings differing by no more than a factor of 2 where the mAs selector provides continuous selection.

(3) Measuring compliance. Determination of compliance will be based on at least 3 exposures, made within 1 hour, at each of the two settings. These two settings may include any two focal spot sizes except where one is equal to or less than 0.45 mm and the other is greater than 0.45 mm. For purposes of this requirement, focal spot size is the focal spot size specified by the x-ray tube manufacturer.

(e) Field limitation and alignment for mobile, portable, and stationary general purpose x-ray systems. Except when spot-film devices are in service, mobile, portable, and stationary general purpose radiographic x-ray systems must meet the following requirements:

(1) Variable x-ray field limitation. A means for stepless adjustment of the size of the x-ray field must be provided. Each dimension of the minimum field size at an SID of 100 cm must be equal to or less than 5 cm.

(2) Visual definition.

(i) Means for visually defining the perimeter of the x-ray field must be provided. The total misalignment of the edges of the visually defined field with the respective edges of the x-ray field along either the length or width of the visually defined field must not exceed 2 percent of the distance from the source to the center of the visually defined field when the surface upon which it appears is perpendicular to the axis of the x-ray beam.

(ii) When a light localizer is used to define the x-ray field, it must provide an average illuminance of not less than 160 lux (15 footcandles) at 100 cm or at the maximum SID, whichever is less. The average illuminance shall be based on measurements made in the approximate center of each quadrant of the light field. Radiation therapy simulation systems are exempt from this requirement.

(iii) The edge of the light field at 100 cm or at the maximum SID, whichever is less, must have a contrast ratio, corrected for ambient lighting, of not less than 4 in the case of beam-limiting devices designed for use on stationary equipment, and a contrast ratio of not less than 3 in the case of beam-limiting devices designed for use on mobile and portable equipment. The contrast ratio is defined as I1/I2, where I1 is the illuminance 3 mm from the edge of the light field toward the center of the field; and I2 is the illuminance 3 mm from the edge of the light field away from the center of the field.

(f) Field indication and alignment on stationary general purpose x-ray equipment. Except when spot-film devices are in service, stationary general purpose x-ray systems must meet the following requirements, in addition to those prescribed in subdivision (e) of this section:

(1) Means must be provided to indicate when the axis of the x-ray beam is perpendicular to the plane of the image receptor, to align the center of the x-ray field with respect to the center of the image receptor to within 2 percent of the SID, and to indicate the SID to within 2 percent;

(2) The beam-limiting device must numerically indicate the field size in the plane of the image receptor to which it is adjusted;

(3) Indication of field size dimensions and SIDs must be specified in centimeters or inches and must be such that aperture adjustments result in x-ray field dimensions in the plane of the image receptor which correspond to those indicated by the beam-limiting device to within 2 percent of the SID when the beam axis is indicated to be perpendicular to the plane of the image receptor; and

(4) Compliance measurements will be made at each SID in common clinical use (such as SIDs of 100, 150, and 200 cm or 36, 40, 48, 72 inches) and with at least one of the commonly used image receptor dimensions (such as nominal image receptor dimensions of 13, 18, 24, 30, 35, 40, and 43 cm or 5, 7, 8, 9, 10, 11, 12, 14, and 17 inches), or at any other specific dimensions at which the beam-limiting device or its associated diagnostic x-ray system is uniquely designed to operate.

(g) Field limitation on x-ray equipment other than general purpose radiographic systems.

(1) X-ray systems designed for one image receptor size. Radiographic equipment designed for only one image receptor size at a fixed SID must be provided with means to limit the field at the plane of the image receptor to dimensions no greater than those of the image receptor, and to align the center of the x-ray field with the center of image receptor to within 2 percent of the SID, or must be provided with means to both size and align the x-ray field such that the x-ray field at the plane of the image receptor does not extend beyond the edge of the image receptor.

(2) Other x-ray systems. Radiographic systems not specifically covered in subdivisions (e) and (f) of this section, and paragraph (1) of this subdivision, which are also designed for use with extraoral image receptors and when used with an extraoral image receptor, must be provided with means to limit the x-ray field in the plane of the image receptor so that such field does not exceed each dimension of the image receptor by more than 2 percent of the SID, when the axis of the x-ray beam is perpendicular to the plane of the image receptor. In addition, means must be provided to align the center of the x-ray field with the center of the image receptor to within 2 percent of the SID, or means must be provided to both size and align the x-ray field such that the x-ray field at the plane of the image receptor does not extend beyond any edge of the image receptor. These requirements may be met with:

(i) A system which performs in accordance with subdivisions (e) and (f) of this section or when alignment means are also provided, may be met with either;

(ii) An assortment of removable, fixed-aperture, beam-limiting devices sufficient to meet the requirement for each combination of image receptor size and SID for which the unit is designed. Each such device must have clear and permanent markings to indicate the image receptor size and SID for which it is designed; or

(iii) A beam-limiting device having multiple fixed apertures sufficient to meet the requirement for each combination of image receptor size and SID for which the unit is designed. Permanent, clearly legible markings must indicate the image receptor size and SID for which each aperture is designed and must indicate which aperture is in position for use.

(h) Positive beam limitation (PBL). The requirements of this subdivision apply to radiographic systems which contain PBL and which the registrant has not disabled.

(1) Field size. When a PBL system is provided, it must prevent x-ray production when:

(i) Either the length or width of the x-ray field in the plane of the image receptor differs from the corresponding image receptor dimension by more than 3 percent of the SID; or

(ii) The sum of the length and width differences stated in subparagraph (i) of this paragraph without regard to sign exceeds 4 percent of the SID.

(iii) The beam-limiting device is at an SID for which PBL is not designed for sizing.

(2) Conditions for PBL. When provided and if the registrant has not disabled it, the PBL system must function as described in subparagraph (i) of paragraph (1) of this subdivision. whenever all the following conditions are met:

(i) The image receptor is inserted into a permanently mounted cassette holder;

(ii) The image receptor length and width are less than 50 cm;

(iii) The x-ray beam axis is within ±3 degrees of vertical and the SID is 90 cm to 130 cm inclusive; or the x-ray beam axis is within ±3 degrees of horizontal and the SID is 90 cm to 205 cm inclusive;

(iv) The x-ray beam axis is perpendicular to the plane of the image receptor to within ±3 degrees; and

(v) Neither tomographic nor stereoscopic radiography is being performed.

(3) Measuring compliance. Compliance with the requirements of subparagraph (i) of paragraph (1) of this subdivision shall be determined when the equipment indicates that the beam axis is perpendicular to the plane of the image receptor and the provisions of paragraph (2) of this subdivision are met. Compliance shall be determined no sooner than 5 seconds after insertion of the image receptor.

(4) Operator initiated undersizing. The PBL system must be capable of operating such that, at the discretion of the operator, the size of the field may be made smaller than the size of the image receptor through stepless adjustment of the field size. Each dimension of the minimum field size at an SID of 100 cm must be equal to or less than 5 cm. Return to PBL function as described in paragraph (1) of this subdivision must occur automatically upon any change of image receptor size or SID.

(5) Override of PBL. A capability may be provided for overriding PBL in case of system failure and for servicing the system. This override may be for all SIDs and image receptor sizes. A key must be required for any override capability that is accessible to the operator. It must not be possible to remove the key while PBL is overridden. Each such key switch or key must be clearly and durably labeled as follows: "For X-Ray Field Limitation System Failure". The override capability is considered accessible to the operator if it is referenced in the operator's manual or in other material intended for the operator or if its location is such that the operator would consider it part of the operational controls.

(6) Disabling of PBL. A facility has the option to permanently functionally disable a PBL system. When this option is chosen, the standards for manual collimation apply.

(i) Source-skin distance. The minimum source-skin distance must not be less than 30 cm, except intraoral dental equipment regardless of clinical or veterinary use.

(j) Radiation from capacitor energy storage equipment. Radiation emitted from the x-ray tube must not exceed:

(1) an air kerma of 0.26 microGy (vice 0.03 mR exposure) in 1 minute at 5 cm from any accessible surface of the diagnostic source assembly, with the beam-limiting device fully open, the system fully charged, and the exposure switch, timer, or any discharge mechanism not activated; and

(2) an air kerma of 0.88 mGy (vice 100 mR exposure) in one hour at 100 cm from the x-ray source, with beam-limiting device fully open, when the system is discharged through the x-ray tube either manually or automatically by use of a discharge switch or deactivation of the input power. Compliance shall be determined by measurements of the maximum air kerma per discharge multiplied by the total number of discharges in 1 hour (duty cycle).

(k) Tube stands for portable x-ray systems. Except during veterinary field operations where it is impractical to do so, a tube stand or other mechanical support must be used for portable x-ray systems, so that the x-ray tube housing assembly need not be hand-held during an exposure.

(l) Conditions of use.

(1) The x-ray image receptor used as recording medium during the x-ray examination must show visual evidence of cut-off (beam delineation) on all four sides of the x- ray image. This applies to all x-ray units using manual collimation and where no positive means are used to contain the x-ray field to the size of the image receptor. The x-ray image receptor can be film or digital image receptors.

(2) Personnel monitoring must be required for all persons operating mobile or portable x-ray equipment, except hand-held dental x-ray units.

(3) No person shall be regularly employed to hold patients during exposures nor shall such duty be performed by an individual occupationally exposed to radiation in the course of that individual's other duties. When it is necessary to immobilize the patient, mechanical supporting or immobilizing devices should be used. Written safety procedures must provide the selection criteria for the holder and protocol to be followed during the patient holding procedure.

(4) If patients must be held by an individual, that individual must be instructed in personal radiation safety and must be protected with appropriate shielding devices such as protective gloves and a protective garment of at least 0.25 mm lead equivalent. No part of the holding individual's body shall be in the useful beam. The exposure of any individual used for holding patients must be monitored.

(5) For patients who have not passed the reproductive age, gonadal shielding of not less than 0.5 mm lead equivalent must be used during radiographic procedures in which the gonads are in the useful beam, except for cases in which this would interfere with the diagnostic procedure.

(6) Pregnant women and individuals under 18 years of age must not hold patients under any conditions.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.49. Specific Requirements for Dental Facilities

Open this section

(a) The following specific quality assurance requirements apply to a dental facility:

(1) If using a filmless system, maintain and operate PSP and DDR systems according to manufacturer specifications.

(2) The registrant must provide initial training and annual evaluations of x-ray operators to include but not limited to: positioning of the x-ray tube, image processing, operator location during x-ray exposure, source to skin distance, radiation protection, appropriate radiographic protocol and applicable regulatory requirements. Records of training and annual evaluations must be maintained for inspection by the Department.

(b) Warning label.

(1) On systems manufactured on or before June 10, 2006, the control panel containing the main power switch must bear the following warning statement, or the warning statement in paragraph (2) of this subdivision, legible and accessible to view: "WARNING: This x-ray unit may be dangerous to patient and operator unless safe exposure factors and operating instructions are observed."

(2) On systems manufactured after June 10, 2006, the control panel containing the main power switch must bear the warning statement, legible and accessible to view: "WARNING: This x-ray unit may be dangerous to patient and operator unless safe exposure factors, operating instructions and maintenance schedules are observed."

(c) Radiation exposure control. Means must be provided to initiate the radiation exposure by a deliberate action on the part of the operator, such as the depression of a switch. Radiation exposure must not be initiated without such an action.

(d) Exposure control location and operator protection. Except for units designed to be hand-held, the exposure control must allow the operator to be:

(1) behind a protective barrier at least 2 meters (6.5 feet) tall, or

(2) at least 2 meters (6.5 feet) from the tube housing assembly, outside the path of the useful x-ray beam, while making exposures.

(e) Administrative controls.

(1) Patient and image receptor holding devices must be used when the techniques permit.

(2) Except for units designed to be hand-held, the tube housing and position indicating device (PID) must not be hand-held during an exposure.

(f) Hand-held intraoral equipment. In addition to other requirements in this Article, the following applies specifically to hand-held devices:

(1) The hand-held x-ray system must be equipped with a backscatter shield of not less than 0.25 mm lead equivalent and 15.2 cm (6 inches) in diameter that is positioned as close as practicable to the distal end of the position indication device.

(2) The facility must maintain documentation that each operator has completed training as specified by the manufacturer.

(3) The facility must adopt and follow protocols provided by the manufacturer, and approved by the Department, regarding the safe operation of the device.

(4) When operating a hand-held intraoral dental radiographic unit, operators must wear a 0.25 mm lead equivalent apron.

(5) If the operator has difficulty in holding the device stationary during the exposure, the operator shall use a stand to immobilize the device.

(6) The registrant must secure the hand-held device from unauthorized removal or use.

(g) Beam-on indicators. The x-ray control must provide visual indication whenever x- rays are produced. In addition, for certified x-ray units, a signal audible to the operator must indicate that the exposure has terminated.

(h) Multiple tubes. Where two or more radiographic tubes are controlled by one exposure switch, the tube which has been selected must be clearly indicated prior to initiation of the exposure. Only the selected tube can be energized. This indication must be both on the x-ray control panel and at or near the tube housing assembly which has been selected.

(i) Mechanical support of tube head. The tube housing assembly supports must be adjusted such that the tube housing assembly will remain stable during an exposure unless tube housing movement is a designed function of the x-ray system.

(j) Battery charge indicator. On battery-powered generators, visual means must be provided on the control panel to indicate whether the battery is in a state of charge adequate for proper operation.

(k) Technique indicators.

(1) For x-ray equipment capable of displaying technique factors, the technique factors to be used during an exposure must be indicated before the exposure begins.

(2) The requirement of paragraph (1) of this subdivision may be met by permanent markings on equipment having fixed technique factors.

(l) Exposure reproducibility. For any specific combination of selected technique factors, the estimated coefficient of variation of the air kerma must be no greater than 0.05.

(m) Timers. Means must be provided to terminate the exposure at a preset time interval, a preset product of current and time, a preset number of pulses, or a preset radiation exposure to the image receptor.

(n) Kilovolt peak. At a minimum, the kVp must be accurate to within 10 percent on variable kVp units and within 20 percent on fixed kVp units.

(o) X-ray beam alignment.

(1) The useful x-ray beam must be limited to the area of clinical interest.

(2) Intraoral dental units.

(i) X-ray systems designed for use with an intraoral image receptor must be provided with means to limit the source-to-skin distance (SSD) to not less than 18 cm.

(ii) The x-ray field at the minimum SSD must be containable in a circle having a diameter of no more than 7 cm.

(3) Extraoral, panoramic and cephalometric units. X-ray systems designed for use with extraoral image receptors and when used with an extraoral image receptor, must be provided with means to limit the x-ray field in the plane of the image receptor so that such field does not exceed each dimension of the image receptor by more than 2 percent of the SID, when the axis of the x-ray beam is perpendicular to the plane of the image receptor. In addition, means must be provided to align the center of the x-ray field with the center of the image receptor to within 2 percent of the SID, or means must be provided to both size and align the x-ray field such that the x-ray field at the plane of the image receptor does not extend beyond any edge of the image receptor. These requirements may be met with:

(i) An assortment of removable, fixed-aperture, beam-limiting devices sufficient to meet the requirement for each combination of image receptor size and SID for which the unit is designed. Each such device must have clear and permanent markings to indicate the image receptor size and SID for which it is designed; or

(ii) A beam-limiting device having multiple fixed apertures sufficient to meet the requirement for each combination of image receptor size and SID for which the unit is designed. Permanent, clearly legible markings must indicate the image receptor size and SID for which each aperture is designed and must indicate which aperture is in position for use.

(p) Beam quality. The Half Value Layer (HVL) of the useful beam for a given x-ray tube potential must not be less than the values shown in Table 1 of 24 RCNY Health Code § 175.47(u). If it is necessary to determine such half-value layer at an x-ray tube potential which is not listed in Table 1, linear interpolation or extrapolation may be made.

(q) Conditions of use.

(1) The x-ray system must always be operated in such a manner that the useful beam at the patient's skin does not exceed the requirements of paragraph (2) of subdivision (o) of this section.

(2) The operator shall position the end of the position indicating device (PID) within 1 cm (0.4 in.) of the skin of the patient, if such device is routinely used in conducting dental radiography.

(3) Time-temperature techniques or automatic processing must be used to develop pre-operative diagnostic dental x-ray films. Processing techniques must be consistent with those recommended by the x-ray film manufacturer. Sight developing of dental radiographs is prohibited except for films taken during operative procedures.

(4) Dental x-ray exposure technique factors and dental processing conditions must yield entrance skin exposure (ESE) values for the bitewing x-ray projection that are identical to or do not exceed the maximum range of ESE values for dental "D" and "E" speed film designations as published in HHS document #FDA-85-8245 (August 1985) or superseding documents. With respect to maximum ESE values for digital image receptors (are deemed to be either Computed Radiography (CR) or Digital Image Receptors (DR)), digital image receptors shall be deemed to be equivalent to "E" speed film.

(r) Facilities possessing a Cone Beam Computed Tomography (CBCT) unit.

(1) Notwithstanding anything in this Article to the contrary, dental facilities possessing a CBCT unit must develop and maintain a written quality assurance program, including a written QA manual and a written radiation safety policy and procedures manual for all CBCT dental equipment possessed by the facility.

(i) For all dental CBCT units, the registrant must establish annual QA testing of x-ray parameters sufficient to maintain patient doses and image quality consistent over time. The annual tests will evaluate, at a minimum, collimation, filtration, patient dose, accuracy and reproducibility of x-ray techniques and the operational status of x-ray safety features.

(ii) For all CBCT units, the QA tests must follow the manufacturer's recommended tests and frequency and utilize the manufacturer's QA phantom. The QA test results will be retained for review by the Department for 5 years, the facility must establish QA testing that includes, at a minimum, the manufacturer's recommended QA tests plus the additional QA tests described in subparagraph (iii) of this subdivision.

(iii) Semi-annual QA tests to determine image noise, image uniformity, reconstructed image measurement accuracy, high contrast spatial resolution of the CBCT unit.

(iv) Dental facilities possessing a CBCT unit must use a medical physicist who is a QMP in performing its QA activities.

(2) Dental facilities possessing CBCT equipment must annually determine the patient radiation dose (using direct measurement or indirect means to estimate dose) for the most common CBCT scan used at the facility as conducted by a QMP.

(3) Dental facilities possessing CBCT equipment must conduct annual QA tests to measure reproducibility of imaging parameters (kVp, exposure time and dimensions of the scan beam), reproducibility of exposure per the most common scan and beam filtration (HVL).

(4) Conditions of operation for the CBCT unit.

(i) Facilities possessing a CBCT unit must adhere to the requirements of sections 24 RCNY Health Code §§ 175.46 and 175.47 regarding the shielding requirements and operator protection for all CBCT units possessed by the dental facility.

(ii) All operators of the CBCT must undergo training on the proper operation of the CBCT units and documentation of this training must be retained by the dental facility for review by the Department until after the next scheduled inspection is completed by the Department.

(iii) All operators must be able to communicate with and visually observe the patient during the CBCT examination from the operator's protected position.

(iv) CBCT patient exams will not be conducted solely for cosmetic purposes with no diagnostic value to the patient.

(v) The logbook for CBCT exams must contain all relevant diagnostic examination information, including but not limited to, x-ray technique, scan time, anatomical exam site and reason for examination.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.50. Podiatric Radiography

Open this section

(a) Equipment. Collimating devices capable of restricting the useful beam to the area of clinical interest must be used. The x-ray films or image receptor used as the recording medium during the x-ray examination must show substantial evidence of cut-off (beam delineation). A device must be provided which terminates the exposure after a preset time interval or exposure. The exposure switch must be of the dead-man type and where protective barriers are required must be so arranged that it cannot be operated outside the shielded area.

(b) Each installation must be arranged so that the operator can stand at least 2 meters (6.5 feet) from the patient, the x-ray tube and the useful beam during exposure. A protective barrier must be provided when the operator cannot stand at least 2 meters (6.5 feet) away from the patient, the x-ray tube and the useful beam during exposures.

(c) No person shall hold film during the exposure. Only persons required for the radiographic procedure must be in the radiographic room during exposure.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.51. Veterinary Radiography, Dental and Fluoroscopy

Open this section

(a) Fixed radiographic installations: equipment.

(1) Collimating devices capable of restricting the useful beam to the area of clinical interest must be used.

(2) The x-ray films or image receptor used as the recording medium during the x-ray examination must show substantial evidence of cut-off (beam delineation).

(3) A device must be provided which terminates the exposure after a preset time interval or exposure. The exposure switch must be of the dead-man type and must be so arranged that it cannot be operated outside a shielded area.

(b) Portable or mobile radiographic installations: equipment.

(1) Collimating devices capable of restricting the useful beam to the area of clinical interest must be used.

(2) The x-ray film or image receptor used as the recording medium during the x-ray examination must show evidence of cut-off (beam delineation).

(3) A device must be provided which terminates the exposure after a preset time interval or exposure.

(4) A dead-man type of exposure switch must be provided with a cord of sufficient length so that the operator can stand at least 2 meters (6.5 feet) from the animal patient, the x-ray tube and out of the useful beam.

(c) Veterinary dental x-ray units. The requirements of 24 RCNY Health Code § 175.49(a) through (r) applies to veterinary dental units with the exception of the ESE requirements of 24 RCNY Health Code § 175.49(q)(3). For hand held dental x-ray units, the same conditions of operation and restrictions on hand held x-ray units (as described in 24 RCNY Health Code § 175.47(j)) apply.

(d) Fluoroscopic installations: equipment.

(1) Equipment must be so constructed that the entire cross-section of the useful beam is always intercepted by a primary protective barrier regardless of the panel-screen distance. For conventional fluoroscopes, this requirement may be assumed to have been met if, when the collimating system is opened to its fullest extent, an unilluminated margin is left on all edges of the fluorescent screen regardless of the position of the screen during use. Equipment with an image receptor must be so constructed that the useful beam cannot exceed the limits of the input phosphor.

(2) The exposure must automatically terminate when the barrier is removed from the useful beam.

(3) The fluoroscopic exposure switch must be of the dead-man type.

(4) Provision must be made to intercept the scattered x-rays from the undersurface of the tabletop and other structures under the table.

(5) The source-panel or source-tabletop distance must always be at least 30 cm (12 in.) and is recommended to be not less than 38 cm (15 in.).

(e) Mobile fluoroscopic equipment must meet the following additional requirements:

(1) In the absence of a tabletop, a cone or spacer frame must limit the source- to-skin distance to not less than 30 cm (12 in.).

(2) Image intensification must always be provided.

(3) It must not be possible to operate a machine unless the useful beam is intercepted by the image receptor.

(f) Conditions for operation of equipment.

(1) Only persons required for the x-ray procedure shall be in the x-ray room during exposures.

(2) When an animal patient must be held in position during exposures, mechanical supporting or restraining devices must be used.

(3) Animal patients or films or image receptors must be held by an individual only under extreme conditions when clinically necessary. Such individuals must wear protective gloves having at least 0.25 mm lead equivalent, a protective garment of at least 0.25 mm lead equivalent, and must keep all parts of their body out of the useful beam.

(4) The exposure of any individual used for holding animals must be monitored.

(5) Pregnant women and individuals under 18 years of age must not hold animal patients or films or image receptors under any conditions.

(6) Protective garments of at least 0.25 mm lead equivalent must be available and must be worn by the fluoroscopist during every fluoroscopy examination.

(Added City Record 4/24/2019, eff. 5/24/2019)

§ 175.52. Dual-Energy X-ray Absorptiometry (DXA) (Bone Densitometry)

Open this section

(a) Dual-energy X-ray Absorptiometry (DXA) systems must be:

(1) certified by the manufacturer pursuant to the Medical Device Act and Subchapter C - Electronic Product Radiation Control of Chapter V of the Federal Food, Drug and Cosmetic Act;

(2) registered in accordance with this Article; and

(3) at a minimum, maintained and operated in accordance with the manufacturer's specifications.

(b) Operator requirements. Operators of the bone densitometer must either be a professional practitioner or a Licensed Radiologic Technologist. Operators must complete training specific to patient positioning and the operation of the DXA system.

(c) During the operation of any DXA system, in the absence of a survey performed by or under the supervision of a QMP determining the minimum distance the operator may be from the patient and radiation source, the operator, ancillary personnel, and members of the general public must be positioned at least 2 meters from the patient and DXA system during the examination.

(d) Quality assurance. The facility must follow the manufacturer's quality assurance specifications as to required quality control tests, including their frequency.

(Added City Record 4/24/2019, eff. 5/24/2019)