24 RCNY New York City Health Code part 8 of 13
§ 165.41 to § 173.03: 35 sections.
§ 165.41. General Requirements for Pools
This section has 1 picture (figures, equations, or tables drawn as images) that BetaNYC's copy does not show. Read 24 RCNY Health Code § 165.41 at American Legal Publishing.
(a) General. All bathing establishments with pools shall be designed and constructed in accordance with the requirements contained in this Code. All bathing establishments with pools shall be located at a site conducive to good operation, maintenance, and public safety and free from contamination. The site shall have sufficient drainage and be separated from environmentally sensitive areas (for example, subsurface sewage disposal systems, open bodies of freshwater, groundwater wells).
(b) Structural stability. The designing architect or engineer shall certify the structural stability and safety of the bathing establishment. All bathing establishments shall be designed and constructed to withstand all anticipated loading for both full and empty conditions, and hydrostatic and earth pressures involved in each case. The strength of the assembled and installed components and accessories to be used in and around the pools should be such that no structural failure of any component part shall cause the failure of any other component part.
(c) Construction material finishes.
(1) Materials. Pools shall be constructed of materials which are inert, stable, nontoxic, watertight and enduring. Sand or earth bottoms or unlined wooden tubs are prohibited. The materials of components and accessories used in and around the pools shall be compatible with human occupancy and the environment in which they are installed. Materials shall be capable of fulfilling the design, installation, and intended use requirements.
(2) Finish. The pool bottom and sides shall be white or a light color with a smooth and easily cleanable surface.
(3) Corners. All corners formed by intersection of pool walls and bottom shall be rounded.
(d) Accessibility.
(1) Entrance. For pools receiving construction authorization from the department after the effective date of this Article, entrance to the pool area shall be at a point adjacent to the shallow end of the pool.
(2) An emergency exit from the pool room shall be provided. All exits should be clearly marked.
(e) Equipment. All equipment used or proposed for use in pools shall be tested and listed by N.S.F. or another testing laboratory under standards promulgated by N.S.F. Equipment that is experimental or not N.S.F. approved shall be submitted to the Department for review. The experimental equipment shall be tested as follows:
(1) Use-tested in New York or another state in at least 10 pools of comparable design for a period of at least 60 days, with engineering reports on results of use submitted; or
(2) Pilot-plant testing of at least 90 days, with formal submission of an operational report prepared by the design engineer or architect; or
(3) A combination of use and testing or a trial use period approved by the Department and the New York State Commissioner of Health.
(f) Size and shape. Dimensional limits are not specified for the length, width, or shape of pools. The size and shape shall be selected based on competitive requirements, bather demand, and space available for a particular establishment. The shape of any pool shall be such that the circulation of pool water and control of bathers' safety are not impaired. There shall be no underwater or overhead projections or obstructions which would endanger patron safety or interfere with pool operation.
(g) Minimum water depth. The minimum depth of water in the pool shall be three feet except for wading pools and wave pools.
(h) Bottom slope. The bottom of the pool shall slope downward toward the main drains. The slope in shallow areas (depths less than 5') shall not exceed one foot (1') vertical in twelve feet (12') horizontal. In portions of the pool with depth greater than five feet, the slope shall not be steeper than one foot in three feet.
(i) Pool walls. The walls of a pool shall be either:
(1) Vertical for a distance of at least six feet (6'); or
(2) Vertical for a distance of at least three feet (3') below the water level; below which the wall may be curved to the bottom with a radius not greater than the difference between the depth at that point and three feet (3'); provided that vertical is interpreted to permit slopes not greater than one foot (1') horizontal for each five feet (5') of depth of sidewall (11 degrees from vertical).
(j) Safety ledges. Ledges shall not extend into the pool unless they are essential for support of the upper wall construction.
(k) Decks and walkways.
(1) General. A continuous deck at least five feet (5') wide shall extend completely around the pool. For spa and wading pools, two contiguous sides of decking equal to fifty percent (50%) or more of the perimeter shall be provided. The deck shall be of a uniform, easily cleaned, impervious material with a slip-resistant surface.
(A) Deck capacity. Additional deck space beyond the required five feet wide clear walkway may be constructed based on a minimum ratio of fifty square feet (50 ft 2 ) of pool deck area per bather.
(B) Where diving boards, slides, or any other deck equipment are installed at the pool, a clear deck of not less than five feet of constructed deck shall be provided behind the diving boards, slides, lifeguard chair or other deck equipment.
(2) Deck covering. Porous, non-fibrous deck covering which contains a label indicating it complies with the N.S.F. or other material approved by the department may be used for deck covering. An approved material shall meet the following criteria:
(A) The covering shall allow drainage so that the covering and the deck underneath it do not remain wet or retain moisture.
(B) The covering is inert and will not support bacterial growth.
(C) The covering provides a slip-resistant surface.
(D) The covering is durable and cleanable.
(3) Slope. The deck shall be sloped at least one-fourth inch per foot (1/4 in/ft) to deck drains or grades.
(4) Drainage. Deck drains, when used, shall be spaced and arranged so that not more than four hundred square feet (400 ft 2 ) of area is tributary to each drain, and drains shall not be spaced more than twenty-five feet (25 ft) apart. There shall be no direct connection between the pool deck drains and the pool gutter or recirculation system. The deck of outdoor pools shall be sloped away from the pool or to the deck drains to prevent surface runoff from entering the pool.
(5) Roll-out and deck level gutters. If the pool is equipped with deck level gutters, not more than five feet of deck shall be sloped toward the gutters.
(6) Hose bibbs. At least one hose bibb shall be provided to facilitate flushing of the deck area and each bibb shall be provided with an anti-siphonage device.
(7) Rinse showers. Adjacent recreational areas shall be separated from the bathing area by a suitable fence or barrier. If bathers are permitted free access between the deck and an adjacent recreational area without having to pass through a bathhouse or bather preparation facilities, a rinse shower area shall be installed so that bathers shall pass through the rinse shower area when going from the recreational area to the deck. Minimum requirements for a rinse shower shall include:
(A) water for the rinse shower(s),
(B) have sufficient drainage so that there is no standing water,
(C) a foot surface that is impervious and slip-resistant.
(l) Pool enclosures. All pools shall be protected by a fence, wall, building, or other solid barrier, or any combination thereof. A wall of a building may serve as part of the enclosure, provided that there is no direct access from the wall to the pool. Pools located on a roof, where there is no access to the roof except through doors where access can be prevented when the pool is unsupervised, do not require additional enclosure. All pools shall be provided with an enclosure which shall comply with the following:
(1) No external handholds or footholds.
(2) Materials which are durable.
(3) At least six feet (6') in height, except for wading pools at four foot (4') minimum (see 24 RCNY Health Code § 165.51).
(4) Have a maximum vertical clearance above grade of two inches (2").
(5) The entrance into the pool enclosure shall be equipped with a door or gate that is self-closing and has a positive self-latching closure mechanism at least forty inches (40") above grade. Doors and gates at all entrances shall be equipped with hardware that permits secure locking of the entrance and prevents access when the pool is not supervised.
(6) Where a chain-link fence is provided, the openings between links shall not exceed 2 3/8 inches and chain link twists shall extend above the upper horizontal bar. The enclosure shall have railings and posts within the enclosure, which shall be capable of resisting a minimum lateral load of one hundred fifty pounds (150 lb) applied midway between posts and at top of posts, respectively. Enclosures, fence material or fabric shall be capable of withstanding a concentrated lateral load of fifty pounds (50 lb) applied anywhere between supports on an area twelve square inches (12 in 2 ), without failure or permanent deformation.
(7) Where a picket-type fence is provided, space between pickets shall not exceed 4 inches and pickets shall extend above the upper horizontal bar.
(m) Pool capacities and patron loading. The maximum permissible number of bathers allowed in the pool at one time is as follows:
(1) Pools (except spa and wading pools): Twenty-five square feet (25 ft 2 ) of water surface area shall be provided for each patron.
(2) Diving area: Three hundred square feet (300 ft 2 ) of pool water surface area shall be reserved around each diving board or diving platform, and this area shall not be included in computing the permissible patron use.
(3) Spa pools: Ten square feet (10 ft 2 ) of pool water surface area shall be provided for each patron.
(4) Wading pools: Fifteen square feet (15 ft 2 ) of pool water surface area shall be provided for each patron.
(n) Spectator areas and visitor galleries. There shall be an effective separation between spectator areas and bather areas so as to prevent contamination of the pool. Galleries for spectators shall not overhang any portion of the pool surface. The floor and foot rail of the gallery shall be of tight construction to prevent dirt from being tracked into the pool.
(o) Depth markings and safety lines.
(1) Depth markings. Depth markings shall be numerical with numbers of four inch (4") minimum height, followed by the words "feet deep" or "foot depth", and with colors contrasting with the background. Depth of water shall be plainly marked at or above the water surface on the vertical pool wall and on the edge of the deck next to the pool. Depth markers shall indicate the actual pool depth. Water depth shall be measured at a point three feet (3') from the pool wall. Depth markers shall be spaced at not more than twenty-five foot (25') intervals along the pool perimeter. Where depth markings cannot be placed on the vertical walls above the water level, other means shall be used so that the markings will be plainly visible to persons in the pool. Markings shall be on both sides and ends of the pool placed at the following locations:
(A) At the points of maximum and minimum depth and at all points of change of slope.
(B) At break between the deep and shallow portions.
(C) At intermediate two foot (2') increments of depth.
(2) Depth markers of irregularly shaped pools. Depth markers of irregularly shaped pools shall specify depth at intervals of 25 feet measured along the perimeter of the pool.
(3) Safety lines. The boundary line between the shallow and deep areas where it exists, shall be marked at the five foot depth with a four inch stripe of contrasting color on the floor and walls of the pool and by a safety rope and floats equipped with float keepers. Where there is no break in slope the boundary shall be set at the five foot (5') depth, where it is ten feet (10') or more from the nearest end of the pool. Ledges and step edges shall also be marked with a four inch (4") stripe of contrasting color, two inches (2") on the tread and two inches (2") on the riser.
(p) Diving area.
(1) The minimum dimensions of the swimming pool and appurtenances in the diving area shall conform to Table 3. The minimum dimensions for diving portion of swimming pools designed for competitive diving, may upon application to, and approval by, the department, utilize nationally recognized competitive design standards. For diving boards in excess of 3 meters in height over water, the design criteria, including pool dimensions shall be adjusted in accordance with good engineering practice.
(2) Headroom. There shall be a completely unobstructed clear distance of sixteen feet (16') above the diving board, measured from the center of the front end of the board. This area shall extend at least eight feet (8') behind, eight feet to each side, and sixteen feet (16') ahead of the measuring point.
(3) Diving boards and platforms. Diving boards and platforms in excess of three meters in height shall be designed and constructed or selected such that they are adequate to sustain expected static and dynamic loading with appropriate design safety factors.
(4) Steps and guardrails for diving boards. Supports, platforms and steps for diving boards shall be of adequate design and construction and of sufficient structural strength with appropriate design safety factors to safely carry the maximum anticipated loads. Steps shall be of corrosion-resistant material, easily cleanable and of nonslip design. Handrails shall be provided at all steps and ladders leading to diving boards one meter or more above the water. The guardrails shall be thirty inches (30") high, extending at least to the edge of the water.
Table 3. Minimum Dimensions for Diving Portion of Swimming Pool
Note: Minimum depth of five feet shall be maintained when a wall terminates at the pool area opposite diving boards. Otherwise, the specified shallow area floor slope may be used to shallow end.
Minimum Dimensions Max. board height over water Max. diving board length D L(1) L(2) Pool width 26" (2/3 meter) 10' 8'-6" 2'-6" 10'-0" 20'-0" 30" (3/4 meter) 12' 9'-0" 3'-0" 10'-0" 20'-0" 1 meter 16' 11'-0" 4'-0" 20'-0" 20'-0" 3 meters 16' 12'-0" 6'-0" 20'-0" 24'-0"
Board placement shall be in compliance with the following. For multiple-board installations, minimum pool widths shall be increased accordingly.
1 meter or less – Board to pool side 10'0" 3 meters – Board to pool side 12'0" Distance between adjacent boards 10'0"
(q) Deck slides. All deck slides which may be installed at a swimming pool shall be labeled to indicate compliance with the requirements of the U.S. Consumer Product Safety Commission or other generally acceptable standard that provides equivalent and adequate safety. The bottom of any slide shall discharge into a minimum water depth of four feet.
(r) Rolling bulkheads. Rolling bulkheads which may be provided at a pool, shall be equipped with traction wheels running on the pool floor or alternatively in the overflow gutter. The design shall be such that the patrons cannot be entrapped under the bulkhead.
(s) Starting blocks. Starting blocks when provided, shall be designed according to recognized competitive design standards. Starting blocks shall be installed over a minimum water depth of six feet (6').
(t) Ladders, recessed steps, stairs and handrails. Except in a wading pool, physical-therapy pool, wave pool, white-water slide or movable-bottom pool, steps or ladders shall be provided to serve the shallow and deep portion of the pool, and if the pool is over thirty feet wide, such steps or ladders shall be installed on each end and on opposite sides. Stairs, ladders, and recessed steps shall be located so as not to interfere with racing lanes or with diving. If recessed steps are used, at least one additional non-recessed stairway or one conventional ladder shall be provided.
(1) Ladders. Pool ladders shall be corrosion-resistant and shall be equipped with nonslip treads. All ladders shall be so designed as to provide a handhold and shall be rigidly installed. There shall be a clearance of not more than six inches (6") nor less than three inches (3") between any ladder and the pool wall.
(2) Recessed steps. Recessed steps shall be readily cleanable and shall be arranged to drain into the pool to prevent the accumulation of dirt. Recessed steps shall have a minimum breadth of five inches (5") and a minimum width of fourteen inches (14").
(3) Stairs. Where stairs are provided they shall be located diagonally in a corner of the pool or be recessed. They shall be equipped with a handrail. Stairs shall be of nonslip design, have a minimum tread of twelve inches (12") and a maximum rise of ten inches (10").
(4) Handrails. Where ladders, recessed steps and stairs are provided within the pool, there shall be a handrail at the top of each side thereof extending over the coping or edge of the deck.
(u) Safety and warning signs.
(1) "No diving" markers. "No diving" markers at least four inches (4") high shall be located at not more than twenty-five foot (25') intervals around the pool perimeter, where the water depth is less than eight feet deep.
(2) Warning signs. A sign or signs shall be securely posted in a conspicuous place or places in the pool area and bather preparation facility and shall provide the following information:
(A) Maximum number of persons permitted in pool at any time.
(B) Maximum number of persons permitted on deck at any time.
(C) Maximum number of persons permitted in the pool area.
(D) The hours that pool is open.
(E) The hours that pool use is prohibited.
(F) "No person having any contagious disease or infectious condition such as sores or inflamed eyes, a cold, nasal or ear discharge, cuts, boils or other evident skin or other bodily infection shall enter the pool."
(G) "Urinating, expectorating or blowing the nose, or allowing human waste in any pool is prohibited."
(H) "Persons not dressed for bathing shall not enter upon walks immediately adjacent to pools, and bathers shall not enter places provided for spectators."
(I) "No person under the influence of alcohol or exhibiting erratic behavior shall enter the pool or the pool deck."
(J) "Emergency telephone number for police, fire, and hospital is 911."
(K) "Prolonged or repetitive breath-holding can be deadly. No intentional hyperventilation or underwater competitive breath-holding."
(i) The Department may require that the sign include a pictogram designed by the Department that conveys these dangers.
(3) Deck slides. In pools equipped with a deck slide, the warning sign shall include the words: "No sliding in water less than four feet deep and no sliding except in a feet-first position."
(4) Starting platforms and blocks. In pools equipped with starting blocks, the warning sign shall include: "Starting blocks shall not be used for any purpose other than competitive swimming or swimmer-training activities."
(5) White-water slides: In facilities with white water slides, warnings shall be posted on a sign at the entrance to the slide tower containing the following:
(A) "Keep your hands inside of the flume."
(B) "No standing, kneeling, rotating, chain-riding, or stopping in flumes."
(C) "Sliding shall be performed only in a feet-first position."
(6) Warm water spas: In addition to the contents of paragraph (2), the following warning sign, with an area of at least three square feet, preceded by the word "CAUTION" shall be conspicuously posted in the vicinity of the pool at eye level:
(A) "Elderly persons and persons suffering from heart disease, diabetes, high or low blood pressure, shall not use the spa pool without medical consultation."
(B) "Unsupervised use by children is prohibited."
(C) "Do not use the spa pool while under the influence of alcohol. Persons using medications such as anticoagulants, antihistamines, vasoconstrictors, vasodilators, stimulants, hypnotics, narcotics or tranquilizers should not use the spa pool without medical consultation."
(D) "Do not use the spa pool if you are alone and the spa pool is unattended by pool staff."
(E) "Observe a reasonable time limit (e.g., 15 minutes), then shower, cool down and, if you wish, return for another brief stay. Long exposure may result in nausea, dizziness or fainting."
(F) "Emergency help can be obtained by using the telephone – dial 911."
(7) Nothing in 24 RCNY Health Code § 165.41(u) prevents the operator from posting any additional sign or adding language to required signs alerting bathers to activities that are limited or prohibited under the operator's safety plan.
(v) Safety equipment. The pool shall provide the safety equipment as required by 24 RCNY Health Code § 165.17.
(w) First aid room. Pools with a surface area in excess of four thousand square feet (4,000 ft 2 ) shall have a readily accessible room or area designated and equipped for emergency care.
§ 165.42. General Requirements for Spray Grounds
(a) General. All bathing establishments with a spray ground shall be designed and constructed in accordance with the requirements contained in this Code. All spray grounds shall be located at a site free from contamination and conducive to good operation, maintenance, and public safety. The designing architect or engineer shall certify the structural stability and safety of the spray grounds. The strength of the assembled and installed components and accessories to be used in and around the pools spray grounds should be such that no structural failure of any component part shall cause the failure of any other component part. All spray grounds shall further comply with all of the following provisions:
(b) Construction materials and finishes.
(1) Construction materials. Spray pads shall be constructed of materials which are inert, stable, nontoxic, watertight and enduring. Sand or earth bottoms are prohibited.
(2) Finish. Spray pad surface must be slip resistant and easily cleanable surface.
(c) Spray Pad.
(1) Slope. The spray pad shall be sloped to drain. The slope shall be sufficient to prevent water collecting on the pad.
(2) Drainage. The size, number and locations of the spray pad drains shall be determined and specified so as to assure water does not accumulate on the spray pads. Flow through the drains to the spray pad treatment tank shall be under gravity; direct suction outlets from the spray pad are prohibited.
(3) Valves and Piping. Valves and piping shall be provided in the spray pad drainage system to allow for discharging spray pad water to waste prior to returning to the spray pad treatment tank.
(4) Grating. Openings in the grates covering the drains shall not be over one-half inch wide. Gratings shall not be removable without the use of tools.
(d) Decks.
(1) A continuous deck at least five feet (5') wide shall extend completely around the entire spray pad perimeter. The deck shall be of a uniform, easily cleaned, impervious material with a slip-resistant surface.
(2) Slope. The deck shall be sloped at least one-fourth inch per foot (1/4 in/ft) to deck drains or grades.
(3) Drainage. Deck drains, when used, shall be spaced and arranged so that not more than four hundred square feet (400 ft 2 ) of area is tributary to each drain, and drains shall not be spaced more than twenty-five feet (25 ft) apart. There shall be no direct connection between the spray pad deck drains and the sanitary sewer system or treatment tank, or between the treatment tank and recirculation system. The deck for outdoor spray ground shall be sloped away from the spray pad or to the deck drains to prevent surface runoff from entering the spray pad.
(4) Carpeting. Carpeting shall not be permitted on the spray pad or desk.
(5) Hose bibbs. At least one hose bibb shall be provided to facilitate flushing of the spray pad and deck areas and each bibb shall be provided with an anti-siphon device.
(e) Spray Features. Spray features should be designed and installed so as not to pose a tripping hazard, a hazard to due water velocity from the spray features, or other possible safety hazards.
(f) Foot Showers. Showers shall be provided at the entry to the spray pad to allow for rinsing debris from patrons' feet prior to entering the spray pad, except such showers are not required at indoor spray grounds or those within the enclosure of an aquatic amusement park. The use of foot baths is prohibited. Wastewater from the foot showers shall be discharged to an approved waste disposal system to prevent standing water on the ground surface, and/or contamination of spray ground and adjacent areas. The foot shower area shall be free of puddle water.
(g) Spray Ground Enclosures. All spray grounds shall be protected by a fence, wall, building, other solid barrier, or any combination thereof. A wall of a building may serve as part of the enclosure, provided that there is no direct access from the wall to the spray ground. A spray ground located on a roof, where there is no access to the roof except through doors where access can be prevented when the spray ground is unsupervised, does not require additional enclosure. All spray grounds shall be provided with an enclosure which shall have the following characteristics:
(1) No external handholds or footholds.
(2) Made of materials which are durable.
(3) At least four feet (4') in height,
(4) Maximum vertical clearance above grade of two inches (2").
(5) The entrance into the spray ground enclosure shall be equipped with a door or gate that is self-closing and has a positive self-latching closure mechanism at least forty inches (40") above grade. Doors and gates at all entrances shall be equipped with hardware that permits secure locking of the entrance and prevents access when the spray ground is not supervised.
(6) Where a chain-link fence is provided, the openings between links shall not exceed 2 3/8 inches and chain link twists shall extend above the upper horizontal bar. The enclosure shall have railings and posts within the enclosure, which shall be capable of resisting a minimum lateral load of one hundred fifty pounds (150 lb) applied midway between posts and at top of posts, respectively. Enclosures, fence material or fabric shall be capable of withstanding a concentrated lateral load of fifty pounds (50 lb) applied anywhere between supports on an area twelve square inches (12 in 2 ), without failure or permanent deformation.
(7) Where a picket-type fence is provided, space between pickets shall not exceed 4 inches and pickets shall extend above the upper horizontal bar.
(h) Warning Signs. A durable plate bearing the following wording in 24-point type (letters 0.25 inches in height) or more permanently marked thereon in colors contrasting with the background, shall be prominently affixed at spray pad or enclosure/entrance and in the bathhouse or bather preparation facilities at eye level containing the following:
(1) The hours that spray pad is open.
(2) The hours that spray pad use is prohibited.
(3) Individuals with diarrhea shall not use the spray pad.
(4) Spray features use recirculated water – do not drink.
(5) Children who are not toilet trained must wear a swim diaper covered by rubber pants.
(6) No animals allowed on or near spray pad.
(7) Pollution of the spray pad area is prohibited. Urinating, discharge of fecal matter, expectorating or nose blowing in any spray pad area is prohibited.
§ 165.43. Water Supply, Waste Water, and Sewer Connections
(a) Water supply.
(1) The source and quality of the water supplied to the pool and/or spray ground and all plumbing fixtures, including drinking fountains, lavatories and showers, shall be obtained from the municipal water supply or a source of potable water pursuant to 24 RCNY Health Code § 141.01.
(2) Cross-connection control. The potable water supply shall be protected against inter-connection or cross-connection to any potential source of contamination, including but not limited to backflow and back-siphonage. Water introduced into the pool and/or spray pad, either directly or to the recirculation system, shall be supplied through an air gap of at least 6 inches or two times the pipe diameter, whichever is greater. In pools and/or spray pad where it is not possible to provide an air gap, the pool and/or spray water shall be protected by an approved backflow prevention device.
(3) Drinking water fountains. Drinking fountains shall be of a slanting jet-type with a surrounding guard and nonsubmersible opening. They shall be accessible by patrons at the pool and be supplied with adequate water pressure.
(4) Fill spout. When a fill spout is used to introduce water into the pool, it shall be covered so as not to create a hazard to the patrons. The open end of the fill spout shall have no sharp edges, shall not protrude more than two inches beyond the edge of the pool and shall be at least six inches above the deck level. The fill spout shall be located under the diving board when the pool is equipped with a diving board.
(b) Waste water disposal.
(1) The sanitary sewer system shall have sufficient capacity to serve the facility, including the bathhouse, locker rooms and related accommodations. The building drains and sewer system shall have adequate capacity to carry filter backwash flows without surcharging or flooding. Sanitary sewage and pool and/or spray pad waste water shall be discharged to the municipal sanitary sewer system whenever possible. The establishment shall obtain the waste water discharge permit or approval from the appropriate regulatory agency (for example, the New York City Department of Environmental Protection) prior to discharge. When no such sewer is available, the connection shall be made to a suitable private subsurface disposal system or other system approved by the department and such agencies having jurisdiction.
(2) The pool and/or spray pad waste water shall be discharged to the sanitary sewer system through an air gap of at least six inches (6") or two times the pipe diameter, whichever is greater, so as to preclude the possibility of backup of sewage or waste water into the pool and/or spray pad piping system.
(c) Potable water treatment and sewage treatment facilities. Plans for any potable water treatment or sewage treatment facilities to be constructed on-site at the bathing establishment shall be submitted for approval by the department prior to construction of such facilities.
§ 165.45. Water Treatment System
This section has 1 picture (figures, equations, or tables drawn as images) that BetaNYC's copy does not show. Read 24 RCNY Health Code § 165.45 at American Legal Publishing.
(a) General. A water treatment system consisting of pumps, piping, filters, water conditioning and disinfection equipment, and other accessory equipment, shall be provided which will clarify, chemically balance and disinfect the pool water and/or spray pad water. The system shall be designed for a recirculation flow rate that will result in a turnover period in each pool and/or spray ground not exceeding those specified below. Construction shall comply with all other provisions of this Code regarding water and waste water.
(1) Pools. Each pool shall have a separate water treatment system. Pools with an approved design rate of less than those specified below shall be operated at the design rate. Construction of fill and draw pools is prohibited.
Types of Pool Turnover Period Shall Not Exceed Swimming Pool 6 hours Physical-Therapy Pool 4 hours Moveable Bottom Pool 4 hours Wading Pool 2 hours Wave Pool 2 hours White Water Slides 1 hour Spa Pool 30 minutes; and shall be capable of returning the spa water to a turbidity of less than 0.50 N.T.U. (Nephelometric Turbidity Units) measured within four hours following the peak bather load.
Pools constructed prior to March 31, 1973 may have an eight-hour turnover rate.
(2) Spray Grounds. All water provided to the spray pad shall be treated with ultraviolet light as specified in 24 RCNY Health Code § 165.45(l)(9) during spray pad operation. The spray pad treatment system shall comply with the following requirements:
(A) The water from the spray pad treatment system can only be combined/circulated with water from other pool(s) if:
(1) All the water from the spray pad is treated by ultraviolet (uv) light disinfection prior to combining/circulating with water from the other pool(s) or;
(2) UV light disinfection are provided to treat all of the water in the other pool(s). The larger flow rate resulting from the two calculations below shall be the minimum flow rate used for the treatment system design. All recirculated water must pass through both the ultraviolet light unit(s) and filters. The minimum flow rate through the treatment system shall be calculated using the two methods described below:
(i) Minimum flow rate (For ultraviolet disinfection):
Q: Minimum flow rate through the ultraviolet disinfection/filtration system (in gallons per minute) V: Pool volume (in gallons). ln(V): Natural log of the volume. 14.8-ln(V): Number of turnovers
(ii) Minimum filtration flow rate (for combined pool/spray pad system): The minimum filtration rate for a pool that shares water with a spray pad is specified in 24 RCNY Health Code § 165.45(a)(2)(C)(iii). The minimum filtration flow rate shall be at least the sum of the flow rate for the pool type specified in 24 RCNY Health Code § 165.45(a)(1) and one third of the spray feature flow rate.
(B) When water supplying the spray features is removed from the spray pad treatment tank by a pump separate from the filtration/recirculation pump system, the ratio of the flow rate of water supplied to the spray features directly from the treatment tank must not exceed 3 times the design filtered water flow rate.
(C) Turnover Rate.
(i) When water is supplied to the spray features by a pump which removes water directly from the spray pad treatment tank independent from the spray pad treatment tank filter pump, the turnover rate for filtration shall be determined by the feature flow rate. The filtration flow rate for the spray pad treatment tank must be at least one-third of the design spray feature flow rate.
(ii) When all of the water supplied to the spray features is filtered upon removal from the spray pad treatment tank before being supplied to the spray features, a reduced pumping rate for filtration/treatment of the spray pad treatment tank water can be used when the spray features are not in operation. However, a minimum 4-hour turnover rate shall be provided.
(iii) The minimum flow rate through the filtration system for combined pool/spray pad systems shall be equal to or greater than the sum of the flow rate for the specific type pool as required by 24 RCNY Health Code § 165.45(a)(1), plus one third of the spray feature flow rate.
(b) Equipment and storage area. All the pumps, filters, chemical feeders and other mechanical equipment and chemicals shall be secured and protected by an appropriate enclosure or room, separate and apart from the pool. The size of the equipment room shall provide working space to perform routine operations. Clearance shall be provided for all equipment as prescribed by the manufacturers to allow normal maintenance operation and removal without disturbing other piping or equipment. Operating instructions and a schematic drawing for all equipment shall be provided in the equipment enclosure room. Adequate storage area shall be provided for chemicals and supplementary equipment. A dry above ground storage area shall be provided for facilities using calcium hypochlorite as a disinfectant. Equipment rooms shall not be used for storage of chemicals emitting corrosive fumes or for storage of other items to the extent that entrance to the room for inspection or operation of the equipment is impaired.
(c) Hydraulics and piping system.
(1) Materials. The recirculating piping and fittings shall be of nontoxic material, resistant to corrosion, and able to withstand operating pressures. Acceptable materials for recirculation systems are polyvinylchloride (PVC), copper, stainless steel, aluminum, cast iron or other material suitable for water supply applications.
(2) Size. All pipes, fittings and valves of the recirculation system shall be designed to reduce friction losses to a minimum and to carry the required quantity of water at a maximum velocity not to exceed six feet per second (6 ft/s) under suction, ten feet per second (10 ft/s) under pressure and three feet per second (3 ft/s) in gravity flow.
(3) Plumbing color coding. All exposed piping and valves should be identified by color code in accordance with Table 4. Where two colors do not have sufficient contrast to easily differentiate between them, a six inch band of contrasting color should be painted on one pipe at approximately thirty inch (30") intervals. The name of the liquid or gas and arrows indicating direction of flow should be shown on the pipe.
Table 4: Plumbing Color Coding Schedule
Category Color Code Piping Potable water lines Dark blue Filtered water Aqua Skimmer or gutter return Olive green Main drain Black Alum Orange Chlorine (gas/solution) Yellow Soda ash White Acid Pink Waste lines Backwash waste Dark brown Sewer Dark gray Deck drains Light brown Other Compressed air Dark green Gas Red
(4) Installation and draining of pipes. All equipment and piping shall be designed and fabricated to drain completely by use of drain plugs, drain valves or other means. All piping shall be supported continuously or at sufficiently close intervals to prevent sagging. All suction piping shall be sloped in one direction, preferably toward the pump. All supply and return pipelines to the pool and/or spray pad shall be provided with valves or other means to allow the piping to be drained to a point below the frost line. Provision shall be made for expansion and contraction of pipes.
(d) Selection of recirculation pumps. The recirculation pump shall have adequate capacity (flow rate and pressure) to meet the design requirements of the pool and/or spray pad treatment tank, including filter backwashing and turnover rate. It shall be of a self-priming type if installed above the hydraulic gradient. A gauge which indicates both pressure and vacuum shall be installed on the pump suction header and a pressure gauge shall be installed on the pump discharge line. Gauges shall be installed as near to the pump inlet as possible.
(e) Strainers and screens. The recirculation system shall include suitable strainer(s) or screen(s) to prevent hair, lint, and other debris from reaching the pump and filters. The strainers shall be of rigid construction, fabricated of corrosion-resistant material and of adequate strength to withstand maximum anticipated loading including pressure. The openings shall be no greater than one-eighth inch in any dimension. The total clear area of all openings shall be at least four times the area of the connecting pipe. The strainer shall have a quick-opening cover. One spare strainer basket shall be provided for each strainer. In systems where the filter is located on the suction side of the pump, strainers are not required.
(f) Inlets (for pools). Wall or floor inlets shall be provided for all pools and shall be located and directed to provide distribution of treated water to facilitate the maintenance of a uniform disinfectant residual throughout the entire pool.
(1) Number. Wall inlets shall be spaced at a distance of no greater than twenty feet (20') apart, with one inlet within five feet (5') of each corner of the pool and one in each recessed step area or other space where water circulation might be impaired.
(2) Location. Wall inlets shall be located at least twelve inches (12") below the design water surface. Bottom inlets shall be uniformly spaced with a separation distance of no greater than twenty feet (20') and with rows of inlets within fifteen feet (15') of each side wall. In any pool over sixty feet (60') in width, floor inlets should be provided. These shall be flush with the floor.
(3) Type. Inlet fittings shall be of the adjustable rate-of-flow type. Directional flow inlets shall be used with skimmer type pools. Inlets shall not extend from the floor or wall to create a hazard.
(4) Testing. Dye testing (crystal violet or equivalent) should be performed to determine and adjust the recirculation pattern.
(g) Main drains (for pools). Every pool constructed after July 15, 1998, shall have at least two hydraulically balanced main drains to the pool filter system installed in the pool floor at the deepest point. The minimum distance between the main drains shall be three feet (3') measured from center to center of the drains. If the floor of a spa pool is insufficient for a separation distance of three feet (3'), then the separation distance shall be as great as possible. The main drains shall be connected to a single main suction pipe by branch lines and the branch lines shall not be valved so as to be capable of operating independently. Pools constructed before July 15, 1998, shall have at least one main drain installed in the pool floor at the deepest point.
(1) Location. The main drains shall not be spaced at more than twenty feet (20') on centers and fifteen feet (15') from side walls and shall be connected in parallel.
(2) Grating. The main drain shall be protected by gratings or other approved covers having an opening sufficient to restrict water velocity to less than 1 1/2 feet per second through the grating. The maximum width of grate opening shall be one-half inch. Gratings or drain covers shall not be removable without the use of tools.
(3) Piping. Each main drain shall be connected to the recirculation system. The branch pipe from each main drain shall be designed to carry at least one hundred percent (100%) of the design recirculation flow rate. The single main suction pipe to the pump shall be equipped with a valve to control total main drain flow. The suction velocity in the pipe shall not exceed six feet per second (6 ft/s).
(4) Minimum flow. At least thirty percent (30%) of the total recirculation rate should flow through the main drains.
(5) A hydrostatic relief valve shall be provided at each main drain for in-ground pools.
(h) Surface skimmer systems (for pools). A surface skimmer system, perimeter overflow system or recessed automatic surface skimmers, shall be provided on all pools and shall be designed and installed to continuously remove all floating material, surface dirt and waste water. A perimeter overflow system shall be required on all pools which have a pool width exceeding thirty feet (30'), or a surface area of over one thousand six hundred square feet (1,600 ft 2 ). Pools having a width of thirty feet (30') or less, or a surface area of one thousand six hundred square feet (1,600 ft 2 ) or less shall be provided either with perimeter overflows or skimmers. A combination of perimeter overflow systems and skimmers may also be used when approved by the department. All overflow systems and skimmers shall be capable of continuously removing all floating material, surface dirt and waste water.
(1) Perimeter overflow systems. All pools shall be designed to provide continuous skimming from the pool's surface at a rate of at least one hundred percent (100%) of recirculation rate. In pools where perimeter overflow systems are provided, the following shall be met:
(A) Design. The perimeter overflow systems shall extend completely around the pool, except at steps or recessed ladders in the shallow portion and shall be level to a tolerance of one-eighth inch (1/8"). The gutter shall be capable of continuously removing one hundred percent (100%) of the recirculation water and return it to the filter.
(B) Size and shape. The gutters, drains and return piping to the surge tank shall be designed to rapidly remove overflow water caused by recirculation displacement, wave action or other causes produced from the maximum pool bathing load. Make-up water supply equipment shall be provided to maintain continuous skimming.
(C) The gutter shall be designed to serve as a handgrip and to prevent entrapment of bather's arms, legs and feet. It shall permit ready inspection, cleaning and repair.
(D) The overflow gutter outlets shall be provided with outlet pipes at least two inches (2") in diameter. The outlet fittings shall have a clean opening in the grating at least equal to 1.5 times the cross-sectional area of the outlet pipe.
(E) Drainage shall be sufficient to minimize flooding and prevent backflow of skimmed water into the pool.
(F) Surge capacity. All overflow systems shall be designed with an effective surge capacity of not less than one gallon for each square foot of pool surface area. Surge shall be provided within a surge tank, in the gutter or filter above the normal flow line, or elsewhere in the system. Surge tanks, gutters and filter tanks should have overflow pipes to convey excess water to waste. Surge tanks shall be provided with means for complete draining.
(2) Skimmers. Skimmers shall be designed and installed to prevent electrical hazards or short circuiting. Recessed automatic surface skimmers are permitted on pools where the width does not exceed thirty feet (30') and a water surface area is less than one thousand six hundred square feet (1,600 ft 2 ). In pools where skimmers are provided, the following shall be met:
(A) Number. One skimmer for each four hundred square feet (400 ft 2 ) of water surface area or fraction thereof shall be provided. Additional skimmers may be required to achieve effective skimming.
(B) Location. Skimmers shall be so located to optimize skimming of the entire water surface with minimum interference and placed so as to prevent short circuiting. Prevailing wind direction and the pool outline shall be considered in the selection of skimmer locations and the location of skimmers shall be such that the interference of adjacent inlets and skimmers is minimized.
(C) Capacity. The piping and other pertinent components of skimmers shall be designed for a total capacity of one hundred percent (100%) of the required filter flow of the recirculation system and no skimmer shall be designed for a flowthrough rate less than thirty gallons per minute per foot (30 gpm/ft) of weir length.
(D) Control. Skimmers shall have weirs that adjust automatically and operate freely and continuously with variations of at least four inches in water level. All skimmed water shall pass through an easily removable and cleanable basket or screen before encountering control valves or entering the pump suction line. Each skimmer shall be equipped with a device to control flow.
(E) Relief line. Skimmers shall include a device to prevent an air lock in the suction line. If equalizer pipes are used, they shall pass an adequate amount of water to meet pump suction requirements should pool water drop below the weir level. The equalizer pipes shall be located at least one foot below the lowest overflow level of the skimmer. A valve or equivalent device that will remain tightly closed under normal operating conditions, but automatically open when the water level drops below the minimum operating level of the skimmer, shall be provided on each equalizer pipe.
(F) Construction. Skimmers shall be installed in the pool walls, be sturdy and be constructed of corrosion-resistant materials.
(G) Handgrips. Rounded coping not more than two inches (2") thick or other handgrip adjacent to the pool wall shall be provided. The handgrip shall not be more than nine inches above the minimum skimmer operating level. When the handgrip is formed by the pool deck, it shall slope away from the pool with a one-inch (1") drop in a one-foot (1') distance.
(H) Testing. Flotation testing should be performed to determine and adjust the recirculation system for optimum skimming.
(i) Filtration. The filtration system shall be designed to maintain the required pool and/or spray pad water quality. A water treatment system shall have one or more filters. Filters shall be installed with adequate clearance and facilities for ready and safe inspection, maintenance, disassembly and repair.
(1) Sand filters. The design filtration rate of rapid sand filters shall not exceed three gallons per minute per square foot (3 gpm/ft 2 ) of bed area at time of maximum head loss with sufficient area to meet the design rate of flow by the prescribed turnover rate. High-rate sand filters (pressure or vacuum) shall not exceed a filtration rate of fifteen gallons per minute per square foot (15 gpm/ft 2 ) of bed area. For multiple-cell rapid sand filters, the rate of filtration shall not exceed three gallons per minute per square foot (3 gpm/ft 2 ) of filter area. For multi-cell high-rate sand filters, filtration rate shall not exceed five gallons per minute per square foot (5 gpm/ft 2 ) of filter area. The sand filter system shall be equipped to backwash each filter at a rate of twelve to fifteen gallons per minute per square foot (12 to 15 gpm/ft 2 ) of filter bed area, or as recommended by the manufacturer. The backwash water shall be discharged to waste through a suitable air gap.
(A) Filter media. Sand or other media shall be carefully graded and meet the manufacturers' recommendation for pool use.
(B) Accessories. Influent pressure gauge, effluent pressure gauge, backwash sight glass and air relief valve shall be provided on all sand filters. Where multiple filter tanks are used a separate gauge panel shall be provided for each filter tank.
(2) Diatomaceous earth filters. The design filtration rate for pressure or vacuum type filters shall be no greater than 1.5 gallons per minute per square foot of effective filter area, except that a maximum filtration rate of two gallons per minute per square foot (2gpm/ft 2 ) may be allowed where continuous application of filter material is provided ("body slurry feed," see below). The filter and all component parts shall be of such materials, design and construction to withstand normal continuous use without significant deformation, deterioration, corrosion or wear which could adversely affect filter operation.
(A) Precoating. Provision shall be made to introduce a precoat of diatomaceous filter aid to evenly cover the filter elements upon placing the equipment into initial operation and after cleaning. For pressure-type filters, the amount of filter aid shall be selected to provide at least the same protection to the filter element as that afforded by no less than 0.1 pound of diatomaceous earth filter aid per square foot of filter area.
(B) Backwash and precoating. Whenever the filter is backwashed or precoated, the filter piping shall be installed to permit continued recirculation of the water from the effluent back to the influent until a satisfactory clear effluent is produced prior to admitting the water into the pool, or to be discharged as waste water as an alternative.
(C) Body or slurry feeding. Where provided, the body feeding equipment designed for feed of filter aid to the filter influent shall be capable of applying not less than 0.1 pound of diatomaceous earth per square foot of filter area per 24 hours.
(D) Regenerative-type filters. Regenerative type of filters shall meet the same standards as pressure filters. Pumping by air or manual means shall be provided for and provision for visual inspection of elements shall be provided.
(E) Accessories for pressure-type filters. Each pressure-type filter requires a backwash sight glass, effluent pressure gauge, influent pressure gauge and air relief valve.
(F) Accessories for vacuum-type filters. A compound gauge which will indicate both positive and negative head shall be installed on the suction side of the pump. An adjustable high vacuum switch should be provided to prevent damage to the pump by cavitation.
(3) Cartridge filters. The design filtration rate for cartridge filters of depth type shall be less than three gallons per minute per square foot (3 gpm/ft 2 ) of cartridge cylinder surface area. For surface type, the design filtration rate for cartridge filters shall not exceed 0.375 gallon per minute per square foot (0.375 gpm/ft 2 ) of the pleated area of the cartridge. Influent pressure gauge, effluent pressure gauge and air relief valve shall be provided on all the filters. One complete extra set of filter cartridges shall be on hand at the facility's location.
(j) Flow measurement and control.
(1) Flow measurement. A means of continuously measuring rate of flow shall be provided in the recirculation system. For sand filters, the flow-measuring equipment shall be located where the backwash flow rate can also be determined. The indicator shall be capable of measuring at least 1 1/2 times the design flow rate and shall be accurate within ten percent (10%) of true flow. The indicator shall have a range of readings appropriate for the anticipated flow rates, and be installed where it is readily accessible for reading and maintenance, and with straight pipe upstream and downstream of any fitting or restriction in accordance with the manufacturer's recommendation.
(2) Flow regulation. Where multiple pumps or filters are provided, each unit shall have a flow-regulating device installed. For spray grounds, automatic devices shall be provided for regulating the rate of flow through the filtration system and flow to the spray features.
(k) Water heater and thermometer (pools). A water heater shall be installed at all indoor pools. Heaters shall be installed in accordance with the standards contained in the Building Code and the manufacturer's recommendations. Heating coil, pipe or steam hose shall not be installed in a pool. Pools equipped with heaters shall have a fixed thermometer in the recirculation line downstream of the heater and another near the outlet of the pool.
(l) Disinfection and chemical feeders. Pools and/or spray pad treatment shall be designed to provide for continuous disinfection of the pool and/or spray pad water with a chemical which is an effective disinfectant and which imparts an easily measured, active residual. The pools and/or spray pad shall be equipped with a chlorinator, hypochlorinator, or other disinfectant feeder or feeders. An automatic controller shall be provided for continuous monitoring and adjusting the level of free residual disinfectant in the spray pad treatment tank. An automatic device shall be provided to deactivate chemical feeders when there is not flow in the spray pad treatment recirculation system. The feeder shall be automatic, easily disassembled for cleaning and maintenance, and capable of providing the required chemical residuals which meet the following requirements:
(1) Design specifications. The feeder shall be of sturdy construction and materials which will withstand wear, corrosion or attack by disinfectant solutions or vapors, and which are not adversely affected by repeated, regular adjustments or other normal use conditions. The feeder shall not allow flow of unintended chemicals or those containing foreign materials into the pool and/or spray pad treatment. The feeders shall incorporate anti-siphon safeguards so that the disinfectant cannot continue to feed into the pool and/or spray pad treatment tank, the pool piping system, the pool enclosure, spray pad treatment tank, the spray piping system or the spray pad enclosure if any type of failure of the equipment occurs.
(2) Point of addition of disinfectant. All chemicals shall be fed into the return line after the pump, filter and heater unless the feeder is otherwise designed and specified by the manufacturer, and approved by N.S.F. and the department.
(3) Equipment capacity. Feeders shall be capable of supplying disinfectant to the pool and/or spray pad treatment in a range of chlorine demand of up to 10 mg/l or equivalent.
(4) Disinfection with bromine or solid forms of chlorine. Where bromine or chlorine in stick or pellet form is used as a disinfectant, equipment shall be provided for feeding on continuous feed.
(5) Disinfection with ozone. Ozone generating equipment (OGE) is acceptable only as a supplement to chlorine or bromine disinfection system. OGE and its components shall be listed by N.S.F. or other listings that are approved by the department and meet the following design standards:
(A) The ozone concentration in the pool water shall be less than 0.10 mg/l. Off-gassing of ozone shall not result in ozone levels exceeding 0.10 mg/l in the equipment room or in the pool area. When the OGE is installed and annually thereafter, the air space within six inches (6") of the pool water level and air in the equipment room shall be tested to determine compliance with this requirement.
(B) All corona discharge OGE systems shall be vacuum systems.
(C) Backflow of pool water into OGE shall not occur.
(6) Hypochlorinators (positive displacement pumps). Where positive displacement pumps are used to inject the disinfectant solution into the recirculation line, the following requirements shall apply:
(A) Feed. Feed shall be continuous at the proper addition rate under all conditions of pressure in the recirculation system without constriction of the recirculation pump suction.
(B) Solution tanks. If granular calcium hypochlorite is used, two solution tanks, each with minimum capacity of one-day supply, should be provided. All chemical containers including those used with chemical feeders shall be clearly labeled regarding their contents.
(7) Gas chlorination. Gas chlorination is prohibited. Chlorine gas shall not be used or stored except under permit from the Fire Department and in accordance with Building Code reference standards and as approved by the Department.
(8) Copper/silver and copper ion generators. All copper/silver and copper ion generators shall be approved by N.S.F. or equivalent which are approved by the department and are acceptable only as a supplement to chlorine or bromine disinfection system.
(9) Ultraviolet light disinfection units. All spray pad treatment systems shall provide ultraviolet light disinfection systems unless the provision of an alternative treatment process has been approved by the New York State Department of Health to be capable of providing the equivalent level of reduction of cryptosporidium as the ultraviolet light disinfection system specified in this article. The ultraviolet light unit shall be located between the spray pad treatment tank pump discharge and the spray features or as approved in accordance with 24 RCNY Health Code § 165.45(a)(2)(A). The following requirement for ultraviolet light shall apply:
(A) All ultraviolet light units must be validated with dosage by an independent agency with dosage. The validation process must determine the ultraviolet light unit's disinfection performance by indicating that a dose of 40mJ/cm 2 (at end of lamp life) is achieved at a flow rate equal to or greater than the design flow rate at the setpoint intensity. The validation procedure used must have been determined by the State Department of Health to be capable of demonstrating the disinfection performance described above.
(B) For systems utilizing quartz sleeves to separate the water passing through the chamber from the ultraviolet source, the system shall be designed to permit cleaning of the lamp jackets and the sensor window or lens without mechanical disassembly. For systems utilizing polytetrafluoroethylene (PTFE) surface materials to separate the water that flows through the ultraviolet chamber from the lamps, the ultraviolet unit shall be designed to be readily accessible to the interior and exterior of the PTFE. The ultraviolet unit shall be designed to permit use of either physical or chemical cleaning methods.
(C) An accurately calibrated ultraviolet light intensity meter, properly filtered to restrict its sensitivity to the disinfection spectrum shall be installed in the wall of the disinfection chamber at the point of greatest water depth from the tube or tubes.
(D) An automatic system shall be installed to prevent flow to the features in the event the ultraviolet light intensity decreases below the validated set point.
(E) An automatic, audible alarm shall be installed to warn of ultraviolet light disinfection system malfunction or impending shutdown.
(F) The unit shall be designed to protect the operator against electrical shock or excessive radiation.
(G) Installation of the unit shall be in a protected enclosure not subject to extremes of temperature.
(H) A spare ultraviolet lamp and other necessary equipment to effect prompt repair by qualified personnel properly instructed in the operation and maintenance of the equipment shall be provided on-site.
(m) pH control. Mechanical feed equipment for the purpose of adding a chemical for pH adjustment shall be provided for all pools and spray grounds built. An automatic controller shall be provided for continuously monitoring and adjusting the level of pH in the spray pad treatment tank. The method of chemical addition shall protect the bather from contact with concentrated chemicals. Soda ash, caustic soda, sodium bisulfate, carbon dioxide gas, muriatic acid, or other chemicals approved for water supply use by the United States Environmental Protection Agency, as food additives by the United States Food and Drug Administration, or by the Department, shall be used to raise or lower pool water pH. The method shall provide adequate distribution of the chemical throughout the pool and distribution shall be verified by pool water testing prior to bather exposure. Where carbon dioxide (CO2) is used as a method of pH control, the following features shall be provided:
(1) CO 2 shall be injected into the recirculation pipe at the same point where pH adjustment solutions (i.e., acid) would normally be added. The recirculation pipe shall be of sufficient size and length to provide a minimum of five seconds contact time prior to bather contact.
(2) CO 2 cylinders shall be anchored to prevent damage. Cylinders shall be inaccessible to the general public.
(3) The manufacturers' instructions shall be followed for installation and operation of cylinders. The units shall be operated by the pool operator as specified in the pool safety plan.
(4) CO 2 cylinders shall be stored in a protective enclosure at the exterior of occupied structures. If CO 2 cylinders are provided in the interior of occupied structures, they shall be placed in a ventilated enclosure.
(n) An automatic device shall be provided to deactivate chemical feeders when there is no flow in the recirculation system.
(o) Pool vacuum system and cleaning system (for pools). A cleaning system should be provided to remove sludge, sediment and other accumulations from the bottom of the pool. When a vacuum system is used as an integral part of the recirculation system, hose connections shall be located in the walls of the pool at least eight inches (8") below the waterline, and at such points that the floor of the pool can be cleaned with not more than fifty feet of suction hose.
(p) Spray Pad Treatment Tank (for spray grounds only). The spray pad treatment tank that receives the effluent water from the spray pad shall conform to the following specifications:
(1) Material. The spray pad treatment tank shall be constructed of materials which are inert, corrosion resistant, nontoxic, and watertight such as concrete, fiberglass, stainless steel, etc., which can withstand all anticipated loadings under full and empty conditions.
(2) Volume. The volume of the water in the spray pad treatment tank shall be sufficient to assure continuous operation of the filtration system. The capacity shall be measured from six inches above the uppermost pump inlet to the bottom of the overflow waste outlet.
(3) Controller. An automatic water level controller shall be provided for the spray pad treatment tank.
(4) Ready Access. The spray pad treatment tank must be designed to provide ready access for cleaning and inspections, and be capable of complete draining. An overflow pipe to convey excess water to waste through a suitable air gap must be provided.
(5) Backflow Prevention. The makeup water shall be introduced into the spray pad treatment tank through an air gap or by another method which will prevent back flow and back-siphonage.
(6) Screen. A screen or similar device shall be provided through which all water from the spray pad shall pass before entering the spray pad treatment tank or another method/process described to provide for removal of debris on the surface layer of the spray pad treatment tank water.
(7) Filtered/Treated Water Inlets. An adequate number of filtered or treated water inlets shall be provided and located for complete mixing and circulation of treated water within the spray pad treatment tank.
(8) Drain. At least one main drain suction outlet supplying water to the spray pad treatment tank filtration system shall be provided at the deepest point in the spray pad treatment tank.
§ 165.47. Lighting and Electrical Installation, Ventilation and Heating Requirements
(a) Lighting and electrical installation. Artificial lighting shall be provided for all bathing establishments which are to be used at night, or which do not have adequate natural lighting. The light and electrical installation shall be provided in accordance with the following:
(1) All new electrical wiring shall conform with Chapter 3 of Title 27 of the Administrative Code of the City of New York, entitled the "Electrical Code" and the National Electrical Code of the National Underwriters Laboratory, or any successor regulation or code.
(2) Underwater. When underwater lighting is used, not less than 8.35 lumens or 0.5 watt per square foot of pool water area shall be provided. Such lights shall be spaced to provide illumination so that all portions of the pool including the bottom, may be readily seen without glare. Overhead illumination on the water surface shall be a minimum of 30 foot-candles.
(3) If underwater lights are not provided, a minimum illumination of 50 foot-candles on the water surface and the deck shall be provided.
(4) Decks. A minimum of 50 foot-candles should be provided at deck area and/or spray pad.
(5) The illumination level in indoor pools and/or spray grounds shall be so designed to limit glare and excessive reflection.
(6) No overhead electrical wiring, except when secured within a ceiling, shall pass within twenty feet (20') of the pool enclosure and/or spray pad.
(7) Emergency lighting. All indoor pools where night swimming is permitted, and indoor pools where no natural light is present shall be provided with an adequate emergency lighting service. For outdoor pools, a portable battery powered light source is acceptable and shall be adequate and maintained to facilitate pool evacuation.
(8) Electrical outlets. Lighting or other electrical outlets in the deck, spray pad, shower room, and the water treatment areas shall have properly installed ground fault circuit interrupters (GFCI) at the outlet.
(9) Each underwater light shall be individually grounded by means of an adequate ground-wire with a screwed or bolted connection to the metal junction box from which the branch circuit to the individual light proceeds. Such junction boxes shall not be located in the pool deck within four feet of the pool wall.
(10) Equipment room and storage area. All pool equipment and chemical storage rooms shall be provided with artificial lighting sufficient to illuminate all equipment and supplies.
(11) Sauna and steam rooms. All electrical installation shall be in accordance with manufacturer's instruction and 24 RCNY Health Code § 165.47(a)(1).
(b) Ventilation.
(1) General. All indoor pools and/or spray grounds shall be adequately ventilated, either by natural or mechanical means. Indoor portions of a bathing establishment, including indoor pools and/or spray grounds, dressing rooms, mechanical equipment rooms, storage areas, bathhouses, shower rooms and lavatories shall be ventilated pursuant to Article 12 of the Building Code or any successor law or regulation. The ventilation system for indoor pools and dressing rooms shall be designed so the bathers are not subjected to drafts and shall minimize condensation. A minimum of two air changes per hour shall be provided for indoor pool and/or spray ground areas. Any heating units shall be kept from contact with swimmers. Fuel burning heating equipment shall be installed and vented to the outdoors in accordance with the Building Code.
(2) Carbon dioxide. For facilities using carbon dioxide (CO 2 ) as the method of pH control, where cylinders are provided in the interior of occupied structures they shall be placed in a ventilated enclosure. A louvered fresh air intake shall be provided near the ceiling. Mechanical exhaust ventilation shall be provided at the rate of one air change every three minutes and take suction near the floor as far as practical from the door and fresh air intake. Exhausted air shall be ducted to the exterior of the building through a continuous pipe of at least 1 1/2 inches in diameter with the point of discharge so located as not to contaminate air inlets to any rooms or structures.
(c) Heating. A heating apparatus of sufficient capacity to heat the rooms to 75 degrees Fahrenheit shall be provided in dressing rooms, shower rooms, lavatories and pool areas used at times other than the summer months and shall be operated so as to maintain a minimum of 70 degrees Fahrenheit whenever the rooms are in use. Any heating apparatus used to heat the air in indoor portions of a bathing establishment shall be equipped with adequate protective guards and venting.
§ 165.49. Bathhouse and Bather Preparation Facilities
(a) General. All bathing establishments shall have toilet facilities for each gender (as appropriate) within 300 feet and no more than one floor level above or below the bathing facility. Except where the bathing establishment is intended to serve as living units (such as hotel, motel, apartments, condominium and residents' institutions), there shall be a bathhouse and bather preparation facility for each gender provided with lockers, showers and toilets.
(b) Location. For all pools, the bather preparation facility shall be located so that the patrons shall pass through the bather preparation facilities to enter the pool. The layout of the preparation facilities shall be such that the patrons on leaving the dressing room pass the toilets and then the showers en route to the pool. For spray grounds, the bather preparation facility shall be conveniently located.
(c) Materials. Floors of the facility shall be of smooth-finished material with nonslip surfaces, impervious to moisture, easily cleanable and sloped at least one-fourth inch per foot (1/4"/ft) to drains. Carpeting shall not be permitted in shower and toilet areas. Junctions between walls and floors shall be curved and of smooth, impervious materials, free from cracks or open joints. Partitions between toilets and in dressing rooms shall be at least ten inches (10") off the floor or shall be placed on continuous raised masonry or concrete bases at least four inches high, and constructed of impervious, easily cleanable material.
(d) Design requirements. All bathing establishments shall have an adequate number of toilets in properly ventilated compartments. The number of toilets to be provided shall be based upon the maximum number of persons, both adults and children, who can be accommodated in a bathing establishment at any one time. A bathing establishment shall have at least one toilet for every 40 female bathers, at least one toilet and one urinal for every 60 male bathers and at least one wash basin adjacent to the toilets for every 60 persons. A minimum of two toilets for female bathers shall be provided at every facility.
(e) Shower room. The number of shower heads to be provided shall be based upon the maximum number of persons, both adults and children, who can be accommodated in a bathing establishment at any one time. In no case shall there be fewer than two showers. A bathing establishment with indoor bathing facilities shall have at least one shower for every 40 persons of each sex. A bathing establishment with outdoor bathing facilities shall have at least one shower for every 80 persons of each sex. Showers in all bathing establishments shall have hot and cold running water. Showers shall be supplied with water at a temperature of at least ninety degrees Fahrenheit (90 °F) and no more than one hundred and ten degrees Fahrenheit (110 °F) and at a minimum rate of 1.5 gallons per minute and a maximum rate of 2.5 gallons per minute per shower. If shower curtains are used, they shall be of plastic or other impervious material and shall be kept clean. Heavy duty wall mounted soap dispensers (glass prohibited) shall be provided at each individual shower stall or at a rate of one dispenser per two shower heads in a common shower room containing more than one shower head.
(f) Lavatories. All lavatories shall be provided with liquid soap in an acceptable dispenser, paper towels or other individual towels or electrical hand-drying units and covered waste receptacles. Common use of bar soap or cloth towels shall not be permitted. Suitable sanitary napkin receptacles shall be provided in female toilet rooms. For spray grounds, a diaper changing area shall also be provided.
(g) Lockers. Lockers shall be set either on solid masonry or concrete bases at least four inches above the floor. Lockers shall be vented.
(h) Hose bibbs. Hose bibbs shall be provided within the bathhouse to enable the entire area to be flushed with a fifty foot (50') hose. Hose bibbs shall be provided with an anti-siphonage device.
§ 165.51. Additional Requirements for Wading Pools
(a) Wading pools shall comply with the additional provisions of this section:
(1) Maximum depth. The maximum water depth for wading pools shall be twenty-four inches (24") at any point.
(2) Enclosure. Except for pools constructed before March 24, 1959, a fence or other effective barrier at least four feet (4') in height, to separate the wading pool from other pools, shall totally enclose the wading pool and have a gate or door with a self-closing and self-latching mechanism.
(3) After the effective date of this article, where a wading pool is constructed in proximity to a swimming or wave pool, the wading pool shall be at the shallow end of the adjacent pool.
§ 165.53. Additional Requirements for Spa Pools
Spa pools shall comply with the additional provisions of this section:
(a) Maximum depth. The maximum water depth shall be four feet (4') measured from the waterline. The maximum submerged depth of any seat or sitting bench shall be two feet measured from the water line.
(b) Location. After the effective date of this Article, where a spa pool is constructed in proximity to a swimming or wave pool, the spa pool shall be at the shallow end of the adjacent pool with a minimum distance of five feet (5') between the pools.
(c) Handholds. All spas shall have one (1) or more suitable, slip-resistant handhold(s) around the perimeter, located no further than four feet (4') apart and not over twelve inches (12") above the water line. The handhold(s) may consist of rounded coping, ledge or decks along the immediate top edge of the spa; ladders, steps or seat ledges; and ropes or railings.
(d) Steps. Design of steps shall conform to the following:
(1) Step treads shall have a minimum unobstructed horizontal tread depth of 10 inches for a minimum continuous width of twelve inches (12").
(2) Riser height shall not be less than seven inches (7") nor greater than twelve inches (12"). When the bottom tread serves as a bench or seat, the bottom riser may be a maximum of fourteen inches (14").
(3) Step treads shall have slip-resistant tread surfaces.
(4) Each set of steps shall be provided with at least one handrail to fully serve all treads and risers.
(5) Seats or benches may be provided as part of the steps.
(e) Overflow system. An overflow system shall be provided. It shall be designed and constructed so that the water level of the spa is at the operating level of the rim or weir device during use and non-use of the spa. When surface skimmers are used, one surface skimmer shall be provided for each one hundred square feet (100 ft 2 ) or fraction thereof of spa surface area. Recirculation through the skimmer shall be at least 30 gpm/skimmer. When two or more skimmers are used in a spa, they shall be located to maintain effective skimming action over the entire surface area of the spa. Skimmers shall conform to 24 RCNY Health Code § 165.45.
(f) Air induction systems. An air induction system shall be designed to prevent water backup that could cause electrical shock hazards. Air intake sources shall not permit the introduction of toxic fumes or other contaminants.
(g) Heater and temperature requirements. The maximum temperature of the spa water shall not exceed 104 degrees Fahrenheit. A thermostatic control for the water shall be required. An alarm system set to ring a bell or buzzer shall be installed to warn of any temperature over 104 degrees Fahrenheit. The alarm shall ring in the spa area as well as at the attendant's normal work station. The alarm system shall turn off the heat when the alarm sounds, and not allow the heater to be reset until the water temperature has cooled below the maximum level. A manual timer shall be installed that will require resetting after 15 minutes. This timer shall be set to ring a warning bell and may control the agitation pump. The heater shall be designed pursuant to 24 RCNY Health Code § 165.45(k). Existing pools requiring modification to comply with this paragraph shall be in compliance on and after September 1, 2001.
(h) Emergency switch. For all spa pools, a clearly labeled emergency shutoff or control switch for the purpose of stopping the motor(s) that provide power to the recirculation system and jet system shall be installed readily accessible to the bathers at least five feet away, adjacent to, and within sight of the spa. Existing pools requiring modification to comply with this paragraph shall be in compliance on and after September 1, 2001.
§ 165.55. Additional Requirements for Physical-Therapy Pools
Physical-Therapy pools shall comply with the additional provisions of this Section:
(a) General. Facilities for persons with physical disabilities shall be designed to provide safe entry and exit from the bathing establishment. Facilities for parking, path of travel, walks, ramps, drinking fountains, telephones, toilets and showers shall comply with the requirements of the Building Code.
(b) Pool entry. Access for persons with physical disabilities shall be at the shallow end of the pool. Pool entry shall be an eighteen inch (18") high block of steps followed by a normal set of pool steps. As an alternate, hoists or ramps are acceptable. Where removable ramps or steps are provided, the area beneath the ramp or steps shall be protected to prevent access to swimmers.
(c) Steps and handrails. Stair steps should have risers 5 3/4 inches high and a tread 12 to 18 inches wide to allow for sitting. A handrail thirty-two inches (32") high, extending eighteen inches (18") beyond top and bottom steps, shall be provided. A twenty-two inch (22") handrail shall be provided for children. A six inch (6") handrail shall aid entry for those who cannot stand.
(d) Wheelchairs. Wheelchairs, if immersed in a pool, shall be safe, waterproof and designed for use in the pool environment.
§ 165.57. Additional Requirements for Movable-Bottom Pools
Movable-Bottom pools shall comply with the additional provisions of this section:
(a) Design. Hydraulic lift swimming pool floors where provided, shall be safe and maintenance-free.
(b) Inlets. A jet-water self-cleaning system should be provided so that the entire pool is self-cleaning. Two sets of return inlets located at two different heights should be provided to obtain adequate mixing at all times when the pool is shallow or deep.
(c) Floor movement. Floor movement shall be designed to minimize turbulence and provide safe entry and exit by persons with physical disabilities.
(d) Depth signs. A sign for pool water depth in use shall be provided and clearly lit and visible. "NO DIVING" sign shall also be provided. The control panel for changing water depth shall be located in a safe place which is accessible only to aquatic supervisory staff or pool operator.
(e) Diving boards. For depths other than design diving depth, the diving board shall be in an upright position and chained or secured to prevent use.
§ 165.59. Additional Requirements for White-Water Slides
Pools with white-water slides shall comply with the additional provisions of this section:
(a) General. All slides shall be designed and constructed in accordance with the manufacturers' instruction to carry the anticipated load. All curves, turns and tunnels on the path of flume shall be designed and constructed in accordance with manufacturers' instruction.
(b) Water slide landing area. The landing area for a water slide flume shall comply with the following:
(1) The minimum plunge pool operating water depth shall be three feet (3'). This depth should be maintained in front of the flume for a distance of at least twenty feet (20').
(2) If the water slide flume shall end in a swimming pool, the landing area shall be divided from the rest of the swimming pool by a float line or as approved by the department.
(c) Slide position. The slide flume shall be perpendicular to the plunge pool back wall for a distance of at least ten feet (10') from the exit end of slide. The flume shall terminate between a depth six inches below to two inches above the pool water surface level. The distance between the side of a flume exit and a plunge pool side wall should be at least five feet (5'). The distance between sides of adjacent terminuses should be at least six feet (6').
(d) Pump reservoir. A pump reservoir shall be provided for the slide pump intakes. It shall be connected to the plunge pool by a weir. The minimum reservoir volume shall be equal to twice the combined flow rate in gallons per minute of all filters and slide pumps.
(e) The flume shall be designed to prevent users from becoming airborne while in the ride.
§ 165.61. Additional Requirements for Wave Pools
Wave pools shall comply with the additional provisions of this section:
(a) Perimeter overflow. A perimeter overflow gutter system shall be provided. The gutter may be interrupted in the area where the water is less than two feet deep. The total capacity of the gutter shall be designed to carry one hundred percent (100%) of recirculation rate.
(b) Entrapment prevention. Any opening or connection between the wave pool and wave generator system shall be designed and constructed to prevent entrapment of bathers.
(c) Lifeguard chairs. Two lifeguard chairs shall be located along the deck edge on each side of wave pool where water depth is 3 feet or greater.
(d) Emergency switches. Switches which will stop the wave action shall be provided at each lifeguard chair.
§ 165.63. Sauna and Steam Rooms
All sauna and steam rooms shall be designed and constructed in accordance with the following requirements:
(a) Temperature control. A sauna or steam room temperature shall be thermostatically controlled and shall not exceed 194 degrees Fahrenheit for a sauna room and 120 degrees Fahrenheit for steam room as measured at eye height.
(b) Doors and windows. A sauna or steam room shall be equipped with a free swinging type door or a door that swings outward freely and a window to facilitate viewing the interior of the room.
(c) Safety. The facility shall provide a one-hour timer to automatically disconnect all heating elements from the supply source at the end of one hour, or an attendant (meeting the definition of responsible person) who inspects the facility at a minimal interval of 15 minutes during all periods of operation of a sauna or steam room pursuant to 24 RCNY Health Code § 165.15(c), if the timer is not provided.
(d) Timing device and temperature indicator. A time and temperature indicator shall be provided in each sauna or steam room and shall be so installed as to be clearly visible to the patron in the sauna or steam room.
(e) Alarm system. An alarm system acceptable to the department shall be provided to indicate to the attendant and user any malfunction of the automatic temperature regulating control or of an electrical overloading of the equipment. The alarm system shall turn off the heat when the alarm sounds, and not allow it to be reset until the temperature has cooled to below the maximum allowable level. The operator shall be able to demonstrate the functioning of the alarm system to the department during an inspection. The alarm shall be tamper-proof. Patrons shall not be able to prevent the alarm from sounding, nor to prevent the heat from being cut off, nor to change the temperature set-point of the alarm.
(f) Heater.
(1) The heater unit used in a sauna room shall be approved by Underwriters Laboratories, Inc., or be equipped with equivalent control and safety features acceptable to the department, provided that the installation or any alteration of such unit has been approved by the Department of Buildings.
(2) If the unit is a gas-fired system, no door openings (either metal or otherwise) to the gas heater are to be located within the enclosure of the sauna.
(g) Steam generator. The size of the steam generator shall be adequate for the design capacity. There shall be adequate free space for access to the generator for maintenance.
(h) Warning signs. A durable plate bearing the following wording, in 24 point type (letters 0.25 inches in height) or more, permanently marked thereon in colors contrasting with the background, shall be prominently affixed outside the doors of the sauna or steam room at eye level containing the following: "Use of steam room or sauna should not exceed 30 minutes. Excessive exposure can be harmful to health. The Department of Health and Mental Hygiene recommends that persons who: – have poor health; or – have high blood pressure or a heart or circulatory disease; or – are using prescription medication; or – are pregnant not use this facility before consulting their physician. Persons under the influence of alcohol or drugs should not use this facility."
§ 167.01. Applicability
(a) This Article shall apply to all bathing beaches, as defined under 24 RCNY Health Code § 167.03, that are owned, leased or operated by a person, group of persons, firm, corporation, association, organization, institution or city agency, but shall not apply to bathing beaches owned and/or maintained by an individual for the use of the individual and/or family and friends wherein no monetary compensation or any other compensation or consideration is exchanged.
(b) A camp regulated and permitted under 24 RCNY Health Code Article 48 shall not require a permit under 24 RCNY Health Code Article 167, but shall comply with all other provisions of 24 RCNY Health Code Article 167.
§ 167.03. Definitions
(a) "Adequate" means sufficient to accomplish the purpose for which something is intended, and to such a degree that no unreasonable risk to health or safety is presented. An item installed, maintained, designed and assembled, an activity conducted or act performed, in accordance with generally accepted standards, principles or practices applicable to a particular trade, business, occupation or profession, is adequate within the meaning of this Article.
(b) "Approval" means an authorization, permit, certification or equivalent determination issued pursuant to requirements promulgated by the Department.
(c) "Aquatic Supervisory Staff" means an individual possessing the qualifications of Supervision Level I, Supervision Level IIb, or a supervising lifeguard, as defined in 24 RCNY Health Code § 167.19(c).
(d) "Bathing" means recreational activities where any part of the human body may come in direct contact with water to the point of complete body submergence. Bathing includes, but is not limited to, swimming, diving, and wading. Bathing does not include any activities where contact with the water is minimal and where ingestion of the water is not probable, such as fishing and boating.
(e) "Bathing Beach" means any waterfront area of the City with associated bathing beach facilities not specifically restricted by the by the provisions contained in 24 RCNY Health code § 167.05(d), where bathing is permitted regardless of whether it is recommended in accordance with the classifications given in 24 RCNY Health Code § 167.17. Bathing beach facilities include, but are not limited to, buildings, equipment, lavatories, toilets and showers or dressing facilities containing toilets and showers, if any, and the land areas used in connection therewith.
(f) "City" means the City of New York.
(g) "Department" means the New York City Department of Health and Mental Hygiene.
(h) "E. coli" means Escherichia coli a bacteria species which is a member of the family enterobacteriaceae which are the predominant facultative anaerobes in humans and warm blooded animal fecal material.
(i) "Enterococci" means enterococci bacteria, a subgroup of fecal streptococci that includes Enterococcus faecalis, Enterococcus. faecium, Enterococcus avium, and their variants. Enterococci bacteria are commonly found in the feces of humans and other warm-blooded animals. Although some strains are ubiquitous and not related to fecal pollution, the presence of enterococci in water is an indication of fecal pollution and the possible presence of enteric pathogens.
(j) "Fresh Water" in the City means any pond, lake or river in the City, including the Hudson River.
(k) "Geometric Mean" means the antilog of the summation of the logarithms of the values for samples examined divided by the number of samples.
(l) "Major Alteration, Renovation or Modification" means substantial physical changes to the bathing beach structure, enclosure, and electrical system or to the wastewater system. It does not include normal maintenance or repair.
(m) "Marine Water" means ocean and estuary water bodies. In the City, it means water bodies immediate to The Long Island Sound, Atlantic Ocean, and The New York Bight.
(n) "Preemptive Standards – New York City Wet Weather Advisory." A preemptive standard is a threshold level of precipitation that, when exceeded, can cause combined stormwater and sewage runoff to bypass the waste water treatment plants and overflow onto nearby receiving beach water bodies and may pose a public health threat. Based on hydraulic modeling of City waters, the Department issues Wet Weather Advisories each year for those bathing beaches directly impacted by wet weather.
(o) "Public Health Hazard" is any condition which poses an imminent threat to the health or safety of the public.
(p) "Qualified Lifeguard" means an individual possessing the qualifications of Supervision Level I and IIb as defined in 24 RCNY Health Code § 167.19(c).
(q) "Responsible Person" means a competent individual, at least 18 years of age, employed by the owner or operator of the bathing beach, who is capable of exercising control over the patrons and is trained in the use of lifesaving and safety equipment, in emergency procedures and the Beach Safety Plan.
(r) "Standard Method" means the most recent edition of the publication entitled Standard Methods for the Examination of Water and Wastewater, as published by the American Public Health Association, the American Water Works Association, and the Water Environment Federation.
§ 167.05. Permit Applications
(a) No person, group of persons, firm, corporation, association, organization or institution shall construct, operate, modify, maintain or grant permission for the use of any bathing beach without a permit issued by the Department. No bathing establishment shall be constructed nor shall any major renovation or modification be made to any bathing establishment unless a completed application for construction, alteration or addition is submitted to the Department for review and approval prior to commencement of work. The permit shall be posted conspicuously at the facility. The Department may order any bathing beach operating without a permit to close and remain closed until the bathing beach has obtained and displays a valid permit issued by the Department.
(b) Application. Application for a permit shall be made to the Department at least 30 days prior to the opening of any bathing beach. The application shall include appropriate fees, application forms and other supplemental information as required by the specific circumstances.
(c) Renewal. A bathing beach permit shall be renewed at least 30 days before reopening for the season. A bathing beach may be closed by the Department for failure to renew a bathing beach operating permit before reopening.
(d) Restriction. No person shall operate, construct or maintain and no permit shall be issued for a bathing beach within 750 feet of the point of discharge of the outlet of any sanitary sewer, the flow of which would contribute in any way to the pollution of the waters used by the bathers, and located outside the boundary delineated for primary contact recreation as defined by applicable regulations of the New York State Department of Environmental Conservation (see 6 NYCRR § 700.1; see also, 6 NYCRR Parts 890, 891). "Primary contact recreation" shall mean recreational activities where the human body may come in direct contact with raw water to the point of complete body submergence. Primary contact recreation includes, but is not limited to, swimming, diving, water skiing, skin diving and surfing.
(e) Requirements for Permit Approval. All bathing beaches shall be designed, constructed and completed in accordance with the requirements of this Article. For permit applications for new bathing beaches, the following must be submitted to the Department:
(1) A completed and approved Beach Safety Plan, as required by 24 RCNY Health Code § 167.23.
(2) Certificate of Occupancy for the bathing beaches from the City Department of Buildings including certificate of inspection for electrical work and plumbing.
(3) Copies of Aquatic Supervisory Certificates, as required by 24 RCNY Health Code § 167.19.
(f) Change in Ownership. In the event of change in ownership of any bathing beaches permitted under this Article, the owner shall file an application with the Department for a change in ownership within 30 days after such change has occurred.
(g) Exemption. No permit is required for operation of a bathing beach or for the construction or maintenance of a bathing beach facility by a State or Federal agency.
§ 167.07. New Construction, Major Renovation or Modification
No major alteration, renovation or modification shall be made in a bathing beach unless a written description of the alteration or repair or addition is submitted to and approved by the Department in writing prior to commencing work. Repair or remodeling of an existing permitted bathing beach shall be in compliance with the design and construction requirements in this Article. Prior to adapting a water body for use by siting or constructing a public bathing beach, and prior to major renovation or modification of a existing bathing beach, the Department shall review and approve the following:
(a) Engineering Plans, Specifications and Engineering Reports. Every owner, personally or through his or her engineer or architect, shall submit to the Department engineering plans, specifications and engineer's report covering construction, major alteration or modification of the bathing beach prior to the start of construction. Plans, specifications, and reports shall be prepared by an engineer or architect licensed to practice in the State of New York, and shall include at least the following:
(1) A Scope of Work Letter. The letter shall include a detailed discussion of the proposed work to be performed;
(2) Engineering plans. Three identical sets of engineering plans each bearing the seal and signature of an engineer or architect licensed to practice in the State of New York. The plans shall include the layout of the bathing beach, including, but not limited to: dimensions, bathhouses, access roads, parking, building, water supplies, sanitary and storm sewers, electrical and telephone services; and
(3) Specifications. One set of complete specifications for the construction of the bathing beach.
(b) Supplemental Information. An application shall be accompanied by any supplemental information, evidence, or documentation that the Department deems necessary.
(c) Proposed Bathing Beaches. In addition to the requirements set forth in subsections (a) and (b) of this section, an application to locate and/or construct a public bathing beach shall include, but not be limited to, the following:
(1) Site Assessment. A site assessment must include the following information:
(A) Watershed Map. A detailed map depicting the waterbody and watershed, including but not limited to existing wastewater treatment plant discharge points, combined sewer overflow discharges, septic systems, storm sewer outfalls, agricultural runoff, landfills, commercial or industrial drainage, or other facilities that may have an impact on water quality, adjacent land use and major physical contour, highways, etc. The extent of the watershed to be mapped should be based upon knowledge of the characteristics of the watershed. All potential sources of pollution and wastewater discharge points must be shown on the map.
(B) Plot Map. A map drawn to scale, showing bathing beach location, dimensions, contours, existing land use and wastewater discharge points within 10,000 feet of the proposed beach unless otherwise required by the Department.
(C) Water Level. Seasonal or anticipated water level variation. If auxiliary water to augment low flow is planned, source, location and flowrate shall be described.
(D) Sources of Contamination. Evaluation of:
(i) type and size of existing and potential sources of contamination, volume, occurrence and concentration level of materials in the effluent that may be of potential hazard to the bathers, and
(ii) the potential for additional contamination after a significant rainfall event.
(E) Weather and Topographical Influences. Prevailing wind direction during the bathing season, rainfall, topography, or environmental factors including current measurements.
(F) Water Quality. A history of the bacteriological quality, pH, and the turbidity of the proposed body of water shall be researched from all possible sources. The results of at least one set of representative bacterial samples, each week for a period of eight weeks shall be included. Eight sets of samples shall include at least one set after heavy rains consisting of daily samples for a five-day period.
(G) Physical and Chemical. The physical and chemical quality of bathing water, including color, odor, floatable debris, oils and greases, high turbidity and other substances that can potentially present a public health threat. Except at ocean beaches, it shall be possible to see an eight inch black-and-white disk in four feet of water. Clarity tests should be performed at four-foot depth in the bathing area at a minimum of three different locations. A map depicting test locations, dates of sampling, and current conditions should be submitted.
(H) Biological. The biological quality of the bathing water, including vegetation types, infectious snails, bird nesting areas, and poisonous or dangerous aquatic organisms.
(I) Fishing, Boating and Canoeing. Location and level of boat traffic, number of vessels with marine sanitation devices, marinas or boat dockage areas, and any canoeing activity or fishing.
(2) Bathymetry. Bathing area boundaries, bottom slopes and material including high and low tide lines, and depth lines at mean high tide on a 5-foot contour.
(3) Emergency Services. Location relative to service facilities, such as medical, fire and police protection and communication.
(4) Capacity. Maximum and average bathing loads.
(5) Any other information that may impact the health or safety of bathers.
(d) Certification. Prior to operation of a new facility or equipment, the applicant must submit to the Department a construction compliance certificate prepared and signed by a professional engineer or architect licensed to practice in New York State. This certificate must include a written statement that the bathing beach and the building(s) and all appurtenances have been constructed in accordance with plans and specifications approved by the Department.
(e) Construction Compliance Inspection. The applicant shall notify the Department of the completion of construction, modification, alteration or addition in order to schedule a required compliance inspection. Approval for a construction compliance inspection will be granted when all of the required items are completed to the Department's satisfaction.
(f) Permit Conditions. Approval certificates or permits from other permit issuing agencies, if applicable or required by the Department.
§ 167.09. Enforcement
(a) Public Health Hazards and Closing Criteria. Where a public health hazard condition exists, including one or more of the following, and said hazard(s) is(are) not immediately corrected, the bathing beach may be immediately closed in whole or in part by the Department and shall remain closed until such conditions are corrected to the satisfaction of the Department and in accordance with the provisions of this Article. The bathing beach in whole or in part shall remain closed until the Department has authorized reopening. Public health hazards shall include, but not be limited to, any of the following:
(1) Failure to provide adequate supervision of the beach as prescribed in 24 RCNY Health Code § 167.19;
(2) Failure to provide all lifesaving and safety equipment as prescribed in 24 RCNY Health Code § 167.21;
(3) Water quality inadequate as specified in 24 RCNY Health Code § 167.17(c);
(4) Failure to post public notification signs or advisories as prescribed in 24 RCNY Health Code § 167.27 indicating a potential health hazard or hazardous conditions, when water quality exceeds prescribed standards, in the event of sewage spills and pollution events, or when medical waste/hazardous materials are observed;
(5) Failure to provide adequate signs indicating that swimming and bathing are prohibited when lifeguards are not on active duty as prescribed in 24 RCNY Health Code § 167.19(a)(4), or when the bathing beach is closed;
(6) Medical waste, sewage, petroleum or other hazardous materials observed in beach area as prescribed in 24 RCNY Health Code § 167.13(a)(2);
(7) Use of unapproved or contaminated water supply sources for potable water use as prescribed in 24 RCNY Health Code § 167.31(f);
(8) Overhead electrical wire within 20 feet horizontally of the bathing beach as prescribed in 24 RCNY Health Code § 167.37(g)(2);
(9) Operating a bathing beach without a valid permit issued by the Department as prescribed in 24 RCNY Health Code § 167.05(a), (c);
(10) Operating without an approved Beach Safety Plan as prescribed in 24 RCNY Health Code § 167.23(a);
(11) Failure to provide depth markings, safety lines and diving requirements as prescribed in 24 RCNY Health Code § 167.29(b)(4), (5);
(12) Failure to provide appropriate safety and warning signs as prescribed in 24 RCNY Health Code § 167.37(f)(1), (f)(2)(B), (C); and,
(13) Any other condition determined to be a public health hazard by the Department.
(b) Inspection availability. The most recent inspection report shall be available at the facility at all times and shall be presented for inspection upon request by the Department.
§ 167.11. Modification by Department
When the Department determines that the strict application of any provision of this Article presents practical difficulties, the Commissioner or their designee may, in a specific instance, modify the application of such provision consistent with the general purpose of this Article and upon such condition(s) the Department deems necessary to protect life and health. Failure to comply with the terms of a modification may render such modification null and void and result in enforcement by the Department. The denial of a request for modification by the Commissioner shall be deemed a final agency determination.
(Amended City Record 6/13/2025, eff. 7/13/2025)
§ 167.13. Water Quality Standards
(a) All bathing beaches shall meet the following water quality standards:
(1) Bacteriological. The water quality in a bathing beach shall be determined through the collection and analysis of water samples for the presence of Enterococci and/or E. coli bacteria using the Standard Methods for the determination of Enterococci bacteria and E. coli approved for bathing beaches. The bacteriological water quality of bathing beaches shall meet the following standards:
(A) For marine water beaches Enterococci geometric mean shall not exceed 35 per 100 ml for a series of five or more samples collected during a 30-day period.
(B) For freshwater beaches Enterococci geometric mean shall not exceed 33 per 100 ml for a series of five or more samples collected during a 30-day period. -OR- E. coli geometric mean shall not exceed 126 per 100 ml for a series of five or more samples collected during a 30-day period.
(2) Chemical and Physical Quality. The water shall be free of deposits, floatable debris, growths, oils and greases, or any foreign substances that may potentially present a public health threat. The water in bathing beaches shall be considered to exceed the chemical and/or physical quality standards when the Department determines that any substance is being discharged or may be discharged into the water that is or may be hazardous to the health of persons using the bathing beach.
(b) Preemptive Standards – New York City Wet Weather Advisory. The bathing beach operator shall post public notifications as prescribed in 24 RCNY Health Code § 167.27(a).
§ 167.15. Monitoring
(a) Collection of samples and analysis for the purpose of surveillance or design shall be performed in accordance with the sampling plan specified by the Department. The sampling procedures will be based on potential pollution sources, storm water discharges, historical water quality data, regional hydrodynamics, beach usage, beach length, and geomorphology for representation of water quality monitoring.
(b) Laboratory Analysis. Bathing beach samples shall be examined by a laboratory in possession of a valid current New York State Department of Health National Environmental Laboratory Accreditation Certification (NELAC) using approved methods in accordance with City, state, and federal agencies.
(c) Preemptive Standards – New York City Wet Weather Advisory. For bathing beaches covered under this advisory, the operator shall be knowledgeable of the established wet weather rainfall intensity standards set for the facility. The operator shall monitor rainfall intensity/data on a daily basis during the bathing season.
§ 167.17. Classifications
The Department shall assign to each bathing beach one of the classifications listed below based on the evaluation and evidence of information provided by water quality data, sanitary and safety survey, site condition or historical information.
(a) Class A: Open for Swimming and Bathing. All of the following conditions shall be considered in order for a beach to be classified as open and approved for swimming and bathing:
(1) Bathing beach water quality standards are in accordance with 24 RCNY Health Code § 167.13.
(2) Sanitary and safety surveys conducted pursuant to 24 RCNY Health Code § 167.25 are satisfactory to the Department; and
(3) The epidemiological history is satisfactory to the Department. No repeated complaints/reports of illness/injury received from the public or from owners/operators of bathing beaches.
(b) Class B: Under Advisory – Not Recommended for Swimming and Bathing. When any of the following conditions is present, a bathing beach/facility shall be under advisory, notifying the public of the likelihood of polluted water and recommending that the public avoid swimming in the water to prevent contracting a swimming related illness:
(1) Rainfall intensities exceed the preemptive standards/threshold of New York City Wet Weather Advisories, as issued by the Department before each bathing season.
(2) A sanitary and safety survey or investigation reveals the presence of floatable debris, medical/infectious waste, toxic contaminants, petroleum products and/or other contamination on the beach or evidence of sewage and wastewater discharge, which may constitute a potential public health hazard.
(c) Class C: Closed – Temporarily Restricted for Swimming and Bathing. When one or a combination of any of the following conditions exist, the beach may be closed for bathing.
(1) Water quality standards exceed the standards set forth in 24 RCNY Health Code § 167.13; or
(2) Epidemiological data indicates a significant incidence of related illnesses or repeated complaints/reports of illness/injury received from beach patrons; or
(3) Sanitary and Safety Survey/Investigation: A sanitary and safety survey or an investigation reveals the presence of floatable debris, medical/infectious waste, toxic contaminants, petroleum products or other contamination on the beach, or there is evidence of sewage and wastewater discharge in sufficient quantities that will adversely affect the quality of the beach water; or
(4) Presence of public health hazards as illustrated in 24 RCNY Health Code § 167.09. If a bathing beach is closed due to unsatisfactory water quality sampling data, the beach shall remain closed to the public until appropriate sampling shows that the water quality meets the standards prescribed in 24 RCNY Health Code § 167.13(a). When a bathing beach is closed pursuant to 24 RCNY Health Code § 167.17(c), no one shall be allowed in the water and the beach must not be reopened without the express written permission of the Department. If a beach operator temporarily closes a beach voluntarily, the operator may reopen the beach when the conditions that led to the closing have been corrected.
§ 167.19. Supervision and Certification
(a) Supervision. Aquatic Supervisory Staff defined under 24 RCNY Health Code § 167.19(c) shall be on duty at the waterside at all times when a bathing beach is used by the bather(s) and shall provide continuous visual supervision and surveillance of the bathers in their assigned or designated area of coverage, without interference or interruption of his/her duties unless additional qualified staff is provided. The staff shall not be subject to duties that will divert their attention from the safety of the bather(s), or that will prevent immediate assistance to persons in distress in the water.
(1) Minimum Supervision Requirement. At least one aquatic supervisory staff person having at least the required supervisory level required under 24 RCNY Health Code § 169.19(c) shall be provided at all times for continuous visual surveillance for each 50 yards of beachfront or fraction thereof. Sufficient aquatic supervisory staff must be provided for visual surveillance of the entire bathing area(s) open for swimming or bathing.
(2) Additional Supervision. The Department may require additional aquatic supervisory staff whenever it is necessary for the protection of the bathers. Factors for additional aquatic supervision requirement may include, but are not limited to: bather loads, currents, tides, and any other conditions which may cause changes in water conditions; size and configuration of beach shape; diving board use; and other bather activities.
(3) Area without Supervision. Legible signs stating "No Swimming or Bathing" must be posted at areas not permitted/approved for bathing on property adjoining the designated bathing area that is owned or under control of the permit holder.
(4) Lifeguard Not on Duty. When no lifeguard is on duty at a beach, legible signs stating "No Lifeguard on Duty – Bathing and Swimming Prohibited", or language to that effect, shall be posted at every entrance to the bathing area. The sign must be at least 36" × 24" in size, with letters at least two inches high.
(b) Operator. All bathing beach and beach facilities shall be maintained and supervised by a responsible person who, as the operator, shall maintain the beach in compliance with the provisions of this Article. The operator of the bathing facility shall be accountable for, but not be limited to, the following responsibilities:
(1) Controlling decorum and activities at the bathing site;
(2) Hiring and retaining adequate and qualified supervisory personnel;
(3) Reporting injuries and deaths to the Department;
(4) Public notification for potential contamination, confirmed contamination or public health hazards;
(5) Monitoring weather, and other environmental conditions, that impact the beach; and
(6) Maintaining the physical facilities as required by this Article.
(c) Certifications. All bathing beaches shall be supervised by the required certified personnel. Copies of certificates or other documents showing possession of such qualifications shall be kept at the facility at all times and shall be presented for inspection by the Department upon request.
(1) Lifeguards. Appropriately certified lifeguards shall be present whenever the beach is open. A minimum of one supervising lifeguard is required for bathing beaches that require three or more lifeguards. The lifeguard shall meet the following minimum requirements:
(A) Ocean Surf Beach: Supervision Level I – Surf Lifeguards
(i) Shall be at least 16 years old; and
(ii) Shall possess a current American Red Cross Basic Life Support for the Professional Rescuer Cardiopulmonary Resuscitation ("CPR") certificate or American Heart Association Course "C" CPR certificate, or an equivalent certificate approved by the New York State Department of Health. Certification period must not exceed one year; and
(iii) Must possess a current Municipal Lifeguard Certification, or accepted equivalent certificate having successfully completed a minimum 20-hour (24-hour if first aid skills are included) surf lifeguard training courses acceptable to The New York State Department of Health. All training and ocean testing must be satisfactorily completed prior to assignment at ocean front. The certification period must not exceed three years.
(B) Non-Surf Beach: Supervision Level IIb – Beach Lifeguard
(i) Shall be at least 16 years old (or 15 years old if supervisory lifeguard is present); and
(ii) Shall possess a current American Red Cross Basic Life Support for the Professional Rescuer CPR certificate or American Heart Association Course "C" CPR certificate, or an equivalent certificate approved by the New York State Department of Health. Certification period must not exceed one year; and
(iii) Shall successfully complete a minimum 20-hour (24-hour if first aid skills are included) lifeguard training course (including a beach module) acceptable to the New York State Department of Health and possess a current certificate thereof. Certification period must not exceed three years.
(C) Supervision Level III
(i) Shall be at least 18 years old (or 16 years old if certified as Level II Lifeguard);
(ii) Shall possess a current American Red Cross Community – CPR certificate, or equivalent approved by the New York State Department of Health. Certification period shall not exceed one year; and
(iii) Shall be competent to:
(a) understand and apply the rules and regulations of this Article and implement the safety plan;
(b) evaluate environmental hazards;
(c) use lifesaving equipment; and
(d) undertake bather/crowd control.
(D) Supervising Lifeguard. Beaches that require Supervision Levels I and IIb aquatic supervisory staff shall provide a supervising lifeguard when the facility is required to provide three or more aquatic supervisory staff.
(i) Shall have the lifeguard qualifications specified in 24 RCNY Health Code § 167.19(c)(1)(A) for Ocean Surf Beach or 24 RCNY Health Code § 167.19(c)(1)(B) for Non-Surf Beach, as appropriate for the beach; and
(ii) Shall have at least two seasons of adequate lifeguard experience.
§ 167.21. Lifesaving and Safety Equipment
(a) Lifesaving equipment shall be kept in good repair, have its function plainly marked, be kept in ready-to-use condition, and be readily accessible at bathing beaches at all times. At a minimum, the following equipment shall be maintained at all times:
(1) One rescue tube or torpedo buoy with attached line and a pocket face mask or face shield with a one way valve to assist with CPR for each lifeguard required by this Article, and
(2) One rescue board or lifeboat including sterned lifeboat, a catamaran surfboat or other suitable surfboat. The lifeboat or surfboat shall have hanging ropes on each side so that bathers may readily hold on and obtain support. The lifeboat or surfboat shall also be equipped with at least one ring buoy or life preserver with 60 feet or 18 meters of line attached, and
(3) One spine board, minimum of 6 feet long and 16 inches wide, provided with straps and head immobilizater to aid immobilization of victim, and 10 handholds, and
(4) One First Aid kit, which may be any commercially prepared 24-unit kit, or a supply of bandaids, bandage compresses and self-adhesive bandages.
(b) At least one set of the items listed in (2), (3) and (4) above shall be provided for each 500 feet of beachfront or fraction thereof, or as specified in the approved Beach Safety Plan, and shall be readily accessible to the lifeguards therein.
(c) Lifeguard Station
(1) Elevated Chair. There should be one elevated lifeguard chair for each 50 yards of beach front, or at locations provided in the approved safety plan. Elevated lifeguard chairs or towers shall be high enough to provide a completely unobstructed view of the bathing area under surveillance.
(2) Lifeguard Apparatus. Each lifeguard chair shall be equipped with a whistle or megaphone, and an umbrella or sunshade.
(d) Telephone and Emergency Contact List. A telephone, radio, or other suitable means of communication shall be readily accessible to the lifeguards for emergency communications at the bathing beach. A telephone list of local police, emergency medical services, nearest hospital and other entities shall be posted in a conspicuous place. At beaches with multiple lifeguard chairs, at least one radio and telephone shall be readily available from a lifeguard station building.
(e) Emergency Care/First Aid Room. Every bathing beach capable of accommodating 500 bathers shall have a readily accessible room or area designated and equipped for emergency care. The room shall be equipped with at least the following:
(1) Running potable water;
(2) A cot or bed with blankets and sheets;
(3) Advanced first aid supplies at least equivalent to 24 units; and
(4) Resuscitation equipment.
§ 167.23. Beach Safety Plan
(a) The operator of a bathing beach shall develop, maintain, and implement a written Beach Safety Plan that consists of health and safety procedures to be followed by beach personnel during normal operations and in emergency situations. The plan shall include daily procedures and protocols for bather supervision, coverage and surveillance, responsibility and organization of all personnel, injury prevention, reacting to potential incidents, injuries and emergency situations, a list of emergency telephone numbers, location of first aid and rescue equipment, providing first aid and summoning help, and such other information, evidence, or documentation as the Department may require. The safety plan must be approved by the Department in writing before implementation. The safety plan must be kept at the beach facility at all times and be presented for inspection by the Department upon request.
(b) Revisions. The owner, lessee or operator shall submit to the Department revisions to the Beach Safety Plan whenever a change occurs in the facility, or at the direction of the Department. Revisions to the Beach Safety Plan shall not be implemented without written approval from the Department.
§ 167.25. Sanitary and Safety Survey
Prior to opening the bathing beach for operation, the operator or aquatic supervisory staff shall conduct a daily sanitary and safety survey. A sanitary and safety survey shall include, but not be limited to, a visual inspection for untreated sewage discharge, petroleum oil slick, floatable debris, medical/infectious materials or other sources of contamination as per 24 RCNY Health Code § 167.13(a)(2). All refuse (especially items such as syringes and medical refuse), garbage, and debris left on the beach or floating nearby, shall be removed and disposed of properly. The waterfront area of the beach shall be free of potholes, loose rocks, debris, glass containers, and other dangerous objects. If pollution which may potentially present a public health threat is observed, as described in 24 RCNY Health Code § 167.13(a)(2), the operator shall close the beach immediately and notify the Department for further instructions.
§ 167.27. Public Notification
Bathing beach operators shall notify bathers of potential contamination, confirmed contamination, or public health hazards, as classified in 24 RCNY Health Code § 167.17(b) and (c), by posting signs as prescribed by the Department in a conspicuous and visible place. Signs shall be posted by the bathing beach facility in areas visible to bathers including, but not limited to, beach entrances, bulletin boards, or in the general vicinity of the common bathing areas.
(a) Class B: Under Advisory – Not Recommended For Swimming and Bathing.
(1) Preemptive Standards – New York City Wet Weather Advisory. The bathing beaches covered under the Wet Weather Advisories, as defined under 24 RCNY Health Code § 167.03(n), shall post a "permanent" advisory at their beach operation, in an area visible and accessible to the public, during the entire bathing season, notifying the public of possible water quality standard exceedances and the potential of contracting bathing related illnesses. The operator is responsible for monitoring the rainfall intensities in the area. When the rainfall intensity exceeds the thresholds of the Preemptive Standards – New York City Wet Weather Advisories, as issued by the Department, the operator shall post additional signs approved by the Department indicating that the Wet Weather Advisory is in effect until the required time period has elapsed.
(2) Preemptive Swimming and Bathing Advisory. The operator is responsible for posting signs indicating a Preemptive Swimming and Bathing Advisory when instructed by the Department. The sign must be posted and maintained until further notice from the Department.
(b) Class C: Closed – Temporarily Restricted for Swimming and Bathing.
(1) The bathing beach shall be closed for swimming and bathing by the operator when notified by the Department and must remain closed until the Department authorizes reopening. The operator is responsible for restricting bathers from entering the water and for posting beach closure signs as required by the Department.
(2) If the operator or any aquatic supervisory staff on duty determines that adverse weather or other environmental conditions pose a threat to the health and safety of the public, the operator must close the beach and beach closure signs must be posted.
§ 167.29. Control of Beach and Water Use
(a) Each bathing beach shall be under the supervision of a competent operator who shall require the careful observance of sanitary regulations prescribed in this Article and the requirements of the permit issued for such bathing beach.
(b) Waterfront Use.
(1) Bather Loading. The number of bathers permitted in the bathing water of a bathing beach shall not exceed the maximum permissible loading established by 24 RCNY Health Code § 167.37(c). The operator shall be responsible for restricting usage so that the maximum capacity is not exceeded.
(2) Surrounding Property. All areas of an owner's, lessee's, or operator's property that are adjacent to the designated beach and are accessible to the public for entry into the water for bathing shall be supervised or patrolled during hours of operation. Bathing is prohibited in areas where there is not lifeguard supervision.
(3) Safety Signs or Public Advisory. Signs to be posted shall be maintained and posted conspicuously in manner consistent with the requirements of this Article.
(4) Depth markings and safety lines shall be provided and maintained in accordance with the provisions of 24 RCNY Health Code § 167.37(e) and be clearly visible and readable.
(5) Diving. Diving shall not be permitted unless minimum depths in accordance with provisions contained in 24 RCNY Health Code § 167.37(d)(2) are provided.
(6) Bathing at 150 feet or more from shore is prohibited.
(7) Motorized Vehicle. No motorized vehicles shall be permitted on the beach, except emergency and maintenance vehicles operated by the aquatic supervisory staff, lifeguards, or operators.
(8) Water Sports. No boating, water skiing, fishing, scuba diving, or surfboarding shall be permitted in a bathing area when bathing is allowed. Floating lines, buoys, or signs may designate separate areas for the above activities.
(9) Swimming and bathing are prohibited outside of established hours, at night, during lightning or a thunderstorm, or in dangerous or unauthorized areas.
(10) Fishing. Where allowed at a bathing beach during bathing season, fishing shall be permitted only in areas where bathing has been temporarily prohibited.
(11) Electrical Devices. All plug-in electrical devices, such as portable announcing systems and radios, are prohibited within 20 feet of the water.
(12) Glass. Glass containers shall not be permitted on the beach.
(13) Refuse. During bathing season, all refuse, garbage and debris, whether water borne or produced in connection with the normal operation of the bathing beach, must be removed, stored, and disposed of in a sanitary manner to prevent harborage of rodents, insect attraction or breeding, odors, public health hazards, and environmental pollution.
§ 167.31. Facility Use and Maintenance
(a) All bathing beach facilities shall be properly lighted, ventilated, and maintained and operated in a safe, clean, and sanitary condition at all times. The floors, fixtures, showers, and toilets shall be kept clean, free of dirt and debris, and in good condition. Floors shall be maintained in a slip-resistant condition. A supply of toilet paper shall be provided at each toilet at all times.
(b) Toilet. Toilet and shower facilities shall be provided and maintained at all bathing beaches in accordance with 24 RCNY Health Code § 167.39.
(c) Hosing. A minimum length of 50 feet of hosing shall be provided and available within the bathhouse to flush the entire area. Vacuum breakers shall be attached to all hose bibbs.
(d) Lavatories. All lavatories shall be provided with liquid soap in an acceptable dispenser, paper towels or other individual towels or electrical hand-drying units, and a covered waste receptacle. Common use of bar soap or cloth towels shall not be permitted.
(e) Structural Condition. Walls and floors of the bathing beach facility shall be free from cracks or open joints. The floors must be well drained.
(f) Drinking Water. Water supply serving all plumbing fixtures, including drinking fountains, lavatories and showers, shall use the City water supply or shall meet the applicable drinking water quality standards for all sources of water supply in New York state. All facilities shall be provided with drinking water through a drinking fountain or served by disposable single-service drinking cups.
§ 167.33. Drowning, Injury and Illness Incidents
(a) 24-Hour Notification. In the event of a drowning, injury or illness in a bathing beach, bathing beach facility, or within the confines of the bathing beach, the owner, lessee, or operator shall notify the Department within 24 hours of occurrence whenever an incident occurs that:
(1) Results in death;
(2) Requires resuscitation;
(3) Requires referral to a hospital or other facility for medical attention; or
(4) Involves illnesses associated with the water quality;
(b) Reporting. In the event of an incident referred to in subsection (a) of this section, the owner, lessee, or operator shall submit to the Department a written incident report within seven days. The incident report shall be recorded in the log book and shall include:
(1) Name of the lifeguards, supervisor staff or operator;
(2) The date, time, exact location and type of incident;
(3) Cause of the injuries;
(4) The extent of injuries, if any;
(5) Actions taken by persons at the site;
(6) Witnesses statements; and
(7) Lifesaving and safety equipment used, if any.
§ 167.35. Record Keeping
The operator shall keep and maintain a log book of daily bathers using the beach, number of lifeguards on duty, weather conditions, water clarity, results of any water quality laboratory results and reports, and any reported rescues, injuries and illnesses. Copies of records shall be submitted to the Department on a monthly basis. The records shall be maintained at the facility for 12 months.
§ 167.37. General Requirements
(a) All bathing beaches shall be designed and constructed in accordance with the requirements contained in this Code. These standards are applicable to the design of new or modified bathing beaches regulated by this Article. The designing architect or engineer shall certify the structural stability and safety of the facility.
(b) Pre-Qualifications for Proposed Beach. A proposed bathing beach shall meet the following pre-qualification requirements for establishing a beach:
(1) Site Assessment. A satisfactory approval by the Department for site assessment contained in 24 RCNY Health Code § 167.07(c);
(2) Water Surface Area. The water surface where the beach is to be developed shall be at least one acre. In the event that the area is less than four acres with natural flow-through below 100 gallons per bather per day, a source of dilution water of at least 100 gallons per bather per day must be provided in accordance to the water quality requirements prescribed in 24 RCNY Health Code § 167.13;
(3) Land Area. At least 35 square feet of land area per bather shall be provided;
(4) Bottom Slope. For depths up to four feet, the slope shall be uniform and not exceed 1:10 for greater depths, the slope should not exceed 1:3;
(5) Bottom Material. The bottom up to a water depth of six feet shall consist of sand, pea gravel or other similar material;
(6) Sewage Discharge. Wastewater discharges from sewage treatment plants, combined sewers or other sources shall be prohibited within 750 feet of the bathing beach;
(7) Water Currents. Water currents in the bathing area shall not exceed three feet per second; and
(8) Water Quality. Bathing beaches shall meet the water quality standards for bacteriological, physical and chemical quality contained in 24 RCNY Health Code § 167.13.
(c) Maximum Permissible Loading. Maximum Bathers. The maximum number of bathers permitted in the shallow water (four feet or less) of a bathing beach shall not exceed one bather per 25 square feet of water surface. In areas of water depth greater than four feet, at least 75 square feet per bather shall be provided.
(d) Diving.
(1) Diving Platforms. Floating diving piers and fixed platforms shall be constructed with a visible 12-inch air space under maximum feasible load. There shall be as little underwater construction as is consistent with adequate support. All braces and struts shall be designed to prevent entrapment of bathers. For solid flotation devices such as foam blocks, no air space is required.
(2) Depth. Diving from rafts, piers or other platforms shall be prohibited, unless a minimum water depth at mean low tide of eight feet is provided and maintained for a distance of at least 10 feet forward of the diving direction. For a diving board or other device three or less feet above the water, the depth at the end of it, and for 12 feet beyond it, shall be 10 feet. For heights above water greater than three feet, the depth at those locations shall be 12 feet and 20 feet beyond it. No diving device more than 10 feet above water shall be installed.
(e) Depth Markers and Safety. Except ocean beaches, marker lines with buoys shall be provided at all beaches to designate the perimeter, the shallow and deep-end areas at a depth of three to four feet, the diving area, drop-offs, and radical changes in slopes or underwater obstructions. A separate wading area up to two feet deep, designated by lines, shall be provided. Lines shall have floats at five-foot intervals and be securely anchored, and have buoys no more than 25 feet apart and at point where lines are joined.
(f) Safety and Warning Signs.
(1) "No Diving" Markers. Clearly visible depth markers shall be provided at all the diving boards, platforms piers, floats and similar facilities, together with warning signs indicating "No Diving" where depth is less than eight feet.
(2) Warning Signs. A sign or signs shall be securely posted in a conspicuous place or places at the bathing facility and shall provide the following information:
(A) Maximum number of persons permitted at the bathing beach at any time;
(B) The hours during which public bathing is allowed, and that entry into water at other times is prohibited; and
(C) Beach Closed. "No Swimming and Bathing" signs shall be placed up in areas adjacent to the beach but not open for swimming and bathing, and on the beach during the closed season.
(g) Electrical Requirements.
(1) All electrical wiring shall conform to Chapter 3 of Title 27 of the Administrative Code of the City of New York, entitled the "Electrical Code" and the National Electrical Code of the National Fire Protection Association, or any successor regulation or code.
(2) Overhead Clearance. No overhead electrical wiring, including lights, or plug-in electrical devices, such as portable announcing systems and radios, shall pass within 20 feet horizontally of the bathing beach high water line.
(h) Safety Equipment. The bathing beach shall provide the lifesaving and safety equipment identified in 24 RCNY Health Code § 167.21(a), (b) and (c).
(j) Emergency Care/First Aid Room. Every bathing beach capable of accommodating 500 bathers shall have a readily accessible room or area designated and equipped for emergency care. The room shall contain the equipment identified in 24 RCNY Health Code § 167.21(d).
§ 167.39. Bathhouses
(a) Materials. Floors of the facility shall be of smooth-finished material with non-slip surfaces, impervious to moisture, cleanable and sloped at least one-fourth inch per foot to drains. Carpeting shall not be permitted in shower and toilet areas or other areas receiving bathers. Junctions between walls and floors shall be coved. Walls and partitions shall be of smooth, impervious materials, free from cracks or open joints. Partitions between dressing cubicles shall maintain at least 10 inches of open space from the floor or shall be placed on continuous raised masonry or concrete bases at least four inches high or on legs with bottom of locker at least 10 inches above the floor.
(b) Toilets, Washbasins and Showers. All bathing beach facilities shall be provided with an adequate number of toilets and handwashing facilities.
(1) A facility shall provide properly lighted, ventilated and maintained toilets and handwashing sinks and an adequate number of showers or a dressing facility containing toilets and showers.
(2) Separate toilet facilities shall be provided for each sex. All toilet facilities shall be provided with soap, paper towels or electrical hand drying units, and covered waste receptacles. Suitable sanitary napkin receptacles shall be provided in toilet facilities used by females.
(3) Where showers are provided, they shall be supplied with water at a temperature of at least 90 degrees Fahrenheit and no more than 110 degrees Fahrenheit at a rate of at least 1.5 gallons per minute per showerhead. Thermostatic, tempering or mixing valves shall be kept in good operation to prevent scalding of bathers.
(c) Drinking Water Fountains. Where drinking fountains are provided, at least one drinking fountain for each 500 feet distance or for every 1,000 users shall be provided.
(1) Fountains shall be of slanting jet type with surrounding guard and non-submersible opening.
(2) Fountains shall be supplied with a minimum water pressure of 20 pounds per square inch.
(d) Suits and Towels. Where swimming suits and/or towels are provided, these items shall be properly stored and sanitized.
(e) Lockers. Lockers, where provided, shall be constructed on solid masonry or concrete bases at least four inches high or on legs with bottom of lockers 10 inches above the floor. Lockers shall be vented.
§ 173.01. Definitions
When used in this article the following terms shall have the following meanings:
(a) Advertisement means all representations disseminated in any manner or by any means, other than by labeling, for the purpose of inducing, or which are likely to induce, directly or indirectly, the purchase or use of a hazardous substance.
(b) Art material means any substance marketed or represented by the producer or repackager as suitable for use in any phase of the creation of any work of visual or graphic art of any medium. The term does not include substances subject to the Federal Insecticide, Fungicide, and Rodenticide Act, as amended, or drugs, devices, or cosmetics subject to 24 RCNY Health Code Article 71.
(c) Combustible means having a flashpoint at or above 100 degrees Fahrenheit (37.8 degrees Celsius) to and including 150 degrees Fahrenheit (65.6 degrees Celsius) as determined by the test method described at 16 C.F.R. § 1500.43a or successor regulation.
(d) Corrosive means capable of causing destruction of living tissue by chemical action when placed in contact with such tissue but shall not refer to action on inanimate surfaces.
(e) Electrical hazard means an article that in normal use or when subjected to reasonably foreseeable damage or abuse may cause personal injury or illness by electric shock due to its design or manufacture.
(f) Extremely flammable means that a substance has a flashpoint at or below 20 degrees Fahrenheit (-6.7 degrees Celsius) as determined by the test method described at 16 C.F.R. § 1500.43a, or successor regulation.
(g) Flammable means that a substance has a flashpoint above 20 degrees Fahrenheit (-6.7 degrees Celsius) and below 100 degrees Fahrenheit (37.8 degrees Celsius), as determined by the method described at 16 C.F.R. § 1500.43a or successor regulation.
(h) Flashpoint means the lowest temperature of a product at standard conditions at which the product's vapors will ignite momentarily when subjected to a flame. Flashpoint temperatures shall be determined pursuant to the procedures set forth in 16 C.F.R. § 1500.43a or successor regulations.
(i) Hazardous substance means:
(1) Any substance or mixture of substances that is combustible, corrosive, extremely flammable, flammable, highly toxic, an irritant, a strong sensitizer, toxic, or generates pressure through decomposition, heat, or other means, if such substance or mixture of substances may cause or has caused substantial personal injury, including developmental delay or cognitive impairment, or substantial illness during or as a proximate result of any customary or reasonably foreseeable handling or use, including reasonably foreseeable ingestion by children;
(2) Any substance that the Federal Consumer Product Safety Commission determines is hazardous;
(3) Any radioactive substance if, with respect to such substance as used in a particular class of article or as packaged the Federal Consumer Product Safety Commission determines by regulation that the substance is sufficiently hazardous to require labeling to protect the public health;
(4) Any toy or other article which the Federal Consumer Product Safety Commission or the Commissioner determines presents an electrical hazard, mechanical hazard, or thermal hazard; and
(5) Any substance or product that contains a concentration or amount of lead that may cause or has caused substantial personal injury, including developmental delay or cognitive impairment, or substantial illness during or as a proximate result of any customary or reasonably foreseeable handling or use, including reasonably foreseeable ingestion by children. Such products include, but are not limited to:
(A) Jewelry that is found to contain more than 100 parts per million of total lead content in accessible parts or a concentration of lead greater than 0.009 percent (90 parts per million) in paint or any similar surface coatings; and
(B) Ceramic ware that is not suitable for use with foods because it leaches significant quantities of lead from potential food contact surfaces, as described by U.S. Food and Drug Administration Compliance Policy Guide Sections 545.450 and 545.500. The lead leaching limits for acceptable ceramic ware for use with foods is:
Product Micrograms per milliliter limit Ceramic ware: Flatware (average of 6 units) 3.0 Small hollowware other than cups and mugs (any 1 of 6 units) 2.0 Large hollowware other than pitchers (any 1 of 6 units) 1.0 Cups and mugs (any 1 of 6 units) 0.5 Pitchers (any 1 of 6 units) 0.5 Silver-plated hollow ware: Product intended for use by adults (average of 6 units) 7 Product intended for use by infants and children (any 1 of 6 units) 0.5
(6) Hazardous substance shall not mean pesticides subject to the Federal Insecticide, Fungicide, and Rodenticide Act or State Environmental Conservation Law; substances intended for use as fuels when stored in containers and used in the heating, cooking, or refrigeration system of a house; and source material, special nuclear material, or byproduct materials defined and regulated in applicable federal, state and local law.
(j) Highly toxic means any substance which falls within the definition or description set forth in 16 C.F.R. § 1500.3 or successor regulation. If, pursuant to 16 C.F.R. § 1500.4 or successor regulation, available data on human experience with any substance indicates results different from those obtained on animals in the dosages and concentrations specified, human data shall take precedence.
(k) Human experience or data shall mean a report or evidence of exposure of one or more persons to a hazardous substance resulting in an adverse effect.
(l) Irritant means a substance that is not corrosive which on immediate, prolonged or repeated contact with normal living tissue will induce a local inflammatory reaction.
(m) Label or labeling means a display of written, printed, or graphic matter upon the immediate container of any hazardous substance or, in the cases of an article which is unpackaged or is not packaged in an immediate container intended or suitable for delivery to the ultimate consumer, a display of such matter directly upon the article involved or upon a tag or other suitable material affixed thereto. A requirement of federal, State or local law that any word, statement, or other information appear on the label shall not be considered to be complied with unless such word, statement, or other information also appears (i) on the outside container or wrapper, if any there be, unless it is easily legible through the outside container or wrapper and (ii) on all accompanying literature where there are directions for use, written or otherwise.
(n) Mechanical hazard means an article that in normal use or when subjected to reasonably foreseeable damage or abuse presents an unreasonable risk of personal injury or illness due to its design or manufacture:
(1) From fracture, fragmentation, or disassembly of the article;
(2) From propulsion of the article (or any part or accessory thereof);
(3) From points or other protrusions, surfaces, edges, openings, or closures;
(4) From moving parts;
(5) From lack or insufficiency of controls to reduce or stop motion;
(6) As a result of self-adhering characteristics of the article;
(7) Because the article (or any part or accessory thereof) may be aspirated or ingested; (8) Because of instability; or
(9) Because of any other aspect of the article's design or manufacture.
(o) Strong sensitizer means a substance that will cause a hypersensitivity-type reaction through an immunologically-mediated (allergic) response, including allergic photosensitivity, which offers a significant potential for causing injury and where the allergic reaction typically becomes evident upon reexposure to the same substance.
(p) Thermal hazard means an article or thing that in normal use or when subjected to reasonably foreseeable damage or abuse, presents an unreasonable risk of personal injury or illness because of heat as from heated parts, substances, or surfaces due to its design or manufacture.
(q) Toxic means a substance, other than a radioactive substance, that
(1) Has the capacity to produce personal injury or illness to man through ingestion, inhalation, or absorption through any body surface or any substance deemed to be toxic pursuant to the procedures as set forth in 16 C.F.R. § 1500.3 or successor regulation;.
(2) Is toxic (but not highly toxic) on the basis of human experience; or
(3) Presents a chronic hazard, if it is or contains a known or probable:
(A) Human carcinogen;
(B) Human neurotoxin; or
(C) Human developmental or reproductive toxicant.
(Amended City Record 6/19/2019, eff. 7/19/2019)
§ 173.03. Transfer of Hazardous Substances; Use of Food, Drug and Cosmetic Containers
(a) No person shall transfer a hazardous substance from one container to another without affixing to the new container the labeling required by this article.
(b) No person shall use, possess, hold for sale, sell, give away or leave in any place a hazardous substance in a container which, whether or not previously used as a food, drug or cosmetic container, bears a food, drug or cosmetic label or imprint, or reuse a container which may be mistaken for a food, drug or cosmetic container because of its characteristic shape, impression or closure.