24 RCNY New York City Health Code part 9 of 13
§ 173.05 to § 175.10: 25 sections.
§ 173.05. Labeling
(a) Label required. No person shall sell, hold for sale, transport, or give away a hazardous substance unless the labeling complies with this article. When a hazardous substance is labeled in compliance with applicable State or Federal law, this section shall not apply, except that if the Commissioner finds that the labeling of the substance is inadequate to protect the public health, the labeling of the substance shall, upon the order of the Commissioner and written notice to the manufacturer or distributor, contain such additional matter as may be required by this section.
(b) Label contents. The label of a package or container of a hazardous substance shall bear the following information:
(1) The name and place of business of the manufacturer, packer, distributor or seller;
(2) The common or usual name, or if there is no common or usual name, the chemical name, or if there is no common or usual name and if the chemical name is unknown or complex, the recognized nonprotected name (not trade name only) of the hazardous substance or of each component which contributes substantially to its hazard, unless the United States Consumer Product Safety Commission by regulation permits or requires the use of a recognized generic name;
(3) The signal word "Danger," "Warning" or "Caution" to indicate the degree of hazard. The signal word "Danger" shall be used for substances which are extremely flammable, corrosive, or highly toxic. The signal word "Warning" or "Caution" shall be used for all other hazardous substances;
(4) An affirmative statement of the principal hazard or hazards of the substance such as "Flammable," "Extremely Flammable," "Vapor Harmful," "Causes Burns," "Absorbed through Skin" or similar words descriptive of the hazard;
(5) Precautionary measures describing the action to be followed or avoided;
(6) Instructions for first-aid treatment, if available;
(7) Instructions for handling or storage on packages or containers requiring special care in handling or storage;
(8) Instructions for final disposal of containers on retail packages or containers requiring special care in disposal; and,
(9) The statement "Keep Out of the Reach of Children" or its practical equivalent on retail packages or containers offered for household use.
(c) Poisons. In addition to the words, statements or other information required by subdivision (b) of this section, a hazardous substance shall bear on its label the word "Poison," a skull and crossbones symbol, directions to call a physician upon ingestion and, if available, an antidote, if such hazardous substance is highly toxic as defined in this Article.
(d) Art materials. All art materials shall be labeled in a manner as required pursuant to the Federal Hazardous Substances Act, as amended, and related regulations.
(e) Other substances to be labeled. When the Commissioner finds that any substance is dangerous or detrimental to the health and safety of the public, the Commissioner may require the substance to be labeled pursuant to subdivisions (b) or (c) of this section.
(e-1) Ceramic ware not suitable for use with food. All ceramic ware not suitable for use with foods must either:
(1) Bear two types of conspicuous warnings:
(A) A stick-on label on a surface clearly visible to consumers that states in legible font at least 3.2 mm (0.125 inches) in height one of the following messages:
(i) "Not for Food Use. May Poison Food,"
(ii) "Not for Food-Use. Glaze contains lead. Food Use May Result in Lead Poisoning," or
(iii) "Not for Food Use - Food Consumed from this Vessel [Plate] May be Harmful"; and
(B) A legible permanent statement of a message selected from the above paragraph molded or fired onto the exterior surface of the base or, when the ceramic ware is not fired after decoration, permanently painted legible font at least 3.2 mm (0.125 inches) in height onto the exterior surface of the base; or
(2) Bear the label described above in Subparagraph (A) of Paragraph (1) of this subdivision and have a hole bored through any potential food-contact surface.
(f) Strong sensitizers. When the Department determines that a substance is a strong sensitizer, it may order the manufacturer, distributor or seller to label the substance pursuant to subdivision (b) of this section.
(g) Experimental substances. Subdivisions (b) and (c) of this section shall not apply to a substance still in the development stage when it is used solely for experimental purposes and when it is known that no specific hazard exists but the potential hazard is not identified, if it bears the following label or its practical equivalent: "Important! The properties of this substance have not been fully investigated and its handling or use may be hazardous. Exercise due care."
(h) Wrapper labels. The words, statements or other information required by this article to be borne on the label or labeling of a hazardous substance shall also appear on the outside container or wrapper, if any, of the retail package of the substance, unless the required word, statement or other information is easily legible through the outside container or wrapper, and on each place of the labeling of a hazardous substance where there are directions for use, whether written or otherwise.
(i) Labeling to be conspicuous. All words, statements or other information required on the label or labeling shall appear in a prominent place in the English language and in conspicuous and legible type which is contrasted by typography, layout or color from other printed matter on the label, container or wrapper. If the label or labeling contains any representation in a foreign language, all words, statements or other information required to appear on the label, container or wrapper shall also appear thereon in the foreign language.
(Amended City Record 6/19/2019, eff. 7/19/2019)
§ 173.051. Exemptions. [Repealed]
BetaNYC's copy has no text for this section. Read 24 RCNY Health Code § 173.051 at American Legal Publishing.
§ 173.06. Pressurized Products. [Repealed]
BetaNYC's copy has no text for this section. Read 24 RCNY Health Code § 173.06 at American Legal Publishing.
§ 173.07. False or Misleading Advertising or Labeling
(a) No manufacturer, packer, distributor or seller of a hazardous substance shall disseminate or cause to be disseminated an advertisement concerning such hazardous substance that is false or misleading in regard to its safety or use.
(b) No person shall sell or hold for sale any hazardous substance the labeling of which is false or misleading in regard to its safety of use.
(c) In determining whether the labeling of, or an advertisement concerning, a hazardous substance is false or misleading, the Department shall consider the representations made or suggested by the label's statement, word, picture, design or emblem and the extent to which the labeling or advertisement fails to reveal material facts about the substance.
§ 173.08. Carbon Tetrachloride; Prohibited for Household Use and in Fire Extinguishers. [Repealed]
BetaNYC's copy has no text for this section. Read 24 RCNY Health Code § 173.08 at American Legal Publishing.
§ 173.09. Rodenticides and Insecticides. [Repealed]
BetaNYC's copy has no text for this section. Read 24 RCNY Health Code § 173.09 at American Legal Publishing.
§ 173.11. Fire Extinguishers Containing Methyl Bromide. [Repealed]
BetaNYC's copy has no text for this section. Read 24 RCNY Health Code § 173.11 at American Legal Publishing.
§ 173.13. Lead Paint
(a) (1) Lead-based paint prohibited. No person shall possess, sell, hold for sale or give away paint or other similar surface-coating material which is intended or packaged in a form suitable for use in or around the household or otherwise for consumer use within the meaning of 15 U.S.C. §§ 2057 et seq. and 16 C.F.R. Part 1303 or its successor regulations, containing more than 0.009 percent of metallic lead, based upon the total non-volatile content of the paint or other similar surface-coating material.
(2) Notice that dry sanding and scraping are prohibited. Any place where paint and paint removal products are sold, or where sanding equipment is sold or rented for use in the City of New York, shall prominently post, or otherwise distribute to purchasers and renters of paint removal and sanding equipment, a notice, in a form provided or approved by the Department, warning that dry sanding and scraping is prohibited as a method of removal of lead-based paint or paint of unknown lead content in any dwelling, day care center or school, and is a public nuisance pursuant to § 17-181 of the Administrative Code of the City of New York.
(3) Enforcement by Department of Consumer Affairs. The provisions of paragraph (2) of this subdivision may be enforced by agents and employees of the Department and the Department of Consumer Affairs, or successor agency. Any violation of paragraph (2) issued by the Department of Consumer Affairs may be adjudicated at any tribunal authorized to hear such agency's violations.
(4) Investigations. Whenever a report has been made to the Department of a child under 18 years of age with a blood lead level of three and a half (3.5) micrograms per deciliter or higher, the Department shall conduct such investigation as may be necessary to identify potential sources of the elevated blood lead level, including but not limited to, an inspection of the dwelling unit where such child resides and any supplemental address of that child.
(b) No person shall manufacture, sell, hold for sale, give away or leave toys, children's furniture or any other articles or things intended for use by children which have a paint or other similar surface-coating material containing more than 0.009 percent of metallic lead based on the total non-volatile content of the paint or other similar surface-coating material.
(c) No person shall use a paint or other similar surface-coating material containing more than 0.009 percent of metallic lead, based on the total non-volatile content of the paint or other similar surface-coating material on the interior or exterior surfaces of a dwelling. As used in this section, dwelling means any building or structure or portion thereof, including the property occupied by and appurtenant to such dwelling, which is occupied in whole or in part as the home, residence or sleeping place of one or more human beings. This subsection shall also apply to places where children reside, or are boarded, or where they receive regular care and/or education, such as child care services, schools and children's institutions.
(d) Orders for abatement or remediation.
(1) Generally. When the Department finds that there is lead-based paint, or lead-contaminated dust on the interior of any dwelling, supplemental address, or other premises, such premises including but not limited to, child care services, schools, and recreational facilities used or occupied by children under the age of 18, or concentrations of lead in the paint on the exterior of a dwelling, that may be creating a danger to health, it may in such cases as it deems essential, order the abatement or remediation of any such condition in a manner and under such safety conditions as it may specify. The Department may also order the removal or covering of soil appurtenant to any dwelling or other premises, including but not limited to, child care services, schools, and recreational facilities used or occupied by children under the age of 18 when it determines that there are concentrations of lead in such soil which exceed allowable limits of the U.S. Environmental Protection Agency found in 40 C.F.R. Part 745, or successor regulations, and further determines that such concentrations may be dangerous to health.
(2) In the dwelling of a child with a blood lead level of three and a half (3.5) micrograms per deciliter or greater. When the Department finds that the interior of any dwelling of a child under 18 years of age with a blood lead level of three and a half (3.5) micrograms per deciliter or higher has a lead-based paint hazard because of its condition, location or accessibility to children, the Department shall order the abatement of any such condition in a manner and under such safety conditions as it may specify.
(3) Objections to Department orders. An owner or other person to whom an order issued pursuant to this subdivision is directed shall notify the Department that he or she objects to such order no later than three (3) days after service of the order. In deciding whether objections to an order issued pursuant to 24 RCNY Health Code § 173.13(d)(2) have merit, the Department may rely on the results of its lead-based paint sampling, provided such results are obtained in accordance with the methodology identified within the definitions of this Code and the Department has a reasonable belief that such reliance will be more protective of the health of a child with an elevated blood lead level.
(4) Failure to comply with Department orders. In the event that the Department determines that the owner or other person having the duty or liability to comply with an order issued pursuant to this subdivision fails to substantially comply therewith within five (5) days after service thereof, the Department shall in accordance with § 27-2056.14 of the Administrative Code, request the Department of Housing Preservation and Development to execute such order pursuant to the provisions of § 17-147 of the Administrative Code.
(5) Definitions. Except as otherwise provided, all terms used in this section shall have the same meanings as the terms defined in 24 RCNY Health Code § 173.14.
(Amended City Record 6/19/2019, eff. 7/19/2019; amended City Record 9/28/2021, eff. 10/28/2021; amended City Record 11/4/2022, eff. 12/4/2022; amended City Record 10/5/2026, eff. 11/4/2026)
§ 173.14. Safety Standards for Lead-Based Paint Abatement and Remediation, and Work That Disturbs Lead-Based Paint
(a) Purpose, scope and applicability. This section establishes work practices and safety standards for (1) abatement and other reduction of lead-based hazards: (2) other work that disturbs surfaces covered with lead-based paint, or paint of unknown lead content; and (3) the minimum qualifications of persons who conduct such activities, in premises where children younger than six years of age reside, receive child care services, or attend prekindergarten or kindergarten classes. This section is intended to reduce the exposure of such children to the lead-based paint hazards associated with such work.
(b) Definitions. When used in this Article, or in 24 RCNY Health Code § 43.23 or 24 RCNY Health Code § 47.63, the following terms shall have the following meanings:
Abatement. shall mean any set of measures designed to permanently eliminate lead-based paint or lead-based paint hazards. Abatement includes: (i) the removal of such hazards, the permanent enclosure of encapsulation of such paint, and the replacement of components or fixtures painted with such paint; and (ii) all preparation, cleanup, disposal and post-abatement clearance testing associated with such measures. Abatement shall not include renovation, remodeling, landscaping or other activities, when such activities are not designed to permanently eliminate lead-based paint hazards, but, instead, are designed to repair, restore, or remodel a given structure or dwelling, even though these activities may incidentally result in a reduction or elimination of lead-based paint hazards. Furthermore, abatement shall not include interim controls, operations and maintenance activities, or other measures and activities designed to temporarily, but not permanently, reduce lead-based paint hazards.
Administrative Code. "Administrative Code" shall mean the Administrative Code of the City of New York.
C.F.R. "C.F.R." shall mean this Code of Federal Regulations.
Chewable surface. "Chewable surface" shall mean:
(1) a protruding interior windowsill
(i) in a dwelling unit in a multiple dwelling where a child under six years of age resides, which is readily accessible to such child, or
(ii) such surface in a day care service, or kindergarten in an elementary school, that is readily accessible to a child under six years of age; and
(2) any other type of interior edge or protrusion in a dwelling unit in a multiple dwelling, day care service or kindergarten, such as a rail or stair
(i) where there is evidence that such other edge or protrusion has been chewed and where an occupant of the dwelling unit has notified the owner that a child under six years of age resides in that multiple dwelling, or
(ii) where the operator of a day care service or kindergarten has observed that a child under six years of age has mouthed or chewed such edge or protrusion.
Child of applicable age. When used in Article 13 of Subchapter 2 of Chapter 2 of Title 27 of the Administrative Code, the term "child of applicable age" shall mean a child who is less than six years of age.
Common area. "Common area" shall mean a portion of a multiple dwelling that is not within a dwelling unit and is regularly used by occupants for access to and egress from any dwelling unit within such multiple dwelling.
Contractor. "Contractor" shall mean any person or firm engaged to perform work that disturbs lead-based paint pursuant to this section.
Deteriorated subsurface. "Deteriorated subsurface" shall mean an unstable or unsound painted subsurface, an indication of which can be observed through a visual inspection, including, but not limited to, rotted or decayed wood, or wood or plaster that has been subject to moisture or disturbance.
Disturb. "Disturb" shall mean any action taken, which breaks down, alters or changes lead-based paint. Lead-based paint disturbances shall include, but not be limited to wet sanding or scraping or routine painting and maintenance activities.
Dwelling. "Dwelling" shall mean any building or structure or portion thereof, which is occupied in whole or in part as the home, residence or sleeping place of one or more human beings. For the purpose of investigations and orders issued by the Commissioner pursuant to 24 RCNY Health Code § 173.13, dwelling shall include exteriors, yards or other areas of the building.
Dwelling unit. "Dwelling unit" shall mean any residential accommodation in multiple dwelling or private dwelling.
ELAP. “ELAP” shall mean the Environmental Laboratory Approval Program certification(s) bestowed upon laboratories by the Wadsworth Center pursuant to New York State Public Health Law § 502. For the purpose of this code, laboratories must be accredited in the Solid and Chemical Materials (Solid Waste and Soils) field by ELAP.
Encapsulation. "Encapsulation" shall mean the application of a covering or coating that acts as a barrier between the lead-based paint and the environment and that relies for its durability on adhesion between the encapsulant and the painted surface, and on the integrity of the existing bonds between paint layers and between the paint and the substrate. Encapsulation may be used as a method of abatement if it is designed and performed so as to be permanent. Only encapsulants approved by the New York State Department of Health, or by another federal or state agency or jurisdiction which the Department or HPD has designated as acceptable may be used for performing encapsulation.
Enclosure. "Enclosure" shall mean the use of rigid, durable construction materials that are mechanically fastened to the substrate in order to act as a barrier between lead-based paint and the environment.
EPA. "EPA" shall mean the U.S. Environmental Protection Agency or successor agency.
Firm. "Firm" shall mean a company, partnership, corporation, sole proprietorship, association, or other business entity that performs lead-based paint activities to which EPA has issued a certificate of approval pursuant to 40 C.F.R. § 745.226(f) or successor regulation.
Friction surface. "Friction surface" shall mean any painted surface that touches or is in contact with another surface, such that the two surfaces are capable of relative motion and abrade, scrape, or bind when in relative motion. Friction surfaces shall include, but not be limited to, window frames and jambs, doors, and hinges.
HEPA vacuum. "HEPA vacuum" shall mean a vacuum cleaner device equipped with a high efficiency particulate air filter capable of filtering out monodispersive particles of 0.3 microns or greater in diameter from a body of air at 99.97 percent efficiency or greater.
HPD. "HPD" shall mean the Department of Housing Preservation and Development of the City of New York.
HUD. "HUD" shall mean the U.S. Department of Housing and Urban Development.
Impact surface. "Impact surface" shall mean any interior painted surface that shows evidence, such as marking, denting, or chipping, that it is subject to damage by repeated sudden force, such as certain parts of door frames, moldings, or baseboards.
Lead-based paint. "Lead-based paint" for the purpose of this Code, shall mean paint or other similar surface coating material containing lead in a concentration of 0.5 milligrams per square centimeter (mg/cm 2 ) or greater as determined by laboratory analysis, or by an x-ray fluorescence (XRF) analyzer. If an XRF analyzer is used, readings shall be corrected for substrate bias when necessary as specified by the Performance Characteristic Sheets (PCS) published by the United States Environmental Protection Agency (EPA) for the specific XRF instrument used. XRF readings shall be classified as positive, negative or inconclusive in accordance with the United States Department of Housing and Urban Development (HUD) "Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing" ( July 2012) or any successor guidelines issued by HUD, and the PCS published by the EPA and HUD for the specific XRF instrument used. XRF results which fall within the inconclusive zone, as determined by the PCS, shall be classified as positive unless laboratory analysis of paint chips show them to be negative. Reports of laboratory results shall be reported in mg/cm 2 and the measure of such laboratory analysis shall be definitive. If laboratory analysis is used to determine lead content, results shall be reported in mg/cm 2 . Where the surface area of a paint chip sample cannot be accurately measured or if an accurately measured paint chip sample cannot be removed, laboratory analysis may be reported in percent by weight. In such case, lead-based paint shall mean any paint or other similar surface coating material containing more than 0.25% of metallic lead, based on the non-volatile content of the paint or other similar surface-coating material. In the absence of a PCS for a specific XRF instrument or a particular function of such instrument, substrate correction, classification of XRF readings, and determinations of inconclusive readings shall be performed in accordance with the manufacturer's instructions for the specific XRF instrument used.
Lead-based paint hazard. "Lead-based paint hazard" shall mean any condition in a dwelling or dwelling unit that causes exposure to lead from lead-contaminated dust, from lead-based paint that is peeling, or from lead-based paint that is present on chewable surfaces, deteriorated subsurfaces, friction surfaces, or impact surfaces that would result in adverse human health effects.
Lead-contaminated dust. “Lead-contaminated dust” shall mean dust collected on floors or windowsills during an investigation of a location or during a lead-contaminated dust clearance test that contains lead at or above the following levels in testing conducted by a laboratory certified by NLLAP and ELAP:
Floors......4 micrograms of lead per square foot.
Windowsills......32 micrograms of lead per square foot.
“Lead-contaminated dust” shall also mean dust collected from window wells during a lead-contaminated dust clearance test that contains lead at or above 80 micrograms of lead per square foot in testing conducted by a laboratory certified by NLLAP and ELAP.
Lead-contaminated dust clearance test. “Lead-contaminated dust clearance test” shall mean testing conducted by an NLLAP and ELAP-certified laboratory for lead in dust collected on floors, window wells, and windowsills in a dwelling following abatement in accordance with this Code or § 27-2056.11 of the Administrative Code.
NLLAP. “NLLAP” shall mean the US EPA National Lead Laboratory Accreditation Program that defines the minimum requirements and abilities that a laboratory must meet to be recognized by the EPA as an accredited lead testing laboratory.
Owner. "Owner" shall mean the owner, operator, managing agent or other person in control of the premises, dwelling, or dwelling unit subject to this section.
Peeling. "Peeling" shall mean that the paint or other surface-coating material is curling, cracking, scaling, flaking, blistering, chipping, chalking or loose in any manner, such that a space or pocket of air is behind a portion thereof or such that the paint is not completely adhered to the underlying surface.
Permanent. "Permanent" shall mean an expected design life of at least 20 years.
Remediation. "Remediation" shall mean the reduction or elimination of a lead-based paint hazard through the wet scraping and repainting, removal, encapsulation, enclosure, or replacement of lead-based paint, or other method approved by the Department.
Removal. "Removal" shall mean a method of abatement that completely eliminates lead-based paint from surfaces.
Replacement. "Replacement" shall mean a strategy or method of abatement that entails the removal of building components that have surfaces coated with lead-based paint and the installation of new components free of lead-based or unsafe lead paint.
Stabilization. "Stabilization" shall mean repairing any physical defect in the substrate of a painted surface that is causing paint deterioration, removing loose paint and other material from the surface to be treated and applying a new protective coating or paint.
Substrate. "Substrate" shall mean the material directly beneath the painted surface out of which the components are constructed, including wood, drywall, plaster, concrete, brick or metal.
Supplemental address. "Supplemental address" shall mean any location where a child with a blood lead level equal to or in excess of three and a half (3.5) micrograms per deciliter spends five (5) or more hours per week.
Turnover. "Turnover" shall mean the occupancy of a dwelling unit subsequent to the termination of a tenancy and the vacatur by a prior tenant of such dwelling.
Underlying defect. "Underlying defect" shall mean a physical condition in a dwelling or dwelling unit that is causing or has caused paint to peel or a painted surface to deteriorate or fail, such as a structural or plumbing failure that allows water to intrude into a dwelling or dwelling unit.
Wet sanding or wet scraping. "Wet sanding" or "wet scraping" shall mean a process of removing loose paint in which the painted surface to be sanded or scraped is kept wet to minimize the dispersal of paint chips and airborne dust.
Work. "Work" shall mean any activity that disturbs paint in accordance with Article 14 of Subchapter 2 of Title 27 of the Administrative Code or as otherwise ordered by the Department to remediate lead-based paint hazards.
Work area. "Work area" shall mean that part of a building where lead-based paint or paint of unknown lead content is being disturbed.
(c) Administrative requirements.
(1) Filing procedures.
(A) Time for filing. No less than twenty-four and no more than ninety-six hours prior to the commencement of work ordered by the Commissioner and not less than ten days prior to commencement of work that will disturb lead-based paint pursuant to § 27-2056.11(a)(2)(ii) of the Administrative Code, an owner shall file with the Department a notice of the commencement of the work. Such notice shall be signed by the owner or by a representative of the firm performing the work. Where work is required to commence in a lesser period of time than that specified herein for the filing of a notice of commencement of work, then such filing shall be made as soon as practicable but prior to the commencement of work.
(B) Content of notice. Such notice shall be in a form satisfactory to or prescribed by the Department and shall set forth at a minimum the following information:
(i) The address of the building and the specific location of the lead-based paint work within the building.
(ii) The name, address and telephone number of the owner of the premises in which the lead based paint work is to be performed.
(iii) The name, address, telephone number and EPA certification number of the firm that will be responsible for performing the work.
(iv) The date and time of commencement of the work, working or shift hours, and the expected date of completion.
(v) A complete description and identification of the surfaces and structures, and surface areas, subject to the work.
(vi) Any changes in the information contained in the notice required by this section, shall be filed with the Department prior to commencement of work, or if work has already commenced, within twenty-four hours of any change.
(2) Training and certification.
(A) Abatement. All work conducted as part of an abatement as defined in this section shall be performed by firms and workers certified to perform lead-based paint activities in accordance with regulations issued by EPA at subpart L of 40 C.F.R. Part 745, or successor rule, for the abatement of lead-based paint hazards.
(B) Other than abatement work.
(i) Other work to remediate lead-based paint hazards that is ordered by the Department or HPD, or work that disturbs large amounts of lead-based paint. All work ordered by the Department, or by the HPD in accordance with § 27-2056.11(a)(1) of the Administrative Code, or work that disturbs over 100 square feet per room conducted in accordance with § 17-911 of the Administrative Code, or 24 RCNY Health Code § 43.23 or 24 RCNY Health Code § 47.63, or § 27-2056.11(a)(2)(ii) of the Administrative Code, shall be performed by firms and trained workers meeting the following requirements:
(aa) Firm requirements. Firms conducting such work shall be certified to perform lead abatement by the EPA in accordance with subpart L of 40 C.F.R. Part 745, or successor rule, for the abatement of lead hazards.
(bb) Worker requirements. Workers conducting such work shall be trained, at a minimum, in accordance with the regulations issued by HUD at 24 C.F.R. § 35.1330(a)(4), or successor rule.
(cc) Lead-contaminated dust clearance testing requirements. No person shall perform a lead-contaminated dust clearance test in relation to such work unless such person is a third party, who is independent of the owner and any individual or firm that performs the work. All personnel performing lead-contaminated dust clearance testing upon completion of work shall be trained, at a minimum, in accordance with regulations issued by HUD at 24 C.F.R. § 35.1340(b)(1), or successor rule.
(ii) Work not ordered by the Department or HPD that disturbs a small amount of paint in a multiple dwelling or in a child care facility or a kindergarten. Work which is not ordered by the Department and disturbs between two and 100 square feet per room, which is performed in accordance with § 17-911 or § 27-2056.11(a)(2)(i) of the Administrative Code, or 24 RCNY Health Code § 43.23 or 24 RCNY Health Code § 47.63, shall be performed by workers trained in accordance with the following requirements:
(aa) Worker requirements. Workers conducting such work shall be trained under regulations issued by HUD at 24 C.F.R. § 35.1330(a)(4), or successor rule.
(bb) Lead-contaminated dust clearance testing requirements. No person shall perform a lead-contaminated dust clearance test in relation to such work unless such person is a third party, who is independent of the owner and any individual or firm that performs the work. Personnel performing lead-contaminated dust clearance testing after completion of work performed in accordance with § 27-2056.11(a)(2)(i) of the Administrative Code shall be trained in accordance with regulations issued by HUD at 24 C.F.R. § 35.1340(b)(1), or successor rule.
(iii) Work not ordered by the Department or HPD, which is performed in a dwelling unit upon turnover. No person shall perform a lead-contaminated dust clearance test in relation to such work unless such person is a third party, who is independent of the owner and any individual or firm that performs the work. Personnel performing lead-contaminated dust clearance testing after completion of work performed on turnover in accordance with § 27-2056.8 of the Administrative Code shall be trained in accordance with regulations issued by HUD at 24 C.F.R. § 35.1340(b)(1), or successor rule.
(3) Recordkeeping.
(A) Records to be kept. An owner shall keep a record of the following information for all lead-based paint remediation work subject to the provisions of this Code or Title 27 of the Administrative Code:
(i) The name, address, and telephone number of the person or entity who performed the work; the start date and completion date for the work.
(ii) A copy of all training certificates, required pursuant to subsection (c)(2) of this section, for the firms and personnel who performed work and clearance dust testing.
(iii) The location of the work performed in each room including a description of such work and invoices for payment for such work.
(iv) Results of lead-contaminated dust clearance tests.
(v) Checklists completed pursuant to 24 RCNY Health Code § 173.14(e)(1)(J) and (e)(2)(F) when occupants are allowed temporary access to a work area.
(B) Time to maintain records. Such records shall be maintained by an owner for a period of ten years from the date of completion of such work or transferred to a subsequent owner and maintained by such subsequent owner during such time period and made available to the Department upon request.
(d) Work methods and occupant relocation.
(1) Minimizing dust dispersion.
(A) Work to remediate or that disturbs lead-based paint shall be conducted in such a manner as to minimize the penetration or dispersal of lead contaminants or lead-contaminated materials from the work area to other areas of the dwelling unit and building or adjacent outdoor areas.
(B) Areas designated as a clean changing area shall be segregated from the work area by a physical barrier to prevent the penetration or dispersal of lead contaminants or lead-contaminated materials from the work area to other areas of the dwelling unit and building and to prevent occupant exposure to materials containing lead.
(2) Prohibited methods. The following methods shall not be used while performing work that disturbs lead-based paint in accordance with this section:
(A) Open flame burning or torching.
(B) Machine sanding or grinding without HEPA local exhaust control.
(C) Abrasive blasting or sandblasting without HEPA local exhaust control.
(D) Heat guns operating above 1,100 degrees Fahrenheit or charring the paint.
(E) Dry sanding or dry scraping.
(F) Paint stripping in a poorly ventilated space using a volatile stripper that is a hazardous substance in accordance with regulations of the United States Consumer Product Safety Commission at 16 C.F.R. § 1500.3, and/or a hazardous chemical in accordance with the United States Occupational Safety and Health Administration regulations at 29 C.F.R. § 1910.1200 or 1926.59, as applicable to the work.
(3) Work practices and surface finishing.
(A) Tools and materials. All tools and materials used when disturbing paint shall be used in accordance with the manufacturer's instructions. Wet sanding, wet scraping, removal, encapsulation, enclosure, replacement and other maintenance and repair activities shall be performed using standard construction and treatment methods.
(B) Seal surfaces. All surfaces where paint has been disturbed shall be sealed and finished with appropriate materials. Underlying substrates shall be dry and protected from future moisture before applying a new protective coating or paint, and all paints and coatings shall be applied in accordance with the manufacturer's recommendations.
(C) Repair underlying conditions. Violations or conditions that cause or may cause paint to peel and which are readily observable and identifiable as to source, including but not limited to water leaks, shall be corrected as part of any lead-based paint remediation work.
(D) Adjust painted doors and windows. All painted windows and painted doors in the work area, including cabinet doors, shall be adjusted to ensure that they are properly hung, so that no painted surfaces bind or stick in a manner that movement of such windows and doors causes abrasion or friction of the surfaces.
(E) Work area preparation completed before commencing remediation. Work intended to remediate lead-based paint hazards shall not commence until work area preparation required by this section has been completed.
(4) Relocation. An owner shall request that an occupant temporarily relocate from a unit pending completion of work where it appears that work cannot be performed safely with occupants in residence. The owner shall offer a suitable, decent, safe and similarly accessible dwelling unit that does not have lead-based paint hazards to such occupants for temporary relocation. Unreasonable refusal by such occupants to relocate pursuant to such offer shall constitute a refusal of access pursuant to §§ 27-2009 and 27-2056.4(b) of the Administrative Code and, where applicable, 9 NYCRR § 2524.3(e). Relocation shall not be required provided that the work can be done safely with occupants in residence, and provided further that at the end of each day of work, the work area is properly cleaned as specified in 24 RCNY Health Code § 173.14(e)(1)(I)(i); occupants have safe access to areas adequate for sleeping, use of bathroom and kitchen facilities and safe access to entry-/egress pathways; and the work does not create other safety hazards, as specified herein.
(e) Occupant protection.
(1) Work ordered by the Department, or work that disturbs over 100 square feet of lead-based paint per room, regardless of whether such work is ordered by the Department, which is conducted in a child care service or kindergarten pursuant to 24 RCNY Health Code § 47.63 or 24 RCNY Health Code § 43.23 or § 17-911 of the Administrative Code, or work ordered by HPD in accordance with § 27-2056.11(a)(1) of the Administrative Code, or work performed pursuant to § 27-2056.11(a)(2)(ii) of the Administrative Code:
(A) Postings. The following information shall be conspicuously posted no later than twenty-four hours prior to beginning work and shall remain in place until the work area has been cleared for re-occupancy:
(i) Notice of commencement of work. Information on the notice submitted to the Department pursuant to subparagraph (1) of subdivision (c) of this section shall be posted at the entrance to the dwelling and at the entrance to the dwelling unit.
(ii) Warning sign. A warning sign of at least 8 1/2" by 11" reading in letters at least one inch high, as follows: WARNING: LEAD WORK AREA – POISON – NO SMOKING OR EATING. Such information shall be posted adjacent to the work area.
(B) Pre-cleaning and protecting movable items. All floors, movable furniture, draperies, carpets, or other objects in the work area shall be HEPA-vacuumed or washed; all movable items shall then be moved out of the work area or otherwise covered with two layers of six-mil disposable polyethylene sheeting before work begins. Such sheeting shall be taped together with waterproof tape, and taped to the floors or bottom of the walls or baseboards, so as to form a continuous barrier to the penetration of dust.
(C) Sealing vents. Forced-air systems within the room where work that disturbs lead-based paint is occurring shall be turned off and covered with two layers of six-mil polyethylene sheeting and waterproof tape to prevent lead contamination and lead dispersal to other areas.
(D) Affixing doorway entrance flap. After all movable objects have been removed, the work area shall be sealed off from non-work areas by taping with waterproof tape, two layers of disposable, six-mil polyethylene sheeting over every entrance or doorway to the work area, as follows: To deter the dispersal of lead dust one sheet shall be taped along all sides of the doorway and a slit shall be cut down the middle of the sheeting, leaving intact at least six inches of sheeting on the top and six inches of sheeting on the bottom of the doorway. A second sheet of polyethylene large enough to cover the doorway, shall be attached to the top of the doorway in the room or area where work is being conducted and shall act as a flap opening into the work area.
(E) Covering floors. The floor of the work area shall be covered with at least two sheets of disposable six-mil polyethylene sheeting. Such sheeting shall be taped together with waterproof tape, and taped to the bottom of the walls or baseboard, so as to form a continuous barrier to the penetration of dust to the floor. The furniture and non-movable furnishings, such as counters, cabinets, and radiators in the work area shall be removed or covered with such taped sheeting.
(F) Sealing openings. All openings, including windows, except those required to be open for ventilation, not sealed off or covered in accordance with 24 RCNY Health Code § 173.14(e)(1)(C) of this Code, shall be sealed with two layers of six-mil polyethylene sheeting and waterproof tape to prevent the penetration or dispersal of lead contaminants or lead-contaminated material.
(G) Instructing occupants. Occupants shall be instructed by the owner and contractor to avoid entering work areas in which work is ongoing until final clearance levels have been achieved.
(H) Hazardous materials. All paints, thinners, solvents, chemical strippers or other flammable materials shall be delivered to the building and maintained during the course of the work in their original containers bearing the manufacturer's labels, and all material safety data sheets, as may be required by law, shall be on-site and shall be made available upon request to the occupants of the dwelling unit.
(I) Clean-up and lead-contaminated dust clearance testing procedures.
(i) Daily clean-up. At the completion of work each day, the work area shall be thoroughly wet-mopped or HEPA vacuumed. No polyethylene sheeting, drop cloths, or other materials that are potentially hazardous to young children or infants shall be accessible outside the work area. In addition, any work area and other adjoining area exposed to lead or lead contaminated materials shall be cleaned as follows:
(aa) Large debris. Large demolition-type debris (e.g., door, windows, trim) shall be wrapped in six-mil polyethylene, sealed with waterproof tape, and moved to the area designated for trash storage on the property to be properly disposed of in a lawful manner.
(bb) Small debris. Small debris shall be HEPA-vacuumed or wet swept and collected. Before wet sweeping occurs, the affected surfaces shall be sprayed with a fine mist of water to keep surface dust from becoming airborne. Dry sweeping is prohibited. The swept debris and all disposable clothing and equipment shall be placed in double four-mil or single six-mil plastic bags which shall be sealed and stored along with other contaminated debris in the work area and shall be properly disposed of in a lawful manner.
(cc) Clean-up adjacent to the work area. On a daily basis, as well as during final clean-up, the area adjacent and exterior to the work area shall be examined visually to ensure that no lead debris has escaped containment. Any such debris shall be wet swept and HEPA vacuumed, collected and disposed of as described above.
(dd) Supply storage. Upon finishing work for the day, all rags, cloths and other supplies used in conjunction with chemical strippers or other flammable materials, or materials contaminated with lead dust or paint shall be stored at the end of each work day in sealed containers or removed from the premises, in a lawful manner.
(ii) Final clean-up. Final cleaning shall be conducted as follows, in the following sequence:
(aa) The final cleaning process shall start no sooner than one (1) hour after lead-based paint disturbance activities have been completed, but before repainting, if necessary.
(bb) First, all polyethylene sheeting shall be sprayed with water mist and swept prior to removal. Polyethylene sheeting shall be removed by starting with upper-level polyethylene, such as that on windows, cabinets and counters, folding the corners, ends to the middle, and placing in double four-mil or single six-mil plastic bags. Plastic bags shall be sealed and properly disposed of in a lawful manner.
(cc) Second, all surfaces in the work area shall be HEPA vacuumed. Vacuuming shall begin with ceilings and proceed down the walls to the floors and include furniture and carpets.
(dd) Third, all surfaces in the work area shall be washed with a detergent solution. Washing shall begin with the ceiling and proceed down the walls to the floor. Wash water shall be properly disposed of in a lawful manner.
(ee) Fourth, all surfaces exposed to lead dust generated by the lead-based paint disturbance process shall be HEPA vacuumed again. Vacuuming shall begin with ceilings and proceed down the walls to the floors and include furniture and carpets.
(ff) Fifth, all surfaces shall be inspected to ensure that all surfaces have been cleaned and all visible dust and debris have been removed. If all visible dust and debris have not been removed, affected surfaces shall be re-cleaned.
(iii) Final inspection. After final clean-up, and re-painting if necessary, has been completed, a final inspection shall be made by a third party retained by the owner who is independent of the owner and the contractor. The final clearance evaluation shall take place at least one (1) hour after the final cleaning and shall include a visual inspection and surface dust testing. Three wipe samples shall be collected and tested from each room or area where work has been conducted; one wipe sample each shall be taken from a window well, a window sill and the floor. In addition, wipe samples shall be collected and tested from the floor in rooms or areas immediately adjacent to the work area.
(iv) Clearance for permanent re-occupancy after completion of work. The work area may not be cleared for permanent re-occupancy until test results from a laboratory accredited by ELAP and NLLAP showing that there is no lead-contaminated dust in the dwelling have been received. However, temporary access to work areas may be allowed, provided that clean-up is completed, and dust test samples have been collected, in compliance with 24 RCNY Health Code § 173.14(e)(1)(I)(i),(ii) and (iii). The owner shall provide a copy of all lead-contaminated dust clearance test results to the occupants of the dwelling or dwelling unit. Copies of lead-contaminated dust clearance test results shall be submitted to the Department whenever abatement or remediation of lead-based paint hazards has been ordered by the Department or Commissioner.
(J) Temporary access to work areas when occupants not relocated. When occupants are not relocated, temporary access may be allowed to areas in which work is in progress after work has ceased for the day provided that at the end of each work day:
(i) Any work area to be accessed is to be properly cleaned as specified in the daily clean-up requirements of 24 RCNY Health Code § 173.14(e)(1)(I)(i) and the final clean-up requirements of 24 RCNY Health Code § 173.14(e)(1)(I)(ii)(bb) through (dd) and (ff);
(ii) There are no safety hazards (including, but not limited to, exposed electric wiring or holes in floor) or covered vents;
(iii) Floor coverings containing leaded dust and debris and hazardous materials are removed;
(iv) Floors in the work area are re-covered with a non-skid floor covering securely taped to the floor;
(v) Work areas are prepared in accordance with the requirements above when work recommences; and
(vi) At the end of each workday, and before access is permitted, a checklist indicating compliance with these conditions is completed and signed, in accordance with 24 RCNY Health Code § 3.19, by the person responsible for overseeing the work.
(vii) Temporary access in accordance with these provisions may be allowed for no longer than five days. If work has not resumed within five days, temporary access may continue only if the person responsible for overseeing the work has repeated the work required by clauses (i)-(vi). Nothing herein shall extend the time for compliance with any order issued pursuant to this Code or for correction of any violation of the Administrative Code.
(2) Work that disturbs between two (2) and 100 square feet of lead-based paint per room that is being performed in accordance with §§ 17-911 and 27-2056.11(a)(2)(i) of the Administrative Code, or 24 RCNY Health Code § 43.23 or 24 RCNY Health Code § 47.63.
(A) Postings and warning sign. A warning sign shall be posted in accordance with subparagraph (1)(A)(ii) of subdivision (e) of this section and caution tape shall be placed across the entrance to the work area.
(B) Pre-cleaning and protecting movable items. All floors, movable furniture, draperies, carpets, or other objects in the work area shall be HEPA-vacuumed or washed; all movable items shall then be moved out of the work area or otherwise covered with polyethylene plastic or equivalent sheeting. All plastic or equivalent sheeting used during the performance of the work shall be of sufficient thickness and durability to prevent tearing during the performance of the work. Such sheeting shall be of sufficient length and width to prevent dust and other debris generated by the work from spreading to areas unprotected by such sheeting. Such sheeting must be adequately secured to prevent movement of the sheeting during the performance of the work.
(C) Covering floors. The floor of the work area shall be covered with polyethylene plastic or equivalent sheeting. All plastic or equivalent sheeting used during the performance of the work shall be of sufficient thickness and durability to prevent tearing during the performance of the work. Such sheeting shall be of sufficient length and width to prevent dust and other debris generated by the work from spreading to areas unprotected by such sheeting. Such sheeting must be adequately secured to prevent movement of the sheeting during the performance of the work. Multiple layers of polyethylene sheeting shall be used as needed to prevent dust from contaminating the floor.
(D) Sealing openings. Where applicable, forced air systems in the work area shall be turned off and any openings in the work area shall be sealed with polyethylene or equivalent sheeting to prevent the penetration or dispersal of lead contaminants or lead-contaminated material.
(E) Instructing occupants. Occupants shall be instructed by the owner and contractor to avoid entering the work area until final clean-up has been completed. The owner shall provide temporary relocation of the occupants of a dwelling or a dwelling unit to appropriate housing when work cannot be performed safely.
(F) Hazardous materials. All paints, thinners, solvents, chemical strippers or other flammable materials shall be delivered to the building and maintained during the course of the work in their original containers bearing the manufacturer's labels, and all material safety data sheets, as may be required by law, shall be on-site and shall be made available upon request to the occupants of the dwelling unit.
(G) Clean-up and lead-contaminated clearance dust testing. Clean-up and lead-contaminated dust clearance testing shall be conducted in accordance with 24 RCNY Health Code § 173.14(e)(1)(I).
(H) Temporary access to work areas when occupants not relocated. When occupants are not relocated, temporary access may be allowed to areas in which work is in progress after work has ceased for the day provided that at the end of each work day:
(i) Any work area to be accessed is to be properly cleaned as specified in the daily clean-up requirements of 24 RCNY Health Code § 173.14(e)(1)(I)(i) and the final clean-up requirements of 24 RCNY Health Code § 173.14(e)(1)(I)(ii)(bb) through (dd) and (ff);
(ii) There are no safety hazards (including, but not limited to, exposed electric wiring or holes in the floor) or covered vents;
(iii) Floor coverings containing leaded dust and debris and hazardous materials are removed;
(iv) Floors in the work area are re-covered with a non-skid floor covering securely taped to the floor;
(v) Work areas are prepared in accordance with the requirements above when work recommences; and
(vi) At the end of each workday, and before access is permitted, a checklist indicating compliance with these conditions is completed and signed, in accordance with 24 RCNY Health Code § 3.19, by the person responsible for overseeing the work.
(vii) Temporary access in accordance with these provisions may be allowed for no longer than five days. If work has not resumed within five days, temporary access may continue only if the person responsible for overseeing the work has repeated the work required by clauses (i)-(vi). Nothing herein shall extend the time for compliance with any order issued pursuant to this Code or for correction of any violation of the Administrative Code.
(3) Work performed to remediate lead-based paint hazards on turnover in accordance with § 27-2056.8 of the Administrative Code.
(A) Preparation and work. The procedures described in 24 RCNY Health Code § 173.14(e)(2)(A) through (D) shall be followed.
(B) Clean-up. At the completion of work, the work area shall be thoroughly wet-mopped or HEPA vacuumed and a visual examination shall be conducted in the work area and the area adjacent and exterior to the work area. Any noted lead-contaminated dust or debris shall be wet-mopped or HEPA vacuumed. All rags, cloths and other supplies used in conjunction with chemical strippers or other flammable materials, or materials contaminated with lead dust or paint shall be stored at the end of each work day in sealed containers or removed from the premises, in a lawful manner.
(C) Clearance dust testing. Clearance testing for lead-contaminated dust shall be conducted in accordance with 24 RCNY Health Code § 173.14(e)(1)(I).
(f) Investigation of unsafe lead work practices by the Department.
(1) Authority to inspect. The Department may inspect any premises where work that is subject to this section is in progress or has been completed.
(2) Scope of authority. Such inspection may include but not be limited to premises where abatement or remediation of lead-based paint hazards is being conducted, where any work which may disturb lead-based paint or paint of unknown lead content is being conducted, or which is the subject of a complaint to the Department pursuant to § 17-185 of the Administrative Code, and any areas affected by the emission or release of leaded dust or debris.
(3) Actions authorized. If the Department determines that such work is not being conducted in accordance with the provisions of this section, or other applicable law, the Department may order that such work be stopped immediately; that the premises be cleared of uncontained leaded dust and debris; that the conditions or work practices constituting a departure from the provisions of this section be corrected; and that the owner and any persons performing such work submit a work plan prior to resuming work, to demonstrate their ability and willingness to comply with the provisions of this Code or other applicable law.
(g) Declaration pursuant to Administrative Code § 17-145. The existence of a lead-based paint condition or a lead-based paint hazard pursuant to 24 RCNY Health Code § 173.13, or a failure to comply with this section is hereby declared to constitute a public nuisance and a condition dangerous to life and health, pursuant to § 17-145 of the Administrative Code. Every person obligated to comply with the provisions of this section or 24 RCNY Health Code § 173.13 is hereby ordered to abate or remediate such nuisance by complying with any order or direction issued by the Department.
(h) Modification by Department. When the Department determines that the strict application of any provision of this section or 24 RCNY Health Code § 173.13 presents practical difficulties, the Commissioner or their designee may, in a specific instance, modify the application of such provision consistent with the general purpose of these sections and upon such condition(s) the Department deems necessary to protect life and health. Failure to comply with the terms of a modification may render such modification null and void and result in enforcement by the Department. The denial of a request for modification by the Commissioner shall be deemed a final agency determination.
(Amended City Record 6/19/2019, eff. 7/19/2019; amended City Record 9/28/2021, eff. 10/28/2021; amended City Record 11/4/2022, eff. 12/4/2022; amended City Record 6/13/2025, eff. 7/13/2025; amended City Record 10/5/2026, eff. 11/4/2026)
§ 173.15. Unsafe Lead-Based Paint Work Practices. [Repealed]
BetaNYC's copy has no text for this section. Read 24 RCNY Health Code § 173.15 at American Legal Publishing.
§ 173.16. Lye Intended for Household Use. [Repealed]
BetaNYC's copy has no text for this section. Read 24 RCNY Health Code § 173.16 at American Legal Publishing.
§ 173.17. Plastic Bags
(a) No person shall sell, offer for sale, or deliver, or offer for delivery, or give away any plastic bag or partial plastic bag intended for domestic or household use, or for packaging articles intended for domestic or household use, or which is so designed or decorated so as to encourage its use as a toy, the length and width of which when added together totals twenty-five inches or more and the opening side of which is seven inches or more and the material of which is less than one mil (1/1,000 inch) in thickness; unless such plastic bag bears the following warning statement, or a warning statement which the Commissioner has approved as the equivalent thereof:
"WARNING: To avoid danger of suffocation, keep this plastic bag away from babies and children. Do not use this bag in cribs, beds, carriages or play pens."
(b) Such warning statement shall be imprinted in a prominent place on the plastic bag or shall appear on a label securely attached to the bag in a prominent place, and shall be printed in legible type which shall be contrasted by typography, layout or color from the contents of the bag and from other printed matter on the bag, if any. The size of the print of such statement shall be as follows:
Total length and width of bag Size of print 60 inches or more at least 24 point 40 - 59 inches at least 18 point 30 - 59 inches at least 14 point 25 - 20 inches at least 10 point
§ 173.19. Glues and Cements Containing Volatile Solvents
(a) Except as other-wise provided in subsection (b), no person shall sell, offer for sale, deliver or give away to any individual under the age of 18 years any glue or cement commonly known as plastic cement, household cement, cement, or any other similar substance, if such glue or cement contains one or more of the following volatile solvents:
1. Toluol
2. Hexane
3. Trichlorethylene
4. Acetone
5. Toluene
6. Ethyl Acetate
7. Methyl Ethyl Ketone
8. Trichloroethane
9. Isopropanol
10. Methyl Isobutyl Ketone
11. Methyl Cellosolve Acetate
12. Cyclohexanone
13. Any other substance which the Commissioner from time to time determines to be similar to such solvents. The determination of the Commissioner shall be published in the City Record.
(b) This section shall not apply:
(1) To any glue or cement which has been certified by the Department that it contains a substance which makes such glue or cement malodorous or causes such glue or cement to induce sneezing, or
(2) Where the glue or cement is sold, delivered or given away simultaneously with and as part of a kit used for construction of model airplanes, model boats, model automobiles, model trains or other similar models, or
(3) Where the person to whom the glue or cement is sold, delivered or given is a member of a hobby association and who properly identifies himself as such by an official membership card or other means of identification issued by such association. For the purposes of this section, the term hobby association means a group of persons (1) whose principal function is the construction of model airplanes, model boats, model automobiles, model trains or other similar objects, (2) which is composed of 25 or more members, and (3) is approved by the Department. The Department shall from time to time cause to be published in the City Record a list of approved hobby associations.
§ 173.21. Sale of Toxic and Hazardous Substances Prohibited; Embargo or Seizure Authorized
(a) No person may sell, hold for sale, transport, or give away hazardous or toxic substances or products unless such items are capable of being labeled pursuant to this Article to prevent misuse or harm.
(b) When in the opinion of the Department a substance or product is hazardous or toxic within the meaning of this Article, the Department may seize, embargo, or condemn such material pursuant to 24 RCNY Health Code § 3.03.
(c) In addition to other penalties imposed for violations of this Article, the Department may require persons to take an online safe products awareness training program developed by the Department.
(Added City Record 6/19/2019, eff. 7/19/2019)
Title IV, Part B, Article 175. Radiation Control*
* Editor's note: This article was repealed and replaced in its entirety. See City Record 4/24/2019, eff. 5/24/2019.
§ 175.01. Applicability and Communications
(a) Applicability.
(1) Except as provided in subdivision (b) of this section, this Article applies to any person who sells, transfers, assembles, receives, produces, possesses, or uses any radiation source in New York City.
(2) Part II of this Article (24 RCNY Health Code §§ 175.08 – 175.70) provides specific requirements for radiation equipment registrants and certified registrants.
(3) Part III of this Article (24 RCNY Health Code §§ 175.100 – 175.108) provides specific requirements for radioactive materials licensees.
(b) Inapplicability.
(1) This Article does not apply to any person with respect to any radiation source subject to regulation, as provided for by law, by the New York State Departments of Health or Environmental Conservation. This exclusion does not apply to the use of such sources in places where the general public may be exposed; or to persons with respect to radiation sources used at industrial or commercial establishments for the application of radiation to human beings.
(2) This Article does not apply to any common or contract carrier or any shipper operating within New York City to the extent that such carrier or shipper is subject to regulation as provided for by law by the U.S. Department of Transportation or other agencies of the United States or agencies of the State or City of New York, except for compliance with provisions relating to transportation of radioactive materials set forth in 24 RCNY Health Code § 175.106.
(c) Communications. Except as otherwise provided for in this Article, or as authorized by the Department, all applications, notifications, reports or other communications required by this Article must be addressed to the Department at:
NYC Department of Health and Mental Hygiene Office of Radiological Health 42-09 28th St, CN 60 Long Island City, New York 11101
(Added City Record 4/24/2019, eff. 5/24/2019)
§ 175.02. Inspections and Fees
(a) Inspections.
(1) Any radiation installation subject to the licensure or registration requirements of this Code shall be inspected periodically to ensure compliance with the provisions of this Article and the maintenance of radiation exposures as far below the limits set forth in this Article as practicable. Inspections shall be made at a frequency determined by the Department in its rules.
(2) Unless otherwise indicated, for newly-registered facilities, initial inspections shall be made at or near the time of the beginning of operation.
(3) Inspections shall be made by the Department or, as the Department shall direct for dental and podiatric installations, by a Certified Radiation Equipment Safety Officer (CRESO) approved by the Department, to determine compliance with this Article and this Code.
(i) CRESOs must furnish an inspection report to the operator of the installation, in a form prescribed by the Department and signed by the person who made the inspection, and provide a copy thereof to the Department.
(ii) CRESOs must not charge or propose to charge a fee for an inspection above a fair and reasonable amount as determined by the New York State Department of Health.
(4) Re-inspections or other appropriate follow-up activities will occur to ensure that any violation found during an inspection and not corrected at the end of such inspection is subsequently corrected.
(b) Inspection fees. Notwithstanding any other provision of this Code, the Department is authorized to charge the following inspection fees pursuant to section 225 of the New York State Public Health Law and the regulations promulgated thereunder:
(1) For radiation equipment facilities required to have quality assurance programs pursuant to 24 RCNY Health Code § 175.12, the following inspection fees apply, where examination means the conduct of an x-ray patient exam by radiographic or fluoroscopic or a CT unit regardless of the number of patient exposures or x-ray exposure time:
(i) Hospital-inspected facilities:
(A) Large hospital (more than 40 tubes) base fee: $1960.00
(B) Medium hospital (21-40 tubes) base fee: $1585.00
(C) Small hospital (1-20 tubes) base fee: $1290.00
(ii) Non-hospital facilities:
(A) Large (more than 2500 examinations per year) facility base fee: $670.00
(B) Small (less than 2500 examinations per year) facility base fee: $375.00
(iii) For each tube inspected at facilities identified in (i) or (ii) above of this paragraph, the following inspection fees apply in addition to the base fee:
(A) Radiographic: $120.00
(B) Fluoroscopic: $175.00
(C) Mammographic: $295.00
(D) Dental: $60.00
(E) All other: $60.00
(iv) For radiation equipment facilities not required to have quality assurance programs pursuant to 24 RCNY Health Code § 175.12, the following inspection fees apply:
(A) First tube: $170.00
(B) Each additional tube: $60.00
(2) For linear accelerator facilities, the following is the base fee: $715.00
(3) For facilities licensed to possess and use radioactive materials, the following inspection fees apply:
(i) Specific licenses authorizing teletherapy or gamma stereotactic radiosurgery, the following is the base fee: $320.00
(ii) Specific licenses of limited scope authorizing medical use (except for teletherapy or gamma stereotactic radiosurgery)
(A) Base fee: $610.00
(B) Per site fee: $140.00
(iii) Specific licenses of limited scope authorizing non-human use
(A) Base fee: $385.00
(B) Per site fee: $160.00
(iv) Specific licenses of broad scope authorizing medical use (except for teletherapy or gamma stereotactic radiosurgery)
(A) Base fee: $3515.00
(B) Per site fee: $140.00
(v) Specific license of broad scope authorizing research and development (non-human use)
(A) Base fee: $2450.00
(B) Per site fee: $160.00
(c) Due date for inspection fees. Payment for inspection fees is due and payable 30 days after the billing date. Failure to pay any inspection fee may result in the suspension or revocation of a registration, certified registration or radioactive materials license.
(Added City Record 4/24/2019, eff. 5/24/2019)
§ 175.03. Professional Practitioners and Related Provisions
(a) Nothing in this Article shall limit any human use of radiation in diagnostic and therapeutic procedures, provided that with respect to human use of radioactive materials, such use is in accordance with a specific license or registration issued pursuant to this Article, or an exemption therefrom, or under a license issued by the New York State Department of Health or the United States Nuclear Regulatory Commission or an Agreement State.
(b) Each professional practitioner who treats or diagnoses any alleged or proven case of radiation illness or radiation injury to any individual, except that which can be expected in the normal course of radiation therapy and interventional fluoroscopic exams, must report to the Department in writing within 7 days of such treatment or diagnosis, the fact thereof and the full name, address, patient ID number, and age of such individual diagnosed or treated.
(c) No person other than a professional practitioner acting within the scope of their practice shall direct or order the application of radiation to a human being; nor shall any person other than a professional practitioner or a person working under the direction, order, or direct supervision of a professional practitioner apply radiation to a human being. Such direction, order to apply, application of, or administration of radiation must be within the lawful scope of, and in the course of, the practitioner's professional practice and must comply with the provisions of the license or other authorization of the professional practitioner under the New York State Education Law, or any applicable successor law and all regulations pertinent thereto, including, but not limited to provisions as to those parts of the human body and those persons which the professional practitioner may diagnose, analyze or treat or to which she may direct or order the application of, or apply, radiation, and provisions as to the type of radiation which the professional practitioner may use and the purpose for which the professional practitioner may use it.
(d) A professional practitioner shall be responsible for the supervision of any radiation employee who administers radiation to human beings to assure that each exposure is given consistent with expected medical benefit and in accordance with applicable standards or requirements relating to the practice for which such professional practitioner is licensed.
(e) A professional medical physicist shall be responsible for complying with the requirements of Article 166 of the New York State Education Law and applicable regulations, including Subpart 79-8 of Part 79 of Title 8 of the New York Codes, Rules and Regulations, or any applicable successor law or regulation.
(f) A licensed radiologic technologist must comply with applicable provisions of Article 35 of the New York State Public Health Law and Part 89 of Title 10 of the New York Codes, Rules and Regulations in order to provide services under this Article, including compliance with licensure requirements and the limitations, (if any, established by the New York State Department of Health, Bureau of Radiologic Technology) under which radiologic technologists and other persons, other than professional practitioners, may apply x-rays to human beings and all regulations pertinent thereto so as to assure maximum medical benefit with minimum radiation exposure.
(Added City Record 4/24/2019, eff. 5/24/2019)
§ 175.04. Prohibited Uses and Activities
(a) Prohibited uses. The following are prohibited uses of radiation equipment:
(1) Hand-held fluoroscopic screens.
(2) Shoe-fitting fluoroscopic devices.
(3) Intraoral fluoroscopy in dental examinations.
(4) Photofluorographic equipment.
(5) Equipment employing bare overhead or uninsulated conductors.
(6) Non-image intensified fluoroscopes.
(7) Capacity energy storage equipment used to image humans, effective July 1, 2021.
(8) Intraoral dental x-ray machines operated at less than a measured 51 kVp effective July 1, 2021
(b) Prohibited activities.
(1) No person shall operate x-ray equipment such that the useful beam is applied to human beings unless such individual is a professional practitioner or is otherwise authorized to operate x-ray equipment pursuant to state law.
(2) The sale, lease, transfer or loan of x-ray or fluoroscopic equipment or related supplies is prohibited, except to persons engaged in an occupation where such use is permitted or to institutions where such use is permitted. However, this restriction shall not apply to persons intending to use x-ray or fluoroscopic equipment and supplies solely for the application of radiation to other than human beings, nor to the acquisition of such equipment or supplies by wholesalers, distributors or retailers in the regular course of their trade or business.
(3) No person shall sell, lease, transfer, lend or install any radiation-producing equipment, or related supplies, unless such supplies or equipment when properly placed into operation or properly used will meet the requirements of this Article. A person who undertakes to repair such equipment must do so such that when it is placed in operation or properly used after the repair, the equipment will meet all applicable standards, including the requirements of this Article, for radiation protection and safety generally.
(c) On or before July 1, 2022, portable or mobile x-ray equipment must only be used for examinations where it is impractical to transfer the patient to a stationary x-ray installation. Facilities are prohibited from using portable or mobile x-ray units in routine clinical x-ray exams; however, this shall not prohibit hospitals from using portable or mobile x-ray units in clinical exams in emergency room and trauma center locations and for in-house patients that are not ambulatory. Additionally, this shall not prohibit mobile or portable x-ray units in patient homes or long term health care facilities.
(Added City Record 4/24/2019, eff. 5/24/2019)
§ 175.05. Vacating Premises
No less than 30 days before vacating or relinquishing possession or control of premises which may have been contaminated with radioactive material as a result of their activities, each licensee or registrant must notify the Department in writing of their intent to vacate. When deemed necessary by the Department, the licensee or registrant must decontaminate the premises in such a manner as the Department may specify. Registrants must notify the Department of the disposition of the previously-registered equipment.
(Added City Record 4/24/2019, eff. 5/24/2019)
§ 175.06. Modification by Department
When the Department determines that the strict application of any provision of this Article presents practical difficulties, the Commissioner or their designee may, in a specific instance, modify the application of such provision consistent with the general purpose of this article and upon such condition(s) the Department deems necessary to protect life and health. Failure to comply with the terms of a modification may render such modification null and void and result in enforcement by the Department. The denial of a request for modification by the Commissioner shall be deemed a final agency determination.
(Added City Record 4/24/2019, eff. 5/24/2019; amended City Record 6/13/2025, eff. 7/13/2025)
§ 175.07. Enforcement
Notwithstanding anything to the contrary in this Code, the Department may:
(a) by rule, regulation, order, license condition or registration condition, or otherwise as appropriate, impose requirements upon any person subject to this Article, in addition to those expressly set forth in this Article, as it deems appropriate or necessary to protect the public health and safety and to minimize danger to life or property from radiation hazards;
(b) amend, suspend or revoke any license, registration or certified registration issued pursuant to this Article when it finds that any person holding such license, registration or certified registration is not in compliance with this Article, or other applicable laws, rules or regulations;
(c) by order, require the removal through an authorized person, or the surrender to the Department, of any radiation source by any person who:
(1) does not hold, or continue to hold, a valid license, registration or certified registration issued by the Department; or
(2) is not able or equipped, or who fails to observe with regard to such radiation source those radiation protection requirements of this Article, or who uses such radiation source in violation of this Article, Department order, or other applicable law, rule or regulation, or as set forth in a license, registration or certified registration issued by the Department. Upon such an order, such person shall be required to decontaminate any premises which may have been contaminated with radioactive material as a result of licensed or registered activities to radiation levels specified by the Department. Any expenses incidental to the transfer, surrender and decontamination shall be borne by the person responsible for the source.
(d) Except where the protection of the public health requires immediate action, no Department actions described in subdivisions (b) and (c) of this section shall take effect until the person so affected is given reasonable notice and an opportunity to be heard by the Department.
(Added City Record 4/24/2019, eff. 5/24/2019)
§ 175.08. Definitions
This section has 6 pictures (figures, equations, or tables drawn as images) that BetaNYC's copy does not show. Read 24 RCNY Health Code § 175.08 at American Legal Publishing.
The following definitions apply to Parts I and II (24 RCNY Health Code §§ 175.01 through 175.70) of this Article:
"Absorbed dose (D)" means the energy imparted by ionizing radiation per unit mass of irradiated material. The SI unit of absorbed dose is joule per kilogram or gray (Gy). The previously used ("traditional") unit of absorbed dose is the rad (1 Gy = 100 rad).
"Absorbed dose rate" means absorbed dose per unit time, for machines with timers, or dose monitor unit per unit time for linear accelerators.
"Accelerator" means any machine capable of accelerating electrons, protons, or other charged particles in a vacuum and of discharging the resultant particulates or other radiation into a medium at energies usually in excess of 1 MeV.
"Accessible surface" means the external or outside surface of the enclosure or housing of the radiation producing machine as provided by the manufacturer. This includes the high-voltage generator, doors, access panels, latches, control knobs, and other permanently mounted hardware and including the plane across the exterior edge of any opening.
"Added filtration" means any filtration which is in addition to the inherent filtration.
"Air kerma (K)" means the kinetic energy released in air by ionizing radiation per mass of air. The SI unit of air kerma is joule per kilogram or gray (Gy).
"Air kerma rate (AKR)" means the air kerma per unit time.
"As low as reasonably achievable (ALARA)" means making every reasonable effort to maintain exposures to radiation as far below the dose limits in this Article as practical, consistent with the purpose for which the licensed or registered activity is undertaken, taking into account the state of technology, the economics of improvements in relation to the state of technology, the economics of improvements in relation to benefits to the public health and safety, and other societal and socioeconomic considerations in the public interest.
"Alert value" means a dose index (e.g., of CTDIvol (mGy) or DLP (mGy-cm)) that is set by the registrant to trigger an alert to the CT operator prior to scanning within an ongoing examination. The alert value represents a dose value well above the registrant's established range for the examination that warrants more stringent review and consideration before proceeding.
"Aluminum equivalent" means the thickness of type 1100 aluminum alloy affording the same attenuation, under specified conditions, as the material in question.
"Analytical x-ray equipment" means equipment that generates (by electronic means) and uses ionizing radiation for the purpose of examining the microstructure of materials, i.e. diffraction and spectroscopy (including fluorescence).
"Annual" means at least once per year, at about the same time each year, plus or minus one calendar month.
"Attenuation block" means a block or stack of type 1100 aluminum alloy, or aluminum alloy having equivalent attenuation, with dimensions 20 centimeters (cm) or larger by 20 cm or larger by 3.8 cm, that is large enough to intercept the entire x-ray beam.
"Authorized user" means a licensed physician who is identified as a user of therapeutic equipment on a certified registration issued by the Department.
"Automatic exposure control (AEC)" means a device which automatically controls one or more technique factors in order to obtain at a preselected location a required quantity of radiation.
"Automatic exposure rate control (AERC)" means a device which automatically controls one or more technique factors in order to obtain, at a preselected location, a required quantity of radiation per unit time.
"Background radiation" means radiation from cosmic sources; naturally occurring radioactive material, including radon (except as a decay product of source or special nuclear material); and global fallout as it exists in the environment from the testing of nuclear explosive devices or from past nuclear accidents such as Chernobyl that contribute to background radiation and are not under the control of the licensee or registrant. Background radiation does not include radiation from any regulated sources of radiation.
"Barrier" has the same meaning as "protective barrier."
"Beam axis" means a line from the source through the centers of the x-ray fields.
"Beam-limiting device" means a device which provides a means to restrict the dimensions of the x-ray field.
"Beam monitoring system" means a system designed and installed in the radiation head to detect and measure the radiation present in the useful beam.
"Beam scattering foil" means a thin piece of material, usually metallic, placed in the beam to scatter a beam of electrons in order to provide a more uniform electron distribution in the useful beam.
"Beam port" means an opening on the x-ray apparatus designed to emit a primary beam. This does not include openings on baggage units.
"Biennial" means the test is done at least once every other year, at about the same time, plus or minus one calendar month.
"Biweekly" means at least once per two consecutive weeks (see "Weekly").
"Bone densitometer" means a device intended for medical purposes to measure bone density and mineral content by x-ray or gamma ray transmission measurements through the bone and adjacent tissues. This generic type of device may include signal analysis and display equipment, patient and equipment supports, component parts, and accessories.
"Bone densitometry" means a noninvasive measurement of certain physical characteristics of bone that reflect bone strength. Test results are typically reported as bone mineral content or density and are used for diagnosing osteoporosis, estimating fracture risk, and monitoring changes in bone mineral content.
"C-arm fluoroscope" means a fluoroscopic x-ray system in which the image receptor and the x- ray tube housing assembly are connected or coordinated to maintain a spatial relationship. Such a system allows a change in the direction of the beam axis with respect to the patient without moving the patient.
"Calibration" means the determination of the response or reading of an instrument relative to a series of known radiation values over the range of the instrument, or the strength of a source of radiation relative to a standard.
"Cassette holder" means a device, other than a spot-film device, that supports or fixes the position of the cassette-based image receptor during a radiographic exposure.
"Cathode ray tube" means any device used to accelerate electrons for demonstration or research purposes, except where such cathode ray tube is incorporated into a television or display monitor that is subject to, and has met applicable federal radiation safety performance standards in 21 C.F.R. §§ 1010 and 1020.10.
"Certified Radiation Equipment Safety Officer" (CRESO) means an individual who holds an unexpired certificate as a radiation equipment safety officer issued by the New York State Department of Health.
"C.F.R." or "10 C.F.R." means, except where a citation to a specific section is given, the regulations issued by the United States Nuclear Regulatory Commission contained in Chapter I of Title 10 of the Code of Federal Regulations.
"Changeable filters" means any filter, exclusive of inherent filtration, which can be removed from the useful beam through any electronic, mechanical, or physical process.
"Coefficient of variation (C)" means the ratio of the standard deviation to the mean value of a population of observations. It is estimated using the following equation:
where:
s = Estimated standard deviation of the population.
= Mean value of observations in sample;
x i = ith observation in sample;
n = Number of observations sampled.
"Collimator" means a device for restricting the useful radiation in one or more directions.
"Computed radiography (CR)" means a digital x-ray imaging method in which a photo-stimulable phosphor is used to capture and store a latent image. The latent image is read out by stimulating the phosphor with a laser. Computed radiography systems may use cassettes to house the phosphor, or it may be integrated into a digital radiography system. See also, the definition of "digital radiography."
"Computed tomography (CT)" means the production of a tomogram by the acquisition and computer processing of x-ray transmission data.
"Computed tomography dose index (CTDI)" means the average absorbed dose, along the z-axis, from a series of contiguous irradiations. It is measured from one axial CT scan (one rotation of the x-ray tube), and is calculated by dividing the integrated absorbed dose by the nominal total beam collimation. The scattering media for CTDI consist of two (16 and 32 cm in diameter) polymethylmethacrylate (PMMA, e.g., acrylic or Lucite) cylinders of 14 cm length. The equation is:
where:
D(z) = the radiation dose profile along the z-axis,
N = the number of tomographic sections imaged in a single axial scan. This is equal to the number of data channels used in a particular scan. The value of N may be less than or equal to the maximum number of data channels available on the system, and
T = the width of the tomographic section along the z-axis imaged by one data channel. In multiple-detector-row (multi-slice) CT scanners, several detector elements may be grouped together to form one data channel. In single-detector-row (single-slice) CT, the z-axis collimation (T) is the nominal scan width.
"Computed tomography (CT) scan" and "computerized axial tomography (CAT) scan" refer to an imaging procedure that uses x-rays to create cross-sectional images of the human body.
"Cone Beam Computed Tomography (CBCT)" is a volumetric imaging modality. Volumetric data are acquired using two dimensional digital detector arrays and a cone-shaped x-ray beam (instead of fan-shaped) that rotates around the patient. Reconstruction algorithms can be used to generate images of any desired plane.
"Contact therapy system" means a therapeutic radiation machine with a short target to skin distance (TSD), usually less than 5 centimeters.
"Control panel" means that part of the x-ray control upon which are mounted the switches, knobs, pushbuttons, keypads, touchscreens, and other hardware necessary for manually setting the technique factors.
"Controlled area" has the same meaning as "restricted area".
"Conventional simulator" means any x-ray system designed to reproduce the geometric conditions of the radiation therapy equipment.
"Cradle" means a removable device which supports and may restrain a patient above an x-ray table; or a device whose patient support structure is interposed between the patient and the image receptor during normal use; or which is equipped with means for patient restraint and which is capable of rotation about its long (longitudinal) axis.
"CT conditions of operation" means all selectable parameters governing the operation of a CT x- ray system including nominal tomographic section thickness, filtration, and the technique factors as defined in this Article .
"CT dosimetry phantom" means the phantom used for determination of the dose delivered by a CT x-ray system. The phantom must be a right circular cylinder of polymethyl-methacrylate of density 1.19±0.01 grams per cubic centimeter. Except for pediatric dose measurements, the phantom must be at least 14 centimeters in length and must have diameters of 32.0 centimeters for testing any CT system designed to image any section of the body (whole body scanners) and 16.0 centimeters for any system designed to image the head (head scanners) or for any whole body scanner operated in the head scanning mode. The phantom must provide means for the placement of a dosimeter along its axis of rotation and along a line parallel to the axis of rotation 1.0 centimeter from the outer surface and within the phantom.
"CT number" means the number used to represent the x-ray attenuation associated with each elemental area of the CT image:
where:
k = A constant, a normal value of 1,000 when the Houndsfield scale of CT number is used;
µ x = Linear attenuation coefficient of the material of interest;
µ w = Linear attenuation coefficient of water.
"CTDI100" means the accumulated multiple scan dose at the center of a 100-mm scan and underestimates the accumulated dose for longer scan lengths. It is thus smaller than the equilibrium dose. The CTDI100 requires integration of the radiation dose profile from a single axial scan over specific integration limits. In the case of CTDI100, the integration limits are +50 mm, which corresponds to the 100-mm length of the commercially available "pencil" ionization chamber. CTDI100 is acquired using a 100-mm long, 3-cc active volume CT "pencil" ionization chamber and one of the two standard CTDI acrylic phantoms (16 and 32 cm diameter) and a stationary patient table. The equation is:
"CTDIvol" see "Volume Computed Tomography Dose Index (CTDIvol)"
"CTDIw" see "Weighted Computed Tomography Dose Index (CTDIw)"
"CT x-ray system" is technology that is used to perform CT scans and includes, but is not limited to: a control panel; image display device; gantry; x-ray tube; collimating device with filters; high voltage transformer; and, a data acquisition system. This includes CBCT systems that are used for other than dental x-ray scans.
"CT scanner" refers to technology used to perform and interpret CT scans and includes, but is not limited to: a control panel; gantry; high voltage generator; x-ray tube; table; and, display devices that are used for image interpretation.
"Cumulative air kerma" means the total air kerma accrued from the beginning of an examination or procedure and includes all contributions from fluoroscopic and radiographic irradiation.
"Dead-man switch" means a switch so constructed that a circuit closing contact can be maintained only by continuous pressure on the switch by the operator.
"Detector" has the same meaning as "radiation detector."
"Declared pregnant worker" means a worker who has voluntarily informed their employer, in writing, of their pregnancy and the estimated date of conception. The declaration remains in effect until the declared pregnant worker withdraws the declaration in writing or is no longer pregnant.
"Department" means the New York City Department of Health and Mental Hygiene.
"Diagnostic source assembly" means the tube housing assembly with a beam-limiting device attached.
"Diagnostic x-ray system" means an x-ray system designed for irradiation of any part of the human or animal body for the purpose of diagnosis or visualization.
"Diaphragm" means a device or mechanism by which the radiation beam is restricted in size.
"Digital radiography (DR)" means an x-ray imaging method or radiography which produces a digital rather than analog image. DR includes both computed radiography and direct digital radiography.
"Direct digital radiography (DDR)" means an x-ray imaging method in which a digital sensor, usually incorporating a thin-film transistor, is used to capture an x-ray image. Some DDR systems use a scintillator to convert x-rays to light and a photodiode array to convert light to charge, while others use a photoconductor to convert x-rays directly to charge, which is stored on the thin-film transistor. See also the definitions of "computed radiography" and "digital radiography."
"Direct scattered radiation" or "direct scatter radiation" means that scattered radiation which has been deviated in direction only by materials irradiated by the useful beam. See also the definition of "scattered radiation."
"Direct personal supervision" means that the qualified practitioner must be present in the room when the procedure is being performed and is immediately available to provide assistance and direction throughout the performance of the procedure.
"Direct supervision" means a qualified practitioner must exercise general supervision and be present in the facility and immediately available to furnish assistance and direction throughout the performance of the procedure. It does not mean that the qualified practitioner must be present in the room when the procedure is being performed.
"Dose" means the absorbed dose.
"Dose equivalent" means the product of the absorbed dose in tissue, quality factor, and all other necessary modifying factors, at the location of interest. Appropriate quality factors may be found in 10 C.F.R. § 20.2004.
"Dose area product (DAP) or "kerma-area product (KAP)" means the product of the air kerma and the area of the irradiated field and is typically expressed in Gy-cm 2 , so it does not change with distance from the x-ray tube.
"Dose length product (DLP)" means the indicator of the integrated radiation dose from a complete CT examination. It addresses the total scan length by the formula:
DLP (mGy-cm) = CTDIvol (mGy) x scan length (cm)
"Dose monitor unit (DMU)" means a unit response from the beam monitoring system from which the absorbed dose can be calculated.
"Dose profile" means the dose as a function of position along a line.
"Effective dose equivalent" is the sum of the products of the dose equivalent to the organ or tissue (HT) and the weighting factors (WT) applicable to each of the body organs or tissues that are irradiated: HE = S (WT HT).
"Electronic brachytherapy" means a method of radiation therapy where an electrically generated source of ionizing radiation is placed in or near the tumor or target tissue to deliver therapeutic radiation dosage.
"Electronic brachytherapy device" means the system used to produce and deliver therapeutic radiation including the x-ray tube, the control mechanism, the cooling system, and the power source.
"Electronic brachytherapy source" means the x-ray tube component used in an electronic brachytherapy device.
"Emergency procedure" means the written pre-planned steps to be taken in the event of actual or suspected exposure of an individual in excess of administrative or regulatory limits including the names and telephone numbers of individuals to be contacted.
"Equipment" means x-ray equipment, unless the specific context clearly indicates otherwise.
"Exposure rate" means exposure per unit of time, such as roentgen per minute. For purposes of this definition, "exposure" means the quotient dQ/dm, where dQ is the absolute value of the total charge of the ions of one sign produced in air and dm is the mass of air.
"External beam radiation therapy" means therapeutic irradiation in which the source of radiation is at a distance from the body.
"Extremity" means hand, elbow, arm below the elbow, foot, knee and leg below the knee.
"Facility" means the location, building, vehicle, or complex under one administrative control, at which one or more radiation machines are installed, located or used.
"Field of view (FOV)" means, in fluoroscopy, the diameter for circular image receptors or the diagonal for rectangular image receptors.
"Field emission equipment" means equipment which uses an x-ray tube in which electron emission from the cathode is due solely to the action of an electric field.
"Field-flattening filter" means a filter used to homogenize the absorbed dose rate over the radiation field.
"Filter" means material placed in the useful beam to preferentially absorb selected radiations.
"Fluoroscopic imaging assembly" means a subsystem in which x-ray photons produce a set of fluoroscopic images or radiographic images recorded from the fluoroscopic image receptor. It includes image receptors, electrical interlocks, if any, and structural material providing linkage between the image receptor and diagnostic source assembly.
"Fluoroscopic irradiation time" means the cumulative duration during an examination or procedure of operator-applied continuous pressure to the device, enabling x-ray tube activation in any fluoroscopic mode of operation.
"Fluoroscopically-Guided Interventional (FGI) procedures" means an interventional diagnostic or therapeutic procedure performed via percutaneous or other access routes, usually with local anesthesia or intravenous sedation, which uses external ionizing radiation in the form of fluoroscopy to localize or characterize a lesion, diagnostic site, or treatment site, to monitor the procedure, and to control and document therapy.
"Fluoroscopy" means a technique for generating x-ray images and presenting them simultaneously and continuously as visible images. This term has the same meaning as the term "radioscopy" in the standards of the International Electrotechnical Commission.
"Focal spot" means the area projected on the anode of the x-ray tube bombarded by the electrons accelerated from the cathode and from which the useful beam originates.
"Gantry" means that part of a radiation therapy system supporting and allowing movements of the radiation head about a center of rotation. For computed tomography, "gantry" means tube housing assemblies, beam-limiting devices, detectors, and the supporting structures, frames, and covers which hold or enclose these components within a computed tomography system.
"General purpose radiographic x-ray system" means any radiographic x-ray system which, by design, is not limited to radiographic examination of specific anatomical regions.
"General supervision" means the procedure is performed under the overall direction and control of the qualified practitioner but who is not necessarily required to be physically present during the performance of the procedure.
"Gonad shield" or "gonadal shield" means a protective barrier for the ovaries or testes.
"Gray (Gy)" means the SI unit of absorbed dose, kerma, and specific energy imparted equal to 1 joule per kilogram. Also see "Absorbed Dose".
"Half-value layer (HVL)" means the thickness of specified material which attenuates the beam of radiation to an extent such that the AKR is reduced by one-half of its original value. For the purposes of this definition, the contribution of all scattered radiation, other than any which might be present initially in the beam concerned, is deemed to be excluded.
"Hand-held x-ray equipment" or "hand-held x-ray system" means x-ray equipment that is designed to be hand-held during operation.
"Healing arts" means the use of radiation for purposes of medical diagnosis or treatment of humans or animals.
"Healing arts screening" means the testing of human beings using x-ray machines for the detection or evaluation of health indications when such tests are not specifically and individually ordered by a licensed practitioner of the healing arts legally authorized to prescribe such x-ray tests for the purpose of diagnosis or treatment.
"Image intensifier" means a device, installed in its housing, which instantaneously converts an x- ray pattern, in an analog fashion, into a corresponding light image of higher intensity.
"Image receptor" means any device, such as a fluorescent screen, radiographic film, x-ray image intensifier tube, solid-state detector, or gaseous detector which transforms incident x-ray photons either into a visible image or into another form which can be made into a visible image by further transformations. In those cases where means are provided to preselect a portion of the image receptor, the term "image receptor" shall mean the preselected portion of the device.
"Individual monitoring devices" ""means devices designed to be worn by a single individual for the assessment of effective dose equivalent, such as film badges, thermo-luminescent dosimeters (TLDs), optically-stimulated luminescent dosimeters (OSLDs), pocket ionization chambers etc.
"Inherent filtration" means the filtration of the useful beam provided by the permanently installed components of the tube housing assembly.
"Inspection" means an official examination or facility observation including, but not limited to, reviews of tests, reports, assessments, specifications, surveys and monitoring to determine compliance with applicable rules, regulations, orders, requirements and conditions enforceable by the Department.
"Intensity Modulated Radiation Therapy (IMRT)" means radiation therapy that uses non-uniform radiation beam intensities which have been determined by various computer-based optimization techniques.
"Interlock" means a device or engineered system that precludes access to an area of radiation hazard either by preventing entry or by automatically removing the hazard.
"Interruption of irradiation" means the stopping of irradiation with the possibility of continuing irradiation without resetting of operating conditions at the control panel.
"Irradiation" means the exposure of matter to ionizing radiation.
"Isocenter" means the center of the smallest sphere through which the beam axis passes when the equipment moves through a full range of rotations about its common center.
"Kerma" means the quantity defined by the International Commission on Radiation Units and Measurements. The kerma, K, is the quotient of dEtr by dm, where dEtr is the sum of the initial kinetic energies of all the charged particles liberated by uncharged particles in a mass dm of material; thus K=dEtr/dm, in units of J/kg, where the special name for the unit of kerma is gray (Gy). When the material is air, the quantity is referred to as "air kerma." "Kerma-area product (KAP)" has the same meaning as "dose area product."
"Kilovolt (kV)" or "(kilo electron volt (keV))" means the energy equal to that acquired by a particle with one electron charge in passing through a potential difference of 1,000 volts in a vacuum. (Note: current convention is to use kV for photons and keV for electrons.)
"Kilovolt peak (kVp)" means the maximum value in kilovolts of the potential difference of a pulsating generator. When only one-half of the wave is used, the value refers to the useful half of the wave.
"kWs" means kilowatt second.
"Last-image hold (LIH) radiograph" means an image obtained either by retaining one or more fluoroscopic images, which may be temporarily integrated, at the end of a fluoroscopic exposure or by initiating a separate and distinct radiographic exposure automatically and immediately in conjunction with termination of the fluoroscopic exposure.
"Lead equivalent" means the thickness of lead affording the same attenuation, under specified conditions, as the material in question.
"Leakage radiation" means all radiation coming from within the source housing, except the useful beam or radiation produced when the exposure switch or timer is not activated.
"Leakage technique factors" means the technique factors associated with the diagnostic source assembly which are used in measuring leakage radiation and defined as follows:
(a) For diagnostic source assemblies intended for capacitor energy storage equipment, the maximum-rated peak tube potential and the maximum-rated number of exposures in an hour for operation at the maximum-rated peak tube potential with the quantity of charge per exposure being 10 millicoulombs (or 10 mAs) or the minimum obtainable from the unit, whichever is larger;
(b) For diagnostic source assemblies intended for field emission equipment rated for pulsed operation, the maximum-rated peak tube potential and the maximum-rated number of x- ray pulses in an hour for operation at the maximum-rated peak tube potential; and
(c) For all other diagnostic source assemblies, the maximum-rated peak tube potential and the maximum-rated continuous tube current for the maximum-rated peak tube potential.
"Licensed radiologic technologist (LRT)" means an individual who is licensed and operates in compliance with Article 35 of the New York State Public Health Law and Part 89 of Title 10 of the New York Articles, Rules and Regulations, or any successor law or regulations.
"Licensee" means any person who is licensed by the Department in accordance with this Article or any person who possesses radioactive material which is subject to the licensure requirements of this Article.
"Light field" means that area of the intersection of the light beam from the beam-limiting device and one of the set of planes parallel to and including the plane of the image receptor, whose perimeter is the locus of points at which the illumination visually appears to be approximately one-fourth of the maximum in the intersection.
"Limited-use system" means a personnel screening system that is capable of delivering an effective dose equivalent greater than 0.25 µSv (25 µrem) per screening but cannot exceed an effective dose equivalent of 10 µSv (1 mrem) per screening. Limited-use systems require additional controls and documentation to ensure that annual individual dose limits required by H.12e. appropriate regulations or national standards are not exceeded.
"Line-voltage regulation" means the difference between the no-load and the load line potentials expressed as a percent of the load line potential:
Percent line-voltage regulation = 100 (V n - V l ) / V l )
where:
V n = No-load line potential; and
V l = Load line potential.
"mA" means milliampere.
"mAs" means milliampere second.
"Medical event" means a situation (except for an event that results from patient intervention) in which the administration of radiation from any radiation source results in:
(a) a dose that differs from the prescribed dose by more than 0.05 Sv (5 rem) effective dose equivalent, 0.5 Sv (50 rem) to an organ or tissue, or 0.5 Sv (50 rem) shallow dose equivalent to the skin; and
(1) the total dose delivered differs from the prescribed dose by 20 percent or more; or
(2) the fractionated dose delivered differs from the prescribed dose, for a single fraction, by 50 percent or more.
(b) a dose that exceeds 0.05 Sv (5 rem) effective dose equivalent, 0.5 Sv (50 rem) to an organ or tissue, or 0.5 Sv (50 rem) shallow dose equivalent to the skin from any of the following:
(1) an administration of a dose to the wrong individual or human research subject;
(2) an administration of a dose delivered by the wrong mode of treatment.
(c) a dose to the skin or an organ or tissue other than the treatment site that exceeds by 0.5 Sv (50 rem) to an organ or tissue and 50 percent or more of the dose expected from the administration defined in the written directive;
(d) the administration of a CT or CBCT scan in which any of the following occur:
(1) a CT or CBCT scan is performed on the wrong person;
(2) a CT or CBCT scan is performed on the wrong body part, such that the patient dose from the scan to the wrong body part results in an effective dose equivalent exceeding 2.5 mSv (250 mrem), or 50 mSv (5 rem) to an organ or tissue;
(3) a CT or CBCT scan that results in damage to an organ, organ system or results in hair loss or erythema as determined by a physician; or
(e) Any event resulting from intervention of a patient or human research subject in which the radiation from any radiation source results or will result in unintended permanent functional damage to an organ or a physiological system, as determined by a physician.
"Medical institution" means a "hospital" as defined in New York State Public Health Law § 2801(1).
"Megavolt (MV)" or "mega electron volt (MeV)" means the energy equal to that acquired by a particle with one electron charge in passing through a potential difference of 1,000,000 volts in a vacuum. (Note: current convention is to use MV for photons and MeV for electrons.)
"Minor" means an individual less than 18 years of age.
"Mobile electronic brachytherapy service" means transportation of an electronic brachytherapy device to provide electronic brachytherapy at an address that is not the address of record.
"Mobile x-ray equipment" has the meaning ascribed to it in the definition of "x-ray equipment."
"Mode of operation" means, for fluoroscopic systems, a distinct method of fluoroscopy or radiography provided by the manufacturer and selected with a set of several technique factors or other control settings uniquely associated with the mode. The set of distinct technique factors and control settings for the mode may be selected by the operation of a single control. Examples of distinct modes of operation include normal fluoroscopy (analog or digital), high-level control fluoroscopy, cineradiography (analog and digital), digital subtraction angiography, electronic radiography using the fluoroscopic image receptor, and spot film recording. In a specific mode of operation, certain system variables affecting kerma, AKR, or image quality, such as image magnification, x-ray field size, pulse rate, pulse duration, number of pulses, source-image receptor distance (SID), or optical aperture, may be adjustable or may vary; their variation per se does not comprise a mode of operation different from the one that has been selected.
"Monitor unit (MU)" has the same meaning as "dose monitor unit."
"Monthly" means at least once per calendar month.
"Moving beam radiation therapy" means radiation therapy with any planned displacement of radiation field or patient relative to each other, or with any planned change of absorbed dose distribution. It includes arc, skip, conformal, intensity modulation and rotational therapy.
"Noise" in CT means the standard deviation of the fluctuations in CT number expressed as a percentage of the attenuation coefficient of water. Its estimate (Sn) is calculated using the following expression:
where:
CS = Linear attenuation coefficient of the material of interest.
µ W = Linear attenuation coefficient of water.
s = Estimated [S]standard deviation of the CT numbers of picture elements in a specified area of the CT image.
"Nominal tomographic section thickness" means the full width at half-maximum of the sensitivity profile taken at the center of the cross-sectional volume over which x-ray transmission data are collected.
"Nominal treatment distance" means:
(a) for electron irradiation, the distance from the scattering foil, virtual source, or exit window of the electron beam to the entrance surface of the irradiated object along the central axis of the useful beam.
(b) for x-ray irradiation, the virtual source or target to isocenter distance along the central axis of the useful beam. For non-isocentric equipment, this distance shall be that specified by the manufacturer.
"Normal operating procedures" mean step-by-step instructions necessary to accomplish the task. These procedures may include sample insertion and manipulation, equipment alignment, routine maintenance by the registrant, and data recording procedures, which are related to radiation safety.
"Occupational dose" means the dose received by an individual in the course of employment in which the individual's assigned duties involve exposure to radiation or to radioactive material from licensed and unlicensed sources of radiation, whether in the possession of the licensee, registrant, or other person. Occupational dose does not include doses received from background radiation, from any medical administration the individual has received, from exposure to individuals administered radioactive material or implants and released from voluntary participation in medical research programs, or as a member of the public.
"Open-beam x-ray equipment" means an x-ray system in which the beam path could be entered by any part of the body at any time.
"Patient" means an individual or animal subjected to healing arts examination, diagnosis or treatment or machine-produced radiation for the purposes of medical therapy.
"Patient intervention" means actions by the patient or human research subject, whether intentional or unintentional, such as dislodging or removing treatment devices or prematurely terminating the administration.
"Peak tube potential" means the maximum value of the potential difference across the x-ray tube during an exposure.
"Periodic quality assurance check" means a procedure which is performed to ensure that a previous parameter or condition continues to be valid.
"Personal supervision" means a qualified practitioner must exercise "general supervision" (as defined in this Article) and be present in the room or adjacent control area during the performance of the procedure.
"PBL" (See "Positive beam limitation").
"Person" means, notwithstanding 24 RCNY Health Code § 1.03, any individual, corporation, partnership, firm, association, trust, estate, public or private institution, group, agency, political subdivision of this State, any other State or political subdivision or agency thereof, and any legal successor, representative, agent, or agency of the foregoing. For purposes of entities other than individual professional practitioners applying to this Department for the issuance of a radiation equipment registration or radioactive materials license, "person" shall mean only a principal officer, director or executive of the applying entity with authority to legally bind the applying entity to the obligations attendant to such registration or license.
"Phantom" means a test object either used to determine system characteristics or to evaluate system performance. The composition and design of a phantom varies based on the modality and test it is used for.
"Photostimulable storage phosphor (PSP)" means a material used to capture and store radiographic images in computed radiography systems.
"Picture Archiving and Communication System (PACS)" is a medical imaging technology that provides access to and storage for medical images from multiple modalities. It is comprised of an image acquisition system, display, network and data storage or archiving system.
"Picture element" means an elemental area of a tomogram.
"PID" has the same meaning as "position indicating device".
"Pitch" means the table incrementation, per x-ray tube rotation, divided by the nominal x-ray beam width at isocenter.
"Portable x-ray equipment" has the meaning ascribed to it in the definition of "x-ray equipment."
"Position indicating device (PID)" means a device on dental x-ray equipment used to indicate the beam position and to establish a definite source-surface (skin) distance. It may or may not incorporate or serve as a beam-limiting device.
"Positive beam limitation" means the automatic or semi-automatic adjustment of an x-ray beam to the size of the selected image receptor, whereby exposures cannot be made without such adjustment.
"Prescribed dose" means the total dose and dose per fraction as documented in the written directive by a medical doctor.
"Primary beam" means the ionizing radiation coming directly from the radiation source through a beam port into the volume defined by the collimation system.
"Primary dose monitoring system" means a system which will monitor the useful beam during irradiation and which will terminate irradiation when a pre-selected number of dose monitor units have been delivered.
"Primary protective barrier" see "Protective barrier"
"Professional practice" means the practice of medicine, dentistry, podiatry, osteopathy, chiropractic or veterinary medicine.
"Professional practitioner" means any person licensed or otherwise authorized under the Education Law to operate a professional practice.
"Protective barrier" means a barrier of radiation absorbing material used to reduce radiation exposure. The types of protective barriers are:
(a) "primary protective barrier" or "primary barrier" means the material, excluding filters, placed in the useful beam.
(b) "secondary protective barrier" or "secondary barrier" means the material which attenuates stray radiation.
"Protective garment" means an apron, glove, thyroid shield or other protective barrier worn by a professional practitioner or licensed radiographic technologist or patient made of radiation attenuating material, used to reduce radiation exposure.
"Protocol" means a collection of settings and parameters that fully describe an examination.
"Pulsed mode" means operation of the x-ray system such that the x-ray tube current is pulsed by the x-ray control to produce one or more exposure intervals of duration less than one-half second.
"Qualified Medical Physicist (QMP)" means an individual who:
(a) is licensed and maintains a current registration in accordance with Article 166 of the New York State Education Law and applicable regulations to practice any subspecialty of medical physics; and
(b) for certified registrations, is listed on the certified registration and has been granted certification in a specific subfield of medical physics by an appropriate national certifying body and abides by the certifying body's requirements for continuing education.
"Quality Assurance (QA)" means a program providing for verification by written procedures, such as testing, auditing and inspection, to ensure that deficiencies, deviations, defective equipment, unsafe practices, or a combination thereof, relating to the use, disposal, management, or manufacture of radiation equipment or radioactive material, are identified, promptly corrected and reported to the appropriate regulatory authorities as required.
"Quarterly" means an activity is done at least once in every third month, before the last business day or the end of the month, whichever comes first.
"Rad" means the special unit of absorbed dose. One rad is equal to an absorbed dose of 100 ergs per gram or 0.01 joule per kilogram (0.01 gray).
"Radiation" means alpha particles, beta particles, gamma rays, x rays, neutrons, high-speed electrons, high-speed protons, and other particles capable of producing ions. For purposes of this Article, ionizing radiation is an equivalent term. As used in this Article, radiation does not include non-ionizing radiation, such as radiowaves or microwaves, visible, infrared or ultraviolet light.
"Radiation detector" means a device which in the presence of radiation provides a signal or other indication suitable for use in measuring one or more quantities of incident radiation.
"Radiation head" means the structure from which the useful beam emerges.
"Radiation installation" means any location of radiation-producing equipment subject to this Article.
"Radiation Protocol Committee (RPC)" means the representative group of qualified individuals in a CT or FGI facility responsible for the ongoing review and management of CT or FGI protocols to ensure that exams being performed achieve the desired diagnostic image quality at the lowest radiation dose possible while properly exploiting the capabilities of the equipment being used. This committee and these functions may be subsumed under the registrant's radiation safety committee as described in 24 RCNY Health Code § 175.09(e).
"Radiation safety officer (RSO)" means an individual described in 24 RCNY Health Code § 175.10.
"Radiation source" means any radioactive material or any radiation equipment.
"Radiation source housing" or "x-ray tube housing" means that portion of an x-ray system which contains the x-ray tube or secondary target. Often the housing contains radiation shielding material or inherently provides shielding.
"Radiation therapy simulation system" means a radiographic or fluoroscopic x-ray system intended for localizing the volume to be exposed during radiation therapy and confirming the position and size of the therapeutic irradiation field.
"Radioactive material" means any solid, liquid or gas which emits radiation spontaneously.
"Radiograph" means an image receptor on which the image is created directly or indirectly by an x-ray pattern and results in a permanent record, permanent film or a digital image produced on a sensitive surface by a form of radiation other than direct visible light.
"Radiography" means a technique for generating and recording an x-ray pattern for the purpose of providing the user with an image after termination of the exposure; the process of creating radiographic images.
"Recording" means producing a retrievable form of an image resulting from x-ray photons.
"Redundant beam monitoring system" means a combination of two independent dose monitoring systems in which each system is designed to terminate irradiation in accordance with a pre- selected number of dose monitor units.
"Reference level" means dose levels in medical radio-diagnostic practices for typical examinations for groups of standard-sized patients or standard phantoms for broadly defined types of equipment.
"Registrant" means an individual or entity issued a certificate of registration, or certified registration, from the Department to operate registered radiation equipment.
"Rem" means the special unit of any of the quantities expressed as dose equivalent. The dose equivalent in rem is equal to the absorbed dose in rad multiplied by the quality factor. One rem is equal to 0.01 sievert.
"Roentgen (R)" Means the special unit of exposure. One roentgen equals 2.58E-4 coulomb per kilogram of air.
"Restricted area" means an area, access to which is limited for the purpose of protecting individuals against undue risks from exposure to sources of radiation. A restricted area does not include any area used as residential quarters (but separate rooms in a residential building may be set apart as a restricted area).
"Safety device" means a device, interlock or system that prevents the entry of any portion of an individual's body into the primary x-ray beam or that causes the beam to shut off upon entry into its path.
"Scan" means the complete process of collecting x-ray transmission data for the production of a tomogram. Data may be collected simultaneously during a single scan for the production of one or more tomograms.
"Scan increment" means the amount of relative displacement of the patient with respect to the CT x-ray system between successive scans measured along the direction of such displacement.
"Scan sequence" means a pre-selected set of two or more scans performed consecutively under pre-selected CT conditions of operation.
"Scan time" means the time elapsed during the accumulation of x-ray transmission data for a single scan.
"Scattered radiation" or "scatter radiation" means radiation that has been deviated in direction or energy by passing through matter.
"Screening" means the application of x-ray radiation to diagnose a particular condition, as in the application of mammography x-rays to a female population to diagnosis the incidence of breast cancer.
"Sealed x-ray units" means any x-ray unit to which the Department affixes warning labels to in order to notify the registrant that the x-ray unit shall not be used for clinical x-ray exams.
"Secondary dose monitoring system" means a system which will terminate irradiation in the event of failure of the primary dose monitoring system.
"Semi-annual" means an activity is performed once within every sixth month before the end of the last business day or the end of the month, whichever comes first.
"Sensitivity profile" means the relative response of the CT x-ray system as a function of position along a line perpendicular to the tomographic plane.
"Shutter" means a moveable device attached to the tube housing assembly which can intercept the entire cross sectional area of the useful beam and which has a lead equivalency not less than that of the tube housing assembly and is used to block the useful or primary beam emitted from an x-ray tube assembly.
"SI" means the International System of Units, usually abbreviated "SI" and refers to the modern metric system of measurement.
"SID" has the same meaning as "source-image receptor distance."
"Sievert (Sv)" means the SI unit of dose equivalent. The unit of dose equivalent is the joule per kilogram. The previously used ("traditional") unit of dose equivalent is the rem. (1 Sv=100 rem).
"Simulator (radiation therapy simulation system)" means any x-ray system intended for localizing the volume to be exposed during radiation therapy and establishing the position and size of the therapeutic irradiation field. See also the definitions of conventional simulator" and "virtual simulator."
"Skyshine" means radiation, such as neutrons and photons, generated by high energy proton accelerators over 10 MeV, which can be scattered by the atmosphere near the facility and result in public exposure as a scattered dose.
"Source" means the region or material from which the radiation emanates, for example, the focal spot of an x-ray tube.
"Source-image receptor distance (SID)" means the distance from the source to the center of the input surface of the image receptor.
"Source-skin distance (SSD)" means the distance from the source to the center of the entrant x- ray field in the plane tangent to the patient skin surface.
"Spot-film" means a cassette-based radiograph which is made during a fluoroscopic examination to permanently record a relevant image visible during that fluoroscopic procedure.
"Spot-film device" means a device intended to transport or position a radiographic image receptor between the x-ray source and fluoroscopic image receptor. It includes a device intended to hold a cassette over the input end of the fluoroscopic image receptor for the purpose of producing a radiograph.
"Stationary beam radiation therapy" means radiation therapy without displacement of one or more mechanical axes relative to the patient during irradiation.
"Storage" means a condition in which a device or source is not being used for an extended period of time, and has been made inoperable.
"Stray radiation" means the sum of leakage and scatter radiation.
"Substantial radiation dose level (SRDL)" means an appropriately-selected dose used to trigger additional dose-management actions during a procedure and medical follow-up for a radiation level that might produce a clinically-relevant injury in an average patient.
"Target" means that part of an x-ray tube or accelerator onto which a beam of accelerated particles is directed to produce ionizing radiation or other particles.
"Target-skin distance (TSD)" means the distance measured along the beam axis from the center of the front surface of the x-ray target or electron virtual source to the surface of the irradiated object or patient.
"Technique" means the settings selected on the control panel of the equipment.
"Technique chart" means a chart that lists the standard settings and positions for a given technique.
"Technique factors" means the conditions of operation displayed by the x-ray equipment, such as:
(a) for capacitor energy storage equipment, peak tube potential in kilovolts (kV) and quantity of charge in milliampere-seconds (mAs);
(b) for field emission equipment rated for pulsed operation, peak tube potential in kV, and number of x-ray pulses;
(c) for CT equipment designed for pulsed operation, peak tube potential in kV, scan time in seconds, and either tube current in milliamperes (mA), x-ray pulse width in seconds, and the number of x-ray pulses per scan, or the product of tube current, x-ray pulse width, and the number of x-ray pulses in mAs;
(d) for CT equipment not designed for pulsed operation, peak tube potential in kV, and either tube current in mA and scan time in seconds, or the product of tube current and exposure time in mAs and the scan time when the scan time and exposure time are equivalent. Based on the manufacturer, the time-current product may be scaled by other scan parameters like the pitch; and
(e) for all other equipment, peak tube potential in kV, and either tube current in mA and exposure time in seconds, or the product of tube current and exposure time in mAs.
"Tenth-value layer (TVL)" means the thickness of a specified material which attenuates x- radiation or gamma radiation to an extent such that the air kerma rate, exposure rate, or absorbed dose rate is reduced to one-tenth of the value measured without the material at the same point.
"Termination of irradiation" means the stopping of irradiation in a fashion which will not permit continuance of irradiation without the resetting of operating conditions at the control panel.
"Test" means the process of verifying compliance with an applicable standard or requirement.
"Therapeutic radiation machine" means photon or charged particle-producing equipment designed and used for external beam radiation therapy. For purposes of this Article, devices used to administer electronic brachytherapy or superficial photon or charged particle therapy shall also be considered therapeutic radiation machines.
"This Article" means 24 RCNY Health Code Article 175 and all other parts of the New York City Health Code applicable to licensees and registrants or other persons subject to the provisions of 24 RCNY Health Code Article 175, including but not limited to 24 RCNY Health Code Articles 1, 3 and 5.
"Tomogram" means the depiction of the x-ray attenuation properties of a section through the body.
"Tomographic plane" means that geometric plane which the manufacturer identified as corresponding to the output tomogram.
"Tomographic section" means the volume of an object whose x-ray attenuation properties are imaged in a tomogram.
"Total Effective Dose Equivalent (TEDE)" means the sum of the effective dose equivalent (for external exposures) and the committed effective dose equivalent (for internal exposures; committed effective dose equivalent is a measure of dose that will be received from intake of radioactive material).
"Tube" means an x-ray tube, unless otherwise specified.
"Tube housing assembly" means the tube housing with tube installed. It includes high-voltage or filament transformers and other appropriate elements when such are contained within the tube housing.
"Unintended" radiation dose in diagnostic or interventional x-ray means a patient radiation dose resulting from a human error or equipment malfunction during the procedure.
"Useful beam" means the radiation which passes through the tube housing port and the aperture of the beam limiting device when the exposure switch or timer is activated to cause the radiation machine to produce radiation.
"Virtual simulator" means a computed tomography (CT) unit used in conjunction with relevant software which recreates the treatment machine; and that allows import, manipulation, display, and storage of images from CT or other imaging modalities.
"Virtual source" means a point from which radiation appears to originate.
"Visible area" means that portion of the input surface of the image receptor over which incident x-ray photons are producing a visible image.
"Volume Computed Tomography Dose Index (CTDIvol)" means a radiation dose parameter derived from the CTDIw (weighted or average CTDI given across the field of view). The formula is:
CTDIvol = (N)(T)(CTDIw)/I
where:
N = number of simultaneous axial scans per x-ray source rotation,
T = thickness of one axial scan (mm), and
I = table increment per axial scan (mm).
Thus,
CTDIvol = CTDIw / pitch
"Warning device" means a visible or audible signal that warns individuals of a potential radiation hazard.
"Wedge filter" means a filter which effects continuous change in transmission over all or a part of the useful beam.
"Weighting factor WT " for an organ or tissue (T) means the proportion of the risk of stochastic effects resulting from irradiation of that organ or tissue to the total risk of stochastic effects when the whole body is irradiated uniformly. For calculating the effective dose equivalent, the values of W T are:
Organ Dose Weighing Factors Organ or Tissue W T Gonads 0.25 Breast 0.15 Red bone marrow 0.12 Lung 0.12 Thyroid 0.03 Bone surfaces 0.03 Remainder 0.30 1 Whole body 1.00 2
1 0.30 results from 0.06 for each of 5 "remainder" organs, excluding the skin and the lens of the eye, that receive the highest doses.
2 For the purpose of weighting the external whole body dose, for adding it to the internal dose, a single weighting factor, W T = 1.0, has been specified. The use of other weighting factors for external exposure will be approved on a case-by-case basis until such time as specific guidance is issued.
"Weekly" means at least once per week, where a week means seven consecutive days starting on Sunday.
"Whole body" means, for purposes of external exposure, head, trunk (including male gonads), arms above the elbow, or legs above the knee.
"Written directive" means an order in writing for the administration of radiation to a specific patient or human research subject.
"Weighted Computed Tomography Dose Index (CTDIw)" means the estimated average CTDI100 across the field of view (FOV). The equation is:
CTDI w = 1/3(CTDI 100, center ) + 2/3(CTDI 100, edge )
where, 1/3 and 2/3 approximate the relative areas represented by the center and edge values derived using the 16 or 32 cm acrylic phantom. CTDIw uses CTDI100 and an f-factor for air (0.87 rad/R or 1.0 mGy/mGy).
"X-ray control" means a device which controls input power to the x-ray high-voltage generator or the x-ray tube. It includes equipment such as timers, phototimers, automatic brightness stabilizers, and similar devices, which control the technique factors of an x-ray exposure.
"X-ray exposure control" means a device, switch, button or other similar means by which an operator initiates or terminates the radiation exposure. The x-ray exposure control may include such associated equipment as timers and back-up timers.
"X-ray equipment" means an x-ray system, subsystem, or component thereof. Types of x-ray equipment are as follows:
(a) "mobile x-ray equipment" means x-ray equipment mounted on a permanent base with wheels or casters for moving while completely assembled.
(b) "portable x-ray equipment" means x-ray equipment designed to be hand-carried.
(c) "stationary x-ray equipment" means x-ray equipment which is installed in a fixed location. (d) "hand-held x-ray equipment" means x-ray equipment that is designed to be hand- held during operation.
"X-ray field" means that area of the intersection of the useful beam and any one of a set of planes parallel to and including the plane of the image receptor, whose perimeter is the locus of points at which the AKR is one-fourth of the maximum in the intersection. On recording devices that visualize the x-ray field, the perimeter can be taken to be the locus of points at which the brightness as it visually appears to the observer is approximately one-fourth of the maximum brightness in the intersection.
"X-ray high-voltage generator" or "x-ray generator" means a device which transforms electrical energy from the potential supplied by the x-ray control to the tube operating potential. The device may also include means for transforming alternating current to direct current, filament transformers for the x-ray tube, high-voltage switches, electrical protective devices, and other appropriate elements.
"X-ray system" means an assemblage of components for the controlled production of x-rays. It includes minimally an x-ray high-voltage generator, an x-ray control, a tube housing assembly, a beam-limiting device, and the necessary supporting structures. Additional components which function with the system are considered integral parts of the system.
"X-ray table" means a patient support device with its patient support structure (tabletop) interposed between the patient and the image receptor during radiography or fluoroscopy. This includes, but is not limited to, any stretcher equipped with a radiolucent panel and any table equipped with a cassette tray (or bucky), cassette tunnel, fluoroscopic image receptor, or spot- film device beneath the tabletop.
"X-ray tube" means any electron tube which is designed for the conversion of electrical energy into x-ray energy.
(Added City Record 4/24/2019, eff. 5/24/2019)
§ 175.09. Radiation Protection Programs
Each registrant must at a minimum:
(a) develop, document and implement a radiation protection program commensurate with the scope and extent of their operations and sufficient to ensure compliance with the provisions of this Article. The radiation safety program must include, but not be limited to, the following policies, procedures and activities:
(1) that the use of ionizing radiation within its purview is performed in accordance with existing laws and regulations; this requirement shall be deemed to be met by the registrant possessing a Quality Assurance Manual in accordance with 24 RCNY Health Code § 175.12 for the facility.
(2) that all persons are protected from radiation as required by this Article. A current and readily-accessible copy of 24 RCNY Health Code Article 175 must be maintained by the registrant at the facility either in hard copy or electronic format.
(3) that upon discovery of a medical event, the registrant must follow the applicable requirements of 24 RCNY Health Code §§ 175.25 and 175.26 concerning required notifications and reports.
(b) use, to the extent practical, procedures and engineering controls based upon 'best practice' radiation protection principles to achieve occupational doses and doses to members of the public that are as low as reasonably achievable (ALARA) below the limits specified in this Article.
(c) provide a radiation safety officer pursuant to 24 RCNY Health Code § 175.10 who shall be delegated authority to ensure the implementation of this radiation protection program.
(d) provide a quality assurance program pursuant to 24 RCNY Health Code § 175.12 for diagnostic and therapeutic uses of radiation-producing equipment operated under applicable provisions of this Article.
(e) for medical centers, hospitals and institutions of higher education, provide for a radiation safety committee to administer the radiation protection program. The radiation safety committee must include the facility operator or a person with the authority to act on behalf of the facility operator, and representation from departments within the facility where radiation sources are used. The committee shall oversee all uses of radiation-producing equipment and radioactive materials within the facility, shall review the activities of the radiation safety officer and shall review the radiation safety program at least annually. The committee, or a subcommittee, shall oversee the administration of the required quality assurance program.
(f) ensure that radiation equipment is used only for those procedures for which it is designed by individuals duly-licensed and fully-qualified to operate such equipment.
(g) ensure that acceptance testing, by a QMP, is performed on all medical and chiropractic diagnostic equipment and radiation therapy treatment and planning equipment before the first use of such equipment on humans; and
(h) at least every 12 months, review the radiation protection program content and its implementation.
(Added City Record 4/24/2019, eff. 5/24/2019)
§ 175.10. Radiation Safety Officer
(a) In addition to those requirements indicated in this section for specific categories, all radiation safety officers must:
(1) demonstrate knowledge of potential radiation hazards and emergency precautions; and
(2) have completed educational courses related to ionizing radiation safety or a radiation safety officer course; and
(3) demonstrate experience in the use and familiarity of the type of equipment used.
(b) Specific duties of the radiation safety officer include, but are not limited to:
(1) establishing and overseeing operating and safety procedures that maintain radiation exposures as low as reasonably achievable (ALARA), and to review them regularly to ensure that the procedures are current and conform with this Article;
(2) ensuring that individual monitoring devices are properly used by occupationally-exposed personnel, that records are kept of the monitoring results, and that timely notifications are made as required by this Article;
(3) investigating and reporting to the Department each known or suspected case of radiation exposure to an individual or radiation level detected in excess of limits established by this Article and each theft or loss of a source of radiation, determining the cause, and taking steps to prevent its recurrence;
(4) having a thorough knowledge of management policies and administrative procedures of the registrant and keeping management informed on a periodic basis of the performance of the registrant's radiation protection program;
(5) assuming control and having the authority to institute corrective radiation control actions, including shut down of operations if necessary, in emergency situations or unsafe conditions;
(6) ensuring that personnel are adequately trained in and complying with this Article, the conditions of the certificate of registration or certified registration, and the operating and safety procedures of the registrant; and
(7) maintaining all records as required by this Article.
(c) For human use radiation equipment installations, the radiation safety officer must be:
(1) a QMP; or
(2) a professional practitioner practicing within the scope of such person's professional practice.
(d) For human use radiation equipment installations requiring a certified registration pursuant to 24 RCNY Health Code § 175.41, the radiation safety officer must be:
(1) a QMP certified by the American Board of Health Physics, the American Board of Radiology or the American Board of Medical Physics in a branch of physics related to the type of use of radiation sources in the installation; or
(2) an authorized user named on the facility's certified registration issued by the Department.
(e) For non-human use radiation equipment installations, the radiation safety officer must be:
(1) a veterinarian for veterinary installations; or
(2) a QMP; or
(3) a person with equivalent training and experience as determined by the Department; or
(4) a researcher or other individual determined by the institution as qualified by training and experience for installations using only x-ray diffraction and fluorescence analysis equipment.
(Added City Record 4/24/2019, eff. 5/24/2019)