BetaNYCLaw Reader
Contents
  1. Home
  2. NYC Rules
  3. Title 1
  4. Chapter 100
  5. Part 7 of 7

1 RCNY Chapter 100 [Administration; Enforcement; Maintenance of Buildings; Licensing; Miscellaneous Provisions], part 7 of 7

§ 105-04 to § 105-08: 4 sections.

§ 105-04. Applications Filed by a Licensed Sign Hanger

Open this section

(a) Scope. This rule establishes when licensed Master Sign Hangers and Special Sign Hangers may file applications for permits to install signs and related structural elements.

(b) References. See Administrative Code (AC) § 28-104.6, item 5, and Administrative Code, Title 28, Article 415.

(c) Licensed Sign Hanger. The term Licensed Sign Hanger shall refer to the holder of a Master Sign Hanger or Special Sign Hanger license.

(d) Conditions for Filing Sign Applications. Pursuant to § 28-104.6, item 5, a Licensed Sign Hanger may file applications for permits to install a sign and any related structural elements, provided he or she complies with all the following:

(1) The sign application must comply with the applicable provisions of the New York City Building Code and Zoning Resolution.

(2) The application must be limited to wall-mounted, accessory signs.

(3) The area of the display face of any sign must not exceed one hundred fifty (150) square feet. The area of the sign includes the entirety of individual letters, groups of letters, symbols, images, or any portion thereof.

(4) The sign, or any portion of it, must not project more than 18 inches beyond the face of a building, regardless of the building's setback.

(5) The entire sign must be mounted below the height of the second story ceiling.

(6) The sign must not exceed three hundred (300) pounds in total weight. The total weight includes all portions of the sign and any related structural elements, including individual letters, groups of letters, symbols, images, associated electrical components, structural supports, hardware, framework, or any portion thereof, even if the sign is erected in stages or portions over time. If structural work beyond a frame or support used to provide rigidity is required, a registered design professional must design all structural plans.

(7) Signs must be mounted by means of mechanical anchors installed in accordance with the table below. Anchors must be fastened 12 inches on center, with a minimum of four anchors used. The anchors must be able to support an allowable stress of five times the weight of the sign and any related structural elements.

Anchors in Concrete and Masonry Walls Anchor Diameter Embedment Depth 1/4" 1" minimum 5/16" 1" minimum 3/8" 1 1/4" minimum 1/2" 1 1/2" minimum 5/8" 2" minimum 3/4" 2" minimum Anchors in Wood Walls Anchor Diameter Embedment Depth 1/4" to 3/4" 2" minimum

(e) Prohibited filings. Notwithstanding subdivision (d) of this section, a Licensed Sign Hanger may not file applications for permits to install any of the following:

(1) Any rooftop mounted sign;

(2) Any sign projecting more than 18" across a street line;

(3) Any marquee;

(4) Any digital sign; or

(5) Any related structural elements other than those referenced in subdivision (d) of this section.

A registered design professional must file the applications listed in subdivision (e).

(Added City Record 3/8/2017, eff. 4/7/2017)

§ 105-05. Adjudications

Open this section

(a) Hearings concerning the following matters under the jurisdiction of the Department shall be held before the Office of Administrative Trials and Hearings and shall be governed by the rules of procedure utilized at that tribunal:

(1) Proceedings pursuant to Administrative Code § 28-104.2.1 and § 28-104.2.1.3.2 against a registered design professional seeking suspension, exclusion, or other limitation on such registered design professional's participation in the Professional Certification Program.

(2) Proceedings pursuant to Administrative Code §§ 28-104.2.1, § 28-114.1 and § 28-115.2 seeking the suspension, revocation, disqualification or other limitation, with or without penalties, of the authority of any licensee or holder of a certificates of competence issued by the Department, approved agency, special inspector, registered design professional or any other person to conduct inspections of work or tests or to participate in any program authorizing either less than full examination of documents based on a registered design professional's professional certification or self-certification of the results of document preparation or review or an inspection.

(3) Proceedings pursuant to Administrative Code § 28-211.1.2 charging a person with having knowingly or negligently made a false statement or having knowingly or negligently falsified or allowed to be falsified any certificate, form, signed statement, application, report or certification of the correction of a violation required under the provisions of the code or of any rule of any agency.

(4) Proceedings pursuant to Administrative Code Articles 212 and 214 seeking an order of closure.

(5) Disciplinary proceedings pursuant to Administrative Code § 28-401.19 seeking suspension or revocation, with or without penalties, against any licensee or holder of a certificates of competence issued by the Department.

(6) Hearings pursuant to Administrative Code Article 419 for the return of seized property, separately or in conjunction with hearings to adjudicate the violation underlying the seizure.

(7) Civil service employee disciplinary matters.

(8) Any other administrative adjudicatory hearing not otherwise committed to the jurisdiction of another agency.

§ 105-06. Petitions for Rulemaking

Open this section

(a) Definitions.

(1) Person. "Person" means a natural person or a business entity, including but not limited to a corporation, trust, estate, partnership, cooperative, association, firm, club or society.

(2) Petition. "Petition" means a written request or application for the Department to adopt a Rule.

(3) Petitioner. "Petitioner" means the person who files a Petition.

(4) Rule. "Rule" has the meaning set forth in § 1041 of the City Administrative Procedure Act.

(b) Procedures for Submitting Petitions.

(1) Any Person may petition the Department to consider the adoption of a Rule. The Petition may be denied if it fails to include the following information:

(i) The Rule to be considered, with proposed language for adoption;

(ii) Petitioner's arguments in support of adoption of the Rule;

(iii) Petitioner's proposal for the time period the Rule should be in effect, if applicable;

(iv) Responses to any questions posed on a form provided by the Department for such Petitions;

(v) The name, address, telephone number, and email address of the Petitioner or his or her authorized representative;

(vi) The signature of Petitioner or his or her representative.

(2) Any change in the name, address or telephone number of the Petitioner or his or her authorized representative must be reported to the Department.

(3) All Petitions should be typewritten, if possible, but handwritten Petitions will be accepted provided they are legible.

(4) Petitions must be submitted via dobrules@buildings.nyc.gov or by mailing the Petition to the Department of Buildings, Regulatory Matters Unit, Office of the General Counsel, 280 Broadway, 7th Fl., New York, NY 10007.

(c) Procedures for Consideration of and Responses to Petitions. If a Petition is submitted in proper form, the Department will deny or approve the Petition within 60 days from the date it was received. The Department will either deny such Petition in a written statement or state in writing the Department's intention to initiate rulemaking by a specified date. The Department is not required to grant the entirety of a Petition and is not bound by the language proposed by Petitioner but may amend or modify such proposed language at the Department's discretion.

(Added City Record 12/1/2021, eff. 12/31/2021)

§ 105-08. Ancillary Dwelling Units Outside the Temporary Residence Program Associated with a Single- or Two-Family Residence

Open this section

(a) Scope. This rule establishes requirements for the occupancy and use of all ancillary dwelling units (“ADU”) not enrolled in the Temporary Residence Program covered in Article 507 of Title 28 of the New York City Administrative Code (“Administrative Code”) and that are associated with a single- or two-family residence.

(b) Definitions. For the purposes of this section, the following terms have the following meanings:

ADU. An “ancillary dwelling unit” as defined in § 12-10 of the New York City Zoning Resolution (“Zoning Resolution”).

Alt-CO. An application for alteration permit pursuant to Article 105 of Title 28 of the Administrative Code leading to a new or amended certificate of occupancy issued pursuant to Article 118 of Title 28 of the Administrative Code.

Building Code. The New York City Building Code.

CO. A certificate of occupancy issued pursuant to Article 118 of Title 28 of the Administrative Code.

TCO. A temporary CO issued pursuant to Article 118 of Title 28 of the Administrative Code.

(c) References. Appendix U of the Building Code, Chapter 10 of the Building Code and the Zoning Resolution.

(d) Eligibility. An ADU must comply with the Zoning Resolution and paragraphs (1) through (4) of this subdivision.

(1) No more than one ADU per single- or two-family residence is permitted on the same zoning lot.

(2) At the time of initial occupancy for an ancillary dwelling unit, the zoning lot on which the ancillary dwelling unit is located must be the primary residence of an owner of such zoning lot, in accordance with subdivision (f) of the definition of ancillary dwelling unit in § 12-10 of the Zoning Resolution. The department may require submission of the same evidence of primary residence as required in 19 RCNY § 46-03.

(3) In accordance with section U202.3 of the Building Code, no ADUs may be permitted in a basement or cellar where the portion of the tax lot containing an ADU constructed in accordance with Appendix U of the Building Code is located within the special flood hazard area, 10-year rainfall flood risk area, or costal flood risk area. These prohibited areas are set out as follows:

(i) Special flood hazard area: Defined in section 202 of the Building Code.

(ii) 10-year rainfall flood risk area: Set out in the map established by the New York City Department of Environmental Protection in accordance with section 24-809 of the Administrative Code and Chapter 66 of Title 15 of the Rules of the City of New York.

(iii) Coastal flood risk area: Set out in the map established by Department of Environmental Protection in accordance with § 24-809 of the Administrative Code and 15 RCNY Chapter 66.

(4) An ADU may be permitted to be constructed in the basement or cellar in conjunction with the erection of a single-family residence, if all of the following conditions are met:

(i) Such ADU is permitted by the Zoning Resolution, and the entire tax lot is outside the prohibited area set forth in this paragraph (3) of this subdivision.

(ii) The basement or cellar ADU is within the same building as the primary dwelling unit, in accordance with § 12-10 of the Zoning Resolution and paragraph (2) of this subdivision.

(iii) Occupancy of such ADU in a basement or cellar, as defined by section 202 of the Building Code, must be in accordance with § 27-2087 of the Housing Maintenance Code, as applicable.

(iv) Both the ADU and the primary dwelling unit must be classified as Group R-3 occupancy and must comply with all applicable requirements of a two-family residence and Group R-3 occupancy in the New York City Construction Codes, New York City Fire Code and Housing Maintenance Code.

(v) Such ADU must be indicated as “ADU Apartment U” in the CO.

(vi) The application and the comment of the CO must indicate that the “Ancillary Dwelling Unit is being constructed in accordance with § 12-10 of the Zoning Resolution and 1 RCNY 105-08(d)(4).

(vii) For ADUs located in the cellar, all of the following requirements apply:

(A) Cellar ADUs must be provided with two independent means of egress in accordance with Chapter 10 of the Building Code.

(B) Cellar ADUs must be provided with an automatic sprinkler system throughout the ADU in accordance with NFPA 13D as modified by Appendix Q of the Building Code. A building that consists of three stories or more and a cellar ADU must be sprinklered in its entirety in accordance with section 903.2.8 of the Building Code.

(C) Any yards, courts or other open spaces required by the Zoning Resolution must be no higher than 6 inches below the windowsill of any required window in any room of such cellar ADU.

(D) Applications for the construction of an ADU in a cellar may not be submitted unless and until § 27-2087 of the Housing Maintenance Code provides for such occupancy in cellars.

Except for sections U202.8, U202.9, U202.10 and U202.11, the provisions of Appendix U of the Building Code do not apply to an ADU constructed pursuant to this paragraph (4).

(e) Application. All ADU applications must be filed under the house number assigned by the Topographical Bureau of the appropriate Borough President’s office.

(1) The ADU types below that share the same CO with the primary dwelling must be filed as an Alt-CO application:

(i) Attic ADUs constructed in accordance with section U201 of the Building Code.

(ii) Basement or cellar ADUs constructed in an existing building in accordance with section U202 of the Building Code.

(iii) All other above grade ADUs, except for attic ADUs, such as vertical enlargements, horizontal enlargements, and subdivisions from the bulk of the existing single-family residence and constructed in accordance with section U201 of the Building Code.

(2) The ADU types below must apply for a new CO and obtain a new Building Information Number (BIN).

(i) Detached ADUs constructed in accordance with section U204 of the Building Code.

(ii) Manufactured homes constructed in accordance with section U205 of the Building Code.

(iii) ADUs abutting the primary dwelling and separated from the primary dwelling with a fire wall in accordance with section U203 of the Building Code. To obtain a new house number, the address verification application to the Borough Topographical Bureau must indicate the location of the fire wall.

(3) ADUs converted from an existing detached garage:

(i) If the detached garage is recorded on the same CO as the primary dwelling, one no-work Alt-CO application must be filed for the primary dwelling and another Alt-CO application must be filed for the ADU.

(ii) If the detached garage is recorded on a CO separate from the primary dwelling or is not recorded on a CO, the ADU must be filed as an Alt-CO application under a different BIN than the primary dwelling. A new BIN may be required for the ADU.

(f) Technical requirements.

(1) ADU entrance identification. Where the eligible basement or cellar residence entrance is not apparent from the street, a permanent directional sign with red letters at minimum of 5 inches tall over white background must be mounted on the primary dwelling, stating in sentence form: “Basement (or Cellar) ADU entrance is located on Exposure [#], as viewed from street-facing side (Exposure 1).” For purposes of this section, building sides shall be numbered as follows: Exposure 1 is the side facing the street on which the building’s official address is assigned; Exposure 2 is the side to the left when standing in the street facing Exposure 1; Exposure 3 is the side opposite Exposure 1; and Exposure 4 is the side to the right when standing in the street facing Exposure 1.

(2) Water sensors and alarms.

(i) Installation. Pursuant to item 1 of section U202.11 of the Building Code, water sensors and alarms must be installed in every habitable space, as defined in section 202 of the Building Code, in an ADU located in a basement or cellar to provide warning to the occupants in the event of a flood and must be installed in accordance with the requirements of this section.

(ii) Water sensor and alarm units. In each habitable room, one water sensor and alarm with alternating current (AC) power of a type acceptable to the department must be installed in addition to one water sensor and alarm with battery power to satisfy the requirements of section U202.11 of the Building Code. One AC power water sensor and alarm that also has battery backup power will be deemed compliant with this requirement.

(iii) Locations. Water sensors and alarms must be installed in every habitable space at the following locations:

(A) Any interior space or area immediately adjacent to flood water ingress points, such as windows, doors, and other wall openings. However, no more than two are required for each habitable room.

(B) On the finished floor, or in accordance with the manufacturer’s instructions.

(iv) Visual notification. The water sensors and alarms must have a visual notification function when requested by the tenant.

(v) Average sound pressure. The water sensor and alarm must provide a minimum sound pressure level of 75 dBA.

(vi) Owner’s responsibility. The owner is responsible to inspect all of the water sensors and alarms and replace the battery as necessary, but at least once a year, prior to a tenant’s occupancy, and after a flood event.

(3) Flood mitigation for ADUs above grade. ADUs that are not backyard ADUs as defined in the Zoning Resolution and are constructed in accordance with section U201, U203 or U204 of the Building Code, may be created within buildings that lawfully existed on or prior to December 5, 2024, provided that such ADUs are elevated as described below:

(i) Where the tax lot is located within the Special Flood Hazard Area defined in section 202 of the Building Code, the lowest floor of the ADU must be elevated to the design flood elevation in accordance with Appendix G of the Building Code. The CO must include all applicable statements in accordance with Appendix G of the Building Code.

(ii) Where the tax lot is located within the costal flood risk area defined in section U202.2 of the Building Code, to be determined as described in paragraph (3) of subdivision (d) of this section, but not located in the Special Flood Hazard Area defined in section 202 of the Building Code, the lowest floor of the ADU must be elevated to a minimum of 3 feet above the highest adjacent grade to such ADU.

(iii) Where the tax lot is located is within the 10-year rainfall flood risk area defined in accordance with section U202.2 of the Building Code, to be determined as described in paragraph (3) of subdivision (d) of this section, but not located in the Special Flood Hazard Area defined in section 202 of the Building Code, the lowest floor of the ADU must be elevated to a minimum of 2 feet above the highest adjacent grade to such ADU.

(Added City Record 9/30/2025, eff. 9/30/2025)