NYC Administrative Code Section BC 1602 Definitions and Notations
1602.1 Definitions.
The following terms are defined in Chapter 2:
ALLOWABLE STRESS DESIGN.
BALCONY, EXTERIOR.
DEAD LOAD.
DECK.
DESIGN STRENGTH.
DIAPHRAGM.
Diaphragm, blocked.
Diaphragm boundary.
Diaphragm chord.
ESSENTIAL FACILITIES.
FABRIC PARTITION.
FACTORED LOAD.
HELIPAD.
ICE-SENSITIVE STRUCTURE.
IMPACT LOAD.
LIMIT STATE.
LIVE LOAD.
LIVE LOAD (ROOF).
LOAD AND RESISTANCE FACTOR DESIGN (LRFD).
LOAD EFFECTS.
LOAD FACTOR.
LOADS.
NOMINAL LOADS.
OTHER STRUCTURES.
PANEL (PART OF A STRUCTURE).
RESISTANCE FACTOR.
RISK CATEGORY.
STRENGTH, NOMINAL.
STRENGTH, REQUIRED.
STRENGTH DESIGN.
SUSCEPTIBLE BAY.
VEHICLE BARRIER.
NOTATIONS.
D = Dead load.
D i = Weight of ice in accordance with Chapter 10 of ASCE 7.
E = Combined effect of horizontal and vertical earthquake induced forces as defined in Section 12.4.2 of ASCE 7.
F = Load due to fluids with well-defined pressures and maximum heights.
F a = Flood load in accordance with Chapter 5 of ASCE 7.
H = Load due to lateral earth pressures, ground water pressure or pressure of bulk materials.
L = Roof live load greater than 20 psf (0.96 kN/m 2 ) and floor live load.
L r = Roof live load of 20 psf (0.96 kN/m 2 ) or less.
R = Rain load.
S = Snow load.
T = Cumulative effects of self-straining load forces and effects.
V asd = Allowable stress design wind speed, miles per hour (mph) (km/hr) where applicable.
V = Basic design wind speeds, miles per hour (mph) (km/hr) determined from Table 1609.3 of this code.
W = Load due to wind pressure.
W i = Wind-on-ice in accordance with Chapter 10 of ASCE 7.