NYC Administrative Code RS 18-6 CONSOLE OR STAGE LIFTS
1. PLATFORM OR CAR CONSTRUCTION.—
(a) Suspension or supporting frames of all console or stage lifts shall be constructed of structural steel, wrought iron shapes, or of any noncombustible material whose strength shall satisfy the loads and stresses requirements of the building code.
(b) The minimum factor of safety of all materials used in car platforms and slings shall conform to the requirements of reference standard RS 18–1.
2. CABLES.—Hoisting cables shall have a safety factor conforming to the requirements of reference standard RS 18–1.
3. HOISTING.—Platforms may be operated by cables, plunger, or screw type equipment, and shall maintain a minimum factor of safety of all materials used in operating the platform conforming to the requirements of reference standard RS 18–1.
4. CONTROL.—
(a) Up and down control shall be provided near the lift in a location where it can be easily operated and where the operator will have an unobstructed view of the lift.
(b) An emergency stop switch shall be provided within easy reach of the operator, and when operated, it shall cut off power from the hoisting equipment.
5. ENTRANCE.—When the entrance to such console or stage lift is at one or more points below the stage level, such entrance or entrances shall be provided with a gate or door with mechanical lock and electric contact, or the platform shall be provided with an apron made of sheet steel or plywood covered with 26 gauge sheet steel, at the entrance side or sides extending from the platform to below the lowest landing with the platform at its maximum raised position. If the platform rises above the stage level, all unguarded sides shall be provided with aprons extending from the platform to below the stage level.