NYC Administrative Code SECTION 3 – DESIGN
3.1 The provisions of the building code for stresses shall apply.
3.2 The hangers shall be spaced at 4'–6" or less on centers. Each hanger shall be capable of carrying all loads suspended therefrom plus an additional 200 pounds located at midspan. The midspan deflection as attested in accordance with the test method described in Section 6 of this standard or as calculated shall not exceed 1/360 of the span. The connections of the carrying channel to the hangers shall be adequate for the load supported by the carrying channel plus 200 pounds.
3.4 The main runner or nailing bar shall be capable of carrying all loads suspended therefrom. The midspan deflection as tested in accordance with the test method described in Section 6 of this standard or as calculated shall not exceed 1/360 of the span. Each connection of the main runner or nailing bar to the carrying channels shall be adequate for the load supported by the main runner plus two (200) pounds.
3.5 Cross runners shall be capable of carrying all loads suspended therefrom. The midspan deflection as tested in accordance with the test method described in Section 6 of this standard or as calculated shall not exceed 1/360 of the span.
3.6 Splines shall not be considered as providing nor shall be used for providing, structural support for the ceiling material.
3.7 All connection devices other than bolts shall be approved by the Board of Standards and Appeals. However they may be accepted under the code test method when test results indicating a factor of safety of four are filed in accordance with the provisions of section 27-131 of the building code.