6.1 INTRODUCTION.—The test method outlined provides the means by which data can be secured for characterizing the structural performance of individual suspension systems. The method consists of placing structural members as beams on simple supports, and subjecting them to simulated uniformly distributed loads over their length. The loading is incrementally imposed and the performance of the structural member is obtained from observing the resulting beam deflections.
6.2 SCOPE.—The test method shall be used for evaluating the load deflection performance of structural members of all acoustical tile and lay-in panel suspension systems. A simple experimental facility is described which can be adjusted as required to permit testing of structural members of different sizes, having various section configurations, and on different appropriate span lengths.
Some suspension systems incorporate a locking assembly system which enhances performance by providing some continuity or load transfer capability between adjacent sections of the ceiling grid. This test method does not provide the means for making a complete evaluation of continuous beam systems, nor for assessing the continuity contribution to overall system performance. However, the method can be used for evaluating primary structural members in conjunction with secondary members which interlock, as well as with those of noninterlocking type.
6.3 LOADING FACILITY.—The loading of structural members shall be performed in a manner which closely simulates their use in suspension systems. Span distances, spacing between secondary supports, etc., shall all be typical of ceiling grid designs in which the structural member is used.
6.3.1 Support frame—A rectangular support frame having the essential features of the unit described below shall be provided.
6.3.1.1 The frame (Fig. 4) shall have the capability for length adjustment to permit testing of structural members on clear spans for a maximum of 8 ft. to a minimum of 3 ft. It shall have the capability for overall width adjustment with a maximum length of 4 ft. and a maximum length of 1 ft.
6.3.1.2 The support frame shall have sufficient stiffness so that no significant deflection occurs within the frame during load tests of suspension system structural members.
6.3.1.3 The support frame may either be ceiling mounted or floor supported.
6.3.2 Test loading—The main runner weight shall not be used for evaluating load-deflection performance. One-half the weight of the cross runners shall be included as part of the test load.
6.3.2.1 Individual test weights appropriate for evaluating the structural member shall be provided. Loads weighing up to 1 lb. shall be provided so that their actual weight is within 0.01 lb. of their marked weight. Weights over 1 lb. shall be within 1 percent of their marked weight. Loading weights of the sizes required can be conveniently provided by weighing lead shot into cloth bags and tying them closed.
6.3.2.2 A sufficient number of weights of suitable mass shall be provided to permit evaluation of the structural member through its elastic range by loading in approximately ten equal load increments. When elastic performance of the member under test is exceeded, loading shall continue using a suitably reduced load increment until significant sectioning yielding has been produced.
6.3.2.3 A complete load increment shall be applied simulating a uniformly distributed load imposed over the entire section length before measuring the deflection of the structural member.
6.3.2.4 Provision shall be made for imposing test loads on the structural member in a symmetrical manner.
6.3.3 Deflection measurements—The deflection of structural members shall be observed after application of each full load increment during the entire test.
6.3.3.1 The deflection of structural members being tested shall be measured with dial indicators capable of direct reading to 0.001 in.
6.3.3.2 Dial indicators shall be mounted from a separate gauge from (Fig. 4) having three points of support. The gauge frame shall be supported from the test loading frame and be properly positioned to locate the dial stems vertically over the structural member being tested.
6.3.3.3 The dial indicators used shall have sufficient travel capability to permit the deflection performance of the structural members to be observed during the entire test without requiring resetting.
6.4 STRUCTURAL MEMBERS.—The manufacturer, installer, or architect or engineer, shall determine the load-deflection performance.
6.4.1 The structural members tested shall be identical to the sections used in the final system design. All cutouts, slots, etc., as exist in the system component shall be included in the sections evaluated.
6.4.2 Allowable mill variations of sheet stock thickness have a significant effect on section stiffness and load carrying ability. Consequently, load-deflection studies of structural members shall utilize sections fabricated in accordance with system manufacturers' published metal thicknesses and dimensions.
6.5 PROCEDURE.—The procedures used for evaluating performance of suspension system structural members shall utilize the general principle of following actual field installation practice wherever possible. As an example of the general procedure to be followed, the setup and testing of a primary structural member is described below.
6.5.1 Experimental setup—In preparation for testing, the length and width of the support frame shall be adjusted to the typical grid dimensions that are established as appropriate to the evaluation of the structural member. The primary structural member shall be installed along the longitudinal centerline of the frame and supported at its ends as an essentially simply supported beam (Fig. 4). Where secondary members are used, they shall be installed normal to the direction of the primary structural member and at the midpoint and quarterpoint locations along the test span length. One end of such secondary members shall be supported from the side of the test frame and at the other from the flange of the primary structural member (Fig.4). Clearances between the ends of the secondary structural member in the test setup shall be typical of that which exists in the actual ceiling grid.
Where interlocking secondary structural members are used, they shall be assembled into the central primary structural member being tested in customary fashion and using conventional center distance spacing. The other end of the secondary member shall be simply supported from the perimeter support frame. No interlocking of the secondary member and the perimeter support frame shall be permitted.
6.5.2 Section loading—With the structural member to be evaluated installed in the support frame, the gauge frame shall be positioned to mount the vertical displacement deflection dials directly over the test section at the midspan and quarterspan locations at which time dials are positioned to read zero (Fig. 4). The test loads shall be applied to the structural member in a manner representative of that which exists in service. For test purposes simple wire hangers shall be provided to suitably introduce the load to the section. Extending from such hangers, attachment wires, cords or lightweight chains shall be provided to permit the preweighed incremental test weights to be added as required. The weight of hangers, wires, pans, etc. shall be incorporated as part of the test load.
The test weights, simulating the weight of ceiling tile of panel, shall be applied to the structural member starting 6 in. from the end supports, and at 1 ft. intervals thereafter, always proceeding from the ends toward the center of the span in applying load. After the first uniformly distributed load increment has been applied, the midspan and quarter-span deflection of the structural member shall be measured and recorded. Loading of the structural member shall be continued in the same manner, applying successive increments of uniformly distributed load and observing deflections after each increment. Loading shall be continued until it is apparent that the test section has yielded.
The load deflection performance of secondary structural members of acoustical tile and lay-in panel ceiling systems shall be similarly determined. The units shall be set up and tested in a manner appropriate to their use in actual grid systems.
6.6 EXPERIMENTAL DATA.—A test log shall be prepared to record all pertinent data regarding the structural member being evaluated and the principal accessory items used. Such information as the following shall be provided:
Manufacturer's name.
Suspension system identification.
Test section identification.
Description of section: measure overall height and thickness of basic stock, type of material, section weight, etc.
Test span length.
Spacing of lateral supports.
Identification of accessory items and how used.
Sketch of experimental setup, giving dimensions of grid, dial gauge locations, load spacing, etc.
Record of the incrementally applied uniformly distributed loads and the resultant midspan and quarter-span deflection and the resultant midspan and quarter-span deflections measurements for each loading.
6.7 SECTION PERFORMANCE.—The performance of structural members of suspension systems shall be represented by individual load-deflection plots obtained from tests performed at each different span length used in service.
6.7.2 The results of replicate tests of three individual sections each tested on the same span length, shall be plotted and averaged to obtain a characteristic load-deflection curve for the structural member.
6.7.3 The average load-deflection curve shall be used to establish the maximum uniformly distributed load which the structural member can successfully sustain prior to reaching the deflection limit of 3/360th of the span length in inches. (Fig. 5)
6.7.4 The load-deflection curve shall be used to establish the maximum loading intensity beyond which the structural member begins to yield.
6.8 SUSPENSION SYSTEM PERFORMANCE.—Published performance data for individual suspension systems shall be developed by the manufacturer upon the basis of results obtained from load-deflection tests of its principal structural members. Where a ceiling design incorporates a number of components, each of which experiences some deflection as used in the system, the additive nature of these displacements shall be recognized in setting an allowable system deflection criteria.