NYC Administrative Code RS 5-1B

GA–600 1988—Fire Resistance Design Manual, Twelfth Edition, as Modified.

MODIFICATIONS.—The provisions of GA–600–1988 shall be subject to the following modifications:

1. Revise the heading on the top of page five in the section on USE OF MANUAL to read as follows:

LIMITING HEIGHTS

(a) NONLOAD-BEARING PARTITIONS

2. Insert the following after the paragraphs on (a) NONLOAD-BEARING PARTITIONS and before the heading PERFORMANCE OF PLASTER:

(b) LOAD BEARING PARTITIONS

Lateral bracing and height limitations shall be designed in accordance with the applicable reference standard independent of the sheathing.

3. In the section on GENERAL EXPLANATORY NOTES under the heading USE OF MANUAL, add the following paragraph:

15. All concrete slabs shall be structurally adequate. Such slabs shall have a minimum compressive strength of 3000 psi., with the reinforcement and thickness at least that as shown in the test.

4. In the assemblies listed under the heading WALLS AND INTERIOR PARTITIONS, NONCOMBUSTIBLE, the following requirements are added to the Detailed Description for (LOAD BEARING) assemblies:

WP 1204, WP 1206, WP 1635, WP 1714 and WP 1716 under the GA and Company Codes:

Steel Studs.—Steel studs shall be a minimum of 3 1/2 inches wide and a minimum galvanized steel or 18GA (.0478) or heavier, primed steel, cold-formed, and shall comply with Reference Standard RS 10–6 (Specification for the Design of Cold-Formed Steel Structural members by AISI, as modified). Lateral supporting members and all details enhancing the structural integrity of the wall assembly shall be as specified by the steel stud designer, and shall meet the applicable requirements of the Code.

5. In the assemblies listed under METAL CLAD EXTERIOR WALLS, assemblies WP 9010, WP 9060, WP 9225, WP 9325, under the GA File No. heading, are deleted in its entirety.

6. Insert the following heading after the paragraph on USE OF PLENUM SPACE in the section on FLOOR-CEILINGS:

SUSPENSION SYSTEMS

Suspended ceilings contained herein shall comply with the requirements of Reference Standard RS 5–16.

7. In the assemblies listed under FLOOR-CEILING ASSEMBLIES, NON-COMBUSTIBLE, assembly FC 4120, under the GA File No. heading, is deleted in its entirety.

8. In the assemblies listed under FLOOR-CEILING ASSEMBLIES, WOOD-FRAMED, assembly FC 5105, under the GA File No. heading, is deleted in their entirety.

9. In the assemblies listed under BEAMS, GIRDERS, AND TRUSSES, assemblies BM 3310, BM 4410 and BM 4420, under the GA File No. heading, are deleted in their entirety.

10. The following assemblies which were listed in the Gypsum Association Fire Resistance Manual, Eleventh Edition, but do not appear in the Twelfth Edition, may continue to be used:

WP 1016 WP 1725 WP 1260 WP 7083 WP 1300 WP 7086 FC 5010 FC 5430 FC 5108