NYC Administrative Code RS 14-16

Reduced Minimum Clearances for Equipment, using Specified Forms of Protection a

Specified Form of Protection Reduced Clearances (in.) Where the Required Clearance with no Protection is: 36 in. 18 in. 12 in. 6 in. Above Side and Rear Above Side and Rear Above Side and Rear Above Side and Rear (a) 1/4 in. asbestos millboard spaced out 1 in. b 30 18 15 9 9 6 3 2 (b) 28 gauge sheet metal on 1/4 in. asbestos millboard 24 18 12 9 9 6 3 2 (c) 28 gauge sheet metal spaced out 1 in. b 18 12 9 6 6 4 2 2 (d) 28 gauge sheet metal on 1/8 in. asbestos millboard spaced out 1 in. b 18 12 9 6 6 4 2 2 (e) 1 1/2 in. asbestos cement covering on heating equipment 18 12 9 6 6 4 2 1 (f) 1/4 in. asbestos millboard on 1 in. mineral fiber bats reinforced with wire mesh or equivalent 18 12 6 6 4 4 2 2 (g) 22 gauge sheet metal on 1 in. mineral fiber bats reinforced with wire or equivalent 18 12 4 3 2 2 2 2 (h) 1/4 in. asbestos cement board or 1/4 in. asbestos millboard 36 36 18 18 12 12 4 4 (i) 1/5 in. cellular asbestos 36 36 18 18 12 12 3 3

Notes—

a Except for the protection described in (e), all clearances shall be measured from the outer surface of the equipment to the combustible material disregarding any intervening protection applied to the combustible material.

b Spacers shall be of non combustible material.

Applicable to the combustible material, unless otherwise specified, and covering all surfaces within the distance specified as the required clearance with no protection.