NYC Administrative Code SECTION 3 – MATERIALS
3.1 QUALITY.—Masonry materials shall conform to the standards and requirements set forth herein. Where no standards are established, the quality of materials shall be based on generally accepted good practice.
3.2. MASONRY UNITS.—Except as noted in sections 3.2.1 to 3.2.3, the quality of all masonry units used in building shall conform to the standard and grade shown in table RS 10–1.1. Manufacturer's certification as to the suitability of the material for the proposed use shall be submitted for all masonry units used in structural applications.
3.2.1 Ceramic veneer.—All ceramic veneer shall have a strong homogeneous body conforming to the following physical requirements:
(a) The average compressive strength of at least five 1 in. square specimens shall be not less than 5,000 psi with no individual specimen testing less than 4,500 psi. Compression tests shall be made on five specimens, 1 in. by 1 in. face size and the full thickness of the ceramic veneer. Loads shall be applied to the test specimens in a direction parallel to the exposed face. Specimens shall be capped and tested in accordance with reference standard RS 10–30.
TABLE RS 10–1–1 Material Standards
Units Reference Standard Severe Exposure Minimum Grade Moderate Exposure No Exposure Brick— • Clay or shale RS 10–31 SW MW NW • Sandlime RS 10–32 SW MW NW • Concrete RS 10–33 U Pc G Structural Clay Tile— • Loadbearing RS 10–34 LBX LBX LB • Non-Loadbearing RS 10–35 not permitted not permitted NB Concrete Masonry Units— • Solid loadbearing RS 10–36 U Pc G • Hollow loadbearing RS 10–37 U Pc G • Hollow non-loadbearing RS 10–38 not permitted permitted permitted Gypsum a— • Partition tile or block RS 10–39 not permitted not permitted permitted a • Cast Stone RS 10–43 permitted permitted permitted Ceramic Glazed Clay Masonry Units b— • Solid Units RS 10–40 permitted permitted permitted • Hollow Units RS 10–40 permitted permitted permitted Prefaced Concrete Masonry Units— RS 10–33 permitted permitted permitted RS 10–36 permitted permitted permitted RS 10–37 permitted permitted permitted
Notes—
a Gypsum partition tile or block shall not be used in bearing walls, or where subject to continuous dampness. Gypsum partition tile or block shall not be used for partitions to receive Portland cement plaster, ceramic tile, marble or structural glass wainscots unless self-furring metal lath is placed over the gypsum tile.
b Requirements for finish do not apply.
c Grade P may be used for "severe exposure" if protective coatings to prevent water penetration are applied on exterior face.
(b) The average absorption of not less than five specimens by 5 hr. boiling shall not exceed 16 per cent with no individual specimen exceeding 18 per cent. Absorption tests shall be made on five specimens, 6 in. by 6 in. in face size and the full thickness of the ceramic veneer. Absorption tests shall be made in accordance with reference standard RS 10–30.
3.2.2. Glass block.—Block may be solid or hollow; mortar bearing surfaces of the blocks shall be provided with a surface or a coating material to afford adhesion between mortar and block.
3.2.3. Natural stone.—Stone used in masonry shall be sound, free from friable inclusions and have characteristics of strength, durability and resistance to impact and abrasion commensurate with the proposed use.
3.3. METAL ANCHORS AND TIES.—Where corrosion-resistant anchors or ties are called for, they shall be copper coated or zinc coated, or of metal having corrosion-resistant qualities equivalent to zinc-coated mild steel.
(a) Zinc coatings on iron or steel shall conform to reference standard RS 10–23, class B–1, B–2, or B–3.
(b) Zinc coatings on wire shall conform to reference standard RS 10–41, class 1.
(c) Copper coated wire shall conform to reference standard RS 10–42, grade 30 HS.
3.3.1. Prefabricated joint reinforcement.—Prefabricated wire reinforcement for embedment in horizontal mortar joints shall consist of two or more longitudinal wires welded to cross wires. The distance between welded contacts of cross wires with each longitudinal wire shall not exceed 6 in. and 16 in. for smooth and deformed longitudinal wires, respectively. Longitudinal wires and cross wires shall be not less than no. 9 steel wire gage where used in 3/8 in. or thicker mortar joints and not less than no. 12 steel wire gage where used in thinner mortar joints. Cross wires of joint reinforcement that are used to bond the facing and backing of masonry, including cavity walls, shall be corrosion resistant and not less than no. 9 gage. The out-to-out spacing of longitudinal wires shall be such that the wires will be thoroughly embedded in the mortar joints as required in section 10.12.
3.3.2. Unit ties, anchors, or steel bar reinforcement.—Unit metal ties, anchors, or steel bar reinforcements for embedment in horizontal mortar joints shall conform to the applicable requirements of sections 7, 9, 10, and 11 or shall be equivalent in strength and stiffness to the size specified. Any such materials shall have a minimum 30,000 psi. yield strength.
3.4. MASONRY MORTAR AND GROUT.—Mortar, except gypsum, shall conform to reference standard RS 10–46. Grout shall conform to the applicable requirements of reference standard RS 10–47. Gypsum mortar shall be composed of one part gypsum, meeting the requirements of reference standard RS 10–48, to not more than three parts sand by weight. Water shall be clean and potable. Type H mortar shall be subject to controlled inspection and shall have a compressive strength of at least 6,000 psi when tested after 28 days at a cure of 75° F and 50% Relative Humidity, in accordance to ASTM C–109 and shall consist of:
1 bag (94 lbs.) Type I or III portland cement
50 lbs. ground limestone
3 1/4 cu. ft. mortar sand conforming to ASTM C 144
4 gallons polyvinylidene chloride latex having a solids content of at least 46%.
Prior to commencement of construction the supplier of the mortar shall submit an affidavit certifying that all the required ingredients specified have been supplied and included in the mix.
3.4.1. Types of mortar permitted.—Unit masonry shall be laid in mortar of the type specified in table RS 10–1–2.