NYC Administrative Code RS 9-6 EARTHQUAKE LOADS
This section has 2 pictures (figures, equations, or tables drawn as images) that BetaNYC's copy does not show. Read RS 9-6 at American Legal Publishing.
UBC SECTION 2312–1990—Earthquake Regulations with Accumulative Supplement.
MODIFICATIONS—The provisions of UBC Section 2312 shall be subject to the following modifications. The subdivisions, paragraphs, subparagraphs and items are from this section.
Subdivision (a) General.
Paragraph 1. Minimum seismic design.
Delete this paragraph and substitute the following:
The following types of construction shall, at a minimum, be designed and constructed to resist the effects of seismic ground motions as provided in this section:
• new structures on new foundations;
• new structures on existing foundations; and
• enlargements in and of themselves on new foundations. Buildings classified in New York City occupancy group J-3 and not more than three stories in height need not conform to the provisions of this section.
The Commissioner may require that the following types of construction be designed and constructed to incorporate safety measures as necessary to provide safety against the effects of seismic ground motions at least equivalent to that provided in a structure to which the provisions of this section are applicable:
• new buildings classified in occupancy group J-3 and which are three stories or less in height; and
• enlargements in and of themselves where the costs of such enlargement exceeds sixty percent of the value of the building.
Pursuant to section 27-191 of the code the Commissioner shall have the authority to reject an application for a building permit which fails to comply with the requirements of this section.
Subdivision (b) Definitions.
Delete the definitions of the following terms and substitute the following new definitions:
"ECCENTRIC BRACED FRAME (EBF) is a steel-braced frame designed in conformance with reference standard RS 10–5C.
ESSENTIAL FACILITIES are those structures which are necessary for emergency operations subsequent to a natural disaster.
STORY DRIFT is the displacement of one level relative to the level above or below, including translational and torsional deflections."
Add the following definition before "SHEAR WALL":
"REINFORCED MASONRY SHEAR WALL is that form of masonry wall construction in which reinforcement acting in conjunction with masonry is used to resist lateral forces parallel to the wall and which is designed using reinforcement in conformance with Chapter 7 of reference standard RS 10–2."
Delete the definitions of the five frames under the SPACE FRAME paragraph and substitute the following stand-alone definitions:
"INTERMEDIATE MOMENT-RESISTING FRAME (IMRF) is a concrete frame designed in accordance with the requirements of Chapters 1 through 20 and Sections 21.1, 21.2 and 21.9 of reference standard RS 10–3.
MOMENT-RESISTING FRAME is a frame in which members and joints are capable of resisting forces primarily by flexure.
ORDINARY MOMENT-RESISTING FRAME (OMRF) is a moment-resisting frame conforming to the requirements of Chapters 1 through 20 of reference standard RS 10–3 or reference standards RS 10–5A and RS 10–5C but not meeting the special detailing requirements for ductile behavior.
SPECIAL MOMENT-RESISTING FRAME (SMRF) is a moment-resisting frame conforming to reference standards RS 10–3 or RS 10–5A and RS 10–5C and specially detailed to provide ductile behavior by complying with the requirements of Chapters 1 through 20 and Sections 21.1 through 21.8 of reference standard RS 10–3 or reference standards RS 10–5A and RS 10–5C.
VERTICAL LOAD-CARRYING FRAME is a frame designed to carry all vertical gravity loads."
Subdivision (d) Criteria Selection.
Paragraph 1. Basis for design.
Delete the word "zoning" in the first sentence and delete the last sentence.
Paragraph 2. Seismic Zones.
Delete the title and paragraph and substitute the following:
"2. Seismic Zone. The seismic zone factor, Z, for buildings, structures and portions thereof in New York City shall be 0.15. The seismic zone factor is the effective zero period acceleration for S1 type rock."
Paragraph 3. Site geology and soil characteristics.
Delete the title and the paragraph and substitute the following:
"3. Site geology, soil characteristics and foundations.
A. General.
Soil profile type and site coefficient, S, shall be established in accordance with Table No. 23-J.
B. Liquefaction.
(i) Soils of classes 7–65, 8–65, 10–65 and non-cohesive class 11–65 below the ground water table and less than fifty feet below the ground surface shall be considered to have potential for liquefaction.
(ii) The potential for liquefaction of level ground shall be determined on the basis of Standard Penetration Resistance (N) in accordance with Figure No. 4;
Category A: Soil shall be considered liquefiable.
Category B: Liquefaction is possible.
Soil shall be considered liquefiable for structures of Occupancy Categories I, II and III of Table No. 23-K.
Category C: Liquefaction is unlikely and need not be considered in design.
At any site the highest category of liquefaction potential shall apply to the most critical strata or substrata.
(iii) Liquefiable soils shall be considered to have no passive (lateral) resistance or bearing capacity value during an earthquake. An analysis shall be submitted by an engineer which demonstrates, subject to the approval of the Commissioner, that the proposed construction is safe against liquefaction effects on the soil.
(iv) Where liquefiable soils are present in sloped ground or over sloped nonliquefiable substrata and where lateral displacement is possible, a stability analysis shall be submitted by an engineer which demonstrates, subject to the approval of the Commissioner, that the proposed construction is safe against failure of the soil.
C. Foundation Plates and Sills.
Foundation plates or sills shall be bolted to the foundation or foundation wall with not less than one-half inch nominal diameter steel bolts embedded at least seven inches into the concrete or masonry and spaced not more than six feet apart. There shall be a minimum of two bolts per piece with one bolt located within twelve inches of each end of each piece. A properly sized nut and washer shall be tightened on each bolt to the plate.
D. Foundation Interconnection of Pile Caps and Caissons.
Individual pile caps and caissons of every structure subjected to seismic forces shall be interconnected by ties. Such ties shall be capable of resisting, in tension or compression, a minimum horizontal force equal to the product of ZI/4 and the larger column vertical load at the end of each tie.
Exception: Other approved effective methods of foundation interconnection may be used where it can be demonstrated by an analysis that equivalent restraint and relative displacement can be provided."
Paragraph 5, subparagraph C, Irregular structures.
Delete the entire last sentence in item (i).
Paragraph 6, subparagraph E, Dual system.
Delete items (ii) and (iii) and substitute the following:
"(ii) Resistance to lateral load is provided by shear walls or braced frames and a moment-resisting frame (SMRF, IMRF or OMRF). The moment-resisting frames shall be designed to independently resist at least 25 percent of the design base shear. The shear walls or braced frames shall be designed to resist at least 75 percent of the cumulative story shear at every level. Overturning effects may be distributed in accordance with item (iii) below.
(iii) The two systems shall be designed to resist the total design base shear in proportion to their relative rigidities considering the interaction of the dual system at all levels."
Paragraph 7. Height limits.
Delete this paragraph.
Paragraph 8. Selection of lateral force procedure.
Delete paragraph 8 and substitute the following:
"8. Selection of lateral force procedure. All structures shall be designed using either the static lateral force procedure of Section 2312(e) or using the dynamic lateral force procedure of Section 2312(f). In addition, the dynamic lateral force procedure shall be considered, but is not required, for the design of the following:
A. Structures over 400 feet in height.
B. Irregular structures.
C. Structures located on Soil Profile Type S4 which have a period greater than 1 second. The analysis should include the effects of soils at the site and should conform to Section 2312(f)2."
Paragraph 9, subparagraph C, Irregular features.
Delete this subparagraph and substitute the following:
"C. Irregular features. Only structures having either vertical irregularities Type D or E as defined in Table No. 23-M or horizontal irregularities Type D or E as defined in Table No. 23-N shall be designed to meet the additional requirements of those sections referenced in the tables."
Paragraph 10. Alternate procedures.
Add at the end of the paragraph the words "when such procedures are consistent with this standard and subject to the approval of the Commissioner".
Subdivision (e) Minimum Design Lateral Forces and Related Effects.
Paragraph 1. General, subparagraph A.
Add the words "parking structures" before the word "storage" in the first sentence.
Paragraph 1. General, subparagraph C.
Delete this subparagraph.
Paragraph 2, subparagraph A, Design base shear.
Change the value for the minimum ratio of C/Rw shown at the end of this subparagraph to "0.050".
Paragraph 2, subparagraph B, Structure period.
Delete the values in item (i) for Ct and substitute the following:
"Ct = 0.035 for concrete and steel moment-resisting frames.
Ct = 0.030 for eccentric braced frames.
Ct = 0.030 for dual systems where the building height exceeds 400 feet or 0.020 for heights less than 160 feet and varies linearly from 0.020 to 0.030 for building heights from 160 to 400 feet.
Ct = 0.020 for all other structures."
Delete the sentence immediately after "Ct = 0.020 for all other structures" and substitute the following:
"Alternately, the value of T for structures with concrete or masonry shear walls may be taken as 0.1 (hn)3/4 ÖAc."
Paragraph 3, subparagraph C, Combinations along different axes.
Delete this subparagraph.
Paragraph 6. Horizontal torsional moments.
Delete the fourth paragraph starting with the words "Where torsional irregularity exists" and ending with the words "considered for design."
Paragraph 7, Overturning, subparagraph B.
Delete the words "Seismic Zones 3 and 4" at the beginning of this subparagraph.
Delete item (iii) and substitute the following:
"(iii) Such columns shall meet the detailing or member limitations of reference standard RS 10–3 for concrete and reference standard RS 10–5C for steel structures."
Paragraph 7, subparagraph C.
Delete this subparagraph and substitute the following:
"C. For regular buildings, the force Ft may be omitted when determining the overturning moment to be resisted at the foundation-soil interface."
Paragraph 8. Story drift limitation.
Change the value for the minimum ratio of C/Rw shown at the end of this paragraph to "0.050".
Paragraph 9. P-delta effects.
Delete the last sentence of this paragraph.
Paragraph 10. Vertical component of seismic forces.
Delete this paragraph in its entirety and substitute the following:
"10. Vertical component of seismic forces. Horizontal cantilever components shall be designed for a net upward force of 0.05 Wp."
Subdivision (f) Dynamic lateral force procedure.
Paragraph 2. Ground motion.
Add the following at the end of subparagraph A:
"For soil type S4 profile, see B below."
Add the following at the end of subparagraph B:
"The design of all structures located on a soil type S4 profile shall be based on properly substantiated site-specific spectra."
Paragraph 5, subparagraph C, Scaling of results.
Add after the word "procedures" in the first sentence, the words "including the appropriate Importance Factor, I,".
Delete item (i) and substitute the following:
"(i) The base shear shall be increased to the following percentage of the value determined from the procedures of Section 2312(e), including consideration of the minimum value of C/Rw, except that the coefficient C, for a period T greater than 3 seconds, may be calculated as 1.80 S/T:
(a) 100 percent for irregular buildings; or
(b) 90 percent for regular buildings, except that the base shear shall not be less than 80 percent of that determined from Section 2312(e) using the period, T, calculated from Method A."
Paragraph 5, subparagraph D, Directional effects.
Delete the words "and prestressed elements" in the second sentence and delete the word "Alternately" at the start of the third sentence.
Paragraph 5, subparagraph F, Dual systems.
Delete this subparagraph and substitute the following:
"F. Dual Systems. Where the lateral forces are resisted by a dual system, as defined in Section 2312(d)6E above, the combined system shall be capable of resisting the base shear determined in accordance with this section. The moment-resisting frame, shear walls and braced frames shall conform to Section 2312(d)6E. The moment-resisting frame may be analyzed using either the procedures of Section 2312(e)4 or those of Section 2312(f)5."
Paragraph 6. Time history analysis.
Add the following words at the end of the sentence: "and the results shall be scaled in accordance with Section 2312(f) 5C".
Subdivision (h) Detailed Systems Design Requirements.
Paragraph 1. General.
Delete the words "Chapters 24 through 28" in the fourth sentence of the first paragraph and insert the words "reference standard RS 10".
Delete the words "in Seismic Zones 2, 3 and 4" in the second and fourth paragraphs.
Paragraph 2, subparagraph A, General.
Delete the words "Chapters 24 through 27" at the end of this subparagraph and insert the words "reference standard RS 10".
Paragraph 2, subparagraph C, Connections.
Delete this subparagraph.
Paragraph 2, subparagraph D, Deformation compatibility.
Delete the words "to the reinforcing steel" from the last sentence.
Paragraph 2, subparagraph G, Concrete frames.
Delete this subparagraph and substitute the following:
"G. Concrete frames. Concrete frames required by design to be part of the lateral force resisting system shall, at a minimum, be intermediate moment-resisting frames, except as noted in Table 23–0."
Paragraph 2, subparagraph H, Anchorage of concrete or masonry walls.
Delete the words "Section 2310" in the fifth line and insert the words "reference standards RS 9–6, 10–1B and 10–2".
Paragraph 2, subparagraph I, Diaphragms.
Delete items (iv), (v) and (vi).
Paragraph 2, subparagraph J, Framing below the base.
Delete the words "Chapters 26 and 27" in the third line and insert the words "reference standards RS 10–3 and RS 10–5C".
Paragraph 2, subparagraph K, Building separations.
Delete this subparagraph and substitute the following:
"K. Building Separations. All structures shall be separated from adjoining structures. Separation due to seismic forces shall allow for 1 inch displacement for each 50 feet of total building height. Smaller separation may be permitted when the effects of pounding can be accommodated without collapse of the building."
Subdivision (i) Nonbuilding Structures.
Paragraph 4. Other nonbuilding structures.
Delete in the first sentence of item (iii) the word "national" and insert the word "reference", and delete the words "seismic zones and" in the paragraph following item (iii).
Subdivision (j) Earthquake-recording Instrumentations.
Delete this subdivision.
Table No. 23-I, Seismic Zone Factor Z.
Delete this table and substitute the following new table:
Table No. 23-I Seismic Zone Factor Z
ZONE NEW YORK CITY Z 0.15
Table No. 23-J, Site Coefficients.
Delete this table and notes and substitute the following new table and notes:
Table No. 23-J Site Coefficients
Type Descriptions Factor S0 A profile of Rock materials of class 1–65 to 3–65 0.67 S1 A soil profile with either: (a) Soft Rock (4–65) or Hardpan (5–65) or similar material characterized by shear-wave velocity greater than 2,500 feet per second, or (b) Medium Compact to Compact Sands (7–65) and Gravels (6–65) or Hard Clays (9–65), where the soil depth is less than 100 feet. 1.0 S2 A soil profile with Medium Compact to Compact Sands (7–65) and Gravels (6–65) or Hard Clays (9–65), where the soil depth exceeds 100 feet. 1.2 S3 A total depth of overburden of 75 feet or more and containing more than 20 feet of Soft to Medium Clays (9–65) or Loose Sands (7–65, 8–65) and Silts (10–65), but not more than 40 feet of Soft Clay or Loose Sands and Silts. 1.5 S4 A soil profile containing more than 40 feet of Soft Clays (9–65) or Loose Sands (7–65, 8–65), Silts (10–65) or Uncontrolled Fills (11–65), where the shear-wave velocity is less than 500 feet per second. 2.5
Notes:
1. The site S Type and corresponding S Factor shall be established from properly substantiated geotechnical data with the classes of materials being defined in accordance with Section 27-675 (C26–1103.1) of the administrative code of the City of New York.
2. The soil profile considered in determining the S Type shall be the soil on which the structure foundations bear or in which pile caps are embedded and all underlying soil materials.
3. Soil density/consistency referred to in the table should be based on standard penetration test blow counts (N-values) and taken as: (a) for sands, loose—where N is less than 10 blows per foot, medium compact—where N is between 10 and 30, and compact—where N is greater than 30 blows per foot; and (b) for clays, soft—where N is less than 4 blows per foot, medium—where N is between 4 and 8, stiff to very stiff—where N is between 8 and 30, and hard—where N is greater than 30 blows per foot.
4. When determining the type of soil profile for profile descriptions that fall somewhere in between those provided in the above table, the S Type with the larger S factor shall be used.
5. For Loose Sands, Silts or Uncontrolled Fills below the ground water table, the potential for liquefaction shall be evaluated by the provisions of Section 2312(d)3.
Table No. 23-K, Occupancy Categories.
Add the words "Buildings for schools through secondary or day-care centers—capacity more than 250 students" below the words "Fire and police stations" in the Essential Facilities category, and delete those words from within the Special Occupancy Structure Category.
Add in item III Special Occupancy Structure to the words, "All structures with occupancy > 5000 persons", the words "excluding Occupancy Group E buildings".
Table No. 23-O, Structural Systems.
Delete this table and notes and substitute the following new Table No. 23-O and notes.
Table No. 23-O Structural Systems
Basic Structural System Lateral Load-Resisting System Description R w A. Bearing WallSystem 1. Light-framed walls with shear panels 1. a. Plywood walls for structures three stories or less 8 1. b. All other light-framed walls 6 2. Shear Walls 2. a. Concrete 6 2. b. Reinforced masonry 5 3. Light steel-framed bearing walls with tension-only bracing 4 4. Braced frames where bracing carries gravity load 4. a. Steel 6 4. b. Concrete 4 4. c. Heavy timber 4 B. Building Frame 1. Steel eccentric braced frame (EBF) 10 B. System 2. Light-framed walls with shear panels 2. a. Plywood walls for structures three-stories or less 9 2. b. All other light-framed walls 7 3. Shear Walls 3. a. Concrete 8 3. b. Reinforced masonry 6 4. Concentric braced frames 4. a. Steel 8 4. b. Concrete 8 4. c. Heavy Timber 8 C. Moment-Resisting Frame 1. Special moment-resisting frames (SMRF) 1. a. Steel 12 C. System 1. b. Concrete 12 2. Concrete intermediate moment-resisting frames (IMRF) 8 3. Ordinary moment-resisting frames (OMRF) 3. a. Steel 6 3. b. Concrete4 4 D. Dual System 1. Shear Walls 1. a. Concrete with SMRF 12 1. b. Concrete with steel OMRF 6 1. c. Concrete with concrete IMRF 9 1. d. Concrete with concrete OMRF 5 1. e. Reinforced masonry with SMRF 8 1. f. Reinforced masonry with steel OMRF 6 1. g. Reinforced masonry with concrete IMRF 7 2. Steel eccentric braced frame 2. a. With steel SMRF 12 2. b. With steel OMRF 6 3. Concentric braced frames 3. a. Steel with steel SMRF 10 3. b. Steel with steel OMRF 6 3. c. Concrete with concrete SMRF 9 3. d. Concrete with concrete IMRF 6
Notes:
1. Basic structural systems are defined in Section 2312(d)6.
2. See Section 2312(e)3 for combinations of structural systems.
3. See Sections 2312(d)8C and 2312(d)9B for undefined systems.
4. Prohibited with S3 or S4 soil profiles or where the height exceeds 160 feet.
Table No. 23-P, Horizontal Force Factor Cp.
Delete this table and notes and substitute the following new Table No. 23-P and notes:
Table No. 23-P Horizontal Force Factor Cp 1
Elements of Structures, Nonstructural Components and Equipment Value of C p I. Part of Portion of Structure I. 1. Walls, including the following: I. 1. a. Unbraced (cantilevered) parapets. 2.00 I. 1. b. Other exterior walls above street grade2. 0.75 I. 1. c. All interior bearing walls. 0.75 I. 1. d. All interior nonbearing walls and partitions around vertical exits, including offsets and exit passageways. 0.75 I. 1. e. Nonbearing partitions and masonry walls in areas of public assembly > 300 people. 0.75 I. 1. f. All interior nonbearing walls and partitions made of masonry in Occupancy I, II and III. 0.75 I. 1. g. Masonry or concrete fences at grade over 10 feet high. 0.50 I. 2. Penthouses (defined in article 2 of subchapter 2 of chapter 1 of title 27 of the building code) except where framed by an extension of the building frame. 0.75 I. 3. Connections for prefabricated structural floor and roof elements other than walls (see above) with force applied at center of gravity. 0.75 I. 4. Diaphragms3. II. Nonstructural Components II. 1. a. Exterior ornamentation and appendages including cornices, ornamental statuaries or similar pieces of ornamentation. 2.00 II. 1. b. Interior ornamentation and appendages in areas of public assembly including cornices, ornamental statuaries or similar pieces of ornamentation. 2.00 II. 2. Chimneys, stacks, trussed towers and tanks on legs. II. 2. a. Supported on or projecting as an unbraced cantilever above the roof more than one-half its total height. 2.00 II. 2. b. All others, including those supported below the roof with unbraced projection above the roof less than one-half its height, or braced or guyed to the structural frame at or above its center of mass. 0.75 II. 3. Exterior signs and billboards. 2.00 III. Equipment and Machinery 4 III. 1. Tanks and vessels (including contents), including support systems and anchorage. 0.75
Notes:
1. See Section 2312(g)2 for additional requirements for determining Cp for nonrigid equipment or for items supported at or below grade.
2. See Section 2312(h)2D(iii) and Section 2313(g)2.
3. See Section 2312(h)2I.
4. Equipment and machinery include such items as pumps for fire sprinklers, motors and switch gears for sprinkler pumps, transformers and other equipment related to life-safety including control panels, major conduit ducting and piping serving such equipment and machinery.
Figure No. 3, Normalized Response Spectra Shapes.
Delete the Figure No. 3 and insert the new Figure 3 and Table No. 23-R.
Table No. 23-R Spectral Acceleration in Fraction of G 5% Damping
T-SEC S 0 S 1 S 2 S 3 .01 0.150 0.150 0.150 0.150 .02 0.150 0.150 0.150 0.150 .05 0.375 0.283 0.262 0.244 .075 0.375 0.375 0.336 0.303 .090 0.375 0.375 0.375 0.334 .112 0.375 0.375 0.375 0.375 .267 0.375 0.375 0.375 0.375 .40 0.250 0.375 0.375 0.375 .48 0.208 0.313 0.375 0.375 .60 0.167 0.250 0.300 0.375 1.00 0.100 0.150 0.180 0.225 2.00 0.050 0.075 0.090 0.113 3.00 0.033 0.050 0.060 0.075
Note: This table presents acceleration (g) versus natural period (seconds) to facilitate the presentation of spectra in log-log form.
Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 1995/017.