4.1. GENERAL.—The design of masonry may be predicated upon analysis of stress or upon the empirical provisions indicated in this reference standard. The provisions of this section shall apply only where the design is predicated on analysis of stress. Except as specifically indicated, stresses shall be calculated on the basis of actual rather than nominal dimensions. For provisions relating to infrequent stress conditions the structural design provisions of the building code on combination of loads shall apply.

TABLE RS 10–1–2 Types of Mortar Permitted

Type of Masonry Type of Mortar Permitted a Masonry in contact with earth H, M or Sb Grouted and filled cell masonry H, M or S Masonry above grade or interior masonry: • Columns of solid units H, M, S, N or O • Columns of hollow units H, M or S • Walls of solid units H, M, S, N or O • Walls of hollow units H, M, S or N • Cavity walls and masonry bonded hollow walls H, M, S or N • Glass Block Masonry S or N • Non-loadbearing partitions and fireproofing H, M, S, N, O or Gypsum • Gypsum partition tile or block Gypsum • Linings of existing masonry, either above or below grade H, M or S

Notes—

a M, S, N, and O as defined by reference standard RS 10–46.

b Type N mortar may be used where masonry in contact with the earth will not be exposed to frost.

4.2. ALLOWABLE COMPRESSIVE STRESSES.—

4.2.1. General.—The allowable compressive stress in any type of masonry construction due to axial loads shall not exceed 0.25f 'm for walls or 0.2f 'm for columns. The allowable compressive stress in type H mortar construction due to flexural loads shall be 0.33 f ' m . The value of f ' m shall be based on the cross-sectional area (A g ) as defined in Sections 4.4.4 (a) and (b). Where Method No. 1 (Section 4.2.2(a)) is used, the value of f ' m shall be the specified minimum 28-day compressive strength of the masonry or the specified minimum compressive strength at any earlier age at which the masonry may be expected to receive its full load. Plans shall show the compressive strength of masonry (f ' m ) at a specified age for which the several parts of the structure were designed. Where Method No. 2 (Section 4.2.2(b)) is used, the tabulated values of f ' m shall be multiplied by the ratio of the strength of the mortar at a given age to the specified strength of the mortar at the age of 28 days, except that said ratio shall not be taken as greater than 1.0.

4.2.2. Determination of compressive strength of masonry.—The determination of the compressive strength of masonry (f ' m ) shall be made by one of the following methods:

(a) Method no. 1—Prism tests.—When the compressive strength of the masonry is to be established by preliminary tests, the tests shall be made in advance of the operations, using prisms built of similar materials under the same conditions and, insofar as possible, with the same bonding arrangements as for the structure. In building the prisms, the moisture content of the units at the time of laying, the consistency of the mortar, the thickness of mortar joints, and the workmanship shall be the same as will be used in the structure. Assembled specimens shall be at least 16 in. high and shall have a height-to-thickness ratio (h/t) of at least 2 but not more than 5. If the (h/t) ratio of the prisms tested is less than 5, the compressive strength values indicated by the tests shall be corrected by multiplying by the factor indicated in table RS 10–1–3.

TABLE RS 10–1–3 Correction Factors for h/t Ratio

Ratio of height to thickness (h/t) 2.0 2.5 3.0 3.5 4.0 5.0 Correction Factor a 0.73 0.80 0.86 0.91 0.95 1.00

a Interpolate to obtain intermediate values.

Prisms shall be tested after aging for 28 days in accordance with the applicable provisions of reference standard RS 10–17. Seven-day tests may be used, provided the relation between the 7- and 28-day strengths of the masonry is established by tests of the materials used. Not less than five specimens shall be tested.

(b) Method no. 2—Unit tests.—In lieu of prism tests, an assumed value of f 'm may be interpolated from the values in Table 10–1–4. Compressive strength of the masonry units shall be determined from tests conducted in accordance with applicable ASTM specifications.

TABLE RS 10–1–4 Assumed Compressive Strength of Masonry a b

Compressive Strength of units (psi) Assumed Compressive Strength of Masonry f ' m (psi) Type H Mortar Type M Mortar Type S Mortar Type N Mortar Type O Mortar Solid Clay or Shale Units • 14,000 or more 5,000 4,600 3,900 3,200 — • 10,000 5,000 3,400 2,900 2,400 — • 6,000 5,000 2,200 1,900 1,600 — • 2,000 1,000 1,000 900 800 — Solid Concrete or Sand-Lime Units • 6,000 2,000 2,000 1,700 1,400 — • 4,000 1,500 1,500 1,300 1,100 — • 2,500 1,100 1,100 1,000 900 — • 1,800 950 950 860 770 — • 1,200 800 950 860 770 — Hollow Units (Clay, Shale, or Concrete)* • 6,000 5,000 2,000 1,700 1,400 — • 4,000 1,500 1,500 1,300 1,100 — • 2,000 1,000 1,000 900 800 — • 1,000 750 750 700 650 — Stone Ashlar Masonry • Granite 4,300 4,300 3,850 3,400 2,700 • Limestone or marble 2,700 2,700 2,400 2,150 1,750 • Sandstone or caststone 2,150 2,150 1,900 1,700 1,350 • Rubble stone, coursed, rough rough or random 750 750 650 550 450

Notes—

a Where masonry cement mortar is used, if the amounts of Portland cement and lime are established and conform to the requirements for the mortar type indicated in the table, the values in this table apply. Masonry cement mortar in which the proportions are not identified shall not be used for masonry construction proportioned on the basis of the analysis of stress.

b For grouted masonry and filled cell masonry, f 'm shall be based on the values given for solid units and hollow units respectively. See Section 8.

c The ratio of the bedded area to gross area shall not be less than 0.25. For units having a lesser ratio of mortar bedded area than 0.25, the f 'm values shall be determined by Method No. 1 (prism tests).

4.3 ALLOWABLE FLEXURAL, TENSION, AND SHEAR STRESSES.—The allowable stresses in flexural tension and in shear shall not exceed the values set forth in table RS 10–1–5, except as permitted in other sections of this reference standard. The resistance in flexural tension and shear where the wall section is penetrated by flashing shall be investigated on the basis that the resistance is limited to the fractional resistance.

4.3.1 The allowable flexural tension stress for masonry constructed with Type H mortar shall be the same as with Type M or S mortar (Table RS 10–1–5) except that when clay or shale masonry units are used the allowable flexural tension shall be 0.30f 't but not greater than 112 psi and the allowable shear shall be 100 psi provided:

a). The brick is ASTM C 62–69 grade SW or MW.

b). The brick has no silicone treatment.

c). The initial rate of absorption of the brick does not exceed 35 grams/minute 730 square inches when tested in accordance with ASTM C 67–62.

d). The brick are extruded side cut units.

e). The average compressive strength of the brick units is 6,000 psi when tested in accordance with ASTM C 67–69.

f). f 't is determined by building 5 stack bond single wythe prisms one brick wide and seven brick tall. The prisms shall be cured for 28 days at about 75° F and 50% relative humidity. Specimens shall then be tested as a simple beam with third point loading as described in ASTM C 78–64.

g). Test reports indicating the determination of f 't shall be submitted by either the applicant or the Architect or Engineer designated for Controlled Inspection prior to commencement of construction of masonry.

4.3.2 The allowable flexural tension stress for masonry constructed with Type H mortar and clay or shale masonry units which do not meet the requirements of section 4.3.1 (c) through (d) shall be 0.30f 't provided f 't is determined by ASTM E 72–61, uniform transverse load strength method B after 28 days cure at 75° F and 50% R.H. The test panels shall be single wythe, 8 feet tall and 4 feet wide. In addition, units producing wall strength less than 360 psi when tested as outlined above must be tested by building additional single wythe panels constructed and tested for uniform transverse load strengths immediately after being subjected to the National Bureau of Standard Water permeability Tests for a period of five days following the normal 28 day cure.

4.3.3 Wetting of brick in construction of masonry using Type H mortar shall not be permitted.

4.3.4 Allowable flexural tension stresses for masonry constructed by Type H mortar may be increased 33 1/8% when considering wind load.

4.4 DESIGN OF MASONRY WALLS AND COLUMNS.—

4.4.1. Slenderness ratio.—

(a) The slenderness ratio (ratio of effective height, h ', or length of the wall panel to the effective thickness, t) shall not exceed 30 for walls of solid units, 20 for walls of hollow units, and 25 for walls of filled cell or grouted masonry.

(b) The slenderness ratio (ratio of the effective height, h ', to the least effective thickness, t) shall not exceed 25 for columns of solid units, 15 for columns of hollow units and 20 for columns of filled cell or grouted masonry.

(c) The slenderness ratio shall not exceed 40 for walls and columns of masonry constructed with type H mortar.

4.4.2 Effective height.—The effective height, h ', of columns and wall shall be determined by the architect or engineer who prepares the plans, who shall consider the conditions of end restraint provided in the particular case.

TABLE RS 10–1–5 Allowable Stresses in Flexural Tension and in Shear

Allowable Stresses (psi) on Cross-Sectional Area (Except as Noted) Normal to bed joints a Parallel to bed joints b Construction Type d Flexural Tension Shear Mortar Type c H M or S N H M or S N H M or S N Clay or Shale Masonry Units: • Solid 112 f 36 28 112 f 72 56 100 50 40 • Hollow e 112 f 15 10 112 f 30 20 100 30 20 Concrete Masonry Units: • Solid 25 f 25 18 50 f 50 36 30 30 20 • Hollow e 15 f 15 10 50 f 30 20 30 30 20 Sand-Lime Masonry Units: • Solid 30 f 30 20 60 f 60 40 40 40 35 • Hollow e 15 f 15 10 30 f 30 20 30 30 20 Stone Masonry Units: • Natural Stone 25 f 25 18 50 f 50 36 30 30 20 • Cast Stone 25 f 25 18 50 f 50 46 30 30 20

Notes—

a Direction of stress is normal to bed joints construction.

b Direction of stress is parallel to bed joints. If masonry is laid in stack bond, tensile stress values for tension parallel to bed joints shall not be used.

c Where masonry cement mortars are used, if the amount of Portland cement and lime is established and conforms to the requirements for Type M, S, or N mortar, the provisions of this table shall apply. Masonry cement mortar in which the proportions are not identified shall not be used for masonry construction proportioned on the basis of the analysis of stress.

d For computing flexural resistance, the moment of inertia of a cavity wall shall be based on the assumption that the two wythes act independently. The moment of inertia of a masonry bonded hollow wall may be based on the assumption that there is adequate shear resistance between the wythes to assure that they act together.

e Net area in contact with mortar.

f The allowable flexural tensile stress may be increased by 33 1/8% (or to 150 psi) when considering wind load.

4.4.3. Effective thickness.—

(a) For solid masonry, grouted masonry, filled cell masonry, hollow masonry, and masonry bonded hollow walls, the effective thickness, t, shall be taken as the actual thickness.

(b) For cavity walls loaded on both wythes, the effective thickness, t, shall be taken as 2/3 the sum of the actual thickness of both wythes.

(c) For cavity walls loaded on one wythe only, the effective thickness, t, shall be taken as the actual thickness of the loaded wythe or 2/3 the sum of the actual thickness of both wythes, whichever is the lesser value.

(d) For columns, the effective thickness shall be taken as the least actual thickness.

4.4.4. Allowable vertical loads.—

(a) AXIAL LOADS ON WALLS—Allowable axial loads on masonry walls P, shall be computed by the following formula:

P=c(0.25f 'm)Ag

Where:

c = stress reduction factor given in table RS 10–1-c, corresponding to the slenderness ratio

Ag = cross-sectional area of the wall.

For solid masonry, grouted masonry, stone masonry and filled cell masonry, Ag shall be computed on the basis of actual thickness without deduction for cells or cores.

For hollow masonry walls, Ag shall be taken as the net cross-sectional area of the units. Where the ratio of mortar bedded area to gross area is less than 0.25, Ag shall then be multiplied by a factor equal to mortar bedded area divided by 0.25 times the gross area.

Where both wythes of a cavity wall support vertical load, Ag shall be taken as cross-sectional area of wall computed as above minus the actual area of the cavity between wythes. Where only one wythe supports vertical load, Ag shall be taken as the cross-sectional area of the loaded wythe computed as above.

(b) AXIAL LOADS ON COLUMNS—Allowable axial loads on masonry columns shall be computed by the following formula:

P=c(0.20f 'm)Ag

Where:

c = stress reduction factor given in table RS 10–1-c corresponding to the slenderness ratio

Ag = cross-sectional area of the column

For solid masonry, grouted masonry, stone masonry, and filled cell masonry, Ag shall be computed on the basis of actual thickness without deduction for cells or cores.

For hollow masonry columns, Ag shall be taken as the net cross-sectional area of the units. Where the ratio of mortar bedded area to gross area is less than 0.25, Ag shall then be multiplied by a factor equal to mortar bedded area divided by 0.25 times the gross area.

(c) ECCENTRIC LOAD—

(1) Where the eccentricity of the loads on the member does not exceed 1/3 the thickness, the allowable vertical load on walls and columns shall be computed in accordance with section 4.4.4(a) and section 4.4.4(b), respectively, using the stress reduction factors given in table RS 10–1–6.

TABLE RS 10–1–6 Stress Reduction Factors (c) a

Slenderness Ratio Eccentricity as a Proportion of the Thickness of the Member 0 to 1/20 1/6 1/3 5 1.00 0.66 0.32 10 0.92 0.63 0.27 15 0.79 0.56 0.22 20 0.64 0.42 0.16 25 0.49 0.36 0.12 30 0.38 0.27 0.–8 35 0.27 40 0.21

Notes—

a Linear interpolation between values for stress factors is permissible.

(2) Where the eccentricity exceeds 1/3 the thickness, the maximum tensile stress in the masonry, assuming linear stress distribution (P/A ± M/S), shall not exceed the values given in table RS 10–1–5 or the member shall be reinforced in accordance with the requirements of reference standard RS 10–2.

(3) In computing the eccentricity of loads on walls and columns, consideration shall be given to the effects of lateral load, eccentricity of vertical load, and the deflection, thermal and other movements of members. For solid masonry, grouted masonry, filled cell masonry, hollow masonry, masonry bonded hollow walls and cavity walls loaded on both wythes, the eccentricity shall be considered with respect to the centroidal axis of the member. For composite members, the eccentricity shall be considered with respect to the centroidal axis of the transformed area of the member. For cavity walls loaded on one wythe, the eccentricity shall be considered with respect to the centroidal axis of the loaded wythe.

4.5 COMPOSITE WALLS OR FACED WALLS.—In composite walls, faced walls, or other structural members composed of different kinds or grades of units or mortars, the maximum stresses shall not exceed the allowable stresses for the weakest of the combinations of units and mortars of which the member is composed. In cavity walls, where only one wythe supports vertical load, the stresses shall not exceed the allowable stresses for the units and mortars comprising that wythe.

4.6 DISTRIBUTION OF CONCENTRATED LOADS.—The length of the wall to be considered as effective in resisting a concentrated load shall not exceed the center-to-center distance between loads, nor shall it exceed the width of bearing plus four times the wall thickness. Concentrated loads shall not be considered as distributed by metal ties, or distributed across continuous vertical joints.

4.7 BEARING STRESSES.—Allowable bearing stresses may be taken as 1.5 times the corresponding allowable compressive stress, provided that the area of the bearing plate does not exceed 1/3 of the area of the member supporting the bearing plate and the least distance between the edges of the loaded and unloaded areas is a minimum of 1/4 of the parallel side dimension of the loaded area. For bearing on the full area, the allowable bearing stress shall be taken as equal to the allowable compressive stress. For reasonably concentric bearing areas greater than 1/3, but less than the full area, the allowable bearing stress shall be interpolated between 1.0 and 1.5 times the allowable compressive stress.