  6. RS 13-1

NYC Administrative Code RS 13-1

NFiPA No. 90A–96, as modified, Standard for the Installation of Air Conditioning and Ventilation Systems.

Those provisions of ANSI/NFiPA No. 90A–96 as herein set forth with the modifications thereto shall constitute Reference Standard RS 13–1.

The appendices to ANSI/NFiPA No. 90A–96 are not part of this Reference Standard. These are for informational purposes only, and are not reproduced here.

Wherever reference is made to the "National Electrical Code" it shall be changed to read "Electrical Code of the City of New York."

The New York State Energy Conservation Construction Code also regulates the design and construction of heating, ventilating, and air conditioning systems in New York City.

STANDARD FOR THE INSTALLATION OF AIR CONDITIONING AND VENTILATION SYSTEMS

ANSI/NFiPA No. 90A—1996, AS MODIFIED

CONTENTS

Chapter 1—General 1–1 Introduction 1–2 Scope 1–3 Purpose 1–4 Maintenance 1–5 Definitions Chapter 2—HVAC Systems 2–1 General Requirements—Equipment 2–1.5 Equipment Location 2–2 System Components 2–2.1 Outside Air Intakes and Exhaust 2–2.2 Air Cleaners and Air Filters 2–2.3 Fans 2–2.3.1 Installation 2–2.3.2 Access 2–2.3.3 Exposed Inlets 2–2.4 Air Cooling and Heating Equipment 2–2.4.1 Installation 2–2.4.2 Appliances 2–2.4.3 Mechanical Cooling 2–2.4.4 Furnaces 2–2.4.5 Duct Heaters 2–3 Air Distribution 2–3.1 Air Ducts 2–3.2 Air Connectors 2–3.3 Supplementary Materials for Air Distribution Systems 2–3.4 Air Duct Access and Inspection 2–3.5 Air Duct Integrity 2–3.5.3 Air Duct at Heat Sources 2–3.6 Air Outlets 2–3.6.1 General 2–3.6.2 Construction of Air Outlets 2–3.6.3 Location of Air Outlets 2–3.7 Air Inlets (Return or Exhaust or Return and Exhaust) 2–3.7.1 General 2–3.7.2 Construction of Air Inlets 2–3.7.3 Location of Air Inlets 2–3.8 Fire Dampers 2–3.9 Smoke Dampers 2–3.10 Plenums 2–3.10.1 Ceiling Cavity Plenum 2–3.10.2 Duct Distribution Plenum 2–3.10.3 Apparatus Casing Plenum 2–3.10.4 Air-Handling Unit Room Plenum 2–3.10.5 Raised Floor Plenum 2–3.11 Corridor Air Systems 2–3.11.1 Egress Corridors 2–3.11.2 Exits 2–3.12 Smoke Control Chapter 3—Integration of a Ventilation and Air-Conditioning System(s) with Building Construction 3–1 Air-Handling Equipment Rooms 3–1.1 General 3–1.2 Air-Handling Equipment Rooms Used as Plenum Space 3–1.3 Air-Handling Equipment Rooms that have Air Ducts that Open Directly into a Shaft 3–1.4 Other Spaces Housing Air-Handling Units 3–2 Building Construction 3–2.1 Air Duct Clearance 3–2.2 Structural Members 3–3 Penetrations—Protection of Openings 3–3.1 Fire-Rated Walls and Partitions 3–3.2 Floors Required to Have a Fire Resistance Rating 3–3.3 Floor/Roof-Ceiling Assemblies Having a Fire Resistance Rating 3–3.4 Shafts 3–3.4.1 Enclosure of Ducts 3–3.5 Location of Smoke Dampers 3–4 Fire Dampers, Smoke Dampers and Ceiling Dampers 3–4.5 Damper Closure 3–4.6 Installation 3–4.6.4 Patching, Filling and Repairing 4–1 Wiring 4–2 Manual Control 4–3 Smoke Dampers Chapter 4—Controls 4–4 Smoke Detection for Automatic Control 4–4.1 Location 4–4.2 Function 4–4.3 Installation