10.1 CHASES AND RECESSES.—

10.1.1 Limitations.—Chases in masonry walls shall not be deeper than 1/8 the wall thickness. Vertical chases adjacent to bearings of beams or lintels, vertical chases wider than 12 in., and all horizontal chases shall be proportioned on the basis of the analysis of stress. No chase shall be allowed within the required area of a column or pilaster. The clear spacing between chases shall not be less than three times the width of the larger adjacent chase.

10.1.2 Exceptions for 8 in. Walls.—In buildings of residential occupancy not over 2 stories in height, vertical chases not more than 4 in. deep and not more than 4 square feet of wall area may be built in 8-inch walls, except that recesses below windows may extend from floor to sill and be the width of the opening above. Masonry directly above chases or recesses wider than 12 in. shall be supported on lintels.

10.2 CORBELLING.—The maximum horizontal projection of corbelling from the face of the wall shall not exceed 1/2 the wall thickness. The maximum projection of one unit shall not exceed 1/2 the height of the unit or 1/3 its bed depth. The top corbel course shall be a full course of headers at least 6 in. long. Corbelling of hollow walls or walls of hollow units shall be supported on at least one full course of solid masonry. Unless structural support and anchorage is provided to resist the overturning moment, the center of gravity of all projecting masonry or molded cornices shall lie within the middle third of the supporting wall.

10.3 ARCHES AND LINTELS.—The masonry above openings shall be supported by well buttressed arches or by lintels that bear on the wall at each end for at least 4 in.

10.4 PARAPET WALLS.—All cells in the hollow masonry units and all joints in solid, cavity, or masonry bonded hollow wall construction shall be filled solid with mortar. All corners of masonry parapet walls shall be reinforced with joint reinforcement or its equivalent at vertical intervals not greater than 12 in. Such reinforcement shall extend around the corner for at least 4 ft. in both directions and splices shall be lapped at least 6 in. Parapet walls shall be properly coped and flashed with noncombustible, weather-proof material of a width not less than the width of the parapet wall plus sufficient overage for overlaps. Nonreinforced masonry parapet walls shall be not less than 8 in. in thickness and their height shall not exceed three times their thickness. Reinforced parapet walls shall be designed in accordance with the provisions of reference standard RS 10–2.

10.5 GLASS BLOCK.—Masonry of glass blocks may be used in non-loadbearing exterior or interior walls and in openings that might otherwise be filled with windows, either isolated or in continuous bands, provided the glass block panels have a thickness of at least 3 1/2 in., at the mortar joint and the mortared surfaces of the blocks are satisfactorily treated for mortar bonding. Glass block shall be laid in type S or N mortar. Both vertical and horizontal mortar joints shall be at least 1/4 in. and not more than 3/8 in. thick and shall be completely filled.

Glass block panels for exterior walls shall not exceed 144 sq. ft. of unsupported wall surface nor 25 ft. in length or 20 ft. in height between supports. For interior walls, glass block panels shall not exceed 250 sq. ft. of unsupported area nor 25 ft. in one direction between supports.

Exterior glass block panels shall be held in place in the wall openings to resist both external and internal pressures due to wind. Panels shall be set in recesses at the jambs, and panels exceeding 10 ft. in horizontal dimension between supports shall be set in recesses at the head so as to provide a bearing surface at least 1 in. wide along the panel edges. However, for panels exceeding neither 100 sq. ft. in area nor 10 ft. in either horizontal or vertical dimension, and situated four stories or less and less than 50 ft. above grade level, anchorage may be provided by means of noncorrodible perforated metal strips or equivalent.

Glass block panels shall have reinforcement in the horizontal mortar joints, extending from end to end of mortar joints but not across expansion joints, with any unavoidable joints spliced by lapping the reinforcement not less than 6 in. The reinforcement shall be spaced at not more than 2 ft. vertically. In addition, reinforcement shall be placed in the joint immediately above and below all openings within a panel. The reinforcement shall conform to the requirements of section 3.3.1, or shall be equivalent in strength.

Every exterior glass block panel shall be provided with expansion joints at the sides and top. Expansion joints shall be entirely free of mortar, and shall be filled with resilient material.

10.6 BEARING DETAILS.—Concentrated loads shall be supported upon a solid construction of solid masonry, concrete, or masonry of hollow units with cells filled with mortar, grout, or concrete and of sufficient height to distribute safely the loads to the wall, plaster, or column, or other adequate provisions shall be made to distribute the loads.

10.6.1 Joists.—Solid construction for support under joists shall be at least 2 1/4 in. in height, and joists supported on such construction shall extend into the masonry at least 3 in.

10.6.2 Beams.—Solid construction for support under beams, girders, or other concentrated loads shall be at least 4 in. in height and the bearing of beams shall extend into the masonry at least 3 in.

10.7 USE OF EXISTING WALLS.—An existing masonry wall may be used in the alteration or extension of a building provided that under the new conditions it meets the requirements of this standard and is structurally sound or is made so.

10.7.1 Walls of insufficient thickness.—Existing walls of masonry units that are structurally sound, but that are of insufficient thickness when increased in height, may be strengthened by an addition of similar masonry units laid in type M or S mortar. The foundations and lateral support shall be equivalent to those required for newly constructed walls under similar conditions. All such linings shall be thoroughly bonded into existing masonry by toothings to assure combined action of wall lining. Toothings shall be distributed uniformly throughout the wall, and shall aggregate in vertical cross-sectional area at least 15 per cent of the total surface area of the lining. Stresses in the masonry under the new conditions shall not exceed the allowable stresses of section 4.2 and 4.3.

10.8 PRECAUTIONS DURING ERECTION.—Temporary bracing shall be used whenever necessary to take care of any loads to which the walls may be subjected during erection. Such bracing shall remain in place as long as may be required for safety.

10.9 MIXING MORTAR AND GROUT.—All cementitious materials, aggregates, and water shall be mixed for a minimum of 5 minutes in a mechanical batch mixer. If the mortar begins to stiffen, the mortar may be retempered by adding water and remixing. The consistency of grout shall be such that, at time of placement, it has a slump of 10 1/2 to 11 in. as determined by reference standard RS 10–49. All mortar and grout shall be used within 2 1/2 hr. of initial mixing and no mortar or grout shall be used after it has begun to set.

10.10 FILLING JOINTS.—In unit masonry construction, all vertical and horizontal joints designed to receive mortar or grout shall be completely filled. The thickness of mortar joints in loadbearing masonry shall not exceed 1/2 in. Solid masonry units shall be laid with full head and bed joints. Hollow masonry units shall be laid with full mortar coverage on vertical and horizontal face shells.

10.11 MINIMUM JOINT THICKNESS FOR REINFORCEMENT.—The thickness of grout or mortar between masonry units and reinforcement shall be at least 1/4 in. except that 1/4 in. bars may be laid in 1/2 in. horizontal mortar joints, and No. 6 steel wire gage or smaller wires may be laid in 3/8 in. horizontal joints.

10.12 PROTECTION FOR REINFORCEMENT.—Reinforcement consisting of bars or wire 1/4 in. or less in diameter embedded in the horizontal mortar joints shall have at least 5/8 in. horizontal cover.

10.13 WETTING OF MASONRY UNITS.—

10.13.1 Clay or shale bricks.—All brick having an absorption rate in excess of 0.025 oz. per sq. in. per minute shall be wetted before laying, except no wetting shall be permitted for brick used with type H mortar. The method of wetting shall be such as to insure that each unit is nearly saturated, surface dry when laid. During freezing weather, units that require wetting shall be sprinkled with warm water immediately before laying and shall be protected against formation of films of ice. No units with ice on the surface shall be laid.

10.13.2 Structural clay tile.—Structural clay tile having a 1-hr. boiling water absorption of 12 per cent or more shall be wetted before laying.

10.13.3 Concrete masonry units.—Concrete masonry units shall not be wetted before laying.

10.14 PROTECTION AGAINST FREEZING.—Adequate equipment shall be used for heating the masonry materials and protecting the masonry during freezing or near-freezing weather. No frozen material or materials containing ice shall be used.

Sand shall be heated in such a manner as to remove frost or ice. Water or sand shall not be heated to a temperature above 160 degrees F. When necessary to remove frost, the masonry units shall be heated.

When the outside temperature is below 40°F, an air temperature of at least 40°F shall be maintained on both sides of the masonry for a period of at least 48 hrs. if type M or S mortar is used, and 72 hr. if type N or O mortar is used. When type H mortar is used and the outside temperature is below 40° F, an air temperature of at least 50° F shall be maintained on both sides of the masonry for a period of 72 hours. This time may be reduced to 24 hours if high early strength cement is used. These periods may be reduced to 24 and 48 hr., respectively, if high-early-strength cement is used. All methods and materials for the protection of the fresh masonry work against freezing shall be subject to the approval of the commissioner. In general, methods and materials commonly accepted as suitable for the protection of reinforced concrete construction in freezing weather shall be used. Salt or other chemicals for lowering the freezing temperature of the mortar shall not be used.

10.15 STORAGE AT THE SITE.—All materials for masonry construction shall be stored in such a manner that they are kept free of excessive dirt and wetness.

10.16 HORIZONTAL COMPRESSION JOINTS.—All concrete framed high-rise buildings to be constructed over 150'–0" in height (as measured from adjoining grade to the main roof level), whose exterior walls are of cavity wall construction with steel lintels, shall have horizontal compression joints in the exterior walls to prevent masonry distress induced by vertical shortening of the structural frame.

(a) Horizontal compression joints shall be 1/4 inch in thickness (minimum), with 1/4 inch neoprene polyethylene, or urethane gasket or equivalent joint filler filling the entire joint, except for a recess from the toe of the lintel angle to the exterior of the facing brick, to provide space for caulking. These joints shall be spaced at 40 foot intervals (maximum), and the details shown on the plans.

(b) The applicant of record shall submit a statement (or engineering analysis) that the minimum code requirements as stated in (a) are sufficient to provide for the effects of vertical shortening of the structural frame or specify additional horizontal compression joints of at least 1/4 inch thickness.