NYC Administrative Code RS 10-5C STEEL STRUCTURES RESISTING EARTHQUAKE FORCES
UBC SECTION 2723–1990—Steel Structures Resisting Forces Induced by Earthquake Motions in Seismic Zones Nos. 1 and 2 with Accumulative Supplement.
MODIFICATIONS—The provisions of UBC Section 2723 shall be subject to the following modifications. The subdivisions, paragraphs, subparagraphs and items are from that standard.
Subdivision (a) General, Paragraph 1.
Delete this paragraph and substitute the following:
"1. Design and construction of steel framing in lateral force resisting systems shall conform to the requirements of this reference standard. The use of reference standard RS 10–5B is prohibited for the design of seismic resisting elements."
Subdivision (b) Definitions.
Delete this subdivision and substitute the following:
"(b) Definitions. ALLOWABLE STRESSES are prescribed in reference standard RS 10–5A.
CHEVRON BRACING is that form of bracing where a pair of braces located either above or below a beam terminates at a single point within the clear beam span.
CONNECTION is the group of elements that connect the member to the joint.
DIAGONAL BRACING is that form of bracing that diagonally connects joints at different levels.
ECCENTRIC BRACED FRAME (EBF) is that form of braced frame where at least one end of each brace intersects a beam at a point away from the column girder joint.
GIRDER is the horizontal member in a seismic frame. The words beam and girder may be used interchangeably.
JOINT is the entire assemblage at the intersections of the members.
K BRACING is that form of bracing where a pair of braces located on one side of a column terminates at a single point within the clear column height.
LINK BEAM is that part of a beam in an eccentric braced frame which is designed to yield in shear and/or bending so that buckling of the bracing members is prevented.
STRENGTH is the strength as prescribed in reference standard RS 10–5A.
V BRACING is that form of chevron bracing that intersects a beam above and inverted V bracing is that form of chevron bracing that intersects a beam from below.
X BRACING is that form of bracing where a pair of diagonal braces cross near midlength of the bracing members."
Subdivision (c) Materials.
Delete this subdivision and exception and substitute the following:
"(c) 1. Materials. Materials shall be as prescribed in reference standard RS 10–5A. Structural steel designed to be part of the lateral force resisting system of multistory buildings shall not have a specified yield strength greater than 50,000 psi.
2. Member Strength. When these provisions require that the strength of the member be developed, the following shall be used:
Members: Strength Flexture Ms=ZFy Shear Vs=.55Fydt Axial compression Psc=1.7FaA Axial tension Pst=FyA Connectors: Full penetration welds FyA Partial penetration and fillet welds 1.7*Allowable Bolts 1.7*Allowable
Members need not be compact unless otherwise required by this chapter."
Subdivision (d) Ordinary Moment Frame Requirements.
Delete the words "Section 2723(e)1" and insert the words "paragraph 1 of Special Moment-resisting Frame (SMRF) Requirements".
Subdivision (e) Special Moment-resisting Frame Requirements (SMRF).
Paragraph 1, Subparagraph A. Required Strength.
Delete the words "Formula 22–1" in item (ii) and insert the words "the panel zone strength, defined as:
V=0.55Fydct(1 + 3bctcf 2/dbdct)
where:
t = the total thickness of the joint panel zone including doubler plates
db = the depth of the beam
dc = the column depth
bc = the width of the column flange
tcf = the thickness of the column flange".
Paragraph 3, Subparagraph A. Restrained joint.
Delete item (i) and substitute the following:
S/Zc(Fyc–fa)/SZbFyb>1.0
where (fa ³0)."
Paragraph 3, Subparagraph B. Unrestrained joint.
Delete the words "Section 2703, Formula (3–2)" in the first sentence and insert the words: "Section 1.6.2 of reference standard RS 10–5A".
Delete the words "Section 2723(e)3A and P-delta" in the sentence following item (ii) and insert the words "Section 2723(f)3A, as well as P-delta effects".
Add a new Paragraph 5 entitled Drift Calculations to read as follows:
"5. Drift Calculations. Drift calculations shall include bending and shear contributions from the clear girder and column spans, column axial deformation, and the rotation and distortion of the panel zone.
Exceptions:
1. Drift calculations may be based on column and girder centerlines where either of the following conditions is met:
a. It can be demonstrated that the drift so computed for frames of similar configuration is typically within 15 percent of that determined above.
b. The column panel zone strength can develop 0.8 Σ/Ms of the girders framing to the column flanges at the joint.
2. Column axial deformations may be neglected if they contribute less than 10 percent to the total drift."
Subdivision (f) Requirements for Braced Frames.
Paragraph 2, Subparagraph A. Stress reduction.
Delete the words "2702(b)3 and Section 2303(d)" of the definition of "Fa" and substitute the words "1.5.1.3 and Section 1.5.6 of reference standard RS 10–5A".
Paragraph 2, Subparagraph C. Compression elements in braces.
Delete the number "2706" and insert the words "1.9 of reference standard RS 10–5A".
Paragraph 3, Subparagraph B. Net area.
Delete the words "2722(g)3A" in F* and 2722(g)2A in α and insert the words "2723(f)3A" and "2723(f)2A" for F* and α, respectively.
Subdivision (h) Nondestructive Testing.
Delete the words "Section 2722(i)" and insert the words "reference standard RS 10–5A".
Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 1995/017.